� 22'-0"
<br /> 8'-8" 13'-4" ±
<br /> 5'-1" 3'-7" 7'-0" � 6'-4"
<br /> 20 �
<br /> 2'-6" � 10'-10" �
<br /> � F — — — — — — �
<br /> � �� �
<br /> � � � — — ;,•
<br /> O � EGRESS � - - - - - SL� OPE SLOPE I
<br /> WINDOWS
<br /> � 7-IN-12 � 7-IN-� I .
<br /> EGRESS BUILT-IN � I BIRD BLOCK VENTING AT w (
<br /> > I
<br /> WINDOWS SHELVES i z I EAVES (TYP) � I
<br /> o � HIGH `�'
<br /> � �iN WINDOWS � I I .
<br /> i GUTT RISHANDMETAL �
<br /> `� Bedroom #1 "' Bedroom #2 `� � ^
<br /> �
<br /> 0 10'-8" x 10'-6" 10'-0" x 11'-7" DOWNSPOUTS (TYPICAL). Q I
<br /> � HIGH SEE POWER PLAN SHEETS OO COORD. DOWNSPOUT I
<br /> o WINDOWS FOR SMOKE DETECTOR N I LOCATION W/ CIVIL I ,
<br /> O LOCATIONS (TYP) � I I DRAWINGS .
<br /> � 7,_6�„ � � z LINE OF EXTERIOR WALLS � z � CARL J. COLSON — ARCHITECT PLLC
<br /> � 2 � i � BELOW (TYP) � I I
<br /> � ,, 4�-„��� � � I � � 2 3 6 2 3 2 0 t h A V E N U E W B O T H E L L,
<br /> `��-6 2� o �\ i 2 a n�� R I D G E V E N T � WASHINGTON 98021 (425) 806�3'703 _ �
<br /> � �� I (
<br /> �` � �;� -
<br /> � I� — / N I
<br /> I PAIR `�� � 2668 I ATTIC AREA w I �
<br /> 2668 � ��'� — — — — — �- 826 s.F. o z I PROJECT: .
<br /> �- �� � � , � I � � � � .
<br /> � � - - - - - - - - h� ��'�, 5 -4 `�
<br /> � N � I � �
<br /> �,,._ � � ��� I �1 �1 �lt�
<br /> � 7'-10" FLASH CPERL NDUSTRY •
<br /> 0 26 8 I � SLOPE SLOPE _
<br /> i �, '� � � O STANDARDS. INSTALL I I
<br /> o � � � ' FLUE TO HEIGHT AS I 7-IN-12 7-IN-12 I s .
<br /> � 0 7'-6" ��-��� ��� '-rfir '
<br /> N A z 12 3 � _ _ REQ'D. BY CODE I I ��� l� �� � �T
<br /> I �.J y
<br /> a�
<br /> x
<br /> � � X RAME FOR 5 � j
<br /> � �
<br /> � � .
<br /> � 1 O � HE GHT WALL � I ROOF FRAMING W FALL PROTECTION I a
<br /> N - PLUMBING � � �; PRE-ENGINEERED WOOD W CONTRACTOR SHALL INSTALL �S1A�L����� •
<br /> � DRY WASH VENT ROOF TRUSSES � 24" O.C. � ROOF SAFETY ANCHORS
<br /> `V FRAME END WALL OF
<br /> WITH OVERFRAMING AT � PER CODE IF REQUIRED
<br /> 6�� WALL 5' 5' 0" 4'-6° �
<br /> � 1' 0" � – _ TUB 4" HIGHER THAN INDICATED AREAS. ROOF � (FASTENED TO ROOF I ���9 ZriC� t`�VeriLle W
<br /> I � � ONE PIECE TUB (DO �
<br /> 4'-0" �N 3' 8" 1 -8' 4'-2" -� NOT EXTEND WALL TRUSS MANUFACTURER WILL � TRUSS/FRAMING) FOR
<br /> � � "' TO CEILING) I PROVIDE ROOF TRUSS Q PROTECTION OF WORKERS I EVere�t WA 9g2O4
<br /> �- - - - - - DN HIGH I FRAMING PLAN (TYPICAL) ON ROOF I �
<br /> N PAIR WIND WS _ I
<br /> N I ROOF VENTING ROOF OVERHANGS
<br /> 2668 _N � � OO � I I SHINGLE-OVER RIDGE VENTS. ALL ROOF OVERHANGS I �
<br /> - � � � IF ATTIC ACCESS I SEE ROOF VENTING (EAVES AND RAKES) ARE I �
<br /> FUR ACE FLUE .. HATCH WON'T FIT IN CALCULATIONS FOR MIN. I CLIENT.
<br /> FROM BELOW q��� —I CLOSEi BECAUSE OF I ROOF VENTING 16", UNLESS NOTED
<br /> CHIMNEY FLUE I ACCES I ROOF TRUSS LAYOUT, I OTHERWISE T� ,1 �, T
<br /> � INSTALL IT IN MAW I REQUIREMENTS I I Cl� 1�l�ll�erS 1VW ,
<br /> o � FROM BELOW 2668 — I � BATHROOM ( I I 410148th St. 1V�
<br /> i i ATTIC ACCESS 53 �
<br /> x, o SEE SHEET A-4.1 �L
<br /> �� FOR STAIR & I SEE UPPER LEVEL FLOOR I Arlin On,V�JA 9�223 .
<br /> I I PLAN FOR LOCATION OF I �
<br /> - FRAME`�OF�5'� 6 o HANDRAIL I ATTIC ACCESS HA T C H E S I I
<br /> CONSTRUCTION
<br /> NIGH N INFORMATION I LAUNDRY ROOM I
<br /> WINDOWs - SEE LEVEL 2 PLAN I OTHERWISE I �
<br /> 0'-6" 4'-0" 3'-2" - ELEDVATIONS FOR I I �T ^
<br /> H ROOF / ROOF SLOPE I I I I � ��1 �Y ��� � �
<br /> lYlaSte� BeClr00111 �i`� INFORMATION OVER � I I �
<br /> '' PORCH � GROUND Z � ^
<br /> � o _ FLOOR BELOW � I ���� � � ,�"
<br /> �,� j 13'-2" x 14'-6" ��� i � I � I W v��
<br /> I � SEE POWER PLAN SHEETS FOR ;,� � �
<br /> � � � � � � ��1 �!
<br /> � � SMOKE DETECTOR LOCATIONS j
<br /> ��P� (-(- I \ I Q I .
<br /> � 2'-1" � 6'-10" � 2'-1° 66 SLOPE SLOPE — � •
<br /> SHELVES WINDOW EGRESS SHELVES � —! 7–�N–�2 7=1N-12 — � ,
<br /> � d- s�T WINDOWS O — � _
<br /> � — — — — �
<br /> 20 OE
<br /> 6'-0" 6'-0" 2'-1' 3'-9"
<br /> 2'-2" 1 2'-0" 5'-10"
<br /> 20'-0" ._
<br /> - "�;' ` �;+,f �� �-
<br /> ❑ � : �i [' r'1F��:7�4."�F� .•'� .., .
<br /> 1 r ; _.
<br /> 0 1� � ryj.
<br /> �T e /� � ��1 �J ��� � � � � � � � � ��l �l �
<br /> � ��l �l ��� � � . ����� � � �L�lN ,� _ , „ � y��#y � ���t�Y?1� .
<br /> SCALE 1 /4 — 1 -0 �;_ ,.� ���� r}x��u��f,,�{ r�
<br /> SCALE 1 /4" = 1 '-0" REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION PLANS AND ALL FRAMING PLANS (TYP) ��--�- 1� '
<br /> REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION PLANS AND ALL FRAMING PLANS (TYP) �
<br /> NOTES TO LEVEL 3 FLOOR PLAN ROOF GENERAL NOTES ROOF GUTTERS
<br /> NOTE: THE TERM "BUILDER" REFERS TO THE DEVELOPER ATTIC VENTING CALCULATIONS PERMIT SET NOTIFICATION .
<br /> WHOSE RESPONSIBILITY INCLUDES THAT OF GENERAL THE CONTRACTOR SHALL REVIEW ALL ROOFING AND ROOFING INSTALL ALUMINUM GUTTERS AND DOWNSPOUTS AT LOCATIONS
<br /> 1� STAINED HARDWOOD PLYWOOD VENEER (TO MATCH FLASHING DETAILS WITH ROOFING MANUFACTURER. CONTRACTOR SHOWN ON ROOF PLAN AND BUILDING ELEVATIONS. PROVIDE THE FOLLOWING CALCULATIONS PROVIDE THE "MINIMUM" VENTING AS This set of drawings is being issued as a Permit Set and
<br /> CONTRACT�R. REQUIRED BY THE 2006 INTERNATIONAL RESIDENTIAL CODE. THIS CODE is subject to change and adding of additional drawings
<br /> THESE NOTES ARE FOR THE UPPER FLOOR PLAN AT ALL STAIR RAILINGS) OR PTD. MDO AT WINDOW SEAT. WINDOW SHALL BE RESPONSIBLE FOR ALL ROOF ASSEMBLY RND BASKET STRAINER LEAFGUARDS IN GUTTERS AT TOP OF ALL
<br /> SEAT SUPPORT SHALL BE 3 4" PLYWOOD OVER 2x4 STUD ROOFING DETAILS IN ORDER TO ACHIEVE A WEATHERPROOF DOWNSPOUTS. ALL DOWNSPOUTS SHALL DRAIN INTO BELOW ALLOWS AREA OF VENTS REQUIRED TO BE 1/300TH OF ROOF AREA IF or information as required by review by City of Everett
<br /> UNITS. ALL NOTES MAY NOT APPLY TO EACH UNIT. �
<br /> FRAMING AND JOISTS � 16" O.C.. PI.ATFORM OF WINDOW ROOFING ASSEMBLY. GRADE DRAINAGE SYSTEM . CONTRACTOR TO COORDINATE THIS 50% OF VENTS ARE AT EAVE AND 50� OF VENTS ARE AT RIDGE AND Building Department. ,
<br /> ITEM PRIOR TO FOUNDATION WORK. CONTRACTOR SHALL IF A VAPOR BARRIER IS INSTALLED ON THE WARM SIDE OF ATTIC DO NOT USE THIS DRAWING FOR 'g�
<br /> TOILET CLEARANCES SHALL BE 15" FROM CENTER OF FIXTURE SEAT SHALL BE 20" ABOVE FINISH FLOOR. ROOFING MATERIALS COORDINATE PAINT COLOR FOR GUTTERS & DOWNSPOUTS iNsu�a,rioN. CONSTRUCTION UNLESS THIS DRAWING HAS
<br /> TO ADJACENT WALL OR COUNTERTOP. MIN. 30" CLEAR 1� BUILT-IN SHELVES ABOVE SOAKING TUB. PAINTED 3/4" WITH OWNER. PROVIDE AND INSTALL SCREENED GUTfER A CITY OF EVERETT BUILDING DEPARTMENT "
<br /> BETWEEN SIDE OR END WALL AND COUNTERTOP WITH TOILET MDO W. WOOD TRIM AT SHELF EDGE. REFER TO BUILDING SECTIONS FOR ADDITIONAL ROOFING GUARDS AT ALL GUTTERS. ATTIC VENTING SHALL BE ACCOMPLISHED WITH BIRDBLOCK
<br /> FIXTURE AT MIDPOINT. 1� LOCATION OF FIREPLACE EXHAUST / INTAKE FLUE. MATERIAL NOTES AND TYPES. EAVE VENTS AND SHINGLE-OVER RIDGE VENTS. BIRD BLOCK VENTS ��APPROVED�� STAMP UPON COMPLETION OF
<br /> COORD. W/ LOCATION OF FIREPLACE BELOW AND ROOF ATTIC ACCESS HATCHES ARE BASED ON (3) 2-1/2" DIAMETER HOLES PER VENT BLOCK (5.2 THE PERMIT REVIEW PROCESS. �
<br /> � LINE OF EXTERIOR WALL BELOW. REFER TO MAIN LEVEL FRAMING ABOVE. ROOF FRAMING PROVIDE INSULATED ATTIC ACCESS HATCH AT LOCATIONS SQ. INCHES PER LIN. FT.). Do not use for bidding or estimating purposes unless �
<br /> FLOOR PLAN FOR LOCATION AND INFORMATION. 1� BUILT-IN SHELVES: PAINTED 3/4" MDO W. W�OD TRIM
<br /> � LOCATION OF FLUE FROM FURNACE BELOW (IF FORCED AT SHELF EDGE. FIRST SHELF TO BE AT 8" ABOVE FLOOR. REFER TO STRUCTURAL FRAMING DRAWINGS FOR ROOF SHOWN ON UPPER LEVEL FLOOR PLAN. authorized by Owner � Developer. Developer � Builder
<br /> AIR HEATING SYSTEM IS USED). BUILDER TO COORDINATE THIS TOP OF SHELF ENCLOSURE TO BE AT 7'-0" ABOVE FLOOR. FRAMING INFORMATION. ATTIC ACCESS HATCHES IN 1 HR. CEILING SHALL HAVE A 1 PLAN TYPE D ATTIC VENTING CALCULATIONS shall be responsible for construction crews are supplied
<br /> ITEM WITH FRAMER PRIOR TO FRAMING. HR. FIRE RATING (IF 1 HR. CEILINGS ARE SPECIFIED FOR THIS (THE FOLLOWINC CALCULATIONS ARE FOR THE MINIMUM ALLOWABLE with all approved qnd most current construction
<br /> COORD. SHELF HEAD W/ WINDOW TRIM. ROOFTOP PENETRATIONS PROJECT) VENTS. SEE ROOF PLAN FOR LOCATION OF VENTS. CONTRACTOR SHALL documents.
<br /> � WASHER & DRYER IN LAUNDRY ROOM. WASHER SHALL 1� STOP CLOSET ROD/SHELF � AREA OF WINDOW IN
<br /> BE INSTALLED W/ FLOODSAVER DRAINLESS BASE PROTECTION MASTER BEDROOM CLOSEi�. INSTALL WINDOW SEAT BELOW NO PLUMBING VENT STACKS OR EXHAUST VENTS WILL BE ATTIC ACCESS HATCHES SHALL BE 22" x 30" (MIN. SIZE) INSTALL VENTING TO MEET THE FOLLOWING MINIMUM REQUIREMENTS.
<br /> PAN (WWW.FLOODSAVER.COM) AND AN ELECTRONIC WASHER WINDOW. ALLOWED ON FRONT PORTION OF BUILDIfJG ROOF FACING THE AND SHALL HAVE 30" MINIMUM UNOBSTRUCTED HEADROOM IN ALL EAVE VENTING SHALL BE DISTRIBUTED EV�NLY TO ASSURE � 4-ts-os PLAN B & C ISSUED FOR PERMIT
<br /> FLOOD STOP SYSTEM (SAFEHOMEPRODUCTS.COM). DO NOT 2� LINE OF ROOF ABOVE. REFER TO ROOF PLAN FOR ALL STREET. ALL RO�F-fOP PENETRATIONS, PIPES, VENT STACKS Al-I�IC ABOVE THE OPENING. PROPER AIR FLOW THROUGH ALL PORTIONS OF THE ATTIC AREA. BIRD �
<br /> USE FLOODSAVER PAN WITH DRAIN OR RIDGES. COORDINATE ROOF INFORMATION. SHALL BE FLASHED ACCORDING TO ACCEPTABLE INDUSTRY
<br /> COORDINATE OPENING WITH ROOF FRAMING. BLOCK VENTS SHALL BE EVENLY DISTRIBUTED TO OBTAIN PROPER AIR 2 4-28-08 PIAN A ISSUED fOR PERMIT ,;
<br /> PLUMBING AND VENTING REQUIREMENTS WITH MANUFACTURER. 2� SURFACE OF ROOF BELOW OVER PORCH OR EYEBROW STANDARDS. RESPONSIBILITY FOR ALL ROOFTOP FLASHING FLOW IN ATTIC SPACE):
<br /> DO NOT VENT LAUNDRY VENT OR DRYER VENT THRU FRONT ROOF OVER WINDOW BELOW OR GARAGE ENTRY. SEE DETAILS SHALL BE WITH GENERAL CONTRACTOR / ROOFING SKYLIGHTS (IF SHOWN ON PLANS) _3 5-5-08 PLAN D ISSUED FOR PERMIT
<br /> WALL OF RESIDENCE. BUILDING ELEVATION DRAWINGS. SUBCONTRACTOR. INSTALL SKLIGHTS ON PRESSURE TREATED 2x4 WOOD CURBS PLAN TYPE D AT-I-IC VENT CALC�S
<br /> AND INSTALL WITH METAL FLASHING PER SKYLIGHT
<br /> � 36" HIGH STAIR RAILING OR HALF-WALL W/ WOOD CAP. 2� 36" HIGH COUNTER W/ PLASTIC LAMINATE TOP (W/ MANUFACTURERS REQUIREMENTS. SKYLIGHT GLAZING SHALL BE 1) ROOF AREA = 826 S.F. •
<br /> SEE STAIR NOTES FOR GUARDRAIL INFORMATION.. LAUNDRY SINK, IF SHOWN) IN LAUNDRY ROOM. ROOF ATTIC VENTING LAMINATED SAFETY GLASS. 2) VENT AREA REQUIRED ?
<br /> � OPEN TO STAIRS BELOW. 2� LINE OF P�RCH COLUMNS BELOW. SEE MAIN LEVEL (SEE ATTIC VENTING CALCULATIONS FOR MIN. NUMBER OF 826 DIVIDED BY 300 = 2.76 S.F. NR. DATE REVISION
<br /> � ONE-PIECE ACRYLIC TUB/SHOWER ENCLOSURE. FLOOR PLAN FOR INFORMATION VENTS) SKYLIGHT WELLS (IF SHOWN ON PLANS) 3) DISTRIBUTION OF VENTS *C*O*P*Y*R*I*G*H*T*
<br /> � ONE PIECE WIRE CLOSET ROD AND SHELF - TYPICAL AT 2� LINE OF STEPS AT FLOOR BELOW. ALL EAVES SHALL HAVE BIRD BLOCK EAVE VENTS BETWEEN PROVIDE FLARED SKYLIGHT OPENING AT CEILING LEVEL WHERE 50� � ROOF = 1.38 S.F.
<br /> ALL CLOSETS. 25.� FRAME FLOOR OF LINEN CLOSET TO BE SLOPWG TO EXPOSED RA�I"ER TAILS. ALL ROOF RIDGES SHALL HAVE SKYLIGHTS ARE INDICATED ON FLOOR AND ROOF PIANS. 50% � EAVES = 1.38 S.F. These documents,the ideas and designs incorporated herein as an
<br /> � ADJUSTABLE WIRE SHELVES AT LINEN AND STORAGE ALLOW MAX. REQUIRED HEADROOM AT STAIRS BELOW. "SHINGLE-OVER" ROOF RIDGE VENTS. A�(TIC VENTILATION: NET SKYLIGHT WELL WALLS SHF�LL BE PAINTED 1/2" GWB OVER 2 4) NUMBER OF VENTS
<br /> CLOSETS. BUILDER TO SELECT NUMBER AND HEIGHTS OF instrument of service and shall remain the property of Carl J.Colson-
<br /> 26.) CORNER OF STAIRWAY OPENING (WITH LEDGE) TO BE AT FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 150's x 6 STUD FRAMWG � 16" O.C. WITH R-21 BATT EAVE VENTS (BIRD BLOCK): 1.38 S.F = 199 SQ. IN.
<br /> SHELVES. 45' ANGLE AS SHOWN. FRAME FLAT LEDGE TO BE ABOVE � � � Architect PLLC and are solely for use on the residential project(City
<br /> OF THE AREA OF THE SPACE VENTILATED. A VAPOR BARRIER INSULATION. BOTTOM LENGTH OF SKYLIGHT WELL SHALL BE DIVIDED BY 5.2 SQ. IN. /L.F. = 38.26 LIN. FT. OF BIRD Lights)on 2nd Ave.W,Everett,WA. Tbese files may notbe used on
<br /> � SKYLIGHT ABOVE. REFER TO ROOF PLAN AND WINDQW ADJACENT HANDRAILS. (P.V.A, PAINT) WILL BE INSTALLED ON THE WARM SIDE OF 4'-0" MINIMUM OR AS DIRECTED BY BUILDER. BLOCK VENTS �
<br /> SCHEDULE FOR INFORMATION. 27). LINE OF EXTERIOR FACE OF WALL BELOW. ROOF RIDGE VENTS: 1.38 S.F. = 199 SQ. IN. DIVIDED BY any vther projects nor may they be transmitted eleetronicaliy without : ,
<br /> 10. ONE PIECE SINK-COUNTERTOP OR TILE COUNTERTOP ATTIC INSUL4TION. A MINIMUM OF 1" AIR SPACE SHALi_ BE express permission of architect.They are not to be usedby the client or L'
<br /> ---� � � PROVIDED BETWEEN THE WSULATION AND ROOF SHEATHING AT 10 SQ, IN./L.F. OF VENT = 19.9 LIN. FT. OF RIDGE VENT any otherparty or Qntity on this or other projects,in whole or part,or as
<br /> W/ MIRROR ABOVE AND WOOD CABINET BELOW AT ALL EAVE VENT LOCATIONS.
<br /> BATHROOMS (TYP�. SELECTION BY BUILDER. an extension to this project except by agreement in writing with
<br /> 1� INSULATED ATI�IC ACCESS HATCH. SEE NOTES ON ROOF R 00 F VALLEY F LAS H I N G appropriate t7nancial compensation to Carl J.Colson-Architect PLLC .
<br /> PLAN SHE�. Copyright 2008 Cari J.Colson-Architect PLLC, O ,
<br /> INSTALL CONTINUOUS 36" WIDE (MIN.) °GRACE ICE & WATER �.3"����, � � �:: �' '� ��° ��� Allrightsreserved
<br /> 1� META� DRYER EXHAUST VENT (PER CODE) TO VENT � -
<br /> THRU ROOF OR SIDEWALL SHIELD MEMBRANE" AT ALL ROOF VALLEYS BELOW ROOFING ,--�P,�-; s �--� -� �
<br /> 1� ACRYLIC TUB IN TILE COVERED PLATFORM. PLATFORM FELT AND SHINGLES. ���� �` "� `-� � r �J� � � '�� �1��
<br /> SHALL BE TILE OVER TILE BACKER BOARD OVER WATERPROOF � � ^ � � � �
<br /> MEMBRANE OVER 3/4" EXT. PLYWOOD OVER 2 x 4 STUDS & PERMIT DRAWINGS ��11 �
<br /> JOISTS � 16�� O.C. - TILE SELECTION BY BUILDER. Tr,�s note applies only to the architectural drawing prepared by Carl J. Colson – The Builder shall be responsible for developing construction details necessary The Architect has not been contracted to perform Construction Administration Q�.i�
<br /> 14. ONE-PIECE SHOWER W ACRYLIC SHOWER PAN & Architect PLC for Citv �uilders NW (the Owner/Developer/Builder) for the C� Lights to construct a weathertight, durable building. services or Construction Observation services for this project and is not liable
<br /> � � single–family residential development project at 9909 2�d Ave W Everett WA. All flashing, weatherproofing, roofing, and waterproofing details and or responsible for determining adequacy of construction of building znvelope :
<br /> SAFETY GLASS – SELECTION BY BUILDER. COORDINATE This architectural drawing is prepared as a part of the Permit Set of drawings (along construction of these detail assemblies are the full and complete or details. '�
<br /> with structural drawin s rovided b structural en ineer for tne Owner Develo er Builder responsibility of the Owner/Developer/9uilder and these details shall be The Owner�Developer/Builder shall be responsible for inspecting and verifying ) .
<br /> FRAMING REQUIREMENTS W/ MANUF. REQ'D. DIMENSIONS. fa� thi� project only. All details, n tes, and drawngs shown are for P�mit puPrp ses only constructed pzr manufacturer requirements, building code rzquirements, and that ali flashing, weatherproofing, roofing, and waterproafing details pre built o o x
<br /> and do not constitute the full set of details required to construct this project. accepted Industry Standards ior performance. correctly and meet Owner/Developer�Builder approval and accepted industry •
<br /> standards before being covered by subsequent construction work, O
<br /> 0
<br />
|