o �
<br /> vi W oNo '
<br /> _ 5/S-3.0 3/S-3.0 ,� � � �.
<br /> �
<br /> � � � �
<br /> �, ,
<br /> : 40�-0° •� � �; �
<br /> �r,
<br /> 2'-0' 28'-6 1/2° 11'-5 1/2" v � v �
<br /> a P �n
<br /> 3'-1" 9'-0" 6'-9 1/2" 6'-0" 3'-8" 9"�3'-0" 7'-8 1/2��
<br /> � N �n �
<br /> • N �
<br /> � N �
<br /> af
<br /> � 9050TS �
<br /> �
<br /> 6080 � 3080 �
<br /> � D
<br /> 5 1/8 x 9 24F GI.B 3 1/8 x 9 24F GLB 4x10 DF#2
<br /> M -
<br /> R311.3
<br /> MW LANDINU AT EXTERIOR
<br /> ��13�$R�. DOORS TO BE 36"IN DIRECTION
<br /> � o u�, OF TRAVEL AND WIDTFI OF DOOR
<br /> � .. . . . . . � � � . .. � � � � . .W .i . . N . � . � ; . � � � � . �. � . - . � . . . . � �� . . . . . � . � . � . . . �. . . . .
<br /> . . .. . . . �. � . . . . . . . . . . � . . � � N � . N . � . � � � �� . . . � .. . . � . . . � . �. ... [� .. . . �. . � . . . . � . . . � .. � . . � . . .
<br /> DINING o
<br /> o D
<br /> ,
<br /> . . . . . . . . , . . �. �N � . .. . � � � . . . � . . � . � . . . -N . . . � . . .. . � . . . . . , . �/�
<br /> . .� . . . .. . � . .. . � . � . . . � . � . � . . � . - . . . . '� . . . . .� . . . . . . . � � . .. . � . . . � VJ . . -
<br /> �a � .
<br /> a -' �i
<br /> V� ' � � �
<br /> Zv�U o a • � '�
<br /> � � _� q
<br /> �w ^
<br /> a
<br /> � ��� FAMILY N N x3oz.6 N �n , H
<br /> v�w o 1/2"GYPSUNI BOARD ON GARAGE W .
<br /> 2'-0" p�� a0 SIDE OF WARM WALLS,ATTIC AREA �
<br /> N w a O AND SUPPORTING WALLS. � �
<br /> , , ` � 5/8"TYPE X GWB UNDERANY
<br /> ;, , HABITABLE ROOMS r�I .�
<br /> . o D . r--i �
<br /> "' o`� M 1507.3 [� �
<br /> `�'•., 100 CPNi VTO �
<br /> Q
<br /> � � 2�_3�� � � .
<br /> ou+ �.,�
<br /> . . � . . . � � . . . . � . . . . . . W � . N . . . . . . . .. � . � . � . � . . . . . . . . . . " . . -.^ , . ��
<br /> � . . . . . . . � . � N.� .. .. O. �. � . . � � � . . . � . , . . � . . . . . . . . � . `L� � �.�„J - .
<br /> N ��g, NI1307.4 � �
<br /> � �, 2 PERMANENT OPENINGS �
<br /> EXTERIOK HEADERS TO � .�3�� N , SHALL BE CONSTRUCTED, � �
<br /> � D BE 4x10 DF#2 UN.O: � ONE WITHIN 12"OF CEILING a {� •�
<br /> n, � `^ AND ONE WITHIN 12"OF FLOOR � �
<br /> � _ � W
<br /> OPEN RAIL `'' 9'-6 1/2" 4'-3 1/2" ��A�. ��►��2" SG�N� V�1'�S �
<br /> : � �
<br /> � 5 1/8 x 10 1/2 24F GLB
<br /> ,
<br /> � UP '° � e wH � —
<br /> . , . . . � . � . � .. � . . co . . N� . � . . � � . . . � . .
<br /> . . . . . � � . . � ��� . . . . . . . , . . � .
<br /> . � . . . - . � � � �T 4� . . . . . . . . .
<br /> � . � . . � � . � n . � . . . . . . . � . .. . . .. . . . . � � .
<br /> R302.7 � M 1307.3.1 M 1307:2
<br /> � BOLLARD 2 STRAPS AT UPPER AND
<br /> 1/2"GWB IN � � M1507.3 LOWER THIRD,WITH 4°
<br /> ENCLOSED SPACE c`Av �;� _ 50 CFM VTO CLEARANCE OF CONTROLS
<br /> UNDER STAIRS M1307.3
<br /> _ IGNITION SOURCE TO BE �
<br /> _.�ut�$B: ' MIN 18"OFF FLOOR 2/5-2.0 '-'
<br /> �1�s-- �
<br /> 9�-$�� � WA� cn� O0 -� �i�i� /�AX 1+�-{.SE GAl\11GL' �—
<br /> R408.4 " 51-51-0315 `�' so N ��+� .
<br /> � �
<br /> IvIIN 18x24 CRA�VL R314
<br /> SP�E A�ESS. _° R302.51 0 �
<br /> � 1 3/8"SOLID WOOD DOOR, o �
<br /> c��i BLOCKED' / V SOLID OR HONEYCOMB `�
<br /> STEEL DOOR,OR 20 MIN.
<br /> v, DIAPHRAGM w �
<br /> � � � N FIRERATEDDOOR - -- - - - - - - - - - - - --�
<br /> � N •
<br /> o D / w m o �
<br /> - - ----- ----- ----- - ----- ----- ---
<br /> -
<br /> ---- --- ------ ---- ----- --- o —
<br /> � DEN � � �-- 5 i�s X 2�2ar GLs N w
<br /> � `Q `� � I 6 3/4 x 2O4 24F GLB I m 'BLOCKED'DIAPFIRAGM: Q �
<br /> n, o0 00 // 15/32"APA RATED CDX SHTG W/
<br /> ENTRY 'BLOCKED' / � 8d @ 6°O.C.(PANEL EDGE) Q �
<br /> 11'- ' N I BOUDARY EDGES o Sd @ 12"O.C.(PANEL FIELD) � Q�
<br /> ,n DIAPHRAGM � 8d @ 4"O.C.(BOUDARY EDGE � ~"J -
<br /> R308.4 ("PYPICAL) � ) 'L_{
<br /> ( � �
<br /> SAFETY GLASS / /.�
<br /> � �
<br /> 3 1/8 x 12 24F GLB
<br /> � 6050RS W/TRANSOIvI I I 660F 3080 — — — — — — — — - — — �' �
<br /> � � I v
<br /> � PORCH iboso � '-a
<br /> , �
<br /> _ �, i i '0 0 � [�
<br /> � � 4x8 DF#2 T'YPICAL ' d. + � �- L `'
<br /> �
<br /> � � � " `
<br /> � � AT PORCH ' �;� 3 `A ���,� `� � (f]
<br /> � � �
<br /> � -- ---- ---- I �"" ,� �' ' ��x' ,� �
<br /> �-- --- -- – _
<br /> � �
<br /> - ---- -- -------- �,,,.�,.-� ..�. .
<br /> --- - r„� �'.�}�`r,�:J��ar�'d��i���, �.
<br /> _ 4x4 POSTS WITH AC CAPS r y, ,� Qp ".,7r�a�,� � �
<br /> 4/5-4.0 _., �
<br /> AND AB ANCHORS J��y o�' � ; ��� '", �
<br /> LOWER FLOOR ) � �� � a �,� ,�
<br /> 1'-111/2' , �� - . ��
<br /> ° �
<br /> 2�-61i2° _s I . 1,-9° i6�-o° 2�-0° SCALE 1/4 — 1FT � -
<br /> 2'-9" 6'-0" ' 6^�-� 3'-0" 2'-0�� �� _ P4^ E. �,c� ,, � ��'
<br /> �_�
<br /> 11'-3 1/2" �' .�a�`�''S �,j a�
<br /> 9'-0' 19'-8 1/2" � ;� ��
<br /> � �"r�;;•
<br /> 40'-0" �,.�>.�� 3 ��;� ��S��� ����.�
<br /> .:�y ,. .�. .,.� �-��r,f
<br /> ''l��? ��3�t"} i��.+�'�^'�"'o
<br /> � �`���a�t�` 05-21-2013
<br /> �j��� �� ����3 REVISED
<br /> 06-13-2013
<br />
|