r <br /> R-102 Restaurant Fire Suppression Manual SECTION 4—SYSTEM DESIGN <br /> UL EX3470 ULC EX3470 <br /> 2014-S EP-01 REV. 11 PAGE 4-73 <br /> DETECTION SYSTEM-REQUIREMENTS(Continued) TEE CLOSE TO AUTOMAN(EXAMPLE) <br /> 0-Electric Thermal Detector PULLEY TEE <br /> When electric thermal detection is used, the detection circuit 12 IN <br /> must be supervised in accordance with NFPA 17A,Standard for (304 mm) <br /> . Wet Chemical Extinguishing Systems.Electric thermal detectors <br /> must be used in conjunction with either the AUTOPULSE 542R <br /> • Control Panel (Part No. 433607) or the AUTOPULSE Z-10 <br /> Control Panel (Part No. 430525), and the 24VDC RegulatedGAS VALVE OR AUTOMAN GAS VALVE OR <br /> Release Assembly. MANUAL PULL MANUAL PULL <br /> 149 FTm) <br /> Note: Consider the rate of temperature increase in the location EACH <br /> (CACHH4 D AND 20 PULLEY ELBOWS MAXIMUM <br /> p PERSIDE OF TEE <br /> chosen for the detector when using electric thermal detection. TEE CLOSE TO GAS VALVES OR MANUAL PULL(EXAMPLE) <br /> A transient rush of warm air up to 40 °F (4°C) per minute may <br /> expand the shell, but not enough to trigger the AUTOPULSE 12 IN 12 IN <br /> control panel. Temperature increases over 40 °F (4 °C) per (304 mm) (304 mm) <br /> minute however, may initiate an alarm condition in the control <br /> PULLEY TEE <br /> panel. GAS VALVE OR GAS VALVE OR <br /> After determining the maximum ambient temperature at the MANUAL PULL MANUAL PULL <br /> thermal detector location, select the correct thermal detector AUTOMAN <br /> 149 FT(45.4 m)AND 20 PULLEY ELBOWS BETWEEN <br /> according to the temperature condition chart in the "System AUTOMAN AND TEE <br /> 0-Components"section. <br /> TEE HALFWAY BETWEEN AUTOMAN AND GAS VALVES OR MANUAL PULL(EXAMPLE) <br /> MANUAL PULL STATION REQUIREMENTS 75 FT(22.8 m)AND 10 PULLEY ELBOWS <br /> A remote manual pull station allows the R-102 system to be <br /> manually operated at some point distant from the regulated 75 FT(22.8 m)AND 75 FT(22.8 m)AND <br /> release assembly.The pull station should be installed at a height 10 PULLEY ELBOWS 10 PULLEY ELBOWS <br /> of 42-48 in. (1067-1219 mm), in accordance with the require- 6 PULLEY TEE 6 <br /> ments of the American Disabilities Act (ADA) and the Authority <br /> having Jurisdiction. and located in the path of egress. The pull AUTOMAN GAS VALVE OR GAS VALVE OR <br /> PULL <br /> station is the only source of manual actuation of the regulated MANUAL PULL MANUAL FIGURE 4-144 <br /> release assembly. 004907 <br /> The total length of the cable used for each manual pull station /Manual Pull Station Part No.435960 or 434618 <br /> within a system must not exceed 150 ft(45.7 m). <br /> Parts that may be used for installation of a metal stamped <br /> The maximum number of pulley elbows that may be used per remote manual pull station are: <br /> pull station is 20. <br /> Description Part No. <br /> One pulley tee is allowed per cable system. 0-Remote Manual Pull Station Assembly* 435960 <br /> The maximum length of cable from the AUTOMAN to a pull ®Remote Manual Pull Station Assembly 434618 <br /> station is 150 ft (45.7 m) with a maximum of 20 pulley elbows Pulley Elbow 423250 <br /> used per side of the tee.As the tee is located farther from the Pulley Elbow 415670 <br /> AUTOMAN,the 150 ft(45.7 m) maximum must be observed but Pulley Tee 427929 <br /> as pulley elbows are placed between the AUTOMAN and the *Assembly includes parts listed below: <br /> tee,they must be deducted from the available pulley elbows(20) 1/16 in.Stainless Steel Cable 50 ft(15.2 m) 15821 <br /> allowed on each side. Oval Press-To-Crimp Sleeves 4596 <br /> Example:If 10 pulley elbows are placed between the AUTOMAN Glass Break Rod(1) 4834 <br /> and the pulley tee,the maximum available pulley elbows left for <br /> ' use on each side of the tee is 10 per side. See Figure 4-144 <br /> for three different examples. (Note:Both must be gas valves or <br /> both must be pull stations. Mixing is not allowed.) <br />
The URL can be used to link to this page
Your browser does not support the video tag.