Permit it B1902-008
<br /> __ Site Address: 8517 7TH AVE SE
<br /> ` "- Owner: SAINT MARY MAGDALEN PARISH
<br /> Tenant: ST MARY MAGDALEN PARISH
<br /> App.Date: 2/19/2019
<br /> Proposed Use: COMMERCIAL
<br /> S 11A
<br /> -, REMODEL AND ADDITION., .,, OR:
<br /> :eevscienwpetidanB:y: REMODEL/ADDITIONTO� Dater EXTG CHURCH
<br /> : .,,. I
<br /> i ,,, \ *4* 1 i* A.,.,, Ai „
<br /> „I , ' , , ,
<br /> , , A i -. ., 1 f t i '
<br /> r i-�19
<br /> i I k ' 1 N i \
<br /> Office Set lob Site et Fire/Planning Set
<br /> t
<br /> ::.
<br /> Q 001
<br /> p N
<br /> LO
<br /> • . fir -
<br /> CnZ {_
<br /> Z o
<br /> ci_
<br /> p so I i 5 (7,
<br /> 49 En
<br /> It w I-
<br /> o
<br /> ar
<br /> W
<br /> a
<br /> DESIGN TEAM
<br />. ,
<br /> OWNER: PROJECT ARCHITECT: STRUCTURAL ENGINEER: ELECTRICAL ENGINEER: MECHANICAL ENGINEER: C
<br /> ST. MARY MAGDALEN PARISH BOTESCH, NASH & HALL ARCHITECTS, P.S. DCI ENGINEERS R. Martin Electric, Inc. Johansen Mechanical, Inc. _
<br /> 8517 7TH AVENUE SE 2727 Oakes Avenue 818 Stewart St., Suite 100 3615 132nd St. SW 20109 144th Ave. NE _
<br /> EVERETT, WA 98208 Suite 100 Seattle, WA 98101 Suite A Woodinville, WA 98072 M
<br /> Everett, WA 98201 (206) 332-1900 Lynnwood, WA 98037 (425) 481 -2266 - Z 5 N
<br /> (425) 259-0868 (425) 742-0852 Email: michaelm@johansenmech.com ed al
<br /> Email: bnh©bnharch.com Email: rick©rmartin.net s tri •N
<br /> co O_ a x
<br /> GENERAL NOTES ABBREVIATIONS SYMBOL LEGEND PROJECT DATA DRAWIN.G INDEX Z
<br /> �, w
<br /> w +�
<br /> N •
<br /> I. All construction shall comply with the 2012 International Building Code (IBC), A L GENERALO CO �, (pc) .
<br /> Washington State regulations For barrier-Free design, Washington State Energy A.B. ANCHOR BOLT L LONG; LENGTH DATUM POINT PROJECT NORTH MAJOR APPLICABLE CODESm 1E co
<br /> Code, and all applicable local codes, ordinances and standards. ABV ABOVE LAM LAMINATE INTERNATIONAL BUILDING CODE - 2015 G1.0 COVER SHEET f+ U )o
<br /> A/C AIR CONDITIONING LAV LAVATORY GLI LIFE SAFETY PLANS
<br /> 2. The Contractor is to verify all existing conditions, dimensions, details, etc. ACT ACOUSTICAL CEILING TILE 1b, a POUND WASHINGTON STATE BUILDING CODE THESE DOCUMENTS HAVE NOT BEEN CO Q cn o,
<br /> AD AREA DRAIN LF LINEAR FOOT DETAIL NUMBER CHAPTER 51-50 WAC APPROVED FOR THE ISSUANCE OF -L)
<br /> and notify the Architect of any and all discrepancies prior to proceeding with the ai N
<br /> ADJ ADJUSTABLE LL LIVE LOADSURVEY
<br /> work. AFF ABOVE FINISH FLOOR LOC LOCATION O UNIFORM PLUMBING CODE - 2015 PUBLIC WORKS,MECHANICAL, FIRE r.., a'
<br /> ALUM ALUMINUM LT LIGHT A-000 NORTH INTERNATIONAL MECHANICAL CODE - 2015 SUPPRESSION,ELECTRICAL OR �,
<br /> 3. Do riot scale drawings; dimensions govern. The Contractor shall notify the ALT ALTERNATE LP LOW POINT e CIVIL PLUMBING PERMITS.
<br /> Architect immediately of any and all discrepancies. The drawing scales are APPROX APPROXIMATE ZONE CLASSIFICATION o a)
<br /> • indicated to provide visual proportion and should be verified with similar drawings ARCH ARCHITECT M `.. SHEET NUMBER DOOR NUMBER Cl COVER SHEET o 0
<br /> P P 9 R-1 SINGLE FAMILY DETACHED
<br /> and listed dimensions. ASPH ASPHALT MAS MASONRY ( C2 SWPP r--- ci)i
<br /> AUTO AUTOMATIC MAT MATERIAL •• _ a�
<br /> ACG. AGGREGATE MAX MAXIMUM CONSTRUCTION TYPE (IBC CHAPTER 6): C3 GRADING.t DRAINAGE * N 1-
<br /> 4.
<br /> 4. All dimensions are to be center line of stud, or face of concrete wall, unless MECH MECHANICAL DETAIL NUMBER TYPE V-B SPRINKLERED C4 WATER PLAN CITY OF EVERET�..
<br /> noted otherwise. BD B BOARD MFD MANUFACTURED WINDOW NUMBER
<br /> • BLDG BUILDING MFR MANUFACTURER I 0 OCCUPANCY TYPE (IBC CHAPTER 3):
<br /> ARCHITECTURAL REVIEWED FOR PE MIT
<br /> 5. Where devices or items or parts thereof are referred to in singular, it is BLK BLOCK MH MANHOLEA
<br /> • • intended that such shall apply to as many such devices, items or parts gas are BLKG BLOCKING MIN MINIMUM "000 A-3
<br /> required to properly complete the work, BLW BELOW MISG MISCELLANEOUS BUILDING AREA ALLOWABLE IBC TABLE 503 : ADS1,0 DEMO SITE PLAN
<br /> qu P Pe WALL TYPE BM BEAM M.O. MASONRY OPENING SHEET NUMBER
<br /> 6, It shall be the responsibility of the Contractor to locate all existing utilities B,M, BENCH MARK MTL METAL FLOOR: q,500 SF ASLO SITE PLAN
<br /> BRG BEARING 00SPRINKLER INCREASE PER 506.3: 38,000 SF AD1.1 DEMO FLOOR PLAN • Additional Permits Are Required
<br /> whether shown hereon or not and to protect them from damage. The N SECTION NUMBER AD1.2 DEMO MEZZANINE FLOOR PLAN
<br /> BSMT BASEMENT For This Project To Include:
<br /> Contractor shall bear all expense of repair or replacement of utilities or other BTM BOTTOM N NORTH A1.1 FIRST FLOOR PLAN
<br /> dams ed byoperations in conjunction with the execution of his work. BTWN BETWEEN NA NOT APPLICABLE 0 BUILDING AREA ACTUAL:
<br /> property 9 PA1.2 MEZZANINE FLOOR PLAN
<br /> NIC NOT IN CONTRACT A-moo EXISTING BUILDING: 8,737 SF
<br /> 7, The Contractor will verifyand conform to all requirements of all utilityC NO NUMBER NEW BUILDING AREA: 13,823 SF A1.3 CLERESTORY PLAN Plumbing © Sprinkler
<br /> • CAB CABINET NOM NOMINAL A2.1 FIRST FLOOR REFLECTED CEILING PLAN
<br /> companies, ur1less noted otherwise in the plans and specifications. C,B, CATCH BASIN NTS NOT TO SCALE SHEET NUMBER ROOM NAME Mechanical E] Fire Alarm
<br /> CJ CONTROL JOINT �� BUILDING AREA ACTUAL: A2.2 MEZZANINE REFLECTED CEILING PLAN
<br /> 8. Existing elevations and locations to be joined shall be verified by the CL,Q- CENTER LINE 0 ROOM FLOOR 1: 12,428 SF A3.0 ROOF PLAN Electrical
<br /> Contractor before constructionlayout. IF theydiffer From those shown on the CLG CEILING OA OVERALL WALL SECTION LETTER A4.0 EXTERIOR ELEVATIONS Cl)
<br /> MEZZANINE: 1,385 SF
<br /> drawings, the Contractor shall notifythe Architect, so modifications can be made CLO CLOSET O,C, ON CENTER (S) 001 A4.1 EXTERIOR ELEVATIONS
<br /> gCLR CLEAR OD OUTSIDE DIAMETER o TOTAL: 13 823 SF
<br /> before proceeding with the work. CMU CONCRETE MASONRY UNIT OPNG OPENING \ A5.0 BUILDING SECTIONS
<br /> Co CLEAN OUT OPP OPPOSITE A-000 ROOM NUMBER A5.1 BUILDING SECTIONS CC
<br /> q, All debris shall be removed From the premises and all areas shall be left in COL COLUMN 0_F.C.I. OWNER FURNISHED- OCCUPANT LOADS (TABLE 1004,1,2): MONITORED AUTOMATIC FIRE
<br /> A5,2 WALL SECTIONS
<br /> coNc CONCRETE CONTRACTOR INSTALLED TOTAL OCC EACH EXIT A5.3 WALL SECTIONS DETECTION SYSTEM REQUIRED 0..
<br /> broom clean condition at all times, SHEET NUMBER
<br /> CONT CONTINUE (CONTINUOUS) 0.F.0.1. OFLOOR 1 8q0 2q7
<br /> OWNER FURNISHED-
<br /> CTR COUNTER OWNER INSTALLED A5.4 WALL SECTIONS
<br /> 10, The Contractor shall take alb necessary precautions to ensure the safety of CPT CARPET I MEZZANINE 45 45
<br /> the occupants and workers at all times. c.F,O.I. CONTRACTOR FURNISHED- P INTERIOR ELEVATION NUMBER A8,0 WALL TYPES SUPERVISED AUTOMATIC WZ
<br /> OWNER INSTALLED PER PERIMETER A8,1 ROOF DETAILS co
<br /> 11, Fire extinguishers: Verify the requirements and locations with the Fire PL
<br /> P.L. PLATE A8.3 WINDOW DETAILS SPRINKLER SYSTEM REQUIRED
<br /> marshal. The Contractor is to supply Fire extinguishers and cabinets, as required DBL D DOUBLE PROPERTY LINE 4 A-000 2
<br /> PLAM PLASTIC LAMINATE ABA DOOR DETAILS J
<br /> and/or as indicated on the drawings. DF DRINKING FOUNTAIN PLBG PLUMBING A8.5 INTERIOR DETAILS W sLyV�
<br /> DIA 0 DIAMETER W
<br /> DIM DIMENSION PLF POUNDS PER LINEAR FOOT
<br /> 3 SHEET NUMBER A8,6 STAIR DETAILS 1�
<br /> 12. Sound insulate all plumbing walls. PLYWD PLYWOOD 0)
<br /> DISP DISPENSER PNT PAINT (ED) Aq.O FINISH SCHEDULE
<br /> DN 13. The plans and specifications are minimums and where details are not DP DEEP PR PAIR Aq,1 DOOR 4 WINDOW SCHEDULES < W
<br /> specifically shown consistent practices shall be used. Codes and ordinances take DTL DETAIL PREFIN POUND SHED APPROVED
<br /> PSI POUNDS PER SQUARE FOOT 1-HR WALL PLANNING & COMMUNITY
<br /> precedence Over plans and specifications and wherever inconsistencies exist, it will DS DOWNSPOUT PSI FOUNDS PER SQUARE INCH STRUCTURAL
<br /> be the Contractor's responsibility to immediately notify the Owner and provide PIN PARTITIONWCCII= DEVELOP PT
<br /> acceptable corrections at no additional charge. E PVC POLYVINYL CHLORIDE 51.1 STRUCTURAL GENERAL NOTES ••
<br /> E EAST 2-HR WALL
<br /> EACH R 51.2 STRUCTURAL GENERAL NOTES BY - CC _ 1
<br /> 14, Use 5/8-inch GWB, Type X, in all locations unless noted otherwise. EA EXPANSION BOLT MIIM:C= 51.3 STRUCTURAL SPECIAL INSPECTIONS DATE - __ lm
<br /> EJ EXPANSION JOINT RA RETURN AIR14:
<br /> 15, The Contractor shall- provide mechanical, plumbingand electrical permits, EL ELEVATION RCP REFLECTED CEILING PLAN 2-HR SMOKE WALL S2,1 STRUCTURAL FOUNDATION PLANimm W
<br /> RID ROOF DRAIN 52,2 STRUCTURAL MEZZANINE PLAN CC
<br /> ELEC ELECTRIC (AL) RECPT RECEPTACLE
<br /> EQ EQUAL S2,3 STRUCTURAL ROOF PLAN W
<br /> 16, Sheet-metal' Plashingat skylights, roof hatches rooftop mechanical units REF REFERENCE/REFRIGERATOR Mal=
<br /> Y�g P EQUIP EQUIPMENT 4-HR WALL 53.1 STRUCTURAL FOUNDATION VENEER AND STEEL DETAILS
<br /> masonry head sills, soffits, parapet walls, reglets, expansion joints, etc,, shall EW EACH WAY REINF REINFORCE (MENT)
<br /> __ be installed as recommended by SMACNA (Sheet Metal and Air Conditioning EXIST EXISTING REQ'D REQUIRE (D) 54,1 STRUCTURAL WOOD FRAMING DETAILS ~
<br /> Contractors National Association) manual, EXT EXTERIOR REV C.REVI1SE(D);REVISION;REVERSE S5,1 STRUCTURAL WOOD FRAMING DETAILS V) W UJ
<br /> 17. Penetrations through rated construction sR,O, ROUGH OPENING
<br /> all be protected by U.L. Listed TF R,0.14, RIGHT OF WAY ELECTRICAL
<br /> stop materials and methods per IBC 2012. FD FLOOR DRAIN R.T.U. ROOF TOP UNIT KEYNOTE NUMBER •
<br /> FDN FOUNDATION RB RESILIENT BASE
<br /> FE • FIRE EXTINGUISHER E0.0 DEVICE LEGENDS AND EQUIPMENT SCHEDULE
<br /> 18, Sealing caulking and weather-stripping shall be installed to provide a FEC FIRE EXTINGUISHER CABINET S El LEGAL DESCRIPTION E1.1 MAIN LEVEL LIGHTING PLAN
<br /> complete building envelope FH FIRE HYDRANT 5 SOUTH REGISTERED
<br /> FIN FINISH SAN SANITARY E1.2 MEZZANINE LEVEL LIGHTING PLAN, FIXTURE SCHEDULE It DIMMING SCHEDULES N3776
<br /> ARCHITECT
<br /> lq. Prior approval is required on all changes or alterations to the approved plans. FIN FLR FINISH FLOOR SB SPLASH BLOCK DEMO KEYNOTE NUMBER E1.3 LIGHTING CONTROL DETAILS
<br /> FLR,FL FLOOR SC SOLID CORE E2.1 MAIN LEVEL POWER PLAN ' -
<br /> FLUOR FLUORESCENT SCH SCHEDULE PARCEL NUMBERS: E2.2 MEZZANINE POWER PLAN ANDREW M
<br /> FR FRAME(D)(ING)/FIRE RATED MATCH LINE
<br /> FT or (') FOOT SD STORM DRAIN 28051800200100, 28051800207600 28051600207800 E4,1 ONE LINE DIAGRAM AND SCHEDULES STATE OF WASHINGTON
<br /> FTG FOOTING SEAL SEALANT
<br /> FUR FURRED/FURRING SF SQUARE FOOT
<br /> SHT SHEET SEC 18 TWP 28 RGE 05RT-5A) BEG N1/4 COR TH N88*55 1BW 1173.47FT TH ALG
<br /> G SPEC SIMILAR
<br /> SPECIFICATION PICTURE NUMBER C/L RD S 413,O6FT TH E 20FT TPB TH E 561.67FT TH S q04.37 FT TO N MGN OF
<br /> GA GAGE, GAUGE SQ SQUARE RD TH N88*50 56W 55q.78FTTH ALG ELY MGN OF RD N 8g3.08FT TO TPBLESS JOB NUMBER •
<br /> GALV, GALVANIZED SERV SERVICE O
<br /> GB GRAB BAR FDT BEG N1/4 COR SAID SEC TH W ALG N LN SAID SEC 1173,47FT TO C/L CO RD
<br /> SS SANITARY SEWER 14-1050
<br /> SST STAINLESS STEEL REVISION CLOUD TN S ALG SAID C/L 413,O6FT TH E 2OFT TO TPOB TH E 150FT TH S 368FT TH E
<br /> V' C I N I TY MAP GC GENERAL CONTRACTOR
<br /> GL GLASS, GLAZING
<br /> GWB GYPSUM WALLBOARD-TYPE X STC SOUND TRANSMISSION CLASS
<br /> STANDARD 40FTTHDATE
<br /> 5 TAP 124FT N OF N LN CO RD THE 36q,78FT TH S 12OFT TO N LN CO s`�g` 1�
<br /> STD RD TH N88*50 56W 55q,78FT TO E LN CO RD TH N ALG SAID RD 8 3.08FT TO
<br /> H VISION NUMBER 1 at 16 H LRD_
<br /> E ERETT MARY MA DALE DRAWN BY
<br /> 5TL STEEL
<br /> STS STORM SENER
<br /> RE TPB EX ST OF WA 00377 70 q(SC 00 V G N) R^
<br /> rkSP + AveHC HOLLOW CORE STRUCT STRUCTURAL; STRUCTURE
<br /> I' z3 evilier J ::t HDR HEADER f(-REVISION
<br /> HDW HARDWARE
<br /> SUP SUPPLY
<br /> •o,i.',,,a(tciktie HO Scher SUSP SUSPEND (ED) CHECKED BY
<br /> g,� � � a HDWD HARDWOOD
<br /> Betels Ave ,%* HM HOLLOW METAL SIV STAIN t VARNISH AH
<br /> SITE
<br /> HORIZ HORIZONTAL SKS STORM HATER SENER
<br /> -<'-*,--,--,\,--� *��‘ HP HORSE POWER
<br /> TSUBMITTALS SHEET TITLE
<br /> D RRED
<br /> �S,�' r x B
<br /> Casino z t .Al'A, HTR HEATING WTR HEATER TELE TELEPHONE- 1 - ,
<br /> � �, ,,,, - , ,,,,, ,,,,,,.` �,�,`' HVAC HEATING, VENTILATING TEMP TEMPORARY A. /� SECTION LETTER
<br /> , '' AND AIR CONDITIONING TIG TONGUE I GROOVE /411:06, - - /
<br /> r.
<br /> �f 1 Ad 4 Az ER VISION
<br /> �" HW HOT WAT TV TELE
<br /> aten , z 3y \ T O B. TOP OF BEARING -AUTOMATIC SPRINKLER SYSTEM • COVER
<br /> I ,tt . ,.ASK I, ` k a ,,, ' w ,, T,O.S. TOP OF STRAPET
<br /> I T.O.S. TOP OF STEEL -FIRE ALARM SHEET
<br /> a'1 X30 = ID INSIDE DIAMETER T. TOP OF LL -MECHANICAL
<br /> ,'� TYPE TYPICAL r I?r.
<br /> I I ,,;U t e ;, INCL INCLUDE -ELECTRICAL r ` ; ;
<br /> t� � s I l � z�
<br /> ' 14,E°bili nl t :l IN or (e) INCH -_.,.,
<br /> +/ I its,r't°€,,rtrY s U V W & Y
<br /> -PLUMBING ' \.,-. '? , i -' I
<br /> •. � ���� � ;r�4�t �� �� s• INSUL INSULATION > > A i.�
<br /> � � � � , ti a � INT INTERIOR V VOLT ,;. � � Li
<br /> • ..� , ,47,p)„ V,C,T, VINYL COMPOSITION TILE1:‘‘..‘1
<br /> MAY C 9 2019
<br /> etas : - Qt; _ J VERT VERTICAL 0COLUMN GRID REFERENCE ��, SHEET NUMBER
<br /> 4� "41 4 � I � ���, JST. JOIST W WEST ...,
<br /> L
<br /> ' 1 W/
<br /> NTR
<br /> WITH R CITY C:1 I•" E V* rpt E i T
<br /> K N.C. WATER CLOSET PermitfServices w
<br /> <z, `luntirvto park t 4`4 ,:Arm ,4KW KILOWATT WD WOOD
<br /> kr��ffit �" s s � WH WATER HEATER
<br /> . c\ W/O WITHOUT
<br /> G1 . 0 1--
<br /> ,#,,1st,, °c , € WT WEIGHT M
<br /> . �x W.H.F. WELDED HIRE FABRIC •
<br /> s \4 W,K,M, WELDED WIRE MESH W
<br /> ` ,. YD YARD a.
<br />
|