My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9512 EVERGREEN WAY 2019 Plans 2022-11-03
>
Address Records
>
EVERGREEN WAY
>
9512
>
Plans
>
9512 EVERGREEN WAY 2019 Plans 2022-11-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2022 11:22:32 AM
Creation date
8/6/2020 11:29:19 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9512
Permit
K1904-001
Year
2019
Notes
NEW SPRINKLER SYSTEM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> BRANCHLINE RESTRAINTS <br /> BRANCH LINE RESTRAINTS ARE NOT REQUIRED WHERE BRANCHLINES ARE SUPPORTED BY RODS LESS THAN 6 LONG MEASURED BETWEEN <br /> TOP OF PIPE AND THE POINT OF ATTACHMENT TO BUILDING STRUCTURE. - <br /> Z <br /> H <br /> u: Q <br /> E I-- <br /> BOTTOM CHORD OF TJI O coo <br /> r-° <br /> NFPA 13 2016 TABLE 9.3.6.4(a) ✓—sAMMY SUPER SCREW GST 30 (1/4" x 3") w <br /> MAXIMUM SPACING OF BRANCHLINE RESTRAINTS <br /> (feet) WOOD FRAMING/ BLOCKING III III <br /> PIPE SEISMIC COEFFICIENT,Cp <br /> ON 0 p .- — TOLCO FIG. 75 <br /> ) Cp<0.5 0.5<Cp<0.71 Cp>0.71 <br /> Lu <br /> Lu <br /> SIDEWINDER SWG 20 (/4 x 2) :iii_ ALL THREAD ROD o <br /> U <br /> 1 36 - l FIG. 100 (3/8" ATR) `� <br /> 1 1/4 39 ALL THREAD ROD (TYP) _ �� <br /> 1 1/2 41 _ ADD RESTRAINT IF HANGER ROD EXCEEDS 6" o <br /> ° IN LENGTH TO BE MEASURED BETWEEN THE A:141', FIG. 200 O2 45 r> .� ��— H; TOP OF PIPE AND THE POINT OF ATTACHMENT �� ADJUSTABLE RING HANGER a <br /> INSTALLATION NOTE EXTEND ATR TO TOP OF Li. <br /> PIPE OR PROVIDE SURGE FIG. 200 0 ?> <br /> w <br /> 0. <br /> BRANCHLINE RESTRAINTS TO BE PROVIDED IN RETAINER CLIP TO ADJUSTABLE RING HANGER(2" MAX. PIPE DIA.) o �� <br /> INTERVALS BASED ON BRANCHLINE DIAMETER PREVENT UPWARD W <br /> AND VALUE OF Cp= 0.70 (Center column of table). <br /> MOVEMENT BRANCHLINE RESTRAINT TO WOOD BRANCHLINE RESTRAINT TO TJI'S o <br /> Z o <br /> Z <br /> O <br /> VVM N <br /> I C) N ch <br /> SWAY BRACE DETAILS & CALCULATIONS o. I ` , <br /> ti 4. <br /> IA <br /> **LATERAL SWAY BRACES ARE NOT REQUIRED WHERE MAINS ARE SUPPORTED BY RODS LESS THAN 6"LONG MEASURED BETWEEN TOP OF PIPE AND THE POINT OF ATTACHMENT TO BUILDING STRUCTURE** M (1 Q •• 0 I— <br /> ** <br /> ** SEE CALCULATIONS FOR MAX. SPACING, ANGLE OF ATTACHMENT, AND FASTENER INFORMATION ** — W Z M <br /> CO < r Cl)2 <br /> #2 5vW = <br /> r Q= ~wo a <br /> p I/2" THRU BOLT <br /> NUT 4 WASHER <br /> 44 p <br /> Ca I" SCHEDULE 40U) <br /> / PIPE (7' SPAN MAX.)2 x FRAMINGf/ ' <br /> 3/19/2019 U.S.Seismic Design Maps <br /> ��.., OSHPD r; <br /> yea :t Q <br /> CAI 4„- -,. 2 x FRAMING STRUCTURAL ATTACHMENT <br /> Z <br /> 9512 Evergreen Way, Everett, WA 98204, USA Q dm <br /> Latitude, Longitude: 47.9122932,-122.23827779999999 EL 0 <br /> N <br /> Canopy West F� //, W >", CO <br /> Truck Accessories �, 0) <br /> Mukilteo School Everett Public Library t�f'��✓e I" SCHEDULE 40 Z <br /> District Office Ever B <br /> g reen h <br /> V PIPE (7' SPAN MAX.) NNNNce O <br /> cy <br /> 9 ��?,�,/�4 a In SCHEDULE 40 Z 1 <br /> vPIPE (7' SPAN MAX.) <br /> LU 0 <br /> NAPA Auto Parts- <br /> FI 4L MEM <br /> ^ _FIG. 1001 Ca W Z <br /> Challenger �� The Parts Store South G '�. SWAY BRACE ATTACHMENT <br /> Elementary School v`a �, PIPE CLAMP -� 0 CAll J it <br /> yFOR SWAY BRACE _ <br /> „) ✓/orf€,,,„ •ti I <br /> Google wa Map data 0'0)19 Google LONGITUDINAL BRACE PIPE ATTACHMENT LATERAL BRACE PIPE ATTACHMENT Z W <br /> Date 3/19/2019,2:25:47 PM la <br /> Design Code Reference Document NEHRP-2009 g w <br /> Risk Category II 1"_ <br /> Site Class D-Stiff Soil COY•1 r W <br /> Type Value Description Z <br /> S 1A35 MC round motion. for 0.2seoond period) LATERAL BRACE CALCULATIONS LATERAL BRACE CALCULATIONS LONGITUDINAL BRACE CALCULATIONS W o) LU <br /> Ss ( P ) <br /> Si 0,553 MCER ground motion.(for 1.0s period) W <br /> Et <br /> SM3 1A35 Site-modified spectral acceleration value BRACE INFORMATION - LATERA L - 4" - BULK BRACE INFORMATION - LATERAL - 4" BRACE INFORMATION - LONGITUDINAL- 4" W <br /> CD <br /> SMS 0.83 Site-modified spectral acceleration value MAXIMUM SPACING 29'-0" MAXIMUM SPACING 15'-0" MAXIMUM SPACING 2q'-0" ^/ <br /> LENGTH OF BRACE 7'-0" LENGTH OF BRACE 7'-0" LENGTH OF BRACE 7'-0" CZ <br /> Sog 0.958 Numeric seismic design value at 0.2 second SA BRACING MATERIAL I" SCH. 40 BRACING MATERIAL I" SCH. 40 BRACING MATERIAL I" SCH. 40 W <br /> Sia 0.553 Numeric seismic design value at 1.0 second SA ANGLE FROM VERTICAL 60' MIN. ANGLE FROM VERTICAL G0' MIN. ANGLE FROM VERTICAL 60' MIN. - <br /> LEAST RAD. OF GYRATION 0.42" LEAST RAD. OF GYRATION 0.42" LEAST RAD. OF GYRATION 0.42" > <br /> L/R VALUE 200 L/R VALUE 200 L/R VALUE 200 <br /> MAX. HORIZONTAL LOAD 1604 LBS. MAX, HORIZONTAL LOAD 1604 LBS. MAX. HORIZONTAL LOAD 1604 LBS. W <br /> FORCE FACTOR (Fp) 0.70 FORCE FACTOR (Fp) 0.70 FORCE FACTOR (Fp) 0.61 <br /> FASTENER INFORMATION FASTENER INFORMATION FASTENER INFORMATION <br /> SEISMIC COEFFICIENT TABLE FASTEN ORIENTATION NFPA TYPE F FASTEN ORIENTATION NFPA TYPE F FASTEN ORIENTATION NFPA TYPE F <br /> TYPE THROUGH BOLT TYPE THROUGH BOLT TYPE THROUGH BOLT <br /> DIAMETER I/2" DIAMETER I/2" DIAMETER 1/2" <br /> PER NFPA 13 2016 9.3.5.6.2 LENGTH I%2" LENGTH 11/2" LENGTH I3'2" <br /> MAX. LOAD 395 LBS. MAX. LOAD 395 LBS. MAX. LOAD 395 LBS. REVISIONS <br /> TOLCO BRACE COMPONENTS TOLCO BRACE COMPONENTS TOLCO BRACE COMPONENTS <br /> Ss Cp <br /> FIG. 1001 CLAMP 1745 LBS. FIG. 1001 CLAMP 1386 LBS. FIG. 4L CLAMP 1745 LBS. <br /> FIG. 980 SWIVEL 1745 LBS. FIG. 980 SWIVEL 1745 LBS. FIG. 980 SWIVEL 1745 LBS. <br /> 1.435 0.70 LOAD INFORMATION LOAD INFORMATION LOAD INFORMATION <br /> SIZE 4 TYPE OF PIPE TOTAL LENGTH TOTAL CALCULATED LOAD SIZE * TYPE OF PIPE TOTAL LENGTH TOTAL CALCULATED LOAD SIZE * TYPE OF PIPE TOTAL LENGTH TOTAL CALCULATED LOAD <br /> 4" SCHEDULE 40 29' 333 LBS. 4" SCHEDULE 40 12' 138 LBS. 4" SCHEDULE 40 29' 333 LBS. <br /> 2" SCHEDULE 40 55' 197 LBS. <br /> % FOR FITTINGS 15% 50 LBS % FOR FITTINGS 15% 50 LBS <br /> TOTAL LOAD 383 LBS TOTAL LOAD 383 LBS <br /> SHEET TITLE <br /> % FOR FITTINGS 15% 50 LBS FIRE PROTECTION <br /> TOTAL LOAD 385 LBS <br /> PLANS <br /> r WASHINGTON STATE ' DATE:MARCH 6,2019 <br /> CERTIFICATE OF COMPETENCY FILE:25953 - <br /> FIRE PROTECTION SPRINKLER SYSTEMS <br /> Eric A Price 3/06/19 <br /> 3437-0508-C Level 3 Date <br /> Southeast Fire Protection <br /> SOUTHFP879NR Expires Fp4 <br /> Eri,c,Pri,u, 12/31/19 <br /> L Signature J OF 12 <br />