Laserfiche WebLink
� FLOOR PLAN NOTES: S I A L E R <br /> A3.1 <br /> . WRITfEN DIMENSIONS TAKE PRECEDENCE OVER D E 5 I C, N L L C <br /> SCALED DIMENSIONS. VERIFY ALL DIMENSIONS AND R E S I D E N T i A L-C O M M E R C I A L <br /> 42'-0" CONDITIONS IN THE FIELD. <br /> . SEE ROOF FRAMING FORALL HEADERAND <br /> NOTES: FINISH FLOOR 3-0 12-7 2-10 5-0 7-10 1/2 �g_g ��2 BEAM CALL-0UTS. <br /> � �� � „ � �� � �� � �� � �� <br /> WINDOW WELLS WITH A VERTICAL DEPTH <br /> GREATER THAN 44 INCHES SHALL BE EQUIPPED . MAIN FLOOR PLATE HEIGHT SHALL BE 8'-0",TYP. <br /> WITH A PERMANENT�YAFFIXED LADDER OR I U.N.O. <br /> 23003 55TH AVE W, <br /> e ♦ TOP OF WINDOWS @ T-O°ABOVE FLOOR,TYP. MOUNTLAKE TERRACE, WA 98043 <br /> STEPS USABLE WITH THE WINDOW IN THE N CE��:425-877-7377 <br /> FULLY OPEN POSITION. LADDER OR STEPS � _ U.N.O. EMAIL:SIALERDESIGN�Q GMAIL.COM <br /> REQUIRED BY THIS SECTION SHALL NOT BE N "'�� ��1 . EXTERIOR WALLS SHALL BE 2�c6 HF @ 16"o.c.AND � <br /> REQUIRED TO COMPLY WITH SECTIONS R311.5 � .Ji �� � � WET BAR INTERIOR WALLS 2x4 HF @ 16"o.c. <br /> AND R311.6. LADDER OR RUNGS SHALL HAVE N I OWE B <br /> AN INSIDE WIDTH OF AT LEAST 12 INCHES, � • ALLANGLED WALLS TO BE 45°U.N.O. <br /> SHALL PROJECT AT LEAST 3 INCHES FROM THE � A � . ALL WINDOWS OOD,ALUMINUM,OR ' <br /> WALL AND SHALL BE SPACED NOT MORE THAN y � , I � : � VINYL)SHALL COMPLY W/W.S.E.C. i <br /> 18 INCHES ON CENTER VERTICALLY FOR THE � � , <br /> FULL HEIGHT OF THE WINDOW WELL TOP OF WINDOW AT 6'-10" - _ �` ( m Z o FRAMERS TO VERIFY ROUGH OPENING i i <br /> - � o WINDOW - � o � m ! � <br /> � WELL _ W � � I c� � • PROVIDE SOLID BLOCKING OVER i i <br /> ao --- <br /> , .. , _ � � SUPPORTS. � <br /> F� , <br /> a ' °: � W - � - ------ • SMOKE ALARMS TO BE HARD WIRED w/ j ; ; <br /> ., � o _ ORAGE DISCONNECTION SWITCH AND BATTERY � <br /> .' CLOEAR.WINDOW OPENING SILL HEIGHT SHALL � BATH � � _ ______ BACKUP. DEVICES TO BE INTERCONNECTED IN � <br /> GUEST BEDROOM r��E m ACCORDANCEw/SECTION�1�'IRC. <br /> a�. ` NOT EXCEED 44 INCHES ABOVE SLAB PER IRC CARPET O � UP �, <br /> • �. 310.1 _ _ _ • SMOKE DETECTORS TO BE LOCATED <br /> F- � � �p � SD � %� THE5E DRAWINGS ARE COPYRIGHTED AND MAY <br /> _ � - � � � N INALLBEDROOMS. � >l�' NOT BE COPIED ❑R REDRAWN WITHOLJT THE <br /> C7 � OPENABLE WINDOW SPACE SHALL COMPLY ' N � M : m m � WRITTEN PERMISSION ❑F SIALER DESIGN LLC. <br /> w :.a �_ �� � � m m M _ . HANDRAILAT STAIRS TO BE MOUNTED u s E ❑F T H I S D R A W I N G i s L I M 1 T E D r❑ a <br /> _ . WITHIRCR310.1 M N N LIN�N N REC ROOM � AT34��-3H��ABOVETREADNOSINGIN SPECIFIC PROJECT FOR PERSONS NAMED <br /> _� J ' �� 3G��MIN. PER I R310.2 � � � ACCORDANCEw/-+�2#��6.6;IRC. ) ;y � HEREON AND FOR THE CONSTRUCTION OF ❑NE <br /> Q .� �. PROVIDE EGRESS FROM WINDOW WELL PER H�ND N �'��/' 1 `'� ' � i�� srR cr�YGPROH BITED WITHOUT�THE WRITTEN <br /> � �� a IRC310.2.1 = � _ coNSENT FROM SIALER DESIGN LLC. <br /> T.O.SLAB=498.45' • �DENOTES SOLID BEARING UNDER <br /> • ..: � CONCENTRATED LOADS. USE(2)2x6 COPYRIGHT 201 5 <br /> � ' 44"MAX_TO CLEAR OP NING _ - 2 - - ��S � $�K _ _ _ _ _ _ _ _ _ 2 AT 6"WALLS. USE(2)2x4AT4"WALLS. CO SIALER DESIGN ��c <br /> _ A3. �O C OSD 1�"SOLID CORE DOOR A3• UNLESS NOTED OTHERWISE. <br /> •", -' M MONOXIDE io . VENTALL FANS AND DRYER EXHAUST <br /> WITH SELF-CLOSING <br /> ' � -' �" C TILE DETECTOR I TO EXTERIOR. <br /> REVISIONS <br /> � �"`�"" ' �O I � EFFICIENT WATER HEATWG <br /> ___ <br /> .. . _ _.____ � LAU N DRY <br /> .•. � • . � � . ALL STORAGE&SPACES UNDER STAIRS TO BE DATE DESCRIPTION <br /> : • � ; a �'�- g g o MIN EF OF 2A(OPTION 5b) <br /> I FINISHED w/1/2"GWB. 09/30/15 PERMIT SUBMITTAL <br /> \� 2 6 � � <br /> •• ' ' R-211NSUL. ``�., <br /> , . ..:�• •�'' �� . ,Y,, STRAP HWT TO . DOOR BETWEEN HOUSE 8 GARAGE SHALL BE A <br /> � . .� •• ,�� "� ' o o FRAMINGAT lW0 o SOLID CORE WOOD DOOR,SOLID OR 11/20/15 CORRECTION PER CITY <br /> ' . . .,� ; i� - _ H� LOCATIONS AT THIRD ' O OT LESS THAN <br /> ,. : :.� a � � <br /> � , � , � � HONEYCOMB STEEL DO R N <br /> , , �?, � � �� :` : �_ �� �_ POINTS � 1-3/8"IN THICKNESS. <br /> . . � 1 � 11 5 8 11 ' " 19'-2„ <br /> '• ' � ' •�� � ' � • � � � i��i � i� • PREFABRICATED FIREPLACES,CHIMNEYSAND <br /> .�. <br /> a : ' . �� � � �G�I �,,��, � � OA � ELECTRIC FURNACE RELATED COMPONENTS TO BEAR U.L.OR <br /> . � ' � ��L � ' B�BB Oo :�>/y,� f.�,/.;4� � I.B.C.O.SEAL OFAPPROVALAND TO BE <br /> .. , <br /> . � � INSTALLED PER MANUFACTURERS <br /> .. <br /> • •. ;�/� ��Q hl w I t F R SPECIFICATIONS. <br /> . C' � , ��.A� � � � <br /> °. � � . � �,;1,�-�-- ) � � ( ��� � • TOILET PAPER DISPENSERS TO BE MOUNTED P ROJ ECT . <br /> ' � " � ��'���.�.�.`�'��., DIAZ RESIDENCE <br /> •� � . o <br /> � � ��' � _ p • ALL TOWEL BARS TO BE 24"WIDE,MOUNT <br /> .a• .� •:� . O I ; (�l ��"��� ���'` TOWEL (�42"A.F.F. 2802 VICTOR PL <br /> FILTER �� :•�" � •a •� • � � � � (�,. r . FIREBLOCKING AT OPENING AROUND VENTS, <br /> FABRIC Q I E �j�G�(L� ; � � �� , r � � � EVERETT, WA 98201 <br /> • •.n .�..� .,.a. R-10 INSUL. _ � I O A3.1 Q �, /�J i/lI 17H AND FLOOR LEVELB,WITH AN A PROVAL EILING <br /> 4"D I A. F O O T I N G • • '�'.. � D R I V E W A Y o _ _ _ �) W � �v" '�� M A T E R I A L T O R E S I S T T H E F R E E P A S S A G E O F <br /> DRAIN TO APPROVED N � G A R A G E F L A M E A N D P R O D U C T S O F C O M B U S T I O N <br /> DRAINAGE SOURCE � 4"CONC SLAB � , t f.�U m �� _[� /f �O �,� r C L I E N T . <br /> - SLOPE 3"TO DOOR ;�,�� UT v <br /> KEY NOTES: DIAZ WALTER & <br /> o � -���N� ��� �r�'���D� �'� � BAUTISTA NANCY <br /> Cr� � EFFICIENT WATER HEATER MIN EF OF 2.0 <br /> w `- <br /> o � ( ���',,�,� s �oR71��l� ��'�''a`�� 19208 48th AVE W <br /> WINDOW WELL DETAIL � � ` �� C t S f Og HEATELEMENTSANDSWITCHESTOBE18" LYNNWOOD, WA98036 <br /> � �4�=,�-0�� o I u�1 �r� � <br /> ��._ �-!G!�� ��1� .s ABOVE CONCRETE SLAB. <br /> � I L O 18���4"CRAWL SPACEACCESS <br /> x '.,.��.�_� !.l:.,t�7�...n.`.s. <br /> 4 C� PROVIDE 2x8 BLOCKAT 54"A.F.F.FOR <br /> °O _ _ _ � THERMOSTAT(SEE SHEET ECI) <br /> � � 1/2"GYPSUM WALL BOARD ON ALL WALLS AND S H E ET NAM E. <br /> P O S T S. 5/8"T Y P E'X'G Y P S U M W A L L B O A R D O N <br /> CEILINGSAND BEAMS. 5/8"TYPE'X'G.W.B.SHALL LOW E R F LOO R <br /> 21'-0" 21'-0" BE INSTALLED PERPENDICULAR TO THE CEILING <br /> FRAMING AND SHALL BE FASTENED AT MAX.6 <br /> 42'-0" INCHES O.C.FASTENERS PER TABLE R702.3.5. P LAN � F LOO R <br /> LOWER FLOOR PLAN � TOBE NSTA LEDPERMAN FAC URERS PLAN N4TES <br /> N SCALE 1/4 - 1 -0 <br /> SPECIFICATIONS.PREFAB FIREPLACES <br /> TO BEAR THE STAMP OF AN APPROVED <br /> TESTING LAB. PROVIDE 6"DIM. <br /> OUTSIDE COMBUSTION AIR. <br /> HEARTH PER BUILDER/OWNER. <br /> ,-,���DIA.MINCOM: TUBS & SHOWERS: <br /> SHEARWALL SCHEDULE HANDRAIL-1-1I2��CLEAR <br /> FROM WALL. <br /> HANDRAILS PER IRC R311.5.3 <br /> • FIREBLOCKING IN ACCORDANCE W/SECTION <br /> BALUSTERS PER <br /> R602.8, I RC. /? �.=���• i� <br /> TYP. EXT. WALL CONSTRUCTION IRC R312.3 . LIMIT SHOWER FLOW TO 2. 5 G.P.M. <br /> SW� TOPOFHANDRAIL ENERGY CODE COMPLIANCE <br /> (UNLESS OTHERWISE NOTED) • WALLS SHALL BE WATERPROOF TOAMIN.70" <br /> � ENERGY CREDIT TABLE R406.2: OPTION 5b for 1.5 Credit � <br /> 1.SHEATHING: 1/2"PLYWOOD OR 7/16"O.S.B.,EXTERIOR SIDE,BLOCKED, o ABOVE DRAIN INLET. <br /> o LESS THAN 4" BM. OR DBL f�, �' <br /> NAIL w/8d @ 6"O.C.ALL EDGES AND�12"O.C.FIELD. � BETWEEEN PER PLAN '� � '.� � • ALL GLAZING INCLUDING WINDOWS WITHIN 60" <br /> = z 1x8 BALUSTERS � :� / �� � � OF STANDINGNVALKING SURFACE SHALL BE <br /> 3.NAIL BOTTOM PLATE TO FRAMING BELOW w/16d @ 4"O.C. � � � R�XER � WHOLE-HOUSE VENTI LATION °,�.� � � ZM"� SAFETY GLASS. <br /> 4.FASTEN DOUBLE PLATE TO JOIST OR BLOCKING ABOVE PER � Q PER M 1507.3 5 � � <br /> DETAILS ON S1 &S2. Q Z � EXTEND TO TOP TREAD WHOLE-HOUSE VENTILATION INTEGRATED WITH A �� "� <br /> z � o &BOTT. RISER FORCEDAIR SYSTEM <br /> CAPACIN:240 LB/FT� � � � RETURN TO WALL ` " <br /> ._! ,. <br /> � 10"TMP�SEEP'�"� �' ' APPROVED <br /> m (10"MIN.REQ.) <br /> _ _ _ a TREAD 1/2"GWB ON ALL U-FACTOR <br /> INDICATES SHEARWALLw/PLYWOOD ONE SIDE. SURFACES OF ALL WINDOWS AND DOORS MUST HAVE <br /> SW� USABLE SPACE U-FACTOR=0.30 OR BETTER <br /> 1. SHEATHING: 1/2"PLYWOOD OR 7/16"O.S.B.,ONE SIDE,BLOCKED, g <br /> NAIL W/8d@ 4"O.C.ALL EDGESAND 12"O.C.FIELD. � �w UNDER STAIRS BLOWER DOOR TESTI NG <br /> 2. BOLT SILL PLATE TO CONCRETE w/5/8 DIA.x 10"A.B.'S @ 32"O.C. " �"' PROVIDE A WRITTEN REPORT OF THE TEST RESULT, <br /> (3)2 x 12 STRINGERS SIGNED BY THE TESTING PART,TO THE BUILDING <br /> 3.NAIL BOTTOM PLATE TO FRAMING BELOW w/16d @ 3"O.C. ?x THRUST FIREBLOCKING AT <br /> INSPECTOR, PRIOR TO APPROVED FINAL INSPECTION. <br /> BLOCKING TOPAND BOTTOM <br /> PER DETAILS ON S1 &S2. BETWEEN STUDS R INSULATION CERTIFICATE <br /> CAPACITY:350 LB/FT NOTE: THE DESIGN PROFESSIONAL OR BUILDER SHALL <br /> PER IRC 2012 CODE R311.7.5 STAIRS TREADS AND RISERS COMPLETE AND POST A"INSULATION CERTIFICATE FOR H O U S E V E N T I LAT I O N <br /> RESIDENTIAL CONSTRUCTION"WITHIN 3'OF THE FLOOR AREA SUMMARY. <br /> R311.7.5.1 RISER HEIGHT.THE MAXIMUM RISER HEIGHT SHALL BE 7 a' �I A/�,� E L E C T R I C A L P A N E L P R I O R T O F I N A L I N S P E C T I O N. <br /> INCHES(196 mm).THE RISER SHALL BE MEASURE VERTICALLY P �i� 2012 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1507, INTERMITTENT LOWER FLOOR = 915 SQ. FT. <br /> 2gW� � � � INDICATES SHEARWALL w/PLYWOOD TWO SIDES. pF�sy� <br /> BETWEEN LEADING EDGES OF THEADJACENTTREADS.THE ,�.� � ti� W H O L E H O U S E V E N T I L A T I O N U S I N G E X H A U S T F A N P E R 1 5 0 7.3, T A B L E 1 5 0 7.3.3(1) M A I N F L O O R = 1 0 9 2 S Q. F T. <br /> 1. SHEATHING: 1/2"PLYWOOD OR O.S.B.,TWO SIDES,B�OCKED, NAIL GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIR SHALL NOT he o PROVIDE A PROGRAMMABLE THERMOSTAT FOR THE � <br /> w/8d @ 3"O.C.ALL EDGES AND @ 12"O.C. FIELD. EXCEED THE SMALLEST BY MORE THAN�"INCHES(9.5 mm). �' z PRIMARY SPACE CONDITIONING SYSTEM WITHIN EACH &TABLE 1507.3.3(2), PROVIDE CONTROLS PER 1507.3.2. COMPLY WITH WSEC UPPER FLOOR = 784 SQ. FT. PROJECT NUMBER: 2015-13 <br /> DWELLING UNIT PER SEC R403.1.1 R 4 0 3.5 <br /> 2. BOLT 3x SILL PLATE TO CONCRETE w/5/8"DIEbc10".EXP. BOLTS (i�8"O.C. R311.7.5.2 TREAD DEPTH THE MINIMU READ DEPTH SHALL BE 10" A 27752 O �- SYMBOL LOCATION MINIMUM FAN REQUIREMENTS TOTAL = 2,791 SQ. FT. DATE: 09-30-15 <br /> F��STE�� `'� G A R A G E = 5 4 6 S Q. F T. CHECKED: <br /> I N C H E S(2 5 4 mm.).T H E T R S H A L L B E M E A S U R E D � �� <br /> 3. F2 L�A�YE SB 6d O 6'olc.OR 2 ROWS A35 CL PIST O SB�LOCKING BLW.w/2 ROWS HORIZONTALLY BETWEEN THE VERTICAI PLANES OF THE FOREMOST F`��ONAL ENG\� A MINIMUM OF 75%OF PERMANENTLY INSTALLED A Bath 8� Min. 50 cfm (INTERMITTENT) � .025 WG (TABLE M1507.3) _ <br /> � � PROJECTION OFADJACENTTREADSANDATARIGHTANGLE TOTHE LAMPS IN LIGHTING FIXTURE SHALL BE HIGH-Eff'IGfE#fi � Powder COVERED PORCHES - 62 SQ. FT. DRAwN: �S <br /> 4. FASTEN DBL.TOP PLTS.TO DOUBLE JOIST OR BLOCKING ABV.w/2 ROWS TREAD'S LEADING EDGE.THE GREATEST TREAT DEPTH WITHIN ANY �MPS �����j�,��, KltChe� Min. 100 cfm (INTERMITTENT)� .025"WG (TABLE M1507.3) � �� � �� <br /> A35 CLIPS 16"o.c.OR PER DETAILS ON S/1 8�S/2 FLIGHT OF STAIR SHALL NO EXCEED THESMALLEST BY MORE THAN�" ���s srzarzo» � a.- �` g WIDTH = 26-O DEPTH =42-0 STATUS: SUB-1 <br /> @ a � (Range hood or down draft exhaust fan rated at min. 100 cfm <br /> INCH(9.5 mm.). FOR LATERALAND at 0.10"wg may be used for exhaust fan requirement.) <br /> 5. USE 3x STUDS @ALL FRM'G.MEMBERS RECEIVING E.N. FROMADBUTTtNG PANELS _ �-- SQUARE FOOTAGE IS MEASURED TO THE OUTSIDE <br /> Gw4v�n oN�Y WE3TE: ..---� Laundry Min. 180 cfm (INTERMITTENT) � .025"WG-to function and be FACE OF WALLS. STAIRSARE COUNTED <br /> CAPACITY:900 LB/FT � I i P. I NTE RI O R STA I R FRESH f�TR�QVIDED BY WHOLE-HOUSE FX�bact�T FAN �C Room labeled as whole house fan (4-5 BEDROOMS 3001<4500 SF.)TO APPROXIMATELY ONEAND ONE HALF TIMES. OPEN <br /> WITH FRESH AIRPf)RT„(NET 4 SF l[�Mi1Q.OPENING)AT OPERATE AT LEAST 50% OF TIME IN EACH 4-HOUR SEGMENT TO BELOW SPACESARE NOT INCLUDED IN <br /> 314"=1'-0" STAIR �C 1 EACH HABITABLE ROOM�►�#11�R OPERATES AN CALCULATIONS.GARAGE AREA IS CALCULATED <br /> EXHAUST FAN V1(��ULLS OUTS(QE AlR THROUGH DRYER VENT PER (TABLE M1502.4.4.1)VENTED TO OUTSIDE SEPARATELY. <br /> AIR IN�ET$'t�CATED IN EACH HABITABLE ROUM.. ,_ *ALL FANS TO VENT TO OUTSIDE <br /> ■ <br /> PLOT SCALE: 1:1 <br />