741 Marine Drive,Bellingham, WA 98225 www.geotest-inc.com
<br /> 1 � � 20611 67th Ave. NE. Unit A.Arlington, WA 98223
<br /> phone (360)733 7318 toll free:(888)251.5276 fax:(360) 733.7418
<br /> Concrete Inspection & Compressive Strength Test Report
<br /> PROJECT: Cargo Transit Shed Relocation JOB#: 18-0297
<br /> CLIENT: Port of Everett REPORT#: CB004
<br /> CONTRACTOR: McClure&Sons PAGE#: 2 of 3
<br /> GeoTest was onsite to perform sampling/testing of the concrete placed and inspect the
<br /> reinforcing steel for the above-referenced item. The concrete was placed via the truck chute,
<br /> internally vibrated, and was hand finished (light broom). All reinforcing conformed to the
<br /> approved plans (S1.2, S2.1, S5.1) and specifications, except for the following item:
<br /> • Vertical reinforcing for the future concrete stem walls (and shear wall end column base) at
<br /> Gridlines B/2 and D/2 were not in place. The contractor will discuss possible solutions with the
<br /> Port of Everett and KPFF.