Laserfiche WebLink
DESIGN BUILD NOTES KEY NOTES X , <br /> 0 GENERAL NOTES <br /> PROJECT TO BE ELECTRICAL AND MECHANICAL DESIGN-BUILD. NEW LIGHTING SHALL MEET C405.2.1 OCCUPANCY SENSORS. OCCUPANCY SENSORS SHALL BE INSTALLED IN 2. STEPPED DIMMING USING MULTI-LEVEL SWITCHING AND DAYLIGHT-SENSING 1. CEILING GRID START POINT 1. THE REFLECTED CEILING PLAN INDICATES THE LOCATION OF CEILING <br /> THE FOLLOWING MINIMUM REQUIREMENTS: ALL CLASSROOMS, CONFERENCE/ MEETING ROOMS, EMPLOYEE LUNCH AND CONTROLS THAT ARE CAPABLE OF REDUCING LIGHTING POWER AUTOMATICALLY. THE 2. ON INTERIOR WALLS ADD 6005137-54 STUD BRACE TO TOP WALL, TYP, HEIGHTS, LIGHT FIXTURES, SWITCH LOCATIONS, AND ASSOCIATED ITEMS. <br /> A. IBC 1008.1 - ILLUMINATION REQUIREMENT BREAK ROOMS, PRIVATE OFFICES, RESTROOMS, WAREHOUSE SPACES, STORAGE SYSTEM SHALL PROVIDE A MINIMUM OF TWO CONTROL CHANNELS PER ZONE AND BE CONTINUOUS BETWEEN PERPENDICULAR WALLS, WITH #8 SCREWS AT 12" O.C. REFER TO ENGINEERING DRAWINGS FOR CIRCUITING, WIRING LAYOUT,AND Nelco Architecture, II1C, <br /> 1. THE MEANS OF EGRESS, INCLUDING THE EXITDISCHARGE, SHALL BE ROOMS AND JANITORIAL CLOSETS, AND OTHER SPACES 300 SQUARE FEET(28 INSTALLED IN A MANNER SUCH THAT AT LEAST ONE CONTROL STEP IS BETWEEN 50 3. AT WALL LENGTHS LONGER THAN 18' BETWEEN PERPENDICULAR WALLS, ADD ADDITIONAL INFORMATION. ALL MEP-FP DEVICE LOCATIONS NOT SHOWN ON <br /> ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE M2) OR LESS ENCLOSED BY FLOOR-TO- CEILING HEIGHT PARTITIONS. THESE PERCENT AND 70 PERCENT OF DESIGN LIGHTING POWER AND ANOTHER CONTROL STEP 600S137-54 STUD, FLAT TO TOP OF WALL AS SHOWN WITH (4) #8 SCREWS IN DRAWINGS, OR IN CONFLICT WITH MEP/FP DRAWINGS, ARE TO BE <br /> MEANS OF EGRESS IS OCCUPIED. AUTOMATIC CONTROL DEVICES SHALL BE INSTALLED TO AUTOMATICALLY TURN IS NO GREATER THAN 35 PERCENT OF DESIGN POWER, AND THE SYSTEM I5 CAPABLE EACH END TO CONTINUOUS BRACE (COPE FLANGES ON ANGLE BRACE) COORDINATED WITH ARCHITECT PRIOR TO INSTALLATION. IN THE EVENT OF <br /> B, IBC 1008.2.1 - ILLUMINATION LEVEL OFF LIGHTS WITHIN 30 MINU7ES OF ALL OCCUPANTS LEAVING THE SPACE, AND OF AUTOMATICALLY TURNING THE SYSTEM OFF. DISCREPANCIES BETWEEN THE ARCHITECT'S REFLECTED CEILING PLAN AND <br /> 1. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 SHALL EITHER BE MANUAL ON OR SHALL BE CONTROLLED To AUTOMATICALLY THE ENGINEERS� PLAN5,IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING 1200 Fifth Ave. <br /> FOOT-CANDLE (11 LUX)AT THE FLOOR LEVEL. TURN THE LIGHTING ON TO NOT MORE THAN 50 PERCENT POWER. C408.2.3 FUNCTIONAL TESTING. TESTING SHALL ENSURE THAT CONTROL HARDWARE AND BEFORE ORDERING MATERIALS OR PROCEEDING WITH THE WORK. SUlte 'I3OO <br /> C. IBC 1008.3 - ILLUMINATION EMERGENCY POWER SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING 2. FOLLOWING COMPLETION OF THE ACOUSTICAL CEILING INSTALLATION, ALL Seattle, WA 98101 <br /> 1. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL C405.2.4 DAYLIGHT ZONE CONTROL. DAYLIGHT ZONES SHALL BE DESIGNED SUCH CONDITION IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND MANUFACTURER'S JOINTS AND GRID SHALL BE STRAIGHT TRUE TO LINE WITH EXPOSED <br /> NORMALLY BE PROVIDED BY THE PREMISE'S ELECTRIC SUPPLY. THAT LIGHTS IN THE DAYLIGHT ZONE ARE CONTROLLED INDEPENDENTLY OF INSTALLATION INSTRUCTIONS. ' ' Phone: (206)408-8500 <br /> 1.1 LOCATIONS INCLUDE: DEDICATED EGRESS ROUTES IN LARGER ROOMS GENERAL AREA LIGHTING AND ARE CONTROLLED IN ACCORDANCE WITH NEW HVAC SOLUTION SHALL MEET THE FOLLOWING MINIMUM RE UIREMENT: SURFACES FLUSH AND LEVEL. DIRTY OR DISCOLORED 5URFACES OF TILE ARE WWW NEL50NWORLDWIDE.COM <br /> R TO BE CLEANED OR REPLACED, AND LEFT FREE OF DEFECTS. AFTER 30 DAYS <br /> OR SPACES, PUBLIC OR COMMON EGRESS ELEMENTS, ESSENTIAL SECTION C405.2.2.3.2. EACH DAYLIGHT CONTROL ZONE SHALL NOT EXCEED A. NEW MECHANICAL ELEMENTS, INCLUDING BUT NOT LIMITED TO PACKAGED UNITS, FROM SUBSTANTIAL COMPLETION, INSPECT THE WORK AND ADJUST TILE NOT <br /> PORTIONS OF THE INTERIOR EGRESS SYSTEM, INTERIOR EXIT 2,500 SQUARE FEET (232 M2). CONTIGUOUS DAYLIGHT ZONES ADJACENT TO CONTROLS, DAMPERS, DUCTING, COMMISSIONING; TO FULLY COMPLY WITH THE IN ALIGNMENT WITH OTHER CEILING TILES AND REPLACE MISSING OR <br /> DISCHARGE ELEMENTS, AND EXTERIOR PORTIONS OF THE EXIT VERTICAL FENESTRATION ARE ALLOWED TO BE CONTROLLED BY A SINGLE PROVISIONS OF WSEC SECTION C403, DAMAGED UNITS. <br /> DISCHARGE, INCLUDING INTERIOR EXIT STAIRWAYS&RAMPS. CONTROLLING DEVICE PROVIDED THAT THEY DO NOT INCLUDE ZONES FACING B. VENTILATION REQUIREMENTS FOR RESTROOMS PER WASHINGTON STATE 3. WITHIN A ROOM OR AREA,THE CONTRACTOR SHALL ESTABLISH A SINGLE <br /> 2. PER IBC 1008.3.3, IN THE EVENT OF POWER SUPPLY FAILURE, AN MORE THAN TWO ADJACENT CARDINAL ORIENTATIONS (I.E.,NORTH, EAST, MECHANICAL CODE (WAC 51-52) FLOOR ELEVATION THAT IS TO BE USED AS THE ORIGIN FOR ALL CEILING <br /> EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE SOUTH, WEST). THE PRIMARY DAYLIGHT ZONE SHALL BE CONTROLLED C. ALL OCCUPIED SPACES SHALL BE VENTILATED BY MECHANICAL MEANS IN HEIGHTS ABOVE FINISHED FLOOR. <br /> FOLLOWING AREAS: ELECTRICAL EQUIPMENT ROOMS, FIRE COMMAND CENTERS, SEPARATELY FROM THE SECONDARY DAYLIGHT ZONE. DAYLIGHT 20NES UNDER ACCORDANCE WITH SECTION 403 IN THE 2015 INTERNATIONAL MECHANICAL CODE 4. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL MEP/FP AND STRUCTURAL <br /> FIRE PUMP ROOMS, GENERATOR ROMS, PUBLIC RESTROOMS WITH AN AREA SKYLIGHTS MORE THAN 15 FEET(4572 MM) FROM THE PERIMETER SHALL BE THE VENTILATION SYSTEM SERVING THE SPACE SHALL BE DESIGNED TO PROVIDE ELEMENTS. CONTRACTOR TO COORDINATE THE WORK OF ALL TRADES <br /> GREATER THAN 300 SF. DURATION OF EMERGENCY POWER SHALL BE PER CONTROLLED SEPARATELY FROM DAYLIGHT ZONES ADJACENT TO VERTICAL VENTILATION OVER AND ABOVE THAT REQUIRED BY TABLE 403.3.1.1 IN ACCORDANCE NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED. <br /> 1008.3.4: NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE FENESTRATION. WITH ACCEPTED ENGINEERING PRACTICE. INSTALL DUCTWORK TIGHT TO UNDERSIDE OF BEAMS, WITH A SMALL SPACE <br /> BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. ILLUMINATION LEVEL CONTROL SHALL: NEW EXIT SIGNAGE SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: TO AVOID VIBRATION. INSTALLATION AND/OR ALTERATION OF DUCTWORK, <br /> UNDER EMERGENCY POWER PER 1008.3.5: INITIAL ILLUMINATION NOT LE55 1. CONTROL ONLY LUMINAIRES WITHIN THE DAYLIT AREA. A. ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND PIPING OR OTHER EQUIPMENT THAT WILL REQUIRE FASCIAS, SOFFITS AND <br /> THAN1 FC, MINIMUM AT ANY POINT OF 0.1 FC MEASURED ALONG THE PATH OF 2. INCORPORATE TIME-DELAY CIRCUITS TO PREVENT CYCLING OF LIGHT SHALL CONFORM WITH ALL APPLICABLE CODES. OTHER TRANSITIONS IN CEILING HEIGHT SHALL BE REVIEWED WITH THE <br /> EGRES5 AT FLOOR LEVEL. LEVEL CHANGES OF LESS THAN THREE MINUTES. THE BUILDING IS FULLY SPRINKLERED. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE ARCHITECT PRIOR TO PROCEEDING. CONTRACTOR TO PROVIDE COMPLETE <br /> 3. EACH ROOM SHALL COMPLY WITH THE PROVISIONS OF C405.2 INTERIOR EXCEPTION: DAYLIGHT ZONES ENCLOSED BY WALLS OR CEILING HEIGHT FIRE PROTECTION DRAWINGS AS REQUIRED BY THE GOVERNING AUTHORITY. THE FIRE COORDINATION DRAWINGS FOR THE ARCHITECT AND ENGINEER'S REVIEW. <br /> LIGHTING CONTROLS. EACH AREA ENCLOSED BY WALLS OR FLOOR-TO-CEILING PARTITIONS AND CONTAINING TWO OR FEWER LIGHT FIXTURES ARE NOT PROTECTION CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR REVIEW 5. REWORK EXISTING FIRE, LIFE, SAFETY SYSTEM AS REQUIRED PER NEW WALL <br /> PARTITIONS SHALL HAVE AT LEAST ONE MANUAL CONTROL FOR THE LIGHTING REQUIRED TO HAVE A SEPARATE SWITCH FOR GENERAL AREA LIGHTING. PRIOR TO COMMENCING WITH THE WORK. LAYOUT AND CURRENT CODE. ENGINEERING AND INSTALLATION BY BUILDING <br /> SERVING THAT AREA. THE REQUIRED CONTROLS SHALL BE LOCATED WITHIN THE RECOMMENDED SUB-CONTRACTOR, <br /> AREA SERVED BY THE CONTROLS OR BE A REMOTE SWITCH THAT IDENTIFIES C405.2.1 OCCUPANCY SENSOR5. OCCUPANCY SENSORS SHALL BE INSTALLED IN 6. PROVIDE SMOKE DETECTORS THROUGHOUT TENANT AREAS IN ACCORDANCE <br /> THE LIGHTS SERVED AND INDICATES THEIR STATUS. ALL CLASSROOMS, CONFERENCE/ MEETING ROOMS, EMPLOYEE LUNCH AND WITH LOCAL CODES AND MANUFACTURER'S RECOMMENDATIONS. <br /> BREAK ROOMS. THESE CONTROLS DEVICE5 SHALL BE CAPABLE OF 7. ALL CEILING MOUNTED DEVICES SHALL BE WHITE. <br /> C405.2.2,2 LIGHT REDUCTION CONTROLS. LIGHT REDUCTION CONTROLS NEED AUTOMATICALLY REDUCING THE LIGHTING POWER IN RESPONSE TO AVAILABLE 8. PROVIDE BLOCKING ABOVE CEILING REQUIRED FOR ALL CEILING MOUNTED <br /> NOT BE PROVIDED IN THE FOLLOWING AREAS AND SPACES: DAYLIGHT BY EITHER ONE OF THE FOLLOWING METHODS: EQUIPMENT. PROVIDE ADDITIONAL SUPPORT FOR LIGHT FIXTURES AS <br /> 1. AREAS THAT ARE CONTROLLED BY AN OCCUPANT-SENSING DEVICE. 1. CONTINUOUS DIMMING USING DIMMING BALLASTS AND RECOMMENDED BY FIXTURE MANUFACTURER. <br /> 2. CORRIDORS, EQUIPMENT ROOMS, STOREROOMS, RESTROOMS, PUBLIC DAYLIGHT-SENSING AUTOMATIC CONTROLS THAT ARE CAPABLE OF REDUCING 9. LOCATE ANY CONTROLS THAT NEED ACCESSING OVER ACOUSTICAL CEILING <br /> LOBBIE5, ELECTRICAL OR MECHANICAL ROOMS. THE POWER OF GENERAL LIGHTING IN THE DAYLITE ZONE CONTINUOUSLY TO TILE AREAS. DO NOT PLACE ANY ABOVE GYPSUM BOARD CEILiNGS, UNLESS <br /> 3. DAYLIGHT SPACES COMPLYING WITH SECTION C405.2.2.3.2. LESS THAN 20 PERCENT OF RATED POWER AT MAXIMUM LIGHT OUTPUT. APPROVED BY ARCHITECT. <br /> 10. PROVIDE CEILING ACCESS REQUIRED FOR EQUIPMENT AND SYSTEM <br /> C405.2.2, AUTOMATIC TIME SWITCH CONTROL DEVICES. AUTOMATIC TIME MAINTENANCE. MATCH ADJACENT CEILING FINISH U.N.O. SYSTEMS AND areNr.� <br /> SWITCH CONTROLS NEED NOT BE IN SPACES CONTROLLED BY OCCUPANCY <br /> SENSORS. EQUIPMENT REQUIRING ACCESS SHALL BE LOCATED AT ACCESSIBLE CEILINGS- <br /> ACCES5 PANELS NOT SHOWN ON DRAWINGS SHALL NOT BE INSTALLED IN <br /> GYPSUM BOARD CEILINGS WITHOUT PRIOR APPROVAL. <br /> 11. ALL ACCESS PANELS IN GYPSUM BOARD CEILINGS SHALL BE FRAMELESS; , <br /> LOCATIONS SHALL BE COORDINATED WITH ARCHITECT. GROUP DEVICES TO <br /> MINIMIZE THE NUMBER AND SIZE OF ACCESS PANELS. <br /> 12. ALL CONDUITS, BOXES, DUCTS, HVAC UNITS, PIPES, ETC., SHALL BE INSTALLED <br /> AS HIGH AS POSSIBLE, NOT LOWER THAN 8°ABOVE LINE OF HIGHEST <br /> FINISHED CEILING. <br /> 13. THERE SHALL BE NO COMBUSTIBLE MATERIALS IN THE PLENUM SPACE. <br /> 14. WHEN MULTIPLE SWITCHES OCCUR IN CLOSE PROXIMITY GANG UNDER SINGLE gERTCH CAPITAL <br /> SWITCH PLATE. <br /> 15. FURNISH AND INSTALL NEW THERM05TATS AS REQUIRED. INSTALL CLOSE TO pARTN ERS <br /> DOOR OPENINGS, DO NOT INSTALL IN CENTER OF WALL. ARCHITECT AND <br /> CLIENT TO APPROVE ALL LOCATIONS. $ZIO-164THS AVE NE, SUITE 200 <br /> 16. ALL LIGHTS TO BE CONTROLLED BY MOTION SENSOR. PROVIDE OVERRIDE REDMOND, WASHINGTON 9805z <br /> SWITCH AT ALL CONFERENCE ROOMS <br /> 17. ALL LAMPS SHALL BE IDENTICAL FROM ONE MANUFACTURER IN SAME PROJECT: <br /> TEMPERATURE, uoN. SEAWAY B - <br /> 15. IN EXISTING ALTERED SPACE, REPAIR AND/OR REPLACE COMPONENTS <br /> NECESSARY TO INSURE ALL EXISTING AND OR RELOCATED LIGHT FIXTURES COMPASS/CANTEEN <br /> ARE FUNCTIONING, INCLUDING BUT NOT LIMITED TO LAMPS, BALLASTS,AND <br /> LENSES. RELAMP ALL EXISTING AND RELOCATED FIXTURES TO REMAIN. <br /> CEILING NOTES SEAWAY CENTER - BUILDING B <br /> EVERETT, WA <br /> 1. CENTER CEILING GRID IN ROOM OR AREA IN TWO DIRECTIONS,TYPICAL UON. Description: No: Date: <br /> 2. CENTER LIGHT FIXTURES/SPRINKLER HEAD/CEILING ELEMENT IN 24 PORTION <br /> OF 48" CEILING TILE,TYPICAL UON. PERMIT REVIEW SET 10/25/2019 <br /> WAREHOUSE 3. LOCATE ALL LIGHT FIXTURES, SPEAKERS, LIFE-SAFETY DEVICES AND SIMILAR Q pOST PERMIT REVISION 02/06/2020 <br /> 120 � CEILING ELEMENTS, ETC., IN THE CENTER OF CEILING TILE IN BOTH <br /> DIRECTIONS AND ALIGN WITH ADJACENT FIXTURES, DEVICES OR HEADS IN A <br /> RUN OR ROW, U.N.O. <br /> 4. REFER TO ELEVATIONS AND SECTIONS FOR MOUNTING HEIGHTS OF WALL <br /> SURFACE MOUNTED LIGHT FIXTURES. <br /> 5. PROVIDE SEISMIC BRACING AT ALL SUSPENDED CEILING SYSTEMS. SUSPENDED <br /> CEILING AND BRACING SHALL MEET THE MINIMUM REQUIREMENTS OF CISCA <br /> AND ASCE 7-10 SECTION 13.5.6. AS SUMMARIZED ON SHEET A8.2 <br /> 1 <br /> � TOILET TOILET - TOILET <br /> LEGEND <br /> 110. 121 I22 <br /> 0 INTERNALLY ILLUMINATED EXIT SIGNAGE W/ BATTERY BACKUP <br /> � 0. � EXI QEXIT pER IBC SECTION 1013, CONFIRM OPERATION FOR EXISTING. <br /> � � ADD WHERE NOT EXISTING. ARROW = DIRECTION INDICATOR, , <br /> TOICET IF REQUIRED <br /> 117 118 � � � 105 � 104 103 <br /> 104 � 1X4 SURFACE MOUNTED LED LIGHT FIXTURE W/WRAP AROUND <br /> 0 106 <br /> ACRYLIC LENS <br /> - MONEY ROOM <br /> 111' NEW 2X4 LAY-IN LED LIGHT FIXTURE, 18 CELL PARABOLIC <br /> 0. ` 0 0' C <br /> 119 1 123 I HATCH INDICATES "NIGHT LIGHT" FOR EGRESS ILLUMINATION <br /> � � NOT LESS THAN 1 FC PER IBC SECTION 1008.2.1 WITH SEAL: <br /> � EMERGENCY POWER PER 1008.3.3 <br /> 02 <br /> A8,2 <br /> 3 O� NEW DIRECTIONAL RECESSED LED DOWNLIGHT FIXTURE 10i9d <br /> REC; 'TERED <br /> H►TECT/ <br /> WORK/ I � NEW RECESSED LED DOWNLIGHT FIXTURE ���� <br /> 116 � <br /> �- NEW SURFACE MOUNTED PENDANT LIGHT � EG� LL, <br /> 15 114 1 3 112 108 107 I STATE OF WASI�i1N�TON <br /> , <br /> 6 - I I � EXHAUST FAN (SONE RATING LESS THAN 1.0 SONE) � �� V�R�T� ' <br /> EXI � f�Ei/i�Vt1ED FC3R P�����I� <br /> -- - --- --- - � SUSPENDED ACOUSTIC CEILING TILE AND GRID: <br /> j ARMSTRONG, CORTEGA, 24"X 48" SQUARE LAY-IN TILE, <br /> � � I ""�; � '� `' � � �' ClT�'STAMP: <br /> HITE WITH CLASS A 15/16" EXPOSED "T" GRID SYSTEM, �. ,. s�-�, <br /> � WHITE � �'�� �i �� ':. °,`-- ��iti� G.. <br /> I i EXI ioi i � �} w�� ��i ,� �� � ` <br /> � � <br /> � � <br /> , G PSUM BOARD CEILING �� FE� 13 2�20 �. <br /> --- -- - - - --- t.�;?'Y" QF EVERETT <br /> 1g OPEN TO STRUCTURE <br /> ��rm;� ������^��= <br /> A8.2 <br /> � � <br /> DAYLIGHTZONE REFLECTED CEILING <br /> (PRIMARY DEPTH = TO WINDOW HEAD HEIGHT, 24" BEYOND P�N <br /> WIDTH OF WINDOVIn <br /> (SECONDARY DEPTH = 2 TIMES WINDOW HEAD HEIGHT) <br /> 1 REFLECTED CEILING PLAN Proj. No: 19.0000887.000 Reviewed By: JAKB <br /> A2.Z 1/8"=1'-0" � DIRECTION OF CEILING JOIST FRAMING <br /> �� >,.�, <br /> A2 . 2 <br />