Laserfiche WebLink
BUILDING CODE 8. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE <br /> 2009 INTERNATIONAL BUILDING CODE 4. N0 STRUCTURAL MEMBER SHALL BE CUT OR T0 EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT D � <br /> NOTCHED UNLESS SPECIFICALLY DETAILED OR KNOWLEDGE, BUT WITHOUT GUARANTE=E OF ACCURACY. <br /> FLOOR LOAD APPROVED IN WRITING BY THE STRUCTURAL <br /> ENGINEER. WHERE ACTUAL CONDITIONS CONFLICT WITH THE <br /> DEAD LOAD : 12 psf DRAWINGS, THEY SHALL BE REPORTED TO THE ENGINEER <br /> LIVE LOAD: 40 psf SO THE PROPER REVISIONS MAY BE MADE. <br /> 5. PROVIDE PROPERLY SIZED WASHERS UNDER MODIFICATIONS TO CONSTRUCTION DETAILS SHALL NOT BE cn <br /> HEADS AND NUTS OF ALL BOLTS AND LAG <br /> ROOF LOAD SCREWS BEARING ON WOOD. MADE WITHOUT PRIOR WR)TTEN APPROVAL BY THE � � <br /> DEAD LOAD: 15 psf ENGINEER o �, <br /> FLAT ROOF SNOW LOAD: 25 psf ,� „ ,� 'c� � <br /> 6. PROVIDE 3 x3 x0.229 WASHERS AT ALL N <br /> SNOW EXPOSURE FACTOR (Ce): 1 .1 ANCHOR BOLTS. ' O � <br /> SNOW LOAD IMPORTANCE FACTOR (Is): 1 .0 N <br /> � �� N <br /> THERMAL FACTOR (Ct): 1 .1 7. BOLT HOLES SHALL BE NOMINAL DIAMETER OF � �i X <br /> D DESIGN DATA BOLT PLUS 1 #16" UNLESS NOTED OTHERWISE. w � <br /> S E PRE DRILLED � W� � <br /> WIN LAG BOLT PILOT HOLES HALL B •- W °' �, <br /> 1 . BASIC WIND SPEED: 85 MPH T0 60� OF THE NOMINAL DIAMETER OF THE LAG 1 /� / I I c I v � o� o <br /> 2. WIND IMPORTANCE FACTOR Iw : 1 .0 BOLT UNLESS NOTED OTHERWISE. S H E A R V V A L�. L� J C H E D U l�E ( C D /� ) � � � � <br /> � ) <br /> BUILDING CATEGORY: II �' <br /> S I L L P L A T E 8 c B O T T O M/T O P P L A T E � ° ; i' <br /> 3. WIND_EXPOSURE: B 8. ALL SILL PLATES SHALL BE BOLTED TO THE MARK SHEATHING EDGE NAILING FIF_LD NAILING CONN. Q FND CONN. � W � <br /> 4. Kzt - 1 .38 FOUNDATION WITH 5#8" MINIMU�M DIAMETER BOLTS , 5/8" � A.B: C�? 48" LTP4 C� 20": 0/C w <br /> 5. INTERNAL PRESSURE COEFFICIENT: NA SPACED AT A MAXIMUM OF 48 ON CENTER. � 3/8 CDX ONE 8d � 6" 0/C 8d @ 12" 0/C 0/C W/ 2x SILL W 2x BOTTOM � � <br /> 6. APPLICABLE WIND PRESSURE FOR BOLTS MUST BE EMBEDDED A MINiMUM OF 7" INTO � FACE � � � <br /> COMPONENTS AND CLADDING; NA CONCRETE OR MASONRY. SEE PLANS AND PLATE PLATE � <br /> : DETAILS FOR SPECIFIC REQUIREMENTS WHERE 3/8" CDX ONE 5/$�� � A.B; � 36" LTP4 C� 14" 0/C � <br /> � 8d C�? 4" 0/C 8d, C�? 12" 0/C 0/C W/ 2x SILL W/ 2x BOTTOM <br /> SESI M I C DESI GN DATA APPLICABLE. FACE PLATE PLATE <br /> 1 . SEISMIC IMPORTANCE FACTOR: 1 .0 <br /> SEISMIC USE GROUP: I 9. RIM JOIST IS TO BE 11 �4" LSL MINIMUM. - <br /> 2. SPECTRAL RESPONSE ACCELERATION (Ss): 123.2� G SHEARWALL NOTES --- <br /> 3. SITE CLASS: D (ASSUMED) 10. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL 1 . ALL STUDS, BLOCKING, TOP AND BOTTOM PLATES SHALL BE HEM-FIR N0. 2 UNLESS --- <br /> 4. SPECTRAL RESPONSE COEFFICIENTS (SDS): 83.O�G PARTITION WALLS AND SOLID BLOCKING UNDER NOTED OTHERWISE ON PLANS. ALL SHEATHING EDGES MUST BE BAGKED WITFi 2x OR WIDER ___ - <br /> 5. SEISMIC DESIGN CATEGORY: D PERPENDICUILAR PARTITION WALLS. FRAMING (SEE NOTE #3). --- <br /> 6. BASIC 'SEISMIC-FORCE-RESISTING SYSTEM: <br /> No. Dale By Revis(on <br /> SHEARWALLS 11 . CONTACT THIS OFFICE PRIOR TO MAKING ANY 2. SHEATHING MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY. ALL SHEARWALL <br /> 7. DESIGN BASE SHEAR: SEE CALCULATIONS CHANGES TO THESE DETAILS SHEATHING MUST EXTEND TO THE OUTISDE EDGE OF ALL HOLDOWN POSTS AND CORNERS, <br /> 8, SEISMIC RESPONSE COEFFICIENT (Cs): 0.089 AND T0 THE INSIDE EDGE OF FRAMING AROUND OPENINGS. <br /> 9. RESPONSE MODIFICATION FACTOR (R): 6.5 GENERAL 3. WHERE SHEATHING NAILING IS SHEARVVALL 3 AND GREATER, ALL FRAMING MEMBERS <br /> 10. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL G DG LI G FROM ABUTTING PANE�S SHALL NOT BE LESS TWAN A SINGLE <br /> FORCE PROCEDURE 1 . ALL MATERIALS AND WORKMANSHIP SHALL {�ECEIVIN E E NAI N <br /> CONFORM TO THE CONTRACT DRAWINGS. 3-INCH NOMINAL MEMBER. ADDITIONALLY, WHERE SHEARWALLS ARE SHEATHED ON BOTH `- <br /> FACES, ALL STUDS AND PLATES RECEIVING EDGE NAILING FROM BOTH FACES MUST BE A (� N <br /> 2. DURING THE CONSTRUCTION PERIOD THE SINGLE 3-INCH NOMINAL MEMBER OR PANEL JOINTS MUST BE STAGGERED. IN EACH OF W � <br /> CONTRACTOR SHALL BE RESPONSIBLE FOR THE THESE CASES 3x STUDS ARE REQUIRED UNLESS SPECIFICALLY NOTED OTHERWISE ON THE � � <br /> FR�M I N G LU M BER SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PLANS BY THE ENGINEER. FOR SHEARWALLS �3 AND #4, A 2x SILL PLATE MAY BE USED � <br /> 1 . FF�AMING LUMBER SHALL BE HEM-FIR N0. 2. PROVIDE ADEQUATE SHORING, BRACING, AND GUYS IF TWO TIMES THE NUMBER OF ANCHOR BOLTS REQUIRED BY THE SHEARWALL SCHEDULE _ � <br /> GRADES ARE TYPICAL UNLESS OTHERWISE NOTED ON IN ACCORDANCE WITH ALL NATIONAL, STATE, AND ARE USED AND ARE EVENLY SPACED (SEE 2003 IBC SECTION 2305.3.10). <br /> PLANS. LUMBER TO BE GRADE MARKED PER WCLIB LOCAL SAFETY ORDINANCES: ANY DEVIATION MUST W � <br /> SPECIFICATIONS. BE APPROVED IN WRITING PRIOR TO ERECTION. 4. SHEARWALL NAILING CRITERIA IS BASED ON TABLE 2306.4.1 OF THE INTERNATIONAL � � <br /> BUILDING CODE (FOR CDX) OR REPORT NER-124 (FOR OSB). VALUES ARE BASED ON � F- <br /> � 2. STRUCTURAL SHEATHING SHALL BE APA RATED 3. ALL EREGTION PROCEDURES SHALL CONFORM TO HEM-FIR N0. 2 FRAMING WITH COMMON NAILS. �- � <br /> PLYWOOD, EXPOSURt 1 SHEATHING CONFORMING TO OSHA STANDARDS. ANY DEVIATION MUST BE Q W <br /> EITHER COMMERCIAL STANDARDS P51 -83, APA APPROVED BY OSHA PRIOR TO ERECTION. 5. HOLDOWNS AND OTHER CONNECTIONS MAY BE REQUIRED AT THE ENDS OF MANY Z � <br /> PRP-108, OR VOLUNTARY PRODUCT STANDARD SHEARWALLS. SIZES AND LOCATIONS OF THESE CONNECTORS ARE INDICATED ON THE W <br /> PSE-92. PROVIDE A MINIMUM OF 3/8" EDGE 4. THE CONTRACTOR SHALL BE SOLELY PLANS. REFER TO THE APPROPRIATE DETAILS AND/OR HOLDOWN SCHEDULE FOR � � <br /> DISTANCE ON ALL NAILS AND Ys" EXPANSION JOINT RESPONSIBLE FOR ALL CONSTRUCTION PROCEDURES. ADDITIONAL INFORMATION REGARDING ANCHOR BOLTS, EMBEDMENT LENGTH, ETC. WHERE (2) . � W ' <br /> B E T W E E N A L L P A N E L E D G E S: M I N I M U M S H E A T H I N G � �,� �,-�;� -�� �� <br /> 2x s ARE USED AS A HOLDOWN POST, SHEARWALL EDGE NAILING MUST BE STAGGERED INTO � <br /> RE(�UIREMENTS ARE AS FOLLOWS: 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR M.��`,�;� ,,;�. t��,�,j <br /> COORDINATING THE WORK OF ALL TRADES AND EACH MEMBER OF THE POST. ,�,�,�,� . ,�,� <br /> � � r, : - �, �y,� <br /> ROOF SHEATHING TO BE 19 32" INT-APA SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES � � ' `'' � , � <br /> � 6. ANCHOR BOLTS MUST BE EMBEDDED A MINIMUM OF 7" INTO CONCRETE OR GROUTED ,��,, '`�� � � <br /> RATED PLYWOOD WITH EXTERIOR GLUE, P.I. SHALL BE CALLED TO THE ATTENTION OF THE „ „ � z ,, 7 `� <br /> E NGINEER AND BE RESOLVED PRIOR TO PROCEEDING CMU, AND SHALL BE PLACED TO PROVIDE A MINIMUM OF 2 COVER. PROVIDE 3 COVER ; ( ��� ,�r� � �� �.,�-� <br /> 4 0/2 0. N A I L W I T H 8 d N A I L S A T 6" O N (�OR CONCRETE CAST AGAINST SOIL. ' ` `' > ��,,� <br /> CENTER AT PANEL EDGES AND 12" ON WITH THE WORK. v� ��,� r �y ,t� � Y ,, <br /> CENTER AT INTERMEDIATE MEMBERS. 6. DRAWINGS INDICATE GENERAL AND TYPICAL 7. ALL MACHINE BOLTS SHALL BE ASTM A307 OR BETTER. HILTI KWIK BOLTS/SIMPSON �`� �� �'' "�� � �, <br /> . <br /> � >� �;�- <br /> SUB FLOORING TO BE �/4" TONGUE AND GROOVE DETAILS OF CONSTRUCTION. WHERE CONDITIONS TITEN HD BOLTS OF THE SAME DIAMETER AS SHOWN IN THE SHEARWALL SCHEDULE MAY BE <br /> C-D INT-APA RATED PLYWO�D OR OSB WITH ARE NOT SPECIFICALLY INDICATED BUT ARE OF SUBSTITUTED FOR ANCHOR BOLTS INTO EXISTING CONCRETE. BOLTS SHALL BE EMBEDDED A pra„,� BY ccc� <br /> EXTERIOR GLUE, P.I. 48/24. GLUE AND NAIL SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR MINIMUM OF 5" INTO EXISTING CONCRETE. cne�kea eY ccc <br /> DETAILS OF CONSTRUCTION SHALL BE USED °°te: oe-,2-,2 <br /> WITH 1Od NAILS AT 6" ON CENTER AT PANEL SUBJECT TO REVIEW BY THE ENGINEER. 8. ALL NAILS AND CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD (EXCEPT FOR �ob No. s871 <br /> EDGES AND 12" ON CENTER AT INTERMEDIATE BORITE TREATED WOOD) MUST BE HOT DIPPED GALVANIZED OR STAINLESS STEEL TO RESIST <br /> MEMBERS. 7. ALL DETAILS DESIGNATED AS STANDARD OR CORROSION. - <br /> TYPICAL SHALL OCCUR IN ADDITION T0 ANY OTHER Si'RUCi'URALHOI'ES/ <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.9.1 OF SPECIFIC DETAIL CALLED OUT. 9. WHERE 10d NAILS ARE SPACED AT 3" ON CENTER OR LESS, NAILS MUST BE STAGGERED. SHEARWALLSCNEDULE <br /> THE INTERNATIONAL BUILDING CODE UNLESS NOTED , <br /> OTHERWISE. USE COMMON NAILS THROUGHOUT 10. OSB OF EQUAL OR GREATER THICKNESS MAY BE SUBSTITUTED FOR CDX SPECIFIED IN <br /> UNLESS NOTED OTHERWISE. <br /> SHEARWALL SCHEDULE. <br /> ���''� �� ��/E��T�' �'1.0 <br /> ��1�I�ll�l��� �c��t ����i��' <br />