Laserfiche WebLink
I I 3 I I <br /> I Mk 111 <br /> EXTERIOR MOUNTED ANTENNA <br /> I 1 PROVIDE A " CONDUIT LEADING TOIIPPI- <br /> STRONG BOX #SB-24SSW 24" EXTERIOR MOUNTED ANTENNA DY K E M A N <br /> CITY O F EVE REIT PARKS & WEATHERPROOF ENCLOSURE PROVIDED BY <br /> HORIZON DISTRIBUTORS OR HD FOWLEERR L J CELL EQUIPMENT DATA REMOTE OR PROTECTED DEVICE <br /> CONNECTION TO LAND LINE FOR PHONE BARE COPPER GROUND WIRE ARCHITECTURE + DESIGN <br /> 1NH1RO COMMUNICATION <br /> NOTES RAINBIRD ESP-24-SITE-SAT CONTROLLERRECREATION STANDARDWITH ESP RECV CARD #01062 REMOTE <br /> CONTROL TECHNOLOGY - - GROUND ROD ASSEMBLY 6" VALVE BOX <br /> ESP-SITE-SAT24 www.d keman.net 1716 West Marine View Drive <br /> TERMINAL BOX WITH TERMINAL STRIPS 6" VALVE BOX FINISH GRADE v <br /> LEVITON 5280-W SURGE PROTECTION 425.254.3161 (T) 2nd Floor!Everett,WA 98201 <br /> INSTALLATION 0 UNIT SHALL BE WALL MOUNTED IN DESIGNATED a <br /> RAINBIRD - PT 3002 FLOW SENSOR Q LOCATION UNDER EAVE (SEE L3.0), BARE COPPER GROUND WIRE <br /> • Confirm mainline alignment, valve locations and laterals with owner before installation. TRANSMITTER AND PULSE DECODER = COORDINATE WITH ELECTRICAL CONTRACTOR <br /> • Paint/stake/mark the irrigation system following the diagrammatic design shown on the <br /> ,„� _ FOR POWER SUPPLY AND CONDUITS,int/starw,- _ , __ <br /> ,,,,„„4;,;. 4 1.4.-d- ,:g 4,4 <br /> plans before installation. I 1® <br /> c n WITH ARCHITECT PRIOR TO INSTALLATION GROUND <br /> • Mainline shall be buried 18" below grade, laterals shall be buried 15" min. below grade. ,F� ,,-4- -r�_, - �_4 <br /> ' � ROD <br /> • All lines shall be flushed prior to installation of sprinkler heads. Contractor shall <br /> coordinate with owner for verification prior to flush for owner to be present. I CLAMPS <br /> • Flush lines again before installing nozzles. MIN. 10-1 BARE COPPER <br /> • Zones shall be as indicated. ■I WEISMANDESIGNGROUP <br /> • Adjust system for optimum pressure, efficient distribution, and adjust head type or <br /> spacing for slopes as needed. <br /> LANDSCAPE 2329 E MADISON ST 206-322-1732 <br /> PIPE SPECIFICATIONS / <br /> 'CONSULTANTSEATTLE WA 98112 WW.WDGINC.COM <br /> / li <br /> W <br /> • Use HDPE pipe from meter to DCVA. <br /> • Mainlines and laterals shall be schedule 40 PVC. <br /> 8' COPPER CLAD <br /> • Mainlines 4" or greater are to be 200 PSI HDPE. <br /> • See Primer/Glue specs. FINISH GRADE OF CONCRETE PAVING7K GROUN <br /> MECHANICAL ______ <br /> • Valve boxes shall be installed per location on plans or as directed by owner, with lids, <br /> REGISTRATION STAMP: <br /> using extensions where necessary. l 4 (I I — I I <br /> • Top of lids shall be at finished grade. _ _ 10" PIT BOX <br /> • Boxes shall be lockable and set level with the finished grade. Boxes shall be Rainbird III , _I I_ I / 8' MIN. / <br /> and "double boxed". �- �- _ GROUNDING ROD W A Sti <br /> sP /ti <br /> • All heads shall be installed as per detail. —I 1 =11 I <br /> (1 OF 3) <br /> • Install double check valve assembly, pressure reducing valve and quick coupler in �vr ,°a�I�b�9Z o <br /> separate irrigation boxes as per EPRD detail. 2" CONDUIT SWEEPS WITH BELL END FOR POWER WIRE CONNECTION <br /> • The DCVA shall be supported by an approved <br /> material. TO ESP SITE SATON GROUND ROD LAYOUT GROUND ROD ASSEMBLY = �� Z <br /> 80 unions at both connections to the double check valve assembly and PHONE AND GROUND WIRE �`/,.. ' 4 <br /> • Use schedule -y �o / o`v� v <br /> master valve, as per detail. Use Sch 80 pipe and fittings for all exposed pipe in boxes <br /> and at the P.O.C. MASTER VALVE FIELD WIRES, ZONE VALVE FIELD WIRE, PE89 <br /> at finishedgrade (neither above nor below). 4. <br /> COMMUNICATION WIRE WITH 6 PAIRS OF SHIELDED AND TWISTED NOTES: MINIMUM 8' SPACING BETWEEN RODS. USE 10g (MINIMUM) BARE 0S x,5',3 41��\,�,�� <br /> Set• c top of heads ) WIRES TO FLOW METER, FIELD WIRE TO ANTENNA, PROTECT <br /> • Each drip zone shall have an air relief valve in each bed at the highest elevation in COPPER WIRE WITH GREATER THAN 50HM RESISTANCE. WIRE FROM C'I PE ARG <br /> that bed and a line flush valve at the lowest elevation in each bed. CONNCETIONS USING PREFORMED SERVICE AND RANGER SEALSEQUIPMENT TO FIRST ROD SHOULD BE SHORT AND STRAIGHT AS <br /> NOTES: FOR DETAILED INFORMATION CONTACT GEOFF LARSEN, POSSIBLE. USE SEPARATE CLAMP FOR EACH WIRE. <br /> • Each drip zone valve shall be accompanied by a filter and pry. As specified in plan. SUPERVISOR II HORTICULTURE/FORESTRY, EVERETT PARKS AND <br /> • Use standard swing arms each head, as per detail. COMMUNITY SERVICES, P: 245-257-7348, C: 425-210-6985 <br /> • Valve boxes shall be Rainbird valve box as per detail. PROJECT IDENTIFICATION: D <br /> • Double <br /> couplingces (em to binstalled to meet detrds fl. CONTROLLER IN WALL MOUNTED MAXICOM CABINET <br /> • Double check valve assembly must meet city standards for installation. GE-3) GROUNDING DETAIL <br /> N.T.S. EVERETT PARKS & RECREATION DEPARTMENT STANDARD DETAIL N.T.S. <br /> ELECTRICAL EVERETT PARKS & RECREATION DEPARTMENT STANDARD DETAIL Evergreen Branch <br /> • All wires shall be laid in mainline trenches under pipe. <br /> • Wire to be buried with mainlines (18") and in sleeves under asphalt or concrete. <br /> • Each valve shall have separate a control wire and a spare wire. Control Wire to be black Library Expansion <br /> in color and spare shall be orange. <br /> • All wire connections to be visible and boxed, min 10" round box w lid. RAINBIRD VALVEBOX 10" <br /> • Control wire shall be #14 g black, #14 g white - common, and #14 g orange - spare, ROUND DOUBLE BOXED FOR <br /> from controller to each valve, unless otherwise specified. VB-RND-H <br /> • Spare wires shall be located as shown. <br /> • Protect spare wires from damage. FINISH GRADE <br /> II City O Everett <br /> • Wire to electrically connect controller to all valves. <br /> • Provide lockable irrigation box at location shown with a minimum of 6' of coiled wire. <br /> • Wire from power supply to controller shall be in electrical conduit. PE89 - TO CONTROLLER <br /> • Any wall-mounted controller shall be securely connected as determined by Park staff. <br /> • All electric valve wiring shall be irrigation control wire type "u.f." direct burial. <br /> • System shall include spare wires (orange) and one common (white). LENGTH = 10 X PIPE LENGTH = 5 X PIPE DIAMETER 1 1 " RED WIRE AT <br /> • System shall include one #14 g yellow trace wire from controller to all valves and DIAMETER MINIMUM 15" <br /> continuously connected between all valves and controller. LENGTH EXAMPLE 1 3" SCH MINIMUM 10" LENGTH <br /> EXAMPLE 1 SCH 80 PIPE 9512 Evergreen Way <br /> • Place all electrical joints (splices) in boxes only. 80 PIPE NO FITTINGS ALLOWED 98204 <br /> • All wire splices to be connected with silicon, waterproof Scotch Lock connectors (3m NO FITTINGS ALLOWED Everett WA <br /> dby for 14 g. or 3m 316ir for 18 g.) connectors with wires taped together. -"4"1111111P\ <br /> TWO WRAPS OF VINYL TAPE <br /> • Leave minimum of 24" slack wire at any splice and connection. MASTER VALVE / <br /> • Control wires shall be different colors than ground wire. �' - / ' <br /> • Controller to be grounded per manufacturer's specifications. (� �' III./IIIIIIII <br /> • Use Rainbird FEB electric valves. Use Teflon tape and pipe sealant on all valve /' J 111 <br /> is <br /> threaded connections. BID SET <br /> =0 <br /> BLACK WIRE <br /> al�Iiii--, if SCH 40 PIPE MAIN LINE II <br /> • PE 89 with 4' slack wire in the box for all Maxicom field devise connections. > \ � <br /> TESTING/COMPLETION \ It <br /> • Adjust system for optimum pressure, efficient distribution, and adjust head type or 4 EA ZIP TIES Ti" HOLE ASSEMBLED CAP <br /> spacing for slopes as needed. COUPLING AND 7' FLOW METER This drawing is: <br /> • Adjust head locations and nozzles to provide full even coverage and avoid over spray of 1 RAINBIRD FS150P OR 2" RAINBIRD REDUCER 1. Copyright 2017 Dykeman, Inc. C <br /> hard surfaces. FS200P OR 3" RAINBIRD FS300P BRUSHING AS i 2.The Architect's Instrument of Professional Service. <br /> • Notify owner/ representative one day prior to testing for owner/ representative RANGER SERVISEAL PREFORMED # PN070421 FOR SINGLE 3. For use on this project only. Obtain Architect's <br /> attendance at testing. NEEDED DI����� CONNECT THE BLUE WIRE FROM BLUE/WHITE written permission for any other use or reproduction. <br /> PE89 APPLICATION SUPER SERVISEAL PREFORMED # 011111 1� TWISTED PAIR TO BLACK WIRE FROM FLOW METER <br /> • Pressure test system before approval/acceptance. PN0742V-1 FOR DOUBLE PE89 APPLICATION CONNECT RED PE89 CONTROL RED WIRE IIIII.I�I <br /> • Fill and compact all trenches after pressure testing is complete and approved by owner. WIRE TO WHITE WIRE OF PE89 BLUE/WHITE PAIR AND BLACK WIRE 3' LOOP IN �; - CONNECT THE WHITE WIRE FROM BLUE/WHITE PROJECT NUMBER: <br /> BLACK WIRE 1 = �� <br /> 3M 331R WIRE CONNECTOR ���;I TWISTED PAIR TO RED WIRE FROM FLOW METER <br /> BOX FILLED CLOSURE <br /> EVERETT PARK & RECREATION (EPRD) RESPONSIBILITIES WIRE TO BLUE WIRE OF PE89 BLUE/WHITE PAIR _��UoUoUovovoUovovoUo`Uo`� �o`�o�c��oo�o�OP�oUcoer �� .�� <br /> - O O O O p O O O O O O O O O O O O O O O <br /> • Owner b locate existing irrigation and owner utilities including electrical. j l '-' D( <br /> � ` �•� •�•� ' ` 2017-008 <br /> • Park arborist will mark the root protection zone, prior to any site work. o 0 0�0 4:? 0 00 0 0 0 0 0 0 0 0�0� oo.o. o� 4" FREE DRAINING SOIL '0 0 00 0��//��0�}0 0 0 0 0 0 0 0 0 o p o 0 0 0 0 o o p <br /> • Exact location of cabinet-mounted electrical conduit and controller to be determined ) LJ(� •�•�•�•�Ill •I•- C <br /> by Park staff. o o O O o 0 ODUUU p o 0 0 0 o p o p o.o.o��.o o =�p-�p•- NOTES: SCREW CLOSURE ONTO CAP ASSEMBLY REVISIONS: <br /> • Written approval fora material substitution request shall be provided by CityUNTIL RIDGE AROUND TOP CONTACTS CLOSURE <br /> representative before substitution may be used. 1-D- o 0 0 =� 0 0 ---401c4 0 0 0 --- 0 0 0 0 =�-��:� <br /> O O O O O O O O O O O O O O O O O p <br /> - � �� MARK DATE DESCR <br /> PRECONSTRUCTION ( >C)ci( )�( ( �( ' ( <br /> 08-07-17 DD Submittal <br /> • Contractor shall be responsible for all permits, permit fees and inspections, unless <br /> specifically identified in the project documentation. 08-17-17 DDSubmittal• Alterations and changes to layout may be expected to conform to the ground 10-06-17 Land Use Submittal - <br /> conditions and to provide full and adequate coverage of water. Changes must be 08-14-18 Permit Set <br /> noted and submitted to EPRD project manager and ensure head to head coverage and09-10-18 Bid Set <br /> a 60% DU for spray head zones, 70& DU for rotor/ rotary nozzle head zones and FLOW METER INSTALLATION RANGER SEAL WIRE CONNECTIONS TO FLOW METER 10-04-18 Addendum <br /> 85% for Dripperline zones. D <br /> • It is understood that corrective measures in the system may become necessary, but �6 EVERETT PARKS & RECREATION DEPARTMENT STANDARD DETAIL Scale: N.T.S. EVERETT PARKS & RECREATION DEPARTMENT STANDARD DETAIL N.T.S. <br /> that no changes or alterations shall be made without the prior authorization of the <br /> owner. <br /> • Material substitution requests will only be accepted when requested in writing and <br /> approved/denied by EPRD Irrigation Manager. <br /> • Written substitution request shall include all data sheets and an explanation of how <br /> the substituted item exceeds the requirements or performance of the specified item. <br /> • ERPD will give written notification to contractor of approval/rejection of request. <br /> • All work shall conform to City of Everett storm water management manual. BMP's THRUST BLOCKS <br /> (Best Management Practices) for tree and shrub protection are to be installed prior to <br /> any Work started and maintained at all times. 1. THRUST BLOCKS SHALL BE INSTALLED 3. CONCRETE THRUST BLOCKS FOR THESE <br /> • Site shall be protected from damage and limit exposure of open trenches to the WHERE THE IRRIGATION MAIN AND LATERAL LINES SHALL BE SIZED AND PLACED AND <br /> (2-1/2- AND LARGER) CHANGES SECURED IN STRICT ACCORDANCE WITH B <br /> public. DIRECTION, AS AT ELLS AND TEES AND THE PIPE MANUFACTURER'S <br /> DESIGN THE IRRIGATION MAIN TERMINATES. ADEQUATE AND SO SHALL <br /> PLACEDOF AN <br /> NAKE PROJECT TEAM: <br /> FINISH GRADE 44.�� OCA O 0 0 FINISH GRADE PRINCIPAL IN CHARGE: NH <br /> • Plans are diagrammatic. '�1� , ,10 , 2. PRESSURE TESTS SHALL NO BE MADE FOR ALL THRUST CREATED BY THE MAXIMUM I <br /> • Some boring under sidewalks is to be expected. �� ,� ` /,� ` I1 ' ' V ' / A PERIOD OF 36 TO 48 HOURS FOLLOWING INTERNAL WATER PRESSURE. PROJECT MANAGER: <br /> • Insure positive drainage of water out of and away from all components. ,�`;�'r,�/ �OI��r,�/ <br /> • Zones shall be as indicated. I f , 0 �+ �' � L . ,' THE COMPLETION OF POURING OF THE PROJECT ARCHITECT: <br /> /,/ / �\ /����/\' /\/\/\ I ° II /\�/\�; THRUST BLOCKS. 4. THRUST BLOCKS SHALL BE 1 CUBIC FT OF JOB CAPTAIN: I AL <br /> SITE PREP // // / \ \// // // // /\\/\�/ CONCRETE MIN. PIPE SHALL NOT BE <br /> • Soil Protection/ Tree and Shrub protection to be installed prior to site work. \' /\ \ \/ \/ \��\ ENCASED IN CONCRETE. <br /> Sitegradingisto be approved owner prior to the installation of the irrigation \\/%\\� �/ ��/ / ,// KEYPLAN. <br /> • <br /> system. pp by =1111-1111-1111=Illi=-111 =III- <br /> y11- -1111-1111 =IIL-TIII-ILII <br /> • Check with park arborist or ERPD designee to mark root protection zone. CONCRETE THRUST i =III <br /> =u1. <br /> h rootprotection zones will be done bylow I1- BLOCK, TYPICAL ''. (IIT= <br /> • Any excavation or disturbance within the ( a I-IIt11i1MI .''1111= <br /> impact methods to include air spade excavation or vactor truck removal and reviewed POP-UP SPRAY SPRINKLER: N SWING PIPE, 12" LENGTH: <br /> II- MAINLINE PIPE -T <br /> with park arborist or EPRD designee prior to any work. RAINBIRD 1800-RD-6-S-P45 RAINBIRD MODEL SP-100 11T- <br /> E--• Roots 1" diameter or larger within the root protection zone will be preserved by WITH RAINBIRD ROTARY NOZZLE - III <br /> digging under or around. Do not cut. 3" MALE NPT X .490" BARB ELBOW: ---=-- - III <br /> • No mechanical work will be done within the root protection zones. 3" MALE NPT X .490" BARB ELBOW: RAINBIRD MODEL SBE-050 EIII.-III=11- '�=1111=II II <br /> • Verifylocation and depth of utilities and services prior to excavating. RAINBIRD MODEL SBE-050 -V "�III_Ig1_ UNDISTURBED SOIL IE III I <br /> p7 PVC SCH 40 TEE OR ELL III <br /> • Notify owner of any discrepancies between existing conditions and proposed design 'l1= IE 111V- <br /> prior <br /> LATERAL PIPE 'ii= -° iI <br /> prior to construction. POP-UP SPRAY SPRINKLER: SWING PIPE, 12" LENGTH: 45 DEGREE ELL 90 DEGREE ELL <br /> EXCAVATION AND FILL RAINBIRD 1800-RD-12-S-P45 RAINBIRD MODEL SP-100 <br /> • Soils and compost shall be approved by owner prior to placement. WITH RAINBIRD ROTARY NOZZLE <br /> p MALE NPT X .490" BARB ELBOW: <br /> • Back fill shall be compacted in 6" lifts to 80% density, overfill trenches to provide for - 111=1111-1111-1111;1111-1111--1111-1111= CONCRETE ST <br /> - <br /> settling. 3" MALE NPT X .490" BARB ELBOW: RAINBIRD MODEL SBE-050 f BLOCK, TYPICAL <br /> RAINBIRD MODEL SBE-050 <br /> • No soil will be added within the root protection zones. 7 PVC SCH 40 TEE OR ELL <br /> • Removed and dispose of all 1 " rocks and larger within 3" of grade. PVC LATERAL PIPE O <br /> • Soil to be raked to leave a smooth surface for turf. MAINLINE PIPE <br /> DRAWING TITLE: <br /> • Bedding material shall be coarse washed sand. <br /> • The bedding material shall be placed at a minimum of 2" under and 4" over all pipe. <br /> _ <br /> ' _ - <br /> • Fill material shall be in 6" lifts of sand or excavated trench material free from rocks Tiff:-.--_--101:--.-_-II I'i=1111= <br /> greater than 1 " in diameter, debris or other sharp objects over 1/2" in diameter. <br /> • Remove excess soils and debris from site. 111, IIC �UNDISTURBED SOIL Irrigation Details & <br /> I IIP <br /> IILA <br /> City of Everett Parks & <br /> 90 DEGREE ELL Rec. Standard Notes <br /> E <br /> SHRUB ROTARY SPRINKLER 1800-RD-12-S-P45 TURF ROTARY SPRINKLER 1800-RD-6-S-P45 CG) THRUST BLOCKING DRAWING NUMBER: <br /> EVERETT PARKS & RECREATION DEPARTMENT STANDARD DETAIL Scale: N.T.S. (F) <br /> EVERETT PARKS & RECREATION DEPARTMENT STANDARD DETAIL Scale: N.T.S. NTS ....m. <br /> L3 . 2 <br /> NOTES: INSTALL ALL IRRIGATION COMPONENTS PER CITY OF <br /> EVERETT PARKS AND RECREATION STANDARD DETAILS <br /> I I 1 -- -- <br /> i <br />