<br /> ARCHITECTURAL ABBREVIATIONS SYMBOLS LEGEND DRAWING INDEX PROPERTY INFORMATION _
<br /> - GENERAL PARCEL NUMBER: 00480200300100 11111111'
<br /> ANGLE L. LENGTH
<br /> & AND LAV LAVATORY North Arrow
<br /> AB ANCHOR BOLT LB LAG BOLT GO1 Cover Sheet LEGAL DESCRIPTION: INTERCITY DIV 1 BLK 003 D-00 - LOTS 1
<br /> THRU 6 TGW ALL LOT 11 & NELY 1/2 OF LOT 12& ALL LOTS 14 &
<br /> ADD ADDENDUM LS LANDSCAPING NORTH K E M A N
<br /> ACT ACOUSTICAL CEILING TILE LKR LOCKER G02 Project Information 15 TGW TH PTN VAC INTERCITY AVE LY BTW BLKS 2 & 3 OF SD
<br /> A.F.F. ABOVE FINISH FLOOR LVR LOUVER G03 Existing Site Survey
<br /> ALS AREA LIGHT STANDARD PLAT & LY ADJ TO SD PRTY PER CITY EV ORD NO 1530-88 AF NO
<br /> ALUM ALUMINUM MAT'L MATERIAL Dimensional Control 8901090031 ARCHITECTURE +
<br /> DESIGN
<br /> ANOD ANODIZED MAX MAXIMUM
<br /> MB MARKERBOARD _
<br /> BC BOTTOM OF CURB MECH MECHANICAL ( u Grid PARCEL NUMBER: 00480200301200
<br /> BD BOARD MED MEDIUM
<br /> �� HAZMAT www.dykeman.net 1716 West Marine View Drive
<br /> LEGAL DESCRIPTION: INTERCITY DIV 1 BLK 003 D-00 - SWLY 1/2 425.259.3161 (T) 2nd Floor/Everett,WA 98201
<br /> BLDG BUILDING MEZZ MEZZANINE
<br /> BLKG BLOCKING MFR MANUFACTURER 0 LOT 12 ALL LOT 13
<br /> B.M. BENCH MARK MH MANHOLE HZ1.01 Hazmat Cover Sheet and General Notes
<br /> E BM BEAM MIN MINIMUM HZ1 .10 Hazmat Duplex Floor Plans E
<br /> BOT BOTTOM MIR MIRROR AREA OF LOT: 3.02 ACRES
<br /> CONSULTANT:
<br /> BTU BRITISH THERMAL UNIT MISC MISCELLANEOUS
<br /> BTWN BETWEEN MTD MOUNTED Name Level Datum
<br /> MTL METAL Elevation
<br /> OR C CHANNEL
<br /> CB CATCH BASIN NA NOT APPLICABLE
<br /> CCTV CLOSED CIRCUIT TV NIC NOT IN CONTRACT Centerline Mark
<br /> CG CORNER GUARD NOM NOMINAL CIVIL
<br /> C.I.P. CAST IN PLACE NS NELSON STUD
<br /> CLG CEILING NTS NOT TO SCALESpot Elevation Crosshair 00.0 Cover Sheet CODE ANALYSIS
<br /> CLR CLEAR
<br /> CJ CONTROL JOINT OA OVERALL 00.1 Notes
<br /> CMU CONCRETE MASONRY UNIT OC ON CENTER C1.O Demolition TESC Plan
<br /> CONT CONTINUOUS 0.D. OVERFLOW DRAIN Spot Elevation-Target Filled E-1 MUO ZONE W/:
<br /> CORR CORRIDOR OD OUTSIDE DIAMETER C2.0 Drainage and Utility Plan SETBACK (ADJACENT TO 'R' ZONES) 15'
<br /> CS.J CONSTRUCTION JOINT OH OVERHEAD C2.1 Drainage Details BUILDING HEIGHT 28' AT 35' FROM
<br /> CSMT CASEMENT OPNG OPENING User Note Location & Label C2.2 Drainage Details PROPERTY LINE
<br /> CT CERAMIC TILE OPP OPPOSITE T
<br /> CTR CENTER OS OUTSIDE 03.0 Grading Plan PARKING (NOT SPECIFIC TO E-1 ZONE) 62 SPACES REQ'D AS
<br /> CENTERLINE C3.1 Grading Sections and Details THE
<br /> PIP POURED IN PLACEDETERMINED BY
<br /> DBL DOUBLE PL PROPERTY LINE
<br /> C4.0 Horizontal Control and Paving Plan PLANNING DIRECTOR
<br /> DFL DETAIL PLAS PLASTER
<br /> C4.1 Horizontal Control and Paving Details 73 SPACES PROVIDED REGISTRATION STAMP:
<br /> DF DRINKING FOUNTAIN PLYWD PLYWOOD
<br /> DIA DIAMETEREXISTING BUILDING:
<br /> PSF PER SQUARE FOOT - -
<br /> DIAGMDIAGONALMP.T. PRESSURECONSTRUCTION TYPE VB (NON-SPRINKLE
<br /> RED)
<br /> TREATED Drawing Callout EXISTING BUILDING AREA 8,730 SQ. FT.
<br /> DIM DIMENSION PVMT PAVEMENT
<br /> DISP DISPENSER PROPOSED ADDITION 5,580 SQ. FT. REGISTERED
<br /> 9739
<br /> DN DOWN R. RADIUS ARCHITECT
<br /> DP DAMPROOFING R.D. ROOF DRAIN TOTAL BUILDING AREA (PROPOSED) 14,310 SQ. FT.
<br /> DR DOOR REF REFERENCE A3.01 1B Exterior Elevation Callout LANDSCAPE (FULLY SPRINKLERED) /
<br /> DS DOWN SPOUT REQ' REFRIGERATOR J OCCUPANCY A-3 LIBRARY
<br /> DT DRAIN TILE REQ'D REQUIRED L1.0 Site Plan \ LLIGARDRSTH
<br /> ALLOWABLE BUILDING HEIGHT 40' STATE OF WASHINGTON
<br /> DWG DRAWING REV REVISEOOR REVISION 1A L2.0 Landscape Plan ALLOWABLE NUMBER OF STORIES 2
<br /> RM ROOM L2.1 Landscape Schedule and Details
<br /> EA EACH R.O. ROUGH OPENING /� p
<br /> EF EXHAUST FAN RCP REFLECTED CEILING PLAN TABLE 506.2 BASIC ALLOWABLE AREA NS = 6,000 SQ. FT.
<br /> L3.0 Irrigation Plan 51 = 24,000 SQ. FT.
<br /> EJ EXPANSION JOINT
<br /> 1D A5.01 16 Interior Elevation Callout PROJECT IDENTIFICATION: D
<br /> D EL ELEVATION SB SMART BOARD L3.1 Irrigation Legend and Details
<br /> ELEC ELECTRICAL SC SOLID COREale L3.2 Irrigation Details 506.2.1 SINGLE OCCUPANCY, 1 STORY
<br /> E.O.S. EDGE OF SLAB SECT SECTION 1C L3.3 Record Plans of Existing Irrigation System (For Reference Only) Aa = At + (Ns x If)
<br /> ENGR ENGINEER SF SQUARE FOOT L4.0 Site Details
<br /> EQ
<br /> EPQ EQUAL SHWR SHOWER
<br /> ELECTRICAL PANEL SHTG SHEATHINGOWERAa = 24,000 + (6,000 x .75) = 24,000 + 4,500 = 28,500 SQ. FT. ALLOWED Evergreen Branch
<br /> EQUIP EQUIPMENT SHT SHEET 1 / Al 01 Drawing Reference
<br /> ES EACH SIDE SIM SIMILAR 566.3 FRONTAGE INCREASE Library Expansion
<br /> EW EACH
<br /> SM SPEWAY SJ SHEET METAL JOINTEXW = L/F (>30' ALL SIDES) = 30, F/P = 1
<br /> (E) EXISTING
<br /> (E) EXPANSION SPEC T SPECIFICATION ARCHITECTURAL If - (1/1 - .25)W/30 = (1-.25)30/3 = .75
<br /> EXT EXTERIOR SQ SQUARE SIM FOR
<br /> SS STAINLESS STEEL a TOTAL BUILDING AREA = 14,717 GROSS SF
<br /> FA FIRE ALARM STD STANDARD IIIA101 Callout A0.00 1st Floor Demolition Plan
<br /> FBO FURNISHED BY OTHERS STL STEELTOTAL SITE AREA = 81,756 SF City of Everett
<br /> FD FLOOR
<br /> A0.01 1st Floor Demolition RCP BUILDING COVERAGE = 14,717 SF / 81,756 SF * 100 = 18.00%
<br /> FDN FOUNDATION ON STSTRUORCTSTRUCTURAL
<br /> STORAGE CTSTRUCTURAL A0.11 1st Floor Slab Plan PERVIOUS AREA = 19,497 SF / 81 ,756 SF * 100 = 23.85%
<br /> FE FIRE EXTINGUISHER SUSP SUSPENDED A1.00 Wall Types IMPERVIOUS AREA = 62,259 SF / 81 ,756 SF * 100 = 76.15%
<br /> _ FEC FIRE EXTINGUISHER CABINET I
<br /> �\ SIM
<br /> FF FINISH FLOOR T TEMPERED GLAZING ` 1 A1.01 1st Floor Plan
<br /> FFE FINISH FLOOR ELEVATION TO TOP OF CURB A101 Building Section AT
<br /> FIN FINISH TEL TELEPHONE A1 .02 1st Floor Furniture, Fixtures & Equipment
<br /> FL FLOOR T&G TONGUE AND GROOVE
<br /> FO FACE OF THK THICK A1.11 Mechanical Platform Plan FOC FACE OF CONCRETE TJ TOOL JOINT A1.21 Roof Plan 9512 Evergreen Way
<br /> FOF FACE OF FINISH TP TOP OF PAVEMENT ^ SIM Everett WA 98204
<br /> _
<br /> FOIC FURNISHED BY OWNER TYP TYPICAL JMIIIM\ A1.31 1st Floor RCP Wall Section
<br /> INSTALLED BY CONTRACTOR TOD TOP OF (MATERIAL) A101 A2.11 Exterior Elevations Code Analysis - Occupant Load
<br /> FO10 FURNISHED BY OWNER TOP TOP OF PARAPET
<br /> INSTALLED BY OWNER TOS TOP OF STRUCTURE A3.11 Building Sections
<br /> FOM FACE OF MASONRYRoom Occupant Load Occupant Load BID SET
<br /> FOS FACE OF STUD UNFIN UNFINISHED A3.12 Building Sections
<br /> FRT FIRE RETARDANT TREATED UNO UNLESS NOTED OTHERWISE /� SIM Number Name Area(SF) Factor Rounded
<br /> 1 A3.13 Building Sections O9/1 O/2018
<br /> FTG FOOTING Detail Section
<br /> FURR FURRING VB VAPOR BARRIER �10� A5.11 1st Floor Finish Plan Levell
<br /> 3 TABLE/CHAIR STORAGE 43 300 1
<br /> •
<br /> VERT VERTICAL A5.21 1st Floor Enlarged Finish Plans 4 CHILDREN'SCA ACTIVITYOROOM 641 0 91
<br /> GA GAUGE VEST VESTIBULE
<br /> GALE GALVANIZED VFY VERIFY A6.01 Enlarged Restroom Plans & Interior Elevations
<br /> GB GRAB BAR 6 CHILDREN'S STACKS 787 100 8 This drawing is:
<br /> GC GENERAL CONTRACTOR W/ WITH Building Element Tags A6.11 Interior Elevations 7 FAMILY SEATING 629 50 13 1. Copyright 2017 Dykeman, Inc. C
<br /> C GL GLASS WC WATER CLOSET 8 TEEN LOUNGE 597 50 12 2. TheArchitect's1Instrument of Professional Service.
<br /> GND GROUND WD WOOD '6.12 Interior Elevations
<br /> 9 ADULT EG 597 50 12 3. For use this projecttonly. Professional
<br /> sionalSe
<br /> 00 00 oo.00 KeynoteA7.10 Door, Window & Casework Schedules 19 ADULTEEN STACKS 389 100 4 writtenupermissiononthifor any otheruseArchitect's reproduction.
<br /> GVP GYPSUM VENEER ALASTER WF WIRE FLANGE Reference
<br /> GWB GYPSUM WALL BOARD WG WIRE GLASS
<br /> WH WATER HEATER '7.11 Door, Window & Foundation Details 11 REFERENCE 318 100 4 -
<br /> HB HOSE BIB W/O WITHOUT A7.12 Door, Window & Foundation Details 12 PUBLIC COMPUTING&COPIER 537 15 36 PROJECT NUMBER:
<br /> HC HANDICAP WP WATERPROOFING Area name 13 ADULT STACKS 846 100 9
<br /> HDWR HARDWARE WT WEIGHT Area Name&Square Footage A8.01 Exterior Details 14 LIVING ROOM 564 50 12 fol
<br /> HM HOLLOW METAL 150 SF 2017-008
<br /> '9.01 Interior Details 15 EVERGREEN ROOM A 663 7 95
<br /> HW HOT WATER
<br /> HVAC HEATING, VENTILATION ANDA10.01 Exterior Signage & Wayfinding 16 EVERGREEN ROOM B 667 7 96
<br /> AIR CONDITIONING Room Name&Number 17 TABLE&CHAIR STORAGE 54 300 1
<br /> A10.02 Interior Signage & Wayfinding18 GROUP STUDY A 142 15 10 REVISIONS:
<br /> INTEL INSULATION A10.03 Interior Signage & Wayfinding 19 GROUP STUDY B 142 15 10 MARK DATE DESCRIPTION
<br /> INT INTERIOR WS00 Wall Type
<br /> '10.04 Interior Signage & Wayfinding 20 LAPTOP BAR 160 15
<br /> 11
<br /> JAN JANITOR
<br /> 21 QUIET ROOM 233 15 16 2017.08.07 DD COST EST.
<br /> JT JOINT Al0.05 InterlOr Signage & Wayfinding 22 BRANCH MANAGER 146 100 2 2017.08.17 DD SUBMITTAL
<br /> JST JOIST (GA) Storefront Type A10.06 Interior Signage & Wayfinding
<br /> 23 SHARED OFFICE 241 100 3 2017.12.05 PERMIT SET
<br /> General Notes A10.07 Interior Signage & Wayfinding 24 STORYTIME STORAGE 45 300 1 2018.08.14 PERMIT SET
<br /> Ow) Door Number 27 SECURE K ROOM
<br /> ST°ORAGE 249 15 93 300 171 2018.09.10 BID SET
<br /> 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE THE WORK OF ALL
<br /> TRADES INVOLVED IN THE PROJECT AS PART OF THIS CONTRACT.
<br /> 2. DO NOT SCALE THESE DRAWINGS. DUE TO REPROGRAPHIC PROCESSES THESE29 ELEC. 51 300
<br /> DRAWINGS MAY NOT BE TO SCALE. CONTACT ARCHITECT FOR ANY NEEDED CAS Window Type 31 ELEC. 51 300 1
<br /> 32 JANITOR 95 300 1
<br /> CLARIFICATION.
<br /> 3. CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ALL STRUCTURAL 33 RISER 62 300
<br /> DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 0'-0" Ceiling Elevation from Floor Level 34 STORAGE 40 300 1
<br /> 4. CONTRACTOR SHALL PROVIDE A COMPLETE AND PROPER EXECUTION OF THE WORK AS
<br /> INDICATED ON ALL DRAWINGS AND SPECIFICATIONS. IF DISCREPANCIES IN LAYOUT, S1.01 Structural Notes and Drawing List 35 VOICE AND DATA SERVICES 312 300
<br /> DIMENSIONS, OR DETAILS ARE FOUND BETWEEN ARCHITECTURAL, STRUCTURAL, S1 .02 Statement of Structural and Testin 36 CIRCULATION MANAGER 127 100 2
<br /> MECHANICAL, ELECTRICAL, CIVIL OR LANDSCAPE DRAWINGS, CONTACT THE RA- Roof Assembly Type Inspectionsg 37 MAINTENANCE STORAGE 251 300 1
<br /> ARCHITECT IMMEDIATELY FOR CLARIFICATION BEFORE PROCEEDING. S2.01 Foundation Plan 38 WORKROOM 251 100 3
<br /> 5. REGULATIONS, STANDARDS, CONSTRUCTION, MATERIALS AND REQUIREMENTS FOR 52.02 Roof Framing Plan
<br /> INSTALLATION OF MATERIALS SHALL CONFORM AND BE GOVERNED BY THE EDITION OF MarkCasework Type S3.0139 SORTING AREA 717 100
<br /> THE CODE IDENTIFIED IN THE CODES SHEET OF THESE DRAWINGS. W H D Elevations 40 CIRCULATION 453 100 5
<br /> 6. REFERENCING DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT S4.01 Typical Concrete Details 34 11,314 494
<br /> B APPLICATION FOR DRAWINGS OR DETAILS. S4.02 Concrete & Masonry Details B
<br /> 7. MATERIALS AND FINISHES LISTED ON INTERIOR AND EXTERIOR ELEVATIONS ARE FOR Material Mark
<br /> S5.01 Typical Wood Details PROJECT TEAM:
<br /> GENERAL INFORMATION AND CONVENIENCE OF THE CONTRACTOR AND ARE
<br /> REFERENCED IN ADDITION TO MATERIALS AND FINISHES INDICATED OR SPECIFIED S5.02 Typical Roof Framing Details
<br /> ELSEWHERE IN THE DOCUMENTS. S5.03 Shear Wall Schedule and Details PRINCIPAL IN CHARGE: KGS
<br /> 8. HEIGHT DIMENSIONS ARE GIVEN FROM FINISHED SLAB WHERE INDICATED. OR Revisions
<br /> RELATIVE TO DATUM NOTED ON THE DRAWINGS. S5.06 Wood Details PROJECT MANAGER: 1
<br /> TPH
<br /> 9. N.I.C. EQUIPMENT IS FURNISHED AND INSTALLED BY OTHERS. CONTRACTOR IS S5.07 Wood Details PROJECT ARCHITECT:
<br /> tuber
<br /> RESPONSIBLE FOR COORDINATION INSTALLATION AND PERFORMING WORK AS 1 Revision Number S5.08 Wood DetailsVICINITY MAP
<br /> S6.01 Steel Details JOB CAPTAIN: 1 DDF
<br /> REQUIRED BY DETAILS OR SPECIFICATIONS FOR EQUIPMENT INSTALLATION.
<br /> 10. F.O.I.C. EQUIPMENT IS FURNISHED BY OTHERS AND INSTALLED AS PART OF THIS WORK. u KEYPLAN:
<br /> THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK AS REQUIRED FOR
<br /> INSTALLATION. '
<br /> STALLATI ON. Spec;ccs Wet
<br /> Naval Station Everett 11. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS FOR FIRE RATED WALLS, island Park 1O8 5t4
<br /> INCLUDING, BUT NOT LIMITED TO PIPING, DUCT, CONDUIT, ETC. WITH FIRE STOPPING
<br /> PER CODES THAT GOVERN THIS SET OF DOCUMENTS. BookendCoffee0
<br /> clintcn Company Everett Police-- t.L, .. tm�t;-
<br /> 12. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER MEMBRANE AT _ ��EvereDepartmentls
<br /> THE FLOOR SLAB, WALLS, AND ROOF. BACKER ROD, SEALANT AND OTHER APPROVED ,,. ,
<br /> MECHANICAL -
<br /> MEANS SHALL BE APPLIED CONTINUOUSLY AROUND ALL EXTERIOR DOORS AND
<br /> WINDOW PENETRATIONS AND OTHER AREAS OF POTENTIAL AIR INFILTRATION,
<br /> INCLUDING STRUCTURAL, MECHANICAL AND ELECTRICAL PENETRATIONS. THE MO.1 Cover Sheet
<br /> DAMAGE TO VAPOR BARRIER, OR REPLACE THEM
<br /> CONTRACTOR SHALL REPAIR ANY MO.2 Schedules m _
<br /> V4 r.�u�,n��,��
<br /> PRIOR TO COVER, AS INSULATIONE°. APPLICABLE CODES AND REFERENCES
<br /> AND SOUND IS INTENDED TO PROVIDE A CONTINUOUS ENVELOPE MO.3 Schedules A FobeS Nall
<br /> 13. THERMALs
<br /> AS INDICATED. Mukilteo
<br /> M0.4 Schedules ,, -
<br /> 14. ALL ADA TOILETS, URINALS, AND STALLS SHALL MEET THE REQUIREMENTS OF THE • AUTOMATIC FIRE DETECTION & SUPPRESSION SYSTEMS ORDINANCE NO. 1902-92
<br /> DOCUMENTS. ALL STANDARD(NON-ADA)TOILETS M1.0 Floor Demo Plan - HVAC w1
<br /> CODES THAT GOVERN THIS SET OF J, _ �' ',,
<br /> SHALL BE CENTERED IN STALLS OR PARTITIONS AS APPLICABLE, UNLESS OTHERWISE • INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION & WAC 51-50 M1.1 Mechanical Room Demo Plan - HVAC Boeing 0._ ,f
<br /> NOTED. • INTERNATIONAL EXISTING BUILDING CODE (IEBC), 2015 EDITION & WAC 51-50 M2.0 Floor Plan - Plumbing ,,-., p "° ,�
<br /> 15. WHERE EXTERIOR CONCRETE WALKS AND LANDINGS ABUT BUILDINGS,THEY SHALL BE ACCESSIBLE AND USABLE BUILDINGS & FACILITIES, ANSI '117.1-2009 & WAC 51 50-005 M3.0 Floor Plan - HVAC
<br /> SLOPED AWAY FROM THE BUILDING AS NOTED, BUT IN NO CASE LESS THAN .125"/12". •
<br /> Everett Public Library
<br /> INTERNATIONAL FIRE CODE (IFC), 2015 EDITION & WAC 51-54 M3.1 Mechanical Room Plans Everett
<br /> EvergreenPublic Lib
<br /> Sn
<br /> 16. MAINTAIN NOTED SLAB THICKNESS AT ALL RECESSED SLAB AREAS AND SLOPING • ( )
<br /> SLABS. • INTERNATIONAL MECHANICAL CODE (IMC), 2015 EDITION & WAC 51-52 M3.2 Floor Plan Piping _
<br /> • 17. ALL FOAM PLASTIC INSULATION TO COMPLY WITH THE SURFACE BURNING • NATIONAL ELECTRICAL CODE (NEC), 2014 EDITION & WAC 296-46B-010 M4.0 Details „ Y ° >E DRAWING TITLE:
<br /> CHARACTERISTICS DEFINED BY THE CODE THAT GOVERNS THIS SET OF DOCUMENTS. UNIFORM PLUMBING CODE UPC 2015 EDITION & WAC 51-56 & 51-57 M4.1 Loads and Diagrams m
<br /> 18. SPECIAL INSPECTIONS SHALL BE PROVIDED AS REQUIRED BY THE JURISDICTION THAT • (UPC), g
<br /> GOVERNS THIS SET OF DOCUMENTS. SEE SPECIFICATION SECTION 01 4523 FOR • WASHINGTON STATE ENERGY CODE (WSEC), 2015 EDITION & WAC 51-11 (C, R, APPENDIX) M4.2 Controls & Energy Code ..
<br /> ADDITIONAL INFORMATION. • CITY OF EVERETT DESIGN & CONSTRUCTION STANDARDS & SPECIFICATIONS M5.0 Sections Q
<br /> 19. DRAWING KEYNOTES DO NOT CORRELATE DIRECTLY TO INDIVIDUAL SPECIFICATION EVERETT STORMWATER MANAGEMENT MANUAL -
<br /> O ® F A
<br /> •
<br /> SECTIONS.
<br /> A 20. IT SHALL BE THE SPECIFIC DUTY AND RESPONSIBILITY OF EACH TRADE AND SUPPLIER • EVERETT MUNICIPAL CODE, TITLE 19 ZONING
<br /> ° Willis D. Project Information
<br /> TO EXAMINE ALL PROJECT DRAWINGS, DETAILS AND SPECIFICATIONS, AND TO
<br /> PROVIDE AND FURNISH PROPER EQUIPMENT, HARDWARE, FIXTURES, MATERIALS, ETC., Picnic Tucker
<br /> PoPicnicrth :, Community
<br /> L Lynnwood Mill Creek Park
<br /> PERTAINING TO THEIR PART OF THE WORK SHOWN OR LISTED IN ANY PART OF THESE Y }
<br /> DOCUMENTS. QUALITY CONTROL, ADVERSE MATERIAL REACTIONS, AND COMPLIANCE
<br /> a.
<br /> Martha Lake i`)
<br /> TO INDUSTRY STANDARD WORKMANSHIP ARE THE RESPONSIBILITY OF THE
<br /> CONTRACTOR. SCHEDULES ARE FOR THE CONVENIENCE OF THE CONTRACTOR TO ELECTRICAL C
<br /> ASSIST THEM IN UNDERSTANDING AND CONSTRUCTING THE PROJECT. ANY OMISSIONS A
<br /> I ctrical Cover Sheet r � pLynnwnodHignScnool - CITY Q� Ev'EIaETT DRAWING NUMBER:
<br /> OR CONTRADICTIONS IN THESE DOCUMENTS SHALL BE CALLED TO THE ATTENTION OF EO.00 E e �A1C
<br /> THE ARCHITECT PROIOR TO SUBMITTING A BID. BIDS RECEIVED SHALL BE CONSIDERED E1.00 Electrical Site Plan
<br /> T INCLUDE ALL ITEMS SHOWN AND/OR SPECIFIED OR SCHEDULED FOR A COMPLETE DEFERRED SUBMITTALS aertawvruF Alderwood Malin:,: �E V(E�VVGD FOR PERMIT
<br /> PROJECT. THE CONTRACTOR SHALL NOTE THAT THE WATERPROOFING DETAILS DO NOT E2.00 Lighting Plan
<br /> ALWAYS REFLECT THE ARCHITECTURAL DETAILS AND ARE INTENDED TO SUPPLEMENT
<br /> THE ARCHITECTURAL DETAILS NOT REPLACE THEM. INSTALLERS ARE TO BE CERTIFIED FIRE SPRINKLER E2.01 Lighting Control Plan
<br /> E3.00 Power and Systems Plan
<br /> BY MANUFACTURER'S APPROVED WARRANTY REQUIREMENTS. GO2
<br /> 21. BUILDING INSPECTION SHALL BE PERFORMED THROUGHOUT THE DURATION OF FIRE ALARM E3.01 Platform Power Plan
<br /> CONSTRUCTION. THE FREQUENCY OF INSPECTION IS IDENTIFIED IN THE CONTRACT. E4.00 Electrical Riser Diagram
<br /> INSPECTIONS WILL BE PERFORMED ON SITE. INSPECTIONS WILL BE DOCUMENTED AND
<br /> RECORDED AS DEEMED NECESSARY BY THE PROJECT ENGINEER. 6
<br /> 1 2 3 4 I 5
<br /> R
<br />
|