• <br /> August 20,2018 <br /> Evan Manderbachsale <br /> A& R Solar <br /> 3211 MLK Jr Way S, Suite B <br /> Seattle,WA 98144 <br /> Subject: Structural Engineering Evaluation of Solar Panel installation <br /> Project: Everett Safe Streets Supportive Housing <br /> 6200 12th Drive SE <br /> Everett,WA 98203 <br /> Dear Evan: <br /> I have completed my evaluation of the solar installation for the referenced project in Everett,WA, <br /> and have the following findings and recommendations, <br /> The structure on which the panels will be installed is a new building currently under construction. <br /> The building is a multistory wood framed building with gang nailed roof trusses and l6 inch plywood roof <br /> sheathing. The roofing is AEP 22 Span Seam standing seam metal roofing. The majority of the roof <br /> will be covered with solar panels. The panels will be attached to XRIO rails that are anchored to the <br /> standing seam roofing with S-5!1;clamps spaced 48"on center. <br /> The building has been designed for an additional 5 psf included in the vertical and lateral calcula- <br /> tions so the vertical and lateral framing systems are adequate for the solar panels loads. I calculated the <br /> maximum vertical load that the XRIO rails will need to carry and found that the rails are within accepta <br /> ble stress limits with these loads. I also calculated wind uplift forces for the anchors and found that <br /> the anchors are adequate for the wind uplift forces in all areas of the roof. I also checked to see that the <br /> attachment of the roofing panels to the plywood deck we adequate to resist the uplift loads due to the <br /> wind forces on the panels. I found that the attachment of the roof panels to the plywood sheathing was <br /> adequate to resist the wind uplift forces from the solar panels. <br /> I also conducted a review of the overall wind and seismic loading for the building itself and found <br /> that the wind load for the structure will not be increased by the addition or the solar panels and that the <br /> increase in the seismic loading was accounted for in the original design ()law building . <br /> Based upon my understanding of the system and the calculations I have performed. it is my opin- <br /> ion that the solar system installed as outlined above and as shown in your submittal to me is in general <br /> conformance to the 2015 IBC and will adequately resist vertical loading due to dead loads and snow loads <br /> and lateral loading due to wind and seismic forces. <br /> Please let me know it'you have any questions or need anything further. 1 appreciate this opportun <br /> ity to provide you with these engineering services. <br /> , 2 <br /> ar 0 ,i(s <br /> Sincerely, <br /> wit. <br /> Clary E. Gill, SE s'E * • <br /> . / <br /> .gr <br /> 9 <br /> Clary E. Gill, SE1125 NE I52"'l Street <br /> I EYPIRE3710-'n—Fi <br /> (206)992-2728 Shoreline, WA 98155 <br />