__ ___ _ _
<br /> _ � T.�_ _ �_.____— ---- . _ _
<br /> �- _
<br /> KEY NOTES CLI ENT NOTES PLAN NOTES
<br /> ,855
<br /> A UNDER RCW 39.04.260, THIS PROJECT�IUST CO►iPLY WI1H ALL iHE REIXIIRE�IIENTS FOR PREVAlL1NG REGISTERED
<br /> 1� RELOCATE SIX ElQS11NG Mf(1RI(STATIONS. WAGE. THE WASHINGTON STATE [�PARTIIENT OF LABOR AND INDUSTRIES DETERMINES PREVAll1NG A. DO NOT SCALE DWGS, WRITTEN DIYENSIONS GOVERN. ALL PARIITION LOCATIONS SHALL BE AS �Hi���
<br /> WAGE RATES AND WFIICH PRO,ECTS I�AY � EXEIIPT fROwi THIS LAW. FOR MORE INFORIrIATION, SHOWN ON PARTITION PLAN, IN CASE OF CONFLICT NOi1FY ARCHITECT. PARTITION PLAN BY
<br /> ❑2 RELOCATED CSO TRNNING ROOIJI REQUIRES �IINI�IUI� 14 DATA OUTtETS. CONTACT THE DEPART�IENT OF LABOR ANO INDUSTRIES. ARCHITECT TAKES PRECE�ICE OVER ALL OTHER PLANS. ,cd���
<br /> � m �
<br /> � � � . Pedro A.de Magalhaes Castro
<br /> � � a3 RELOCATED OR NEW CARD READER LOCATION WITH ELECTRIC SiRIKE. B. AI1 WORK PERFORMED ON THIS PRO,�CT SHALL MEET OR IXCEED 1HE PRO,�CT SPEpFlCATiONS, B• ALL GYPSU�I BOARD PARTITIONS SHALL� TAPED, SPACKLED AND SANDED SMOOTH WITH NO STATE OF WASHWGTON .
<br /> "LEASED SPACE REQUIREMENTS' DA1m JULY 2005, FOUND ON WEBSITE VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO I�ATCH ADJACENT OR ADJOINING SURFACES
<br /> 4 PROVIDE ELECTRICAL AND CABLING ABOVE CEIIJNG TiLES FOR RELOCATED CEIUNG MOUNiED P�� 9 �• � � �p � � � � p WHERE REQUIRED. ALL SURFACES SHALL � ALIGNED.
<br /> ��k � PROJECTOR. htt : des.wa. ov sites default files ublic documents acilities S SR2005. df AS
<br /> PUBLISHED BY THE STATE OF WA�iINGTON, DEPARTI�IENT OF ENTERPRISE SERVICES (DES), DIVISION C. ALL PARTITIONS ARE DII�ENSIONED FR0�1 FINISH FA� OF 6W6 TO FlNISH FACE OF GYYB UNLESS
<br /> • ■ � PROVIDE ELECTRICAL AND DATA ABOVE CEILING T1LES FOR FUTURE ROUiER(S). OF REAL ESTATE SERVICES (RES), INCLUDING ALL ALLOWANCES AND DIRECTIVES DESCRIBED IN PART OTHERWISE NOTED. ALL DIMENSIONS I�ARKED '(XENR" OR 'qR' SHALL BE t�AINTNNm AND SHALL
<br /> � � �� '�� �- ��a ALLOW FOR THICKNESSES OF ALL WAII FlNISHES. U.O.N.
<br /> � P�";Ci; AND i���.'�ft t�t R�r`"'�� ^�E1��PdG �tA i�IALS AND FlNISHES AS REWIRED TO �IATCH c�'��.� �U�'^o o r t�o�
<br /> " C. LESSOR SHALL PROVIDE A LICE�ISED ELEC1RIqAN TO DISCONNECT AND CONNECT Al1 HARD VMRED ; � a ; ��, a��--� �,
<br /> ADJACENT FlNISH SiJRFACES TO AqiIEVE A UNIFORWI, IJKE NEW APPEARANCE THROUGHWT. ppyyQ� NON—LOW VOLT CONNECTIONS INCLUDIN6 ALL CONNECTIONS TO AND YMTHIN OFFlCE D. D►�IENSIONS �IARKED f I�EAN A TOLERANCE NOT GREATER NOR S�IALLER THAN 2 INCHES FR0�1
<br /> � � INDICATED DI�IENSION U.O.N. VERIFY FlQD DI�IENSIONS D(CEEDING TOLERANCE WITH THE � �° ° ° � °`� °`� � '� ` �°' °'
<br /> � SYSTEtiIS FURNIIURE PANELS. REPOSI110N PLACE AS SHOWN AND WIRE TO ACCO�II�ODATE THE � � �= � �T° N�'N� °��°
<br /> ❑7 ALL NON—�IATCHING FlNISHES TO � SELECTED FR0�1 LSR CO�IPIJANT�IATERIALS FROIt IENANL �STED A�IOUNT OF STATIONS TO BE SERVED. PATqi HOLES IN CEIUNG WHERE POLES ARE �ITECT. SECURE ARCHITECT'S APPROVAL 6 0 � � � o L o 0 0 � � �, a��
<br /> p O �O O N �� �T�.�� � N � � N..� N
<br /> a8 PROVIDE NEW FLOOR FINISHES AS NECESSARY WIiERE THE REMOVAL OF IXISTING WALLS OCCURS REbIIOVED. THE FJFCTRIGAN SHALL BE AVAILABIF TO DISCOMNECT AND CONNECT CONNECTION$ E. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANqES OR CONFLICTS IN THE LOCATlON(S) QF NEW `� °�� � � �'"" 'Y ��' a� � �
<br /> E
<br /> � TO PROVIDE A SEAI�ILESS TRANSITION BETWEEN SPACES/AREAS. DURING THE 'PHASm' MOVING PR(�CESS AS OESI(�IIAIED 8Y 1HE LESSEE. CONSTRUC110N. UPON COMPLETIOW OF PART1T10�! LAYOUT, NOTIFY ARCHITECT. VERIFlCATION OF THE a " `'' � `� � a 3�� ° �' c
<br /> � - a� � � a „ a �'a� o
<br /> `�" LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTiTI(k� INSTALLATION. o � o ° s ���6 �� 3 o N�a�
<br /> r �,"" Q MODIFY HVAC DISTRIBUTION, ZONING AND CONTROLS TO NEET NEW CONFlGURATION AND LSR'S. � °-� � a°- �� °° � � °
<br /> o � � � � �oo_� � a�.N � o �
<br /> F. R E F E R T O S N E E T A 0.1 F O R A D D I T I O N A L N O T E S, L E G E N D S, S Y 1 1 B O L S, A B B R E U t A i I O N S, A N D � �,�o� ��� � 3-�� N� o a.,
<br /> O O ■ � L � O C O O._ U
<br /> � 10 FURNITURE, EQUIP�IENT, � VOICE, DATA, SECURITY dc A(xESS SYSTE�I (�1�ICES ARE N.I.C. AND ���S. ~ �` � � " ° 3 '�"� �
<br /> m � o ��> '^ � E ° xa�j'3� � °vo
<br /> SHOWN FOR REFERENCE ONLY. COORDINATE CONSIRUCTION ACTIV1TlES WITH iENANT'S � a � ,,�Z y �, �,� o
<br /> `� � C O N T R A C T O R S A N D PR OW D E ACCE S S ES RE Q UIRED FOR INSTALLATION (ROUqi-IN dc TRI�I OUT) AS G. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JA1t6, U.O.N. o � N �� � �� �,, o o� �
<br /> � o .. o o �a o o�' � v,o
<br /> `� NECESSARY. , . � �,�,�.� � N� �,= � � °
<br /> H. A(1GN MEANS TO ACCURATELY LOCATE FlNISHm FACES IN THE SAtitE PLANE � .- � � o-� � � � o �, � �� ° �
<br /> � �� PROVIDE VISION PANEL IN DOSTING DOORS. SEE ELEVATION ON A7.1 0
<br /> ,� �- r � �, L000��.-� oo � oo
<br /> Q °'�� °-a.�� ot o >,� i �=o �
<br /> ❑ I. MODIFY EXISTING SUBSTRAIE ec RFn naFn T� R��� �w��nn�tiN�-41A?�4.� ?H��c P4�lI1N� v i Q Q a y z o� a 3 Q � Q a°a a
<br /> NOTICEABLE LUYPS OR DEPRES�ONS.
<br /> K E Y P LA N F I R S T S T O RY K E Y P LA N T H I R D S T O RY J• All Y�tK SHALI- BE ERECTED AND INSTAIlED PLUMB, LEVEL, SQUARE AND TRUE � � � � o � J
<br /> E--i N O M � d
<br /> SCALE: 1/32" - 1'-0" SCALE: 1/32" - 1'-0" K. R ff E R T 0 1 1 1 L L W a R K S H O P D Y Y G S F O R S P E C I Fl C D E T A I L S O F C O O R D I N A T I O N B E T W E E N � °° � �; �,
<br /> _ _ DRYWAIl/IrtILLWORK CONDI110NS. � W ci� o o°Oo � .a
<br /> H ' �,�� o
<br /> L ALL DOSTING AND NEW FLOOR PENETRATIONS FOR PiPING SHALL BE FULLY PAG(ED AND SEALED IN � � � � c� � �
<br /> ACCORDANCE WI1H 1HE APPl1CABLE BUILDING AND FlRE CODES. x � �' � � a
<br /> � x � �
<br /> U O � � � �
<br /> M. ALL I�fLLWORK TO BE fASTENED TO THE PART1TlON. PROVfDE NON-COMBUSTIBLE BL(xKING FOR ALL � Z � � �
<br /> �IIILWORK NOT SUPPORTED BY fL00R OR ABOVE 4'-0' HT. At1 CONCEAIID LU�16ER dc BLOq(ING � � � o o E �
<br /> T O B E Fl R E T R E A T E D. � � � � C O
<br /> � ¢ � � � o
<br /> N. GC TO PROVIDE SHOP DWGS FOR CASEWORK. � � O
<br /> �' � � �
<br /> e— N p,
<br /> M � �,
<br /> o i � _ _
<br /> ELECT. NOTES ° ~ �
<br /> � ! � A. FURNlSH AND INSTALL ALL FIXTURES, ASSOCIATED TRIM AND FIXTURE LAMPS AS
<br /> REQUIRED. ONLY NEW OUTLETS/FIXTURES ARE SHOWN. ALL EXISTING OUTLETS
<br /> � UNAFFECTED BY CONSTRUCTION ARE TO REMAIN AND ARE TO BE INTEGRATED
<br /> - INTO THE CURRENT SCHEME WHERE POSSIBLE.
<br /> � �
<br /> S SS B. SURVEY FlELD CONDITIONS AND VERIFY THAT WORK IS FEASIBLE AS SHOWN.
<br /> VERIFY LOCATION OF ALL OUTLETS IN RELATION TO STRUCTURAL AND OTHER
<br /> � ! ELEMENTS AS REQUIRED. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES
<br /> � _ BEFORE PROCEEDING WITH WORK.
<br /> EXIT �T = � C. ELECTRICAL ENGINEER'S POWER PLAN SHALL GOVERN THE WIRING LAYOUT AND
<br /> '� INSTALLAl10N IN COMPLIANCE WITH ALL LAWS APPLICABLE AND ENFORCED BY
<br /> � EX T c U' "' ' GOVERNING AUTHORITIES.
<br /> o �
<br /> � � D. OUTLETS SHOWN BACK TO BACK ON PARTITION WALLS SHALL BE OFFSET 1'-0" �
<br /> �� S S S -� I�AX., OR MOUNTED AT DIFFERENT HEIGHTS, IF INDICATED. z
<br /> _ E. UPON COMPLETION OF OUTLET LAYOUT, NO11FY THE ARCHITECT. ARCHITECT O W
<br /> � ' SHALL SITE VERIFY ALL OUTLET LOCATIONS PRIOR TO COMMENCEMENT OF - �
<br /> CORING OR OUTLET INSTALLATION. �n
<br /> � � � � � F. INSTALL WALL MOUNTED OUTLETS 18" ABOVE FINISHED FLOOR, U.O.N. HEIGHTS Z W
<br /> � TRAINING �� �� ,� �, � ❑ SHALL BE DETERMINED FROM FINISHED FLOOR TO THE CENTERLINE OF COVER
<br /> ROOM CONFERENCE � PLATE, INSTALLED VERTICALLY, GROUNDING POLE AT TOP, U.O.N. � >
<br /> 102 ROOM S
<br /> 2 4 6 7 103 � G. MAINTAIN A 4° HORIZONTAL CLEARANCE IN ALL DIRECTIONS, �IIN. FROM EDGE OF L.L O
<br /> 8 9 10 " 5 6 � 8 _ COVER PLATE, FOR WALL MOUNTED OUTLETS, OR FROM EDGE OF MONUMENT FOR
<br /> c 9 10 � S S _ �OOENMODU.O.N.OUTLETS, WHEN ADJACENT TO A WALL, COLUMN, OR SIMILAR � �
<br /> W � �
<br /> � , H. GANG COVER PLATES SHALL BE ONE-PIECE TYPE. U.O.N. � � �
<br /> � ___
<br /> I. ELECTRICAL SWITCH AND OUTLET COVER PLATES. SURFACE HARDWARE, ETC. � �
<br /> = LAN ROOM SHALL BE INSTALLED AFTER PAINTING AND/OR APPLICATION OF WALL COVERINGS n �
<br /> ❑ ❑ � ¢ 303 S & CARPET SPECIFIED. �-+- � } o
<br /> WN
<br /> � = o - J. COORDINATE ALL ELECTRICAL AND DATA REQUIREMENTS WITH THE TENANT � �
<br /> � - GUIDELINES. PROVIDE GFl OUTLETS AT All WET AREAS. Q �
<br /> � , � - - � Q
<br /> � c c _ � d � . f3 � Q Q �
<br /> O P ARE O R K - � � R A3 - K SHARLLI BE MOUNTED HORI�ONTALLY REQUIRED. "H" INDICATES THAT AN OUTLET '^ � � �
<br /> - � � tlJzzmW
<br /> �
<br /> � �01 � � OFFI 3 � = L. VERIFY NEW FLUSH FLOOR OUTLET LOCATIONS 1MTH FURNITURE LAYOUT PRIOR TO U W � Z �
<br /> � 6 7 8 �° ,� �� 104 RppM II INSTALLATION, IF APPLICABLE � � j
<br /> �� - � � 300 � � � m o� W
<br /> o Q
<br /> _ - - 3 104 " 6 �� WALL LEGEND
<br /> ___
<br /> _ ' REVISIONS
<br /> � � _, = N0. DATE BY
<br /> ; � � � [� � SHADED WALLS INDICATE NEW WORK:
<br /> �, � 12.06.18 CITY
<br /> -- __-- ___- ---
<br /> p c i � c c c - NEW FULL HQGHT PARilTION TO 6' ABOVE (�21D: 2-t/2' �ITL STUDS 25 � 0208.19 CITY
<br /> - S -- ---- . --� � GA.) AT 24' O.C. WITH 5/8' GWB EACH SIDE TO GRID. 2
<br /> BREAK � � � � A9.1 /�
<br /> ROOM 03.18.19 CI TY
<br /> - _ = 6 4'-0" 2'-0" 4'-0° 2'-0" 4'-0" 2'-0° 4'-0" 2'-0" 4'-0� 6" S �
<br /> 100 " - NEW DOOR. REFER TO KEYS ON PLAN AND SEE DOOR SCNEDULE, SHEET 4
<br /> ❑ 6 � 8 4?FROIYIOAD ACENT PEREPENDICULAR W(A�D N E�TO BE LOCATED A NIN. �
<br /> 9 10 - f�l
<br /> � o � 11 6
<br /> a 7.� CONFERENCE S 100A
<br /> ROOM ISSUE DATES
<br /> -- _ _ _ 301 O NEW RELJTE ASSaIBLY. REFER TO DOOR SCI�DULE, SHEET A7.1 FOR �IORE DESI GN AP PROVAL:
<br /> S o S �F�A¶�' PERMIT SUBMITTAL:
<br /> � E PERMIT RECEIVED:
<br /> EXIT EXIT
<br /> e� EXISTING CONSiRUCTION TO RE�INN. BID DOCS:
<br /> CONSTR. DOCS:
<br /> 24"x36"SCALE: AS NOTED
<br /> EL E CT. L E G E N D PLOT DATE: 2019-03-22 '
<br /> FI RST STORY FLOOR PLAN TH I RD STORY FL40R PLAN CADFILE: 18-088_A2.1
<br /> MOUNTtNG HEIGHTS PER DETAIL 12, SHEET A9.1, U.O.N. JOB NUMBER: 18-088
<br /> SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" � DUPLEX RECEPTICLE CHECKED: CS
<br /> DRAWN: TSJ
<br /> 4 DATA OUTLET
<br /> STATUS: PERMIT
<br /> � VOICE/DATA OUTLET
<br /> � c� 4—PLEX OUTLET FLOOR PLAN
<br /> � CARD KEY READER (R) INDICATED REUSED
<br /> ■
<br />
|