Laserfiche WebLink
NETMETER CAUTION <br /> ...t. POWER TO THIS BUILDING IS SUPPLIED FROM THE <br /> NEC 705.12(B)(3) <br /> ,',,-,,Agitia FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN <br /> ,_........T. ......_ N <br /> PHOTOVOLTAIC A WARNING <br /> c:, �;rr rtenergyt... <br /> TURN OFF PHOTOVOLTAIC i ""'I <br /> AC DISCONNECT PRIOR TO i '---) E <br /> 1 IR::D r_......_.__........ <br /> AC DISCONNECT WORKING <br /> ..L.I w /74 <br /> •) E.IuI NEC 110 21(8)8 NlC 705.12 0 <br /> 1 iiiiil i mu;,.ItMag(Rw, 0"0,, a i <br /> ulul <br /> ulul <br /> .DYE,AD2BD <br /> OOPER MINT <br /> !I 11 ..n.o.. I Pw WA WOW <br /> I✓__ NEC 70512(8)(3) ._.... .nom L J PHONE 360.074343 <br /> # • '� JENNI�BAIANKENSHIP <br /> r SUPPLY SIDE TAP mums <br /> „,AR,,.x u� -1 AS REQUIRED IF PV PROJECT'kDETAILS <br /> I INTERCONNECTION IS AC DISCONNECT S 4.340 DC KW <br /> x MADE TO SUPPLY SIDE OF PRODUCTION METER 5.40040 AC RATING <br /> 05. 1)(2)P)(b ' SERVICE DISCONNECT NET METER CENTRAL INVERTER SYSTEM <br /> 2, 274” <br /> I <br /> PRODUCTION METER _ SERVICED BY QUALIFIED PERSONNEL ONLY CUSTOMER R.E0 •* <br /> UTILIPO AHJ(PHENOLIC) I NEC 690.59 581210TH DR W <br /> a`Ik R(Nxx€I! FSOE000LTASC DC DISCONNECT WA 982 T, <br /> > I RCUIT ® 98203 <br /> ...wawa s IN IVCUIT 0IPIMIT <br /> ( IiAL HMS VOLTAGE <br /> INTHER <br /> NEC 705.12(8)(3) IA 110 tTR JTr cIJaG.TMT II - O((42.5 ETH 4, <br /> 34499DR <br /> I NEC 690 56 ADHESIVE FASTENED SIGNS: <br /> •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENTWHERE RIS INSTALLED. AM:0083670000736O <br /> PHOTOVOLTAIC SYSTEM ••WHERE REQUIRED ELSEWHERE IN THIS CODE.ALL FIELD APPLIED LABELS.WARNINGS. <br /> 803AR PV SYSTEM EQUIPPED AND MARKINGS SHOULD COMPLY WITH ANS...54 CNEC'110 SI DFIELD MARKING). <br /> WITH RAPID SHUTODWX '" EQUIPPED WITH •ADHESIVE FASTENED SIGNS IMYBEACCEPTABLE F PROPERLY ADHERED VINYL SIGNS <br /> tt ® RAPID SHUTDOWN <br /> SHALL RESISTANT WEATHERRESTATE BAR 1 1 la) :::,x <br /> TURN EARL,SII DO x PON <br /> SPAM TOW <br /> .�:' NEC 690.310384 14 ALL EQUIPMENTTO BE LISTED RV UL OR OTHER NRR.AND LABELED FOR ITS TE DESCRIPTION <br /> APPLICATION. <br /> ANDWMDwiICE TEH �a� WARNING:PHOTOVOLTAIC 1J ALL CONDUCTORS SHALL BE COPPER.RATED FOR BOO V AND BO DEGREE C WET <br /> MOCK WM. 1 :III <br /> IN <br /> PHOTOVOLTAIC 6)C DISCONN POWER SOURCE 3J WINKING COENDUIT ANDRACEAS YS CLOS AS POSSIBLE <br /> ROOFTOPSSHALLROUTED <br /> REARM ()()() ENVIRONMENT <br /> NVIRO CON AND LOCATED AS CLOSE AS FOSS BLE TOTHE S NEAREST RIOGE:HIP. 10 <br /> NEC <br /> OR VALLEY OATE <br /> 1 WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEODPMENT ORAYH <br /> ECT * SHALL COMPLY WITH NEC 1,026 NGEMENT OF SYSTEMS CONTRACTOR DRAWN Y <br /> i>tIMUP Ai:OPER II II61111 ® ID P. <br /> SHALLLL FURNISH AL TNGS L NECESSAERY ME OWLETS.SUPPORTS.FITTINGS AND ACCESSORIES \\� $: <br /> N XV A NECORF69,VIII "® TO FULFILL APPLICABLE CODES AND STANDARDS. "4 }x.i�'.," <br /> NEC 690.54 6/ WHERE SCES OF JUNCTION BOXES.RACEWAYS.AND CONDUITS ARE NOT SPECIFIED. <br /> THE CONTRACTOR SHALL SZE THEM ACCORDINGLY <br /> TI ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. LABELING <br /> I 40 BJ SUPPORTODULEGROUNDING CLIPS TOBEINSTALLED BETWEEN MODULE FRAME MID REQUIREMENT <br /> IIIFFF���"' MODULE SPORT RA L PER THE GROUNDING CLIP MANUFACTURER'S <br /> ELECTRIC SHOCK HAZARD RAPID SHUTDOWN WARNING'PHOTOVOLTAIC INSTRUCTIONCO NOT . <br /> TERM0ALB OUx BOT)TERLINE AND NALSSWITCH FOR POWER SOURCE YJ L�GORELSCO GBLdDB'T LASUPPORT RAIL TO VEN LUG BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEK <br /> LOAD SIDES MAY BE ExEBCIaO SOLAR PV SYSTEM IOJ THE POLARmoFTHE GROUDED CONDUCTORS IS NEGATIVE SHEETNOMBER <br /> IN MORIN POSITIONNEC 690.56(0)(3) NEC 69081(0)(3)&(4) <br /> NEC 690.13(8)6 NEC 690.115(0) u.misit:.Hxmn v�,.I.P...PPUAw II A.I <br /> Wit n�m � <br />