Laserfiche WebLink
, <br /> Dev Event Summary <br /> Event ',Peak Q (cfs)'Peak T (hrs) Hyd Vol (acft) Area (ac) Method Raintype <br /> -1" <br /> 2 year . 0.1427 8.00 0.0554 0.7000 SBUH TYPE1A <br /> ..., <br /> 10 year 1 0.2401 8.00 0.0910 0.7000 SBUH ,TYPE1A <br /> 1 <br /> 100 year I 0.3878 i 8.00 0.1447 0.7000 1 SBUH !TYPE1A <br /> Record Id: Dev <br /> Design Method SBUH Rainfall type TYPE1A <br /> Hyd Intv 10.00 min Peaking Factor 484.00 <br /> Abstraction Coeff 0.20 <br /> Pervious Area (AMC 2) 0.33 ac DCIA 0.37 ac <br /> Pervious CN 86.00 1DC CN 98.00 <br /> Pervious TC 13.50 min DC TC I 10.00 min <br /> Pervious CN Cale <br /> 1 , <br /> , <br /> Description , SubArea . Sub cn <br /> Landscaping i 0.33 ac 86.00 <br /> I Pervious Composited CN(AMC 2) 86.00 <br /> Pervious TC Cale <br /> Type - Description Length 1 Slope Coeff Misc ; - - TT <br /> Sheet Short prairie grass and lawns.•. 0.15 150.00 ft 5.00% 10.150011.55 in 13.50 min <br /> Pervious TC i <br /> 113.50 min <br /> Directly Connected CN Cale <br /> I <br /> I Description SubArea I Sub cn <br /> Roof and D/W 0.37 ac 1 98.00 <br /> , <br /> DC Composited CN (AMC 2) , 98.00 <br /> Directly Connected TC Cale <br /> Type Description Length Slope Coeff I Misc ' TT <br /> Fixed iMin. Value !10.00 min <br /> Directly Connected TC , 10.00min <br />