Laserfiche WebLink
741 Marine Drive,Bellingham, WA 98225 www.geotest-inc.com <br /> t <br /> C,cOTeu5T 20611 67th Ave. NE. Unit A.Arlington, WA 98223 <br /> '°`R phone:(360)733.7318 toll free:(888)251.5276 fax:(360)733.7418 <br /> FIELD DENSITY/MOISTURE REPORT <br /> Nuclear Gauge * ASTM D6938 <br /> PROJECT: Cargo Transit Shed Relocation JOB#: 18-0297 <br /> ADDRESS: Everett,WA REPORT#: FD004 <br /> PERMIT#: B1803-043 DATE: 7/27/2018 <br /> CLIENT: Port of Everett PAGE#: 1 of 1 <br /> CONTRACTOR: McClure&Sons INSPECTOR: Anna Sigel <br /> Compaction Of: Water Line Trench Backfill-North and Southwest End of Building <br /> Field Data: <br /> Depth! 'DT/ - Wet Field Dry Compaction <br /> Test Location Elev BS Density Moisture Density Lab % Pass! <br /> (ft) (in) (pcf) (%) (pcf) # Attained Required ';fail <br /> 1 39'E of SW corner,center of trench -1.5'FE DT/6" 145.2 7.6 135.0 1 96 95 P <br /> Lab Max.Dry Optimum Retained <br /> Sample Soil Type Source Density Moisture On#4 Test <br /> (pcf) (%) (%) Method <br /> 1-3707A CSBC Cadman-Granite Falls 140.4 3.7 69 ASTM D1557/D4718 <br /> 2- 0.0 None <br /> 3- 0.0 None <br /> [Gauge Make/Model/Serial#: Instrotek/35000/3053 f M/D Standard Count: 428/3177 <br /> Comments: <br /> CSBC - Crushed Surfacing Base Course <br /> EE - Existing Elevation <br /> GeoTest was on site as requested to perform density testing at the above location. Soils were <br /> compacted via hoe pack. All tests met compaction requirements as per specification. <br /> COPIES. GeoTest Services Inc Port of Everett " Reviewed by <br /> This report shall not be reproduced except in full,without the written approval of GeoTest Services,Inc. <br /> The above test results relate only to the sample(or location)tested. <br />