GENERAL NOTES
<br /> �'OR WINbOWS WITti OPERABLE OPENINGS M�ORE
<br /> TNAN 72" ABOVE Tl-IE F'INISHED GRADE OR �
<br /> SURFACE E3ELUW, THE LOWESl' PART OF THE L� �
<br /> CLEAR OPENING SHALL BE 24" MINIMUM ABOVE W I
<br /> THE �'LOOR. EXCEPTIONS: FULLY OPEN WINDOWS � I°-' '�
<br /> 24'-0" WFIERE A 4" SPHERE MAY NOT PASS THROUGH � M
<br /> 16'-10" '7'p2" PRUVIDE�PER ASTM\F 2090 R�R 12.3R� `-' () N
<br /> � � �
<br /> 8-� ' PROVIDE SA�ETY GLASS PER IRC R308. "
<br /> Od d
<br /> ° --�° SKYL.IGH7S T'0 BE DOUBLE PANEL, 5WATfER �
<br /> � 2� ��-�„ RESISTANT AI'PC20YED f21GID PLAS7IC, LAMINATED
<br /> 4'-0° � � 16� SA�`ETY GLASS, F'ULLY TEMPERED GLASS, � �
<br /> �,, f�EAT-STI2ENGTHENED GLA55, OR WIRED GLASS. � � N
<br /> ° I° D E C K I PROVIUE 4" MINI�fUM CURB (OR SELF FLASHING � � �°`;
<br /> 6x3 MIN LANDING � � AS.�EMBLY W1TH 3:12 MINIMUM PITCN OR PER � � �
<br /> '�� OPT, REPLACE y� � ..�. cn � � `� MANUFACTURER INSTRUC110NS). pd � Q
<br /> SLIDER WITH 6o SL DR SAF GL�� E T p �p � r�, � HOSE BIBBS TO BE BACKFLOW PREVEN�ION AND
<br /> �y�_�6°4°XO 7� MAX STEP c� J, � � ^ �aH �AX STEP I FREEZE RESI57ANT TYPE � c2S �
<br /> . �.� 5 SL�GL DR � � �
<br /> ,;,�,',,;;,�%s;,,��;�', ,, , o �
<br /> '"'�"'��''�����"'"'"'��'''�' '%�� ''%�'''%� AL1._HQLDOWNS. FRA�IING ANCHORS & SHEARWAI,� � �
<br /> ,, � ,��„��� ��
<br /> =,'� 31�"x 9" 24F'-V4 GLB f�x"� �ST" �� � (2)2x6 �2HF ;% � � � � NALING �' �, � �
<br /> I �,x�p�. ��� T � O , M U ST_BE INSPECTED BE.FORE C0�_RIhC. []
<br /> �� STAIRWAYS PER IRC R311.7 �
<br /> % ;;
<br /> i ;; ����' BR'G PLUMB. ;% UP 15 RISERS % I � _ �
<br /> � ;> WALL 2x6 STUDS % pg� ;; I "' � 36° MIN. STAIRWAY WIDTH. LANDIN�S SHALL � N
<br /> � % � � 16" O.C. %� " �
<br /> �� '� STUDS �% HAVE A 36" MINIMUM DI�IENSION IN THE � � z
<br /> �, .
<br /> DIRECTION OF TRAVEL. A LANDING IS NOT � W o
<br /> ; � n ;;
<br /> REQUIRED WHERE THERE IS A DOOR AT THE
<br /> I � � 2x6 J� WALL � � I I ',; -- � TOP OF AN IN7ERIOR FLIGHT OF STAIRS, 'C J ¢
<br /> ;% OPT. FULL '% f � rn d-
<br /> ; � I I � � %� �. o� INCLUDING STAIRS IN AN ENCLOSED GARAGE 'v� �
<br /> x � ¢ HT. WALL � � '; � , „ R-2 1 I N S U L P R O V I D E D 1 N E D O O R D O E S N O T S W I N G O V E R v 0 �n
<br /> " � �� ~ RECREATION RM 6x10 �2DF i i i i '' �� ` � 5-'° �
<br /> - ; o rn THE STAIRS. RISERS TO BE 7�" MAXIMUM 3 U �'
<br /> ' // Z ' HEIGf-IT AND TREADS TO BE 10 MINI�AUM 3 �"
<br /> � ;; w �
<br /> %;� z � OPTIONAL GUEST S ITE � � %� �'
<br /> I �, Q 4x6 COLUMN � � SINGLE ; __ __ % � ^ MSTR SUITE MSTR BATH DEPTFI, BO1N W11N A MAXIMUM VARIAl10N OF
<br /> . ( % � z BC46 TO BM TJI S , _�$tL_ �% FLASHING CAP OVER �fi". 7READS WITH SOLID RISERS TO HAVE �"
<br /> % � i � I % %� � R-30 INSUL. � � � �
<br /> ,, ,�.� �, _ z ---_____ ;, I /� MINIMUM TO 1Y MAX. NOSING OR 11" MINIMUM
<br /> � �i ; � J r� ��� � a ; cuEsr ;; i ✓ DEPTN. 4" SPHERE MAY NOT PASS THROUGH co 0
<br /> °' `�'I % wm INSTALL SMOKE ALAR�i �o� ' 1 STUD JSTS PER PLAN OPEN RISERS ON STAIRWAYS RISING MORE N N
<br /> '� �� TNAN 30". HANDRAIL REQUIRED IF 4 OR MORE o �
<br /> r' ;; Z IF DOOR IS INSTALLED ��-s`L ao � %% � � � RISERS TO BE INSTALLED BETWEEN 34"-38" N N
<br /> �n I �;, o p � �2 -��, "' 2s � �2x10 TRIM BAND
<br /> % � � i BR G WALL � 3�_g^ 3'-8" N � A60VE NOSING AND HAVE A 1Y -2 4 GRIP � � �
<br /> I ;; o Q d- 3x4 STUDS � SOLID BLK G FLUSH BM PER PLAN CONTINUOUS FOR THE FULL LEN�TH OF THE o � o
<br /> ;; , o � 16" O.C. (4}STUDS � x (� BR'G WALL , n FLIGhIT. REIURN ENDS TO WALL OR NEWEL • y: o
<br /> '' S 0 INSTAl1 2x10 B L O C K I N G B E'T W E E N S T U D S T O � m N
<br /> � � � ;� � ���'��� �������������������"� ���� � � sA � `�" � � SUPPOR7 HANDRAIL BRACKETS. FIREBLOCK
<br /> o Q
<br /> x � %; � � 4 ; (1)STUD � � PWDR ROOM WINDOW B E 1��N S 7 U D S�A T STRINGER, 6'-$" �11NIMUM o �
<br /> � '� STORAGE CLOSET ; 2 O ��„ ; � �=-� ` BEYOND VERIICAL HEAD CLEARANCE. PROTECT
<br /> "� %% � BATH � ; � I �3 x � ENCLOSED ACCESSIBLE UNDER STAIR WALLS
<br /> I ; ; �5� m � " i AND CEIUNG WI1N 1�" GWB.
<br /> ,�
<br /> 36" VAN. � ��
<br /> I �;;,;;,;;;%;;;,;,%,�'i�;;��%���%;%%%�%;��% �``' % I I �m �, FOYER % , 1� x 11� 1.9E N BUILD UP WATER _
<br /> � � �'��' � �%% �� ; I o� �� �AICROLLAM LVL ; DECK ' EGRESS WINDOWS PER R310 U
<br /> �� '� �' � CHANNIEL WATER�TO T� 2 F1NISNED 51LL 70 BE 44° MAXIMUM ABOVE FLOOR.
<br /> / DRAIN � FRONT NET OPENING TO BE 5.7 S.F. MINIMU�1 (5.0 S.F. �
<br /> o � , ,, � � � ;; I I�j� ; �, LI VI N G R M
<br /> N
<br /> i �; FURN HWT 4. ; % � (2)2x6 #2HF % I� � MINI�AUM AT GRADE
<br /> `V _� � _ —�f����%.,,.>;,,�,,_'%;,;� ,;;%%,%�T;�,,,�,,,'�%'� 28 �,. (.� � „ FLOOR), 20" MINIMUM WIDTH, �..
<br /> � _______ „ —— —-'——— � � _ ;, � & 24 MINIMUM NEIGHT.
<br /> " DBL WOOD �i��� � '% � `� 2x8 CAP '
<br /> ; ' o o ;; I s" o BATHROOM NOTES I�-�-
<br /> '' � FLoOR i 3 i R-21 INSUI.. , n
<br /> i,� �
<br /> � � i �� ¢�i ; �� -�. � >,� ,; OPEN RAIL W/2x2 � FIREBLOCK TUBS AND SHOWERS PER R302,11.
<br /> � � � � � I �� \ � � � �a M i� I � y � . V l
<br /> N i ;�,Z F k i % \ � TOP OF SLAB 3 � %; PICKETS SEE GUARDS 3D x30 MINI�IUM CLEAR SPACE IN SHOWER. 22"
<br /> i M-� ^"'��% 28�y aPTIONAL DOOR BLW TOP OF STEM 7'� ���- %;. '% 4x6 COLUMN NOTES PG 3 � Q
<br /> R �IINI�IUM W1DTH SNOWER DOOR TO OPEN OUTWARD
<br /> „ ,,�;, _ ,, » »
<br /> i i � __- 4x$ �2DF HDR �,�.T ������•l� � BACK WALL %'��� � � I BC4 TO BM ,�, 2x6 RAILS IF HINGED. 30 WIDE X 24 DEEP CLEAR SPACE C� N
<br /> " 7� �� � REQUIRED OUTSIDE SHOWER DOOR. ENCLOSURES (J w
<br /> � ` ��������� L�L ���� � � JSTS PER PLAN 2x4 PLATE ON BEAM UP 6� WI SHOWE �
<br /> � STEP 70 BE SAFEIY GLASS. NONA6SORBENT SURFACE o
<br /> ;;; DBL � S�_f� ���� �; � �—FLASHING CAP OVER TN R. USE CEMENT BOARD OR w �
<br /> � STUDS ��_4� $�_$d 3,_Q„ %, � �� CEMENT FIBER BOARD FOR TILE BACKING. VAPaR
<br /> I � %% I - -- 2x12 TRIM BAND BAF2RIER NOT PERI�ITTED BEHIND W.P. GWB AT (� �
<br /> ,. ��
<br /> %% '% I EXT. WALL. 2.5 GPM SHOWER FLOW RESTRICTOR. �
<br /> I �� 10J�" ;, " Q
<br /> � 11�" TJI 360 � 16" O.C. , 3'-3" 1 X� �FLUSH BM PER PLAN RESSUREwBALANCE OR�iHERMOSTAl1C MIXING (�
<br /> � ;% TYPICAL THROUGHOUT % x R-30 INSUL
<br /> �% 2x6 STUDS ;% � TYPE. 1.6 GAL PER FLUSH MAXIMUM TOILETS. 15"
<br /> � ; „ ,,�L 2x8 #2HF P.L JI I i
<br /> � — � � 16 O.C. ;, r� " 1 � °O G A R A G E P O R C H WP• DECK COAT'G CL.EAR SPACE REQUIRED, EACH 51DE FROM t OF
<br /> `� 1 �% 2x6 s�°S �;A R A G E , , � 16 O.C. o o/ 3/" P.T. PLYWOOD TOILET dc 21" CLEAR SPACE REQUIRED IN FRONT. W
<br /> � ;> � 16 O.C. O �� A '- INSTALL 2x10 BLOCKING FOR TOWEL BARS UP 48
<br /> o .<�I % 4" CONC. SLAB � 2x$ #2HF :; �—� i o , , � �
<br /> i ;;. P.T. LEbGER ;� , _ > I � � 2x6 STUDS 5-� TAPERED SHIM OVER ADOVE FL.00R OR BELOW SILL HEIGNT IF AT ,�J
<br /> �Jll ; SLOPE TO DOOR ; U <,. „ M
<br /> `� � DBL DBL '% � Q � � 16 O.C. 2x8 �2HF P.T. � 16 O.C. WINDOW. INSTALL BLOCKING FOR T.P. HOLDERS. �
<br /> , %: sru�s _(2)i3�" x t�%" 1.9E _ _ _ S1l1DS �;� �l �� �- � I� o GARAGE APPLIANCES
<br /> � O PILOTS
<br /> N ;'. MICROLLAM LVL FLUSH �r -�� r ,,. p v o W � , BURNERS, SWITCFIES UP 18" MINIMUM
<br /> � ', I ; � w z °- o � ABOVE FLOOR, U.L APPROVED APPLIANCES WI7H � O �
<br /> � I % 9,_6„ 9,_6„ �% �•�1 w o � � I A U T O S H U T O F F S W I T C H. I N S T A L L I M P A C T B OLLARD.
<br /> ;� s � I > o � � (�A P A R T I A L S E C T I 0 N T H R U ��C K D U C T S I N G A R A G E T O B E 2 6 G A U G E S 7 E E L (N O
<br /> i I %% TYPICAL JSTS W� Z %% � o � �� OPENINGS). INSTALL WATER HEATER ON A
<br /> d- ' � �� � � %� U � S C A L E: �§" = 1'-0" G A L V A N I Z E D S T E E L PA N WiTH DRAIN WHERE LEAK
<br /> � � �n ,� �
<br /> ;, �i ',
<br /> � I %% 6� x 161� 24F-V4 DF '��r�y ^�� � � � � . � �
<br /> i (4)S1UDS � _ _ .� �� (4)STUDS -� � "` ' CAU5E DAMAGE SE7 ELECIRIC WATER
<br /> �I DBL JSTS � � � �- ._ _ HEA1�R ON R--10 IN5ULATED INCOMPRESSIBLE ::.� z
<br /> �� BA5E. IN5TALL SEISMIC STRAPS WITHIN TOP J� AND � w�
<br /> ap � ---------------� xJ � �� RELDc�:tAiSOC[AILS.YS • �C.7
<br /> � �; 7'-0" MIN. CLR. Ix,�� % � x3�i-2i2Tt►g�rttEErs.�,v. g0'I70M Y (4 MINIMUM ABOVE CON7ROLS). wz
<br /> '% �'�� %' � L�r�toNr�s,wn�so2� PROVIDE PRESSURE RELIEF LINE 70 EXIERIOR. � I �N
<br /> E�EL FIRED APPLIANCES EXG FD 10D0 BTU/H `� r�
<br /> �, � ; TOP OF SLAB 6" � �� ' �v ���s��7s-=-'��3 (� <t-
<br /> C
<br /> � ' ; BLW TOP OF STEM '=—————— ————— " � � INPU7 PER 50 �U. FT OF GARAGF' VO_UME X �
<br /> "r %% �� BACK WALL LINE OF UPPER LEVEL � � o � ST2LCTURf1L R.�VIEW N �
<br /> �� ! r INSTALl. 2 SCREENED COMBUSTION AIR VEN7S O� �
<br /> o i, P3J " g• `�
<br /> � " ^� ; � i I THROUGH EXTERIOR WALL, ONE WITHIN 12" 0� �``'
<br /> N % 4X1O 2DF ��i.�.L�.._ I_�h.I C�'C'r�I J STUDS �;� N � TI1lS DRr\�;'I:�JG FiAS 13G£�!iLE}IIL1�IcD FOR a � }..
<br /> _ _ # Y r _ „ � �__ CEILING & ONE W17HIN 12 OF FLOOR. USE ¢�
<br /> � ��aUC�ruRn1,t��q�u�r.�l�y-rs oti�.Y s�Ex'r�ic NON-CLOSE- ABLE LOUVERED 12x12 WALL VENTS N a i ``'
<br /> f�, � 6�X 7� 0.H. GAR. DR. n7-rActit_D�c�rrLa a r��i o�ct��.c u�.t l�r t o v s. �-
<br /> TUD C 2��/ ' i _....._.,______._._. OR Sx18 FOUNDATION TYPE VENTS IN WAIl FOR A � r.v
<br /> CULTURED STONE ��. � �Y: �� � MAINI�iUM NET FREE AREA OF 1 SQ. IN, PER 4,000 w ��
<br /> VENEER TYPICAL '" 3 S BTU/H EACH VENT. � � N N
<br /> �r? _-� �Ys r� -r-�. ..�� _ ..�..._.
<br /> �on�o: #� �i i DATE d�Q (� �,.�►
<br /> 1 6 J�" 1 s'-3' �s Y' 3'-�0° �4" I �I „ �o,r>����o� �,�-cTs,c��.� G A R A G E F I R E S E P A R A T I O N Q � °Z
<br /> 19_O M A I N �L O�R P L A I V SCALE: Y = 1'-0" - -- �-- � OPENINGS FFlOM GARAGE INTO SLEEPING ROOM _� �z
<br /> � » 5'-0" 4 6 0 S Q. F 1: Fl R S T F L Q O R N 0 1' p E R M I T T E D. �O O R B E T W E E N G A R A G E A N D —c�
<br /> 813 �, � ��p �ppR RESIDENCE SHALL BE 1�" MINIMUM 7HICK SOtID �-- ��
<br /> 24'-0" • 813 SQ � TM� �� WOOD OR STEEL WITH SOLID OR HONEYCOMB o�
<br /> 2086 SQ. F? TriIRD FLOOR
<br /> ��E��R I C A L L E G G N D GAf�AGE &2DUCTS E ETRATING TH�EUWALLS OR
<br /> 410 SQ, FL �ARAGE SMOKE ALARM PER R314 & LISTED PER UL 217. CEIIJNGS SEPARA�ING 7HE DWELI..ING FROM 1NE
<br /> INSTALL PER HOUSEHOLD WARNING PROVISIONS OF GAftAGE SHALL BE N0. 26 GAGE SHEET STEEL
<br /> sA NFPA 72 & PER MFGR. SPECS. 110V HOUSEHOLD AND HAVE NO OPENINGS IN70 THE GARAGE. FILL
<br /> CURRENT W17H BATTERY BACKUP. INTERCONNECT AROUND OTNER PENE7RAllONS WITH APPROVED
<br /> EACH BEDROOM AND LEVEL MATERIAL SEPARATE 1HE GARAGE FROM TNE �
<br /> RESIDENCE AND ITS ATTIC AREA W1TH }�' GWB
<br /> 50� 50 CF�1 (MIN.) EXHAUST FAN - VENT TO EXIERIOR. INS7ALLED ON THE GARAGE SIDE. SEPARATE
<br /> ' ''"� �"' `�'���s� FROM HABITABLE ROOMS ABOVE WITH �' TYPE X 4�
<br /> �., v �.� q�...
<br /> I��������� ���' �������� CE��NGNASSEMBLY,�TN SUPPORTINGSSTRUCTURE 8
<br /> SHALL BE PR07ECTED WITH 1¢" GWB.
<br />
|