Laserfiche WebLink
am a sa"aua� Ergx+aw�von <br />+�a��nre.w.;an. y,�ai, ww�aas <br />�'g o�mtus�rra.xrsa . <br />(1) Simpson or =. Locate at end of( SW) u,n.o. Install per <br />manufacturer recommendations for foundation minimum end <br />distance and embedment, deepen foundation as required. <br />(2) Construct cripple wall same as shearwall ($W) above, and <br />gable -end same as shearwall (SW) below, <br />(3) Requires 3x or (2) 2x foundation sill plate <br />(4) Threaded rod and coupler as required. <br />(5) Common nails, UNO: 8d=0.131"x2W, 10d=0.148"x3", <br />12d=0.148"x3'/", 16d=0.162"x3Y2", 16d sinker-0.148"x3Y". <br />(6) Install H1's on all trussesfrafters, A35's at 24"o1c on gables F <br />rim joist (or solid blkg) to top plate (sill plate at fdn) u.n.o.; When <br />specified spacing is less than 24"o/c, install A35's at roof solid <br />blk'ing to SW top plate, and install H1 or H2.5 on all <br />trusses/rafters- LTP4, LTP5 or LS50 can be substituted for A35, <br />Conn. per Simpson Strong -Tie or equal. <br />Minimum 3x or dbl-2x stud lam'd wl (2)-16d @ 6" o1c at <br />Bing panel edges. <br />Anchor bolts shall be embedded at least 7" into concrete; <br />e shall be a minimum of two bolts per piece with one bolt <br />ited not more than 12" or less than seven bolt diameters from <br />h end of the piece. 2x min PT, u.n.o. <br />Date: <br />HOLDOWN SCHEDULE <br />,lob #: 16-198 <br />MARK <br />HOLDOWN / FASTENERS TO <br />STRAP' 1 (2)-STUDS MIN U.N.O. <br />FOUNDATION <br />ANCHOR *(1)(4) <br />COMMENTS <br />T-1 <br />(11) - 16d to each <br />MST37 connected element <br />N/A <br />wall-to-wall connection u.n.o. <br />T-2 <br />HDQ8-SDS3 (20) - SDSYx3 <br />SST828 <br />718" fE TO F ROD <br />FLR TFAR <br />T-3 <br />STHD14/14RJ (30) - 16d sinkers <br />NtA <br />SHEARLL SCHEDULE p �# Date: 1/011900 <br />le Job #: 16-198 <br />MARK <br />*(2) <br />SHEATHING - APPLY TO <br />2x <br />2x HF STUDS @ 16"olc <br />U.N.Q. BELOW *(9) <br />SHEATHING EDGE NAILS *(5) <br />ALL EDGES BLOCKED <br />(do not penetrate past flush) <br />BASE PLATE <br />(5} <br />ROOF TO TOP PLATE, <br />FLOOR TO TOP PLATE <br />& SILL PLATE -(6) <br />SILL PLATE ANCHORS w/ <br />3' x 3" x 114" WASHERS 18} <br />SW-1 <br />7116" OSB <br />8d @ 6" o1c (12" o/c field) <br />16d @ 6 " o1c <br />A35 @ 16 " o/c <br />5/8"Oxl0" AB's @ 48 " o/c <br />SW-2 <br />7116" OSB 17) <br />8d @ 3" o/c (12" o/c field) <br />led @ 4-o/c <br />A35 @ 8 " o1c <br />518"0x10" AWs @ 12 " o/c <br />