Eve ET r WAC 296 ,B-900: ELECTRICAL PLP REVIEW <br /> WASHINGTON <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required. Then select the box next to (a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br /> required, select the box next to (b) and (c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> * If item (a)-(ii, iii, or v) is selected,the work must also comply with section (a)-(vii). See arrow flow chart below. <br /> (3) Electrical plan review. <br /> (a) Electrical plan review is not required for: <br /> ❑ (i) Low voltage systems; <br /> 4—❑ (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> ❑ (iv) Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the project's distribution system <br /> does not include: <br /> (A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2; or <br /> (C)A required fire pump system. <br /> ■ (v) Modifications to existing electrical installations where all of the following conditions are met: <br /> (A) Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D) Service or feeder load calculations are increased by 5% or less. <br /> (vi) Electric power production source(s) such as solar photovoltaic, fuel cell, or wind electric system(s)with a total <br /> ❑ rating of 9600 watts or less. <br /> (vii) For installations in (a)(ii), (iii), and (v) of this subsection to be considered, the following must be available <br /> ❑ to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed; and <br /> (D) Provide information showing that the service and feeder(s) supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical, dental, and chiropractic clinic"of which is a clinic or <br /> ❑ physicians' office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> ❑ <br /> (b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br /> occupancies defined in this chapter. <br /> 171 (c) If a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 900-1 Table 900-2 <br /> Health or Personal Care Facilities Educational and Institutional Facilities,Places of Assembly,or Other Facilities <br /> Health or Personal Care Facility Plan Review <br /> Type Required Educational.Institutional,or Plan Review <br /> �, ;ta; e, Other Facility Types Required <br /> `urs ng home unit or Icng-te-m es -ducat€ens Yes <br /> care u: it nstitutional Yas <br /> Boarc ng borne ves <br /> As _tedlinnefa_..cry -es <br /> ?ri,'ate alcohols-alcohol's-tohosoitn'. ','es Notes to Tables 900-1 and 900-2. <br /> Prb'ste psyc'o atric h c pial Yes city autnorizeo to do eiectricaai'i1-peciion= <br /> tat n;ty:.erne "es -i eqL e p°an.rev,e2Ar_ f cs'iyces,not <br /> rrbuator, urg e _.^.we, to; r-ie c p .s..'e'tt. <br /> Rena',hernodia;ysis c 'es <br /> RES ntoal te t-,eit fact iryErt^tes. <br /> a... ec TERICE <br /> Ty <br /> o,l:-esiaentiat rehabl,atie: ves <br /> PERMIT# C /03 A Y <br /> Page 2-Plan Review <br /> center <br />