_ ___ ___ � <br /> ABBREVIATIONS � FLOOR PS PAINT SYSTEM SYMBOLS ND WINDOW BUG GENEFiAL NOTES <br /> FLG FLASHING PSF POUNDS PER SQUARE FOOT <br /> � ANGLE FLUOR FLUORESCENT PSI POUNDS PER SQUARE INCH a 1. THE GENERAL CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFEI`( OF ALL <br /> PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANGE WITH O.S.H.A. . <br /> CENTER LINE FM FACTQRY MUTUAL PT PRESSURE TREATED p INTERIOR ELEYATION�S� SAFEfY STANDARDS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INGLUDE REVIEW OF THE AQEQUACY OF L� P A N A_T._T._�_L�I___L� <br /> QS DIAMEfER OR ROUND FOC FACE OF CONCRETE PTD PAPER TOWEL DISPENSER �..-----ELEVATION IDENTIFICATION THE CONTRACTOR'S SAFETY MEASURES. <br /> # NUMBER OR POUND FOF FACE OF FINISH PTD/R PAPER TOWEL DISPENSER �� COLUMN LINE/GRIO LINE 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THEY ARE TO SUBMIT WRITTEN <br /> � PENNY FOIC FURNISH BY OWNER AND RECEPTABLE SHEEf WHERE ELEVATION IS OBJECTIONS PRIQR TO BIDDING, IF THE CONTRACTOR HAS AN OBJECTION TO ANY PRODUCT AND/OR DISCREPANCIES BETWEEN DRAWINGS AND <br /> DRAWN SPECIFlCATIONS. <br /> 1 PERPENDICULAR INSTALL BY CONTRACTOR PTN PARTITION 3. THE GENERAL CONTRACTOR SHALL COORDINATE THEIR WORK WITH THAT OF OTHER SEPARATE CONTRACTS SUCH AS SIGNS, & OWNER FURNISHED <br /> I� PLATE F010 FURNISH BY OWNER PTR PAPER TOWEL RECEPTABLE DOQR NUMBER ITEMS, WHICH ARE BEING DONE BY OTHERS. <br /> INSTALL BY OWNER PVMT PAVEMENT CORRESPONDS TO ROOM ENTERING T�� ROOM IDENTIFICATION 4. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY <br /> AB ANCHOR BOLT FOS FACE OF STUD �T�� ROOM NAME DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK IN THAT AREA SHALL BE HELD UNTIL SUCH <br /> TITLE3 DISCREPANCIES ARE RESOLVED. <br /> AC ACOUSTICAL OR FS FULL SIZE QT QUARRY TILE Rpp� #.�-----�--- ROOM N0. 5. SEPARATE PERMITS, WHEN REQUIRED ANDfOR WHEN WORK ITEMS ARE DESIGN/BUILD IN NATURE, SHALL BE OBTAINED BY THE CONTRACTOR FOR <br /> A/C AIR CONDffIONING Ff FEET X� KEY NOTE MEGHANICAL, PIUMBING, FIRE SPRINKLERS, ELECTRICAL AND FIRE ALARM. DESCRIPTIVE, DETAILED DESIGN AND REQUIRED SUBMITTAL DOCUMENTS <br /> ACP ACOUSTICAL PANEL FfG FO�TING R RISER INFORMATIQN SHALL BE PROVIDED FOR REVIEW 8Y THE REGULATING AUTHORffIES AND BY THE OWNER/TENANT/ARCHITEGT FOR APPROVAL PRIOR TQ a r C h I t@ C t S <br /> ACT ACOUSTICAL TILE FTIC FURNISHED BY TENANT RA REfURN AIR +$'- FINISHED CEILING HEIGHT ANY WORK BEING PERFORMED. SEE SPECIFICATIONS FOR REQUIREMENT FOR DESIGN/BUILD FlRE SPRINKLER SYSTEM. SUBMIT PLAN TO AND OBTAIN <br /> PERMIT FROM THE AUTHOR(fY HAVING JURISDICTION FOR FIRE SPRINKLER SYSTEM INSTALLATION OR MODIFICATION. ALL WORK SHALL COMPLY W1TH <br /> ADH ADHESNE INSTALLED BY CONTRACTOR RAD RADIUS WT PART(TION TYPE CURRENT GOVERNING CODES. 2505 Third Avenue <br /> ADJ ADJACENT FTIO FURNISHED BY TENANT RB RESILIENT BASE - - PROPERTY LINE 6. SPECIAL INSPECTIONS WHERE REQUIRED BY THE BUILDING OFFICIAL SHALL 8E PERFORMED BY INSPECTORS APPROVED BY THE BUILDING OFFICIAL. Suite 324 <br /> ADJT ADJUSTABLE INSTALLED BY OWNER R&S ROD & SHELF X REVISION NUMBER 7. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. TNE APPROVED, PERMITTED, STAMPED Seattle, wA 98�2� <br /> AF ACCESS FLOOR FURR FURRING RD ROOF DRAIN �—REVISION -�''� NEW OR FINISHED CONTOURS PLANS ARE TO REMAIN ON SITE AT ALL TIMES. ANY MODIFICATIONS TO WORK SHALL BE INDICATED ON FIELD "AS-BUILT' SEf OF DOCUMENTS. <br /> AFF ABOVE FINISH FLOQR FUT FUTURE RD/0 ROOF DRAIN OVERFLOW CLOUD AROUND REVISION �a 8. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS OTHERWISE NOTED. 206.720.7001 phone <br /> 9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 206.720.2949 fax <br /> AL ALUMINUM FUTURE- FUTURE ROUGH IN ONLY REBAR REINFORCING BAR --�'" EXISTING CONTQURS 10. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DEfAILS SHALL BE THE SAME AS FOR OTHER SIMILAR <br /> ALT ALTERNATE RIO REF REFERENCE MATCH LINE � — 71 WORK. IF QUESTIONS GAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. <br /> 11. �ENERAL CONTRACTOR SHALL PROVIDE OWNER AND ARCHITECT WITH DETAILED CRITICAL PATH SGHEDULE FOR REVIEW AND APPROYAL PRIOR TO START www.craftarchitects.cam <br /> AP ACCESS PANEL � FIXED REFR REFRIGERATOR _ - SHADED PORTION IS THE SIDE O OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WffH COPIES PROVIDED TO OWNER AND ARCHITECT. <br /> APPROX APPROXIMATE REINF REINFORCED CONSIDERED 1�� 12. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH CURRENT GOVERNING CODES. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED <br /> ARCH ARCHITECTURAL GA GAGE REQ'D REQUIRED '��� TOP OF WALL AS TO PERMIT WORK WHICH IS NOT CONFORMING TO CURRENT GOVERNING CODES. <br /> ASPH ASPHALT GALV GALVANIZED REV REVISION WORK POINT, CONTROL POINT 13. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERIY AT ALL TIMES DURING CONSTRUCTION. <br /> GB GRAB BAR RH RIGHT HAND OR ROBE HOOK �� OR DATUM POINT 16p 14. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICAB�E LOCAL ORDINANCES FOR UTILITY SERVICE PROVIDERS, PUBI.IC AND/OR PRNATE. <br /> BD BOARD GL GLASS OR GIJ\ZING RESIL RESILIENT �G� TOP OF CURB 15. FIRE BLOCKING SHALL BE PROVIDED AT ALL FRAMED WALLS AT 10'-Q" O.C. AND ALSO AT ANY LOCATION WHERE WALL FRAMING PENEfRATES <br /> BETW BETWEEN GLBM GLU-LAM BEAN RM ROOM 1492 EQUIPMENT NUMBER 16. PATCHGAND E EPAIR�ALL EXISTING WALLS, B LOORS AND CEILN GSSTHAT ARE ADJAC NTCTO AND AFFECTED BY NEW CONSTRUCTION. <br /> BLOG BUILDING GEN CONTR GENERAL CONTRACTOR RO ROUGH OPENING 17. PRIOR TO FINAL INSPECTION, A CERTIFICATE OF CONSTRUCTION COMPLIANCE SHALL BE READY FOR THE INSPECTOR. THE CERTIFICATE SHALL STATE <br /> BLK BLOCK GND GROUND RT RESILIENT TILE �5�` TOP OF PAVEMENT "BASED UPON PERSONAL KNOWLEDGE, THAT THE WORK APPEARS TO HAVE BEEN PERFORMED, AND THE MATERIALS USED AND INSTALLED APPEAR IN <br /> BLDG BUILDING GR GRADE RUB RUBBER �UILDING SECTf4N �Q• EVERY MATERIAL RESPECT IN COMPLIANCE WITH THE PLANS". THE CERTIFICATE MUST BE SIGNED BY ONE OR MORE OF THE FOLLOWING: <br /> BM BEAM X (A) OWNER, (B) GENERAL CONTRACTOR, (C) AN APPROVED INDEPENDENT INSPECTOR OR INSPECTION AGENCY. � Q <br /> GWB GYPSUM WALL BOARD RVS REVERSE AX.X SECTION IDENTIFICATION 18. ASBESTOS AND HAZARDOUS WASTE EXCLUSION: � <br /> BRG BEARING RW RAIN WATER � <br /> BOT BOTTOM SHEET WHERE SECTION IS DRAWN THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LIABILI7Y OR OTHER INSURANCE, <br /> BSMT BASEMENT HB HOSE BIB RWL RAIN WATER LEADER PR ECT (AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE) FOR CI.AIMS ARISING OUT OF THE PERFORt�ANCE OF OR THE FAILURE TO PERFORM Q <br /> HC HOLLOW CORE OR HANDICAP NS�TH PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED T0, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND Q O <br /> BUR BUILT UP ROOF HDR HEADER S SOUTH N RELATED TO THE INYESTIGATIQN DEfEGTION. W � � Q <br /> PROJECT NORTH 19. PROVIDE FIRE EXTINGUISHERS WITH A MINIMUM RATING OF 2A:10B:C IN QUANTITY AND LOCATIONS AS DIRECTED BY THE FIRE MARSHALL, MINIMUM OF � � � .�j, <br /> HDWD HARDWOdD SC SOLID CORE DEtAIL SECTION ONE UNIT PER 3,000 SF AND NO MORE THAN 75 FOOT TRAVEL DISTANCE TO ANY FIRE EXTINGUISHER. <br /> CA8 CABINEf HDWE HARDWARE X 20. PROVIDE APPROVED RADIO COVERAGE FOR EMERGENCY RESPONDERS WITHIN THE BUILDING BASED UPON THE EXISTING COVERAGE LEVELS OF THE � Q ^ <br /> SCD SEAT COVER DISPENSER PUBLIC SAFET`( COMMUNICATION SYSTEMS OF THE JURISDICTION AT THE EXTERIOR OF THE BUILDING PER INTERNATIONAL FIRE CODE IFC SECTION � <br /> CB CATCH BASIN qX. SECTION IDENTIFICATION <br /> HM HOLLOW METAL SCHD SCHEDULE �_ � � <br /> CBU CEMENT1Tl0US BACKER UNIT HORIZ HORIZONTAL SHEET WHERE SECTION IS DRAWN g�_� DENOTES CHANGE IN 510.1. <br /> CEM CEMENT SD SOAP DISPENSER OR �_ ELEVATION W � W <br /> HR HOUR SECT SECTION � � /� � <br /> CER CERAMIC HT HEIGHT <br /> CFM CUBIC FEET PER MINUTE �G HEATING SF SQUARE FEEf � W <br /> SHTG SHEATHING r � � � <br /> CFf CONDUCTIVE FLOOR TILE HVAC HEATING ENTILIATION <br /> CG CORNER GUARD � � SIM SIMILIAR 1 DETAIL OR ENLARGED PLAN PT <br /> AIR CONDITIONING SK SINK X FINISH SYI�iBOL a � W <br /> CHBD CHALK BOARD HWH HOT WATER HEATER ,�(.X DEi'AIL IDENTIFICATION 2 � � � <br /> CI CAST IRON SLR SEALER SHEET WHERE DETAIL IS DRAWN � � <br /> SND SANITARY NAPKIN �� <br /> CJT CONTROL JOIM ID INSIDE DIAMETER/ <br /> CLF CHAIN UNK FENCE DISPENSER <br /> DIMENSION SNR SANITARY NAPKIN <br /> ��� CEILING ,� INSULATED GLAZING KEY NOTES� O EGRESS SUMMARY <br /> CJ CONSTRUCTION JOINT RECEPTACLE <br /> IHM INSULATED HOLLOW METAL SNT SEALANT <br /> CLK CAULKING �N INCH t. ACCESSIBLE ENTRANCE/IXIT PER IBC SECTION 1105.1 A. MAX. TRAVEL DISTANCE: 20Q' (TABLE 1017.2 - S-1 OCCUPANCY) <br /> CLO CLOSET SPEC SPECIFICATION 400' EXIT ACCESS DISTANCE INCREASE IBC SECTION 1017.2.2 <br /> INCL INCLUDE SQ SQUARE � � <br /> CLR CLEAR INSUL INSULATION SST STAINLESS STEEL LEGEND B. MAX. COMMON PATH OF EGRESS TRAVEL• 75' (1006.2.1) 100' INCREASE WHEN FULLY SPRINKLED <br /> CMU CONCREfE MASONRY UNIT INT INTERIOR <br /> CNTR COUNTER SSK SERVICE SINK 1 <br /> ST STONE/STONE TILE EXIT NEW EXIT SIGN W/EMERGENCY POWER TO MEET IBC C. REQUIRED EGRESS WIDTH: 0.2" PER OCCUPANT 8.4° REQUIRED (IBC SECTION 10Q5.3) <br /> CO CLEANOUT JAN JANITOR STA STATION SECTION 1013 EGRESS WIDTH PROVIDED = (6) SINGLE DOORS X 3 � PER DOOR = 192" c�$ULTAWT <br /> COL COLUMN JT JOINT EGRESS WIDTH PROVIDED = (2) SINGLE DOQRS X 64 PER DOOR = 128" <br /> CONC CONCREfE STC SOUND 1RANSMISSION FIRE �RE DEPARTMENT ACCESS DQORS PROVIDED AT TOTAL = 320° <br /> CLASS INTERVALS LESS THAN 100' SPACING AROUND PERIMETER <br /> CONSTR CONSTRUCTION KIT KITCHEN OF BUILDING <br /> CONT CONTINUOUS STD STANDARD <br /> KO KNOCK OUT STL STEEL D. MINIMUM CLEAR DOOR OPENING: 32 INCHES (1010.1.1) <br /> CORR CORRIDOR KS KNEE SPACE DIRECTION OF TRAVEL <br /> CPT CARPET STOR STORAGE PATH OF EGRESS E. MAXIMUM DEAD END CORRIDOR: 50 FEEf (1020.4 EXCEPTION 2) <br /> CT CERAMIC TILE STRL STRUCTURAL 1�_ ��„� START POINT <br /> LAM LAMINATE SUSP SUSPENDEO � ♦ <br /> CTR CENTER �qV LAVATORY <br /> CY CUBIC YARD � SHEEf VINYL COMMON PATH OF TRAVEL TERMINATION POINT <br /> LB LAG BOLT SYM SYMMEfRICAL <br /> LF LINEAL FOOT <br /> DBL DOUBLE LG LENGTH T TREAD <br /> DEPT DEPARTMENT � �� Hp�p TB TOWEL BAR <br /> DET DETAIL LINO LINOLEUM T&B TOP & BOTfOM A B C D E F a H J K L M N P p $ <br /> REGISTEREO <br /> 705� <br /> DF DRINKING FOUNTAIN(W/0 COOLER) �R LOCKER TG TEMPERED GLASS , � ; � 9ap�_�;pyE� , � ARCHITECT <br /> DIA DIAMETER LT LIGHT THK THICK 5s�-�' 56'-�' Ss�-o' ' 5s�-o' 56'-d' � 5s�-�' Ss�-o 5s�-o' ' Ss�-d' Ss�-o ss�-d' ; 5s�-�' 5s�-o" �' Ss�-�' ' 5s�-�' i 58�-0' <br /> DIAG DIAGONAL THR THRESHOLD <br /> � �I � I I �� ' � GRAFT <br /> DIM DIMENSION � I <br /> i <br /> TIG TEMPERED INSULATED � i I i i �i I I f AtE <br /> MACH MACHINE � � � OF 'Hn�cro� <br /> DISP DISPENSER MATL MATERIAL GLAZING � FIRE� I - I I. I - - I I I I I I I I I I FIRE � <br /> DN DOWN MAX MAXIMUM TO TOP OF —{- � —� —j— ; - � —1— �- f- --�— -- ---�-- --- __ __ _ 1 <br /> � , � <br /> DR DOOR OR DRAIN MECH MECHANICAL TOC TOP OF CONCRE7E � I , i ; I i <br /> DWR DRAWER TOP TOP OF PAVEMENT EXIT ; � ; FIRE FIRE � , I , EXIT Submittals/Revisions: <br /> MET OR MTL MEfAL , i � I �I i , b <br /> DS DOWNSPOUT MEZZ MEZZANINE TOS TOP OF STEEL � � � � ! <br /> DW DISHWASHER MFR MANUFACTURER TOSL TOP OF SLAB FIRE I � � I � �'I �I� � ; � � FOR PERMIT Q1�26�1 S <br /> � ' T � FIRE ��� � EXIT � FIRE � ! EXIT ����' � � I FIRE <br /> DWG DRAWING MH MANHOLE TOW TOP OF WALL _ � � 0 � FIRE' � FIRE / <br /> -- — fi--- - -- — -- ---- -- -- 2 OPERMIT RESUBMITTAL VE 05 11 18 <br /> MIN MINIMUM TPD TOILET PAPER DISPENSER � ' ' ' -" � � �-- � ` � <br /> E EAST MIR MIRROR TPH TOILET PAPER HOLDER =� ; �! I I � <br /> EA EACH MISC MISCELLANEOUS TP11V TOILEf PARTfi10N ��� � � ; � � � ' � � � �O � � b � <br /> EB IXPANSION BOLT TS TUBUTAR STEEL II °.° ' �c �n ' ; g„ �o � ,��p, <br /> MLD MOLDING � I� i i I � i i I <br /> EJ EXPANSION JOINT N TELEI/ISION � �-- I i � � o I I I � I a � Q I i �� � <br /> MRGWB MOISTURE RESISTANT GYP BD �v_, _ <br /> EL ELEVATION <br /> � , M N � � <br /> MTD MOUNTED TYP TYPICAL -- �— J ---f— - �--- - ------�-- . . � -- - � - ---}- —}--- - --�— -- ----}�-- - t__-- -� - � - - ------ ---�---_ ____ -- 3 <br /> ELEC ELECTRIC MU�L MULLION UL UNDERWRITERS LABORATORY � � � o� a � n N , �1 <br /> E� E�vATOR FIRE � ; � � � � i � ! FIRE � <br /> UNF UNFINISHED � I � � , � � � � <br /> �- I b � <br /> EM ENTRY MAT N NORTH UON UNLESS OTHERWISE NOTED � � I, ; � I � � � I ; � � <br /> �, EMER EMERGENCY NIC NOT IN CONTRACT UR URINAL ; �� � � � � � � � �, � ��� � � � ; �� � <br /> � ENCL ENCLOSURE OR ENCL4SED NO NUMBER �-_ � � � ' ' <br /> � <br /> --- - I � � � ' ' i i N <br /> J � � � I <br /> - — - �-���_�� �� -- �- - _�-_� _-- --- - - __ _ 4 <br /> ,� _ _� .�. _ _ _ . ��_ _ _ __ _ _ _ �. _ _ _ _ <br /> a EP ELECTRICAL PANEL NOM NOMINAL VAR VARIES � ' I I I I i ! I I � ' <br /> a I <br /> W EWC ELECTRIC WATER COOLER NTS NOT TO SCALE VCT VINYL COMPOSITION TILE I I j � I, ' Q I ' I I � Sheet Title: GENERAL INFORMATION <br /> w EPX EPDXY OA OVERALL VERT VERTICAL 'fn � � I � ^ `�n ` i, �, � <br /> � EQ EQUAL VEST VESTIBULE � � , � � j j �n �n I I !; N, <br /> o OC ON CENTER i N � � I rn c� <br /> Z EQPT EQUIPMENT OD OUTSIDE DIAMETER VIN VINYL FIRE - -�_�'___,;- - �— __ � _._ � N N �,_ � �_ �_ � � N _ _ _; �, AND EGRESS PLAN <br /> I FIRE <br /> � - — -- — — — --- — <br /> - - - -- - _ _. 5 <br /> . , +----- -- --�----- - �. --- <br /> a EST ESTIMATE � n N N � n i ( Date: <br /> W DIMENSION �C VINYL WALL COVERING ( a I I I , o I o I I I I � I I o ' o I ! I I o ' O1�Z4�18 <br /> z D( IXPANSION <br /> ; OFF OFFICE W W� �' i � I �' �' � � I w W ' � '� Design: <br /> EXT EXTER OR OH OVERHEAD � I � ; � ' � I I, I '� I '4� � I � TES <br /> ~' OPH OPPOSITE HAND W/0 WITHOUT � ; � 'I I I I � � <br /> WC WATER CLOSET -- -- ----- -- - - -__ _ - -- ----- -- --. - _-_ _ -- - - ------ -- - -I — ---- --- --�- D ra w n: JW+TES <br /> ° OPNG OPENING ' � I � I <br /> � FA FIRE ALARM oPP OPPOSITE Wo w000 FIRE FIRE � FIRE FIRE F 6 Pro'ect No: <br /> _ �o FURNISHED BY OTHERS EXIT � 0 EXIT � FIRE FIRE � EXIT t FIRE IRE EXIT � J 17-109 <br /> ° WF WIDE FLANGE <br /> `� FCIC FURNISHED BY CONTRACTOR � � � <br /> = PERP PERPENDICULAR WG WIRE GLASS Approved: KCR <br /> �' <br /> o INSTALLED BY CONTRACTOR PFN PREFINISHED WP WATER PROOF <br /> r FC1Y FACTORY PL PLATE OR PROPERTY LINE WR WATER RESISTANT Building No: <br /> � <br /> FD FLOOR DRAIN P LAM PL.ASTIC LAMINATE WSCT WAINSCOT <br /> a FDN FOUNDATION PLYWD PLYINOOD WT WEIGHT FIRST FLODR EGRESS PLAN <br /> � <br /> FE FlRE EXTINGUISNER PNL PANEL XFMR TRANSFORMER N � Sheet No: <br /> � . <br /> a FEC FIRE EXTINGUISHER CABINET pNT PAINT 1" = 50'-0" <br /> o FIN FINISH PR PAIR YD YARD <br /> COPYRIGHT CRAFT ARCHITECTS 2017 <br />