Laserfiche WebLink
Table Excerpted from Full MGS Flood Output <br />Structure Stage, Storage Discharge Tables <br />Predev 50-yr Peak 0.355 CFS <br />Corresponding Stage 107.82 FT <br />Link: Lnk2 DETENTION TANK <br />Elev Storage Discharge Infilt Discharge <br />(ft) (ac-ft) (cfs) (cfs) _ <br />OVERFLOW <br />WEIR SET AT <br />THIS STAGE <br />100.000 <br />0.000 <br />0.000 <br />0 <br />100.258 <br />0.002 <br />0.000 <br />0 <br />100.515 <br />0.003 <br />0.003 <br />0 <br />101.030 <br />0.011 <br />0.019 <br />0 <br />102.060 <br />0.027 <br />0.033 <br />0 <br />103.090 <br />0.048 <br />0.043 <br />0 <br />104.120 <br />0.069 <br />0.051 <br />0 <br />104.390 <br />0.075 <br />0.053 <br />0 <br />104.660 <br />0.080 <br />0.054 <br />0 <br />104.930 <br />0.086 <br />0.056 <br />0 <br />105.200 <br />0.091 <br />0.058 <br />0 <br />105.458 <br />0.097 <br />0.067 <br />0 <br />105.715 <br />0.102 <br />0.071 <br />0 <br />105.973 <br />0.106 <br />0.075 <br />0 <br />106.279 <br />0.112 <br />0.079 <br />0 <br />106.586 <br />0.116 <br />0.083 <br />0 <br />106.893 <br />0.122 <br />0.086 <br />0 <br />107.200 <br />0.126 <br />0.089 <br />0 <br />107.458 <br />0.129 <br />0.161 <br />0 <br />107.715 <br />0.131 <br />0.291 <br />0 <br />107.786 0.132 0.334 C <br />107.858 0.132 0.380 C <br />107.929 <br />0.132 <br />0.428 0 <br />108.000 <br />0.133 <br />0.478 0 <br />108.258 <br />0.133 <br />0.679 0 <br />108.515 <br />0.133 <br />0.813 0 <br />108.773 <br />0.133 <br />0.909 0 <br />