23'-0"
<br /> 10'-6" � 12'-6" �
<br /> �
<br /> 5'-7" 4'-11„ 5, 0» �,_6°
<br /> 3'-0" � 9'-6" DS
<br /> C - - - - - - - - - - - �—� DS
<br /> �
<br /> � / ��- - - - - - - - - - - - - � �
<br /> F ' BUILT-IN
<br /> / SHELV 5 36" H COUNTER FRAME FOR I I
<br /> � W/ CAB. BELOW 5� TUB ' ' I �S�OPE SL_ OPE�_
<br /> / `�' o � 7-IN-12 7-IN-12 I �
<br /> 15 � � � � i � I
<br /> �
<br /> o , OPTIONAL SHELVES OR � � �,� I � I I
<br /> � CABINET ABOVE COUNTER AT cn I
<br /> � , THIS LOCATION. BUILDER TO `" ��� _ � I � �
<br /> , SELECT CEPTH OF SHELVES �� CO I � ROOF OVERHANGS I I
<br /> OR CABINET � LINE OF EXTERIOR
<br /> ALL ROOF OVERHANGS ARE �
<br /> O �� - � �WALLS BELOW (TYP) 16", UNLESS NOTED i � CARL J. COLSON — ARCHITECT PLLC
<br /> HIGH � � � I BIRD BLOCK VENTING AT OTHERWISE � 23623 20th AVENUE W BOTHELL,
<br /> WINDOWs 13'-6" 9'-6" �
<br /> � PORCH EAVES (lYP)
<br /> — � I ROOF VENTING I � WASHINGTON 98021 (425) 806-3'703
<br /> 1Vlaster BeC�r001�1 11 � A C�ESS 1 aSte� I I ANDFIDOWNSPOUTSL(TYP CAL) CALCULATIONSNFIOR MIN. ROOF I �
<br /> o � �i 13-0 x 12-2 cfl . '
<br /> i i � / � I I CIOSet � � i � COORD. DOWNSPOUT VENTING REQUIREMENTS �
<br /> � � � `� I I � � �v I I LOCATION W/ CIVIL DRAWINGS I I PROJECT:
<br /> , 9 -2 3'-11" 5�� 2� 4» � 3'-1" ��� � C° � � ATTIC ACCESS I �
<br /> - � _ _ � � SEE UPPER LEVEL FLOOR PLAN I I � �
<br /> FLUE IN � 8 � FURNACE FLUE FOR LOCATION OF Ai�IC ACCESS
<br /> � EXTERIOR WALL CO , SHELVES FLASH PER INDUSTRY HATCHES IN LAUNDRY ROOM I ��t � .e� ��S
<br /> cv RAISED FLOOR I I
<br /> i SHELVES � THIS AR � I �
<br /> � STANDARDS. INSTALL FLUE TO I I
<br /> > � � ' i � � HEIGHT AS REQ'D. BY CODE FA�L PROTECTION � ' +
<br /> C '' La 7 1`y �� , CONTRACTOR SHALL INSTALL i
<br /> R�� - CK �- � ROOF SAFETY ANCHORS PER �
<br /> O � N t�r � �� � � WASH � N � CODE IF REQUIRED (FASTENED I I �1� ���a,��
<br /> i � � . ��_��� F AM. �0 _ � DRYER -i HO � _SLOPE SKYLITE TO ROOF TRUSS/FRAMING) FOR � � �
<br /> �„ � �-_-_ F� - � _�_r 7 IN 12 � PROTECTION OF WORKERS ON �
<br /> � SKYLITE / � � �
<br /> � � � I N I— ROOF I i
<br /> N // 9 -� ! � � a � _ 4 _, � � � I I ���1������
<br /> I / 10 -6 3 -11 �
<br /> I � ROOF FRAMING � I
<br /> � r � I PRE-ENGINEERED WOOD I I
<br /> � - j � 4'_5„ pN 5, �„ ;� 4'-5° , a p �V�
<br /> /FRAME WALL 6 -4,_4J,GH ��_2� 4�_3,� g� ��, j � I ROOF TRUSSES @ 24�� O.C. I 99�9 ZI1U f�VellUe W
<br /> w j WITH OVERFRAMING AT �
<br /> � � VENT TUB THRU I � �z INDICATED AREAS. ROOF � I EVerett �A 9g2O�-
<br /> r N THIS WALL � � � 1 � -6 - = � � � I TRUSS MANUFACTURER WILL I '
<br /> � PAIR � `L�'� N ��6 ' / � � � I �� PROVIDE ROOF TRUSS � I
<br /> , o O 2668 � , STAIR HANDRAILS N N � I N FRAMING PLAN(-iYPICAL� I
<br /> , SEE SHEET A-4.1 �
<br /> N PAIR � � �z SEE ROOFING NOTES FOR I � CLIENT:
<br /> 8'-92" 3'-22" 5'-02" 7'-32" 2668 � I o j z FLASHING AT ALL ROOF � �
<br /> � HIGH � � �'r > VALLEYS (TYP) ( � C1� �L 1 1 1 C�erS N W
<br /> � wwoows �eC��UUm #Z BeC�rUOm #3 � 788 S.F. ATtIC AREA �
<br /> � LINE OF WALL BELOW o � � 410 14g�1 S�. NL�'
<br /> i I I AT GABLE ENDWALL � � I 1�rlingtOn, �T1� 9g2�3
<br /> � 11'-6"x 10'-0" ^i 11'-6°X 10'-6" O � _ SLOPE SLOPE �
<br /> �' � � 7-IN-12 7-IN-12 � �
<br /> HIGH I
<br /> / PRECENGINEER DArW00D ROOF)TRUSSES wiN�ows � I = �
<br /> � 24" O.C. SEE STRUCTURAL ROOF o _ ' � - - - - - - - - - - - - - - - � - - � I
<br /> � I
<br /> n � ��l � ��� � �
<br /> _ r- I
<br /> � �' FRAMING DRAWING � °'
<br /> 7� i� � in DS � _ - - - - - - - - - - - —
<br /> , ROOF OVER LEVEL 2 PORCH � I I I I
<br /> ' BELOW. SEE EXTERIOR BUILDING I I
<br /> � �� `v' � � � �
<br /> I �------ F --� I o E L E V A T I O N � _ �
<br /> - - - - - - - - - � - - - - - - - - - �
<br /> J u N � SLOPE �
<br /> � � � � 7-IN-12
<br /> 2� � � _ _ _ _F _ _ _ _ _ _ _ � SEE LEVEL 3 PLAN AND � � � � � ���
<br /> � � 7-IN-12 RoOF 7-IN-12 ROOF _ � BUILDI�JG ELEVATIONS FOR
<br /> SLOPE SLOPE EYEBROW ROOF OVER LIVING
<br /> ROOM WINDOWS AT LEVEL 2 PORCH ROOF BELOW AT LEVEL 2
<br /> 1'-4" 6'-5" 6'-7" 5'-0" 5'-0" BELOW
<br /> BUILDER TO COORD. LOCATIONS OF
<br /> ALL DOWNSPOUTS ON LOWER PORCH
<br /> 13'-0" 10'-0" ROOFS (TYP)
<br /> 23'-0"
<br /> � ) � x ,.
<br /> �P 1�A1� �['�IP ]� 1� m 1����E �L 3 �P 1�A1� �P 1�A1� ��� � � � � � 0 � � IL�l�T �=,r�r�:L }, �� �.:.
<br /> � ���. ��
<br /> � ;�i �:
<br /> SCALE 1 /4" = 1 '-0" SCALE 1 /4" = 1 '-0" �
<br /> REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION PLANS AND ALL FRAMWG PLANS (TYP) REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION PLANS AND ALL FRAMING PLANS (TYP) �"� t� �- ,f �s'� ' '
<br /> i �i�. � Vv,� :`j' ,� _, i
<br /> ;i .
<br /> � - - ::�
<br /> ROOF GENERAL NOTES R�OF GUTTERS ATTIC VENTING CALCULATIONS PERMIT SET NOTIFICATION
<br /> NOTES TO LEVEL 3 FLOOR PLAN THE CONTRACTOR SHALL REVIEW ALL ROOFING AND ROOFING INSTALL ALUMINUM GUTTERS AND DOWNSPOUTS AT LOCATIONS THE FOLLOWING CALCULATIONS PROVIDE THE "MINIMUM" VENTING AS
<br /> � NOTE: THE TERM "BUILDER" REFERS TO THE DEVELOPER 1� STAINED HARDWOOD PLYWOOD VENEER (TO MATCH FLASHING DETAILS WITH ROOFING MANUFACTURER. CONTRACTOR SHOWN ON ROOF PLAN AND BUILDING ELEVATIONS. PROVIDE REQUIRED BY THE 2006 INTERNATIONAL RESIDENTIAL CODE. THIS CODE This set of drawings is being issued as a Permit Set and
<br /> WHOSE RESPONSIBILITY INCLUDES THAT OF GENERAL STAIR RAILINGS) OR PTD. MDO AT WINDOW SEAT. WINDOW SHALL BE RESPONSIBLE FOR ALL ROOF ASSEMBLY AND BASKET STRAINER LEAFGUARDS IN GUTTERS AT TOP OF ALL ALLOWS AREA OF VENTS REQUIRED TO BE 1/300TH OF ROOF AREA IF is subject to change and adding of additional drawings
<br /> CONTRACTOR. SEAT SUPPORT SHALL BE 3/4" PLYWOOD OVER 2x4 STUD ROOFING DETAILS IN ORDER TO ACHIEVE A WEATHERPROOF DOWNSPOUTS. ALL DOWNSPOUTS SHALL DRAIN INTO BELOW 50� OF VENTS ARE AT EAVE AND 50� OF VENTS ARE AT RIDGE AND or information as required by review by City of Everett
<br /> THESE NOTES ARE FOR THE UPPER FLOOR PLAN AT ALL FRAMING AND JOISTS O 16" O.C.. PLATFORM OF WINDOW ROOFING ASSEMBLY. GRADE DRAINAGE SYSTEM . CONTRACTOR TO COORDINATE THIS IF A VAPOR BARRIER IS INSTALLED ON THE WARM SIDE OF ATTIC Building Department.
<br /> UNITS. ALL NOTES MAY NOT APPLY TO EACH UNIT. SEAT SHALL BE 20" ABOVE FINISH FLOOR. ITEM PRIOR TO FOUNDATION WORK. CONTRACTOR SHALL iNsu�a,-rioN. DO NOT USE THIS DRAWING FOR
<br /> 1� BUILT-IN SHELVES ABOVE SOAKING TUB. PAINTED 3/4" ROOFING MATERIALS CO�RDINATE PAINT COLOR FOR GUTTERS & DOWNSPOUTS CONSTRUCTION UNLESS THIS DRAWING HAS
<br /> TOILET CLEARANCES SHALL BE 15" FROM CENTER OF FIXTURE MDO W. WOOD TRIM AT SHELF EDGE. REFER TO BUILDING SECTIONS FOR ADDITIONAL ROOFING WITH OWNER. PROVIDE AND INSTALL SCREENED GUTTER ATTIC VENTING SHALL BE ACCOMPLISHED WITH BIRDSLOCK A CITY OF EVERETT BUILDING DEPARTMENT
<br /> GUARDS AT ALL GUTTERS. EAVE VENTS AND SHINGLE-OVER RIDGE VENTS. BIRD BLOCK VENTS
<br /> TO ADJACENT WALL OR COUNTERTOP. MIN. 30" CLEAR �� LOCATION OF FIREPLACE EXHAUST / INTAKE FLUE. MATERIAL NOTES AND TYPES. ARE BASED ON (3) 2-1/2" DIAMETER HOLES PER VENT BLOCK (5.2 ��APPROVED�� STAMP UPON COMPLETION OF
<br /> BETWEEN SIDE OR END WALL AND COUNTERTOP WITH TOILET COORD. W/ LOCATION OF FIREPLAC� BELOW AND ROOF
<br /> FIXTURE AT MIDPOINT. ATTIC ACCESS HATCHES SQ. INCHES PER uN. �r.). THE PERMIT REVIEW PROCESS.
<br /> FRAMING ABOVE. ROO F FRAM I N G PROVIDE INSULATED ATTIC ACCESS HATCH AT LOCATIONS
<br /> 1� BUILT-IN SHELVES: PAINTED 3/4" MDO W. WOOD TRIM Do not use for bidding or estimating purposes unless
<br /> � LINE OF EXTERIOR WALL BELOW. REFER TO MAIN LEVEL REFER TO STRUCTURAL FRAMING DRAWINGS FOR ROOF SHOWN ON UPPER LEVE� FLOOR P�N. PLAN TYPE B ATTIC VENTING CALCULATIONS authorized by Owner Develo e p �
<br /> AT SHELF EDGE. FIRST SHELF TO BE AT 8" ABOVE FLOOR. � p r. Develo er Builder
<br /> FLOOR PLAN FOR LOCATION AND INFORMATION. FRAMING INFORMATION. ATTIC ACCESS HATCHES IN 1 HR. CEILING SHALL HAVE A 1 THE FOLLOWINC CALCULATIONS ARE FOR THE MINIMUM ALLOWABLE shall be res onsible for construction crews are su lied
<br /> TOP OF SHELF ENCLOSURE TO BE AT 7'-0" ABOVE FLOOR. � P PP
<br /> , � LOCATION OF FLUE FROM FURNACE BELOW (IF FORCED HR. FIRE RATING (IF 1 HR. CEILINGS ARE SPECIFIED FOR THIS VENTS. SEE ROOF PLAN FOR LOCATION OF VENTS. CONTRACTOR SHALL with all approved and most current construction
<br /> AIR HEATING SYSTEM IS USED . BUILDER TO COORDINATE THIS COORD. SHELF HEAD W/ WINDOW TRIM.
<br /> � 1� STOP CLOSET ROD/SHELF � AREA OF WINDOW IN ROOFTOP PENETRATIONS PROJECT) INSTALL VENTING TO MEET THE FOLLOWING MINIMUM REQUIREMENTS. documents.
<br /> ITEM WITH FRAMER PRIOR TO FRAMING. ATTIC ACCESS HATCHES SHALL BE 22 x 30 (MIN. SIZE) ALL EAVE VENTING SHALL BE DISTRIBUTED EVENLY TO ASSURE
<br /> � WASHER & DRYER IN LAUNDRY ROOM. WASHER SNALL MASTER BEDROOM CLOSE�. INSTALL WINDOW SEAT BELOW NO PLUMBING VENT STACKS OR EXHAUST VENTS WILL BE AND SHALL HAVE 30" MINIMUM UNOBSTRUCTED HEADROOM IN PROPER AIR FLOW THROUGH ALL PORTIONS OF THE ATTIC AREA. BIRD
<br /> WINDOW. ALLOWED ON FRONT PORTION OF BUILDING ROOF FACING THE 1 4-16-08 PLAN B & C ISSUED FOR PERMIT
<br /> BE INSTALLED W/ FLOODSAVER DRAINLESS BASE PROTECTION AT�IC ABOVE THE OPENING. BLOCK VENTS SHALL BE EVENLY DISTRIBUTED TO OBTAIN PROPER AIR
<br /> PAN (WWW.FLOODSAVER.COM) AND AN ELECTRONIC WASHER 2� LINE OF ROOF ABOVE. REFER TO ROOF PLAN FOR ALL STREET. ALL ROOFTOP PENETRATIONS, PIPES, VENT STACKS COORDINATE OPENING WITH ROOF FRAMING. FLOW IN ATTIC SPACE :
<br /> ROOF INFORMATION. SHALL BE FLASHED ACCORDING TO ACCEPTABLE INDUSTRY . )
<br /> FLOOD STOP SYSTEM (SAFEHOMEPRODUCTS.COM). DO NOT 2� SURFACE OF ROOF BELOW OVER PORCH OR EYEBROW STANDARDS. RESPONSIBILITY FOR ALL ROOFTOP FLASHING �
<br /> USE FLOODSAVER PAN WITH DRAIN OR RIDGES. COORDINATE ROOF OVER WINDOW BELOW OR GARAGE ENTRY. SEE DETAILS SHALL BE WITH GENERAL CONTRACTOR / ROOFING SKYLIGHTS (IF SHOWN ON PLANS) PLAN TYPE B ATTIC VENT CALC S
<br /> PLUMBING AND VENTING REQUIREMENTS WITH MANUFACTURER. INSTALL SKLIGHTS ON PRESSURE TREATED 2x4 WOOD CURBS
<br /> BUILDING ELEVATION DRAWINGS. SUBCONTRACTOR. 1) ROOF AREA = 788 S.F.
<br /> DO NOT VENT LAUNDRY VENT OR DRYER VENT THRU FRONT AND INSTALL WITH METAL FLASHING PER SKYLIGHT
<br /> 2� 36" HIGH COUNTER W/ PLASTIC LAMINATE TOP (W/
<br /> WALL OF RESIDENCE. MANUFACTURERS REQUIREMENTS. SKYLIGHT GLAZING SHALL BE 2) VENT AREA REQUIRED
<br /> � 36" HIGH STAIR RAILING OR HALF-WALL W/ WOOD CAP. �UNDRY SINK, IF SHOWN) IN LAUNDRY ROOM. ROOF ATTIC VENTING LAMINATED SAFETY GLASS. 788 DIVIDED BY 300 = 2.6 S.F.
<br /> SEE STAIR NOTES FOR GUARDRAIL INFORMATION.. 2� LINE OF PORCH COLUMNS BELOW. SEE MAIN LEVEL (SEE ATTIC VENTING CALCULATIONS FOR MIN. NUMBER OF 3) DISTRIBUTION OF VENTS NR. DATE REv151oN
<br /> 5. OPEN TO STAIRS BELOW. FLOOR PLAN FOR INFORMATION VENTS SKYLIGHT WELLS (IF SHOWN ON PLANS 50% � ROOF = 1.3 S.F.
<br /> � 24.� LINE OF STEPS AT FLGOR BELOW. � � *C*O*P*Y�`R*I*G*H*T*
<br /> � ONE-PIECE ACRYLIC TUB/SHOWER ENCLOSURE. ALL EAVES SHALL HAVE BIRD BLOCK EAVE VENTS BETWEEN PROVIDE FLARED SKYLIGHT OPENING AT CEILING LEVEL WHERE 50% � EAVES = 1.3 S.F.
<br /> � 2� FRAME FLOOR OF LINEN CLOSET TO BE SLOPING TO EXPOSED RAFTER TAILS. ALL ROOF RIDGES SHALL HAVE SKYLIGHTS ARE INDICATED ON FLOOR AND ROOF PLANS. 4) NUMBER OF VENTS These documents the ideas and desi s inco orated herein as an
<br /> � ONE PIECE WIRE CLOSET ROD AND SHELF - TYPICAL AT ALI OW MAX. REQUIRED HEADROOM AT STAIRS BELOW. ' � �
<br /> ALL CLOSETS. "SHINGLE-OVER" ROOF RIDGE VENTS. ATTIC VENTILATION: NET SKYLIGHT WELL WALLS SHALL BE PAINTED 1�2" GWB OVER 2 EAVE VENTS (BIRD BLOCK): 1.3 S.F = 187 SQ. IN. instrument of service and shall remain the property of Carl l.Colson-
<br /> 26,) CORNER OF STAIRWAY OPENING (WITN LEDGE) TO BE AT FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 150's x 6 STUD FRAMING � 16" O.C. WITH R-21 BATT DIVIDED BY 5.2 SQ. IN. L,F. = 36 LIN. F-f. OF BIRD
<br /> � ADJUSTABLE WIRE SHELVES AT LINEN AND STORAGE 45° ANGLE AS SHOWN. FRAME FLAT LEDGE TO BE ABOVE � � � � Architect YLLC and are solely for use on the residential project(City
<br /> CLOSETS. BUILDER TO SELECT NUMBER AND HEIGHTS OF OF THE AREA OF THE SPACE VENTILATED. A VAPOR BARRIER INSULATION. BOTTOM LENGTH OF SKYLIGHT WELL SHALL BE BLOCK VENTS Lights)on 2nd Ave.W,Everett,WA. 'These files may not be used on
<br /> SHELVES. ADJACENT HANDRAILS. (P.V.A. PAINT) WILL BE INSTALLED ON THE WARM SIDE OF 4'-0" MINIMUM OR AS DIRECTED BY BUILDER. ROOF RIDGE VENTS: 1.3 S.F. = 187 SQ. IN. DIVIDED BY
<br /> 27). LINE OF EXTERIOR FACE OF WALL BELOW. any other projects nor may they be transmitted electronically without
<br /> � SKYLIGHT ABOVE. REFER TO ROOF PLAN AND WINDOW ATTIC INSULATION. A MINIMUM OF 1" AIR SPACE SHALL BE 10 SQ. IN.�L.F. OF VENT = 18.7 LIN. FT. OF RIDGE VENT express permission of architect.They are not to be used by the client or
<br /> SCHEDULE FOR INFORMATION. PROVIDED BETWEEN THE INSULATION AND ROOF SHEATHING AT any other party or entity on this or other projects,in whole orpart,or as
<br /> 1� ONE PIECE SINK-COUNTERTOP (OR TILE COUNTERTOP) EAVE VENT LOCATIONS.
<br /> an extension tv this project except by agreement in writing with
<br /> W� MIRROR ABOVE AND WOOD CABINET BELOW AT ALL R00 F VALLEY �LAS H I N G appropriate financial compensation to Car11.Colson-Architect PLLC
<br /> BATHROOMS (TYP). SELECTION BY BUILDER. Copyright 2008 Carl J.Colson-Architect PLLC, O
<br /> 1� INSULATED ATTIC ACCESS HATCH. SEE NOTES ON ROOF INSTALL CONTINUOUS 36" WIDE (MIN.) "GRACE I(:E & WATER ,3 '� �' ,���:.� �rys �-��.., _�,��,,� Allrigbtsreserved �
<br /> PLAN SHEET. � � � � ,
<br /> 1� METAL DRYER EXHAUST VENT (PER CODE) TO VENT SHIELD MEMBRANE" AT ALL ROOF VALLEYS BELOW ROOFING �'��� � �-�,��.j_`; ,, P�:.,
<br /> � THRU ROOF OR SIDEWALL. FELT AND SHINGLES. r .. �
<br /> ��T
<br /> 1� ACRYLIC TUB IN TILE COVERED PLATFORM. PLATFORM PERMIT DRAWINGS � � � � � � �
<br /> SHALL BE TILE OVER TILE BACKER BOARD OVER WATERPROOF This note a lies onl to the architectural drawin re ared b Carl J. Colson - The Builder shall be res onsible for develo in construction details necessar The Architect has not been contracted to erform Construction Administra'tion ��
<br /> PP Y 9 P P Y P P 9 Y P
<br /> MEMBRANE OVER 3/4�� EXT. PLYWOOD OVER 2 x 4 STUDS & Architect PLLC for Ci+�Builders NW (the Owner/Dzveloper/Builder) for the Citv Lights to cons'truct a weathertight, durable building. services or Construction Observation services for this project and is not liable
<br /> JOISTS � 16�� O.C. - TILE SELECTION BY BUILDER. single-family residzntial development project ai 9909 2nd Ave W. Everett. WA. All flashing, weatherproofing, roofing, and waterproofing details and or responsible for determining adequacy of construction of building emelope
<br /> This architzctural drawing is prepared as a part of the Permit Set of drawings (along construction of these detail assemblies are the full and camplete or details.
<br /> 14. ONE-PIECE SHOWER W ACRYLIC SHOWER PAN & with structural drawin s rovided b structural en inezr for 'the Owner Develo er Builder responsib°lity of the Owner/Developer/Builder and these details shall be Tne Owner�Developer/Builder shall be responsible for inspecting and verifying
<br /> � � 9 P Y 9 ) � P � � � �
<br /> SAFETY GLASS - SELECTION BY BUILDER. COORDINATE for this project only. All de'tails, notes, and drawings shown are for Permit purposes only constructed per manufacturer requirements, building code requirements, and that all flashing, weatherproofing, roofing, and waterproofing details are ouilt
<br /> and do not consti'tute the full s2t of details r2quired to construct this project accepted Industry Standards for performance. correctly and mee+ Owner�Developer�Builder approval and accepted industry �
<br /> FRAMING REQUIREMENTS W/ MANUF. REQ'D. DIMENSIONS. standards oefore being covered by subsequent construction work. O
<br /> 0