|
�
<br /> � �
<br /> � } -�
<br /> GENERAL FINISH PLAN NOTES: �'
<br /> � � a�
<br /> FINISH PLAN LEGEND � � � �
<br /> --� 1. ALL CARPET INSTALLED IN THE BUILDING INTERIOR MUST MEET THE TESTWG AND PRODUCT :F- � p
<br /> Room Name ! REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PLUS PROGRAM. U '� •� �
<br /> ROOM NAME 2. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR MUST MEET THE Q w w �
<br /> 101 ROOM NUMBER REQUIREMENTS OF THE CARPETAND RUG INSTITUTE GREEN LABEL PROGRAM.
<br /> 3. A L L CARP E T A DH E SIV E S M U S T H A V E L E S S T H A N 5 0 g/L V O C. N �
<br /> 4. ALL HARD SURFACE FLOORING MUST BE CERTIF►ED AS COMPLAINT WITH THE FLOORSCORE N
<br /> �� STANDARD BY AN INDEPENDENT THIRD-PARTY.FLOORING PRODUCTS COVERED BY ��
<br /> • v WALL FINISH � FLOORSCORE INCLUDE VINYL,LINOI.EUM,LAMINATE FLOORING,WOOD FLOORING,CERAMIC �
<br /> � FLOOR BASE ',Z FLOORING,RUBBER FLOORING AND WALL BASE. �
<br /> � FLOOR FINISH � FINISH TAG 5. COMPOSITE WOOD AND AGRIFIBER PRODUCTS MUST CONTAIN NO ADDED UREA- U
<br /> � WALL FINISH � FORMALDEHYDE RESINS.LAMINATE ADHESIVES USEd TO FABRICATE ON-SITE AND SHOP-
<br /> APPLIED COMPOSITE WOOD AND AGRIFIBER ASSEMBLIES MUST NOT CONTAIN ADDED UREA-
<br /> �� FORMALDEHYDE RESINS, -- , �-- - -- � -- � ---
<br /> 6. ALL PAINTS,ADHESIVES,PRIMERS AND OTHER COATINGS TO BE LOW OR ZERO VOCS.
<br /> NOTES: 7. ALL INTERIOR FINISHES SHALL COMPLY WITH IBC SECTION 803.5"INTERIOR WALL AND 355 Research Parkway
<br /> CEILING FINISH REQUIREMENTS BY OCCUPANCY." Meriden,CT 06450
<br /> �. SEE SCHEDULE FOR WAREHOUSE FINISHES. 8. INSTAL�SUSPENDED ACOUSTIC CEILING SYSTEM IN CONFORMANCE WITH IBC SECTION 803.9 (203) 630-1406
<br /> 2. SEE TOILET ROOM PLANS FOR ADDITIONAL "ACOUSTICAL CEIUNG SYSTEMS°(ASTM C635&C3636). (203� 630-2615 Fax
<br /> CORNER GUARD LOCATIONS. 9 NOT ALL MATERIALS LISTED IN THE"MATERIAL FINISH KEY"MAY BE USED ON THIS
<br /> PT_$ PRO,lECT.COORDINATE WITH PLANS&DETAILS. "" '
<br /> � cr-a �
<br /> 3. SEE A1.01 FOR KEYNOTES
<br /> � cr-s � 4. SEE A4.01 FOR WALL MOUNTED
<br /> • 639I PT-8 ACCESSORIES SPECIFIC FINISH PLAN NOTES:
<br /> � 0 1. JOINT SEALANT AT SEALED CONCRETE TO BE STANDARD LIGHT GRP,Y COLOR. � 12154 REGIST RED
<br /> 2. PROVIDE WINDOW BLINDS HB-1 AT ALL EXTERIOR WINDOW LOCATIONS NOTED.DO NOT ARCHI ECT
<br /> I I - PROVIDE HORIZONTAL BLINDS AT DOOR LITES.
<br /> 605 3. "CG"AND"EG"REFER TO CORNER GUARDS AND END GUARDS TO BE PROVIDED.ALL �,.,,
<br /> OUTSIDE CORNERS OF GWB PARTITIONS TO BE PROVIDED WITH A CORNER GUARD.FOR RBARA J. JOSLIN
<br /> 605 WOMEN MORE INFO SEE DETAIL 5/A10.01 FOR MORE INFO. STF,TE OF WASHINGTON
<br /> BREAK ROOM 303 a
<br /> 639 302
<br /> 604 ' C�' KEY NOTES
<br /> ,s�a � � � i
<br /> 631 C. I # DESCRIPTION
<br /> 298 PROVIDE WINDOW FILM(WF-1}TO INTERIOR SIDE OF EXiSTING
<br /> ' :- � STOREFRONT/WINDOW. (SEE MATERIAL KEY ON SHEET A10.01 OR _
<br /> C_
<br /> _ __
<br /> 634 SPECIFICATI ONS).
<br /> Pr-�4 604 I '� � 604 STAINLESS STEEL 2°x2"x48"H CORNER GUARD AT ALL EXPOSED OUTSIDE
<br /> � v&3 � 639 �CORNERS OF G.W.B.SEE DETAIL 5/10.01
<br /> a sc� � - ---
<br /> Pr-�4 � . MEN i 605 2"WWG x THICKNESS OF WALL x 48"H END CAP GUARD AT ALL EXPOSED
<br /> 304 a � CORNERS OF G.W.B. CONTRACTOR TO VERIFY SIZE BEFORE ORDERING AND
<br /> 605 PT$ I j INSTALLING. SEE DETAIL 5/10.01
<br /> � 605 �T� 608 1/2"ENTRY MATT-SEE FINISH SCHEDULE
<br /> � �
<br /> I I � CT-3 °- 631 PROVIDE FRP-1 PANELS TO 4'-0"AFF ON INSIDE OF DRINKING FOUNTAIN ALCOVE. (
<br /> Pr-a
<br /> 604 __ ___ __ 634 EXTENT OF WALL TILE(5EE DETAILS 1,3&4 ON A10.01).
<br /> — --
<br /> 637 INSTALL FRP-1 PANELS UP TO 8'-0"HIGH ON ALL PARTITIONS IN THIS ROOM. SEE
<br /> 2 FINISH MATERIAL KEY
<br /> �638 PROVIDE FRP-1 PANELS UNDER PLAM COUNTER. SEE INTERIOR ELEVATIONS � O
<br /> • F AND FINISH MATERIAL KEY �
<br /> ;639 PAINT WAREHOUSE SIDE OF ALL PARTITION WALLS PT-8 UP T015'-0°AFF. r—
<br /> INSTALL VINYL BASE VB-3 ON GWB PARTITION WALLS.SEE FINISH MATERIAL KEY � W
<br /> 640 PROVIDE 3l4"FR.T.P�YWOOD BACKBOARD UP TO 8'-0"AFF AT WALLS WITH I �— �--
<br /> ELECTRIGAL EQUIPMENT. PLYWOQD SHALL BE PAINTED WITH(2)COATS OF FIRE I � — '—
<br /> R E M OTE O F F I C E F I N I S H P LA N RESISTANT PRIMER AND(2}COATS FIRE RESISTANT PAINT PAINT TO MATCH W � O
<br /> _� 2 � �/H�� - �'-O�� GWB PAINTED SUREFACE � Q �
<br /> W �
<br /> / O Q
<br /> A � H W � �
<br /> � w �
<br /> PT-8 PT-8 '� Q w
<br /> w CT-4 m �o VB-3 m � � �
<br /> • 639 � CT-3 � � EPX-1 °� i � � W
<br /> PT-8 PT-8 I i /� W �
<br /> g - - - - , - ,, - --__ - - - - �� - - � > w
<br /> � � � _
<br /> ,�� � ,
<br /> � �' � � , CL
<br /> t~ ,
<br /> 639 �''�'=° Pr-� 298 � 08 � �
<br /> WOMEN MEN JANITOR STORAGE � v�-3 � PT-8 ENTRY � C� ' � -_ �� - - - - , , � �..� � �
<br /> 605€ 406 405 605 404 403 � PT-1 � � VB 3 � 101 T? � I �� �
<br /> sc-� �
<br /> Pr-s � 637 Pr-a i I � �,_�"` <_ , 638
<br /> � CT-4 «� — — � � ' � � �
<br /> °' CT.3 °- 6� 6� � �i o - - - I
<br /> , �� _a.rv`
<br /> PT-8 i � �,
<br /> �� !
<br /> - ° �Q � - - -- ,
<br /> — - O — - —�—-- !
<br /> — — PT-a i j � � � �
<br /> � ve-3 � SECURITY -
<br /> � � � � - - -
<br /> - - - - - - - - = - - - -
<br /> _ .
<br /> 605 605 604 631 604 605 sc-� 102
<br /> PT-8 605 � BREAK ROOM
<br /> 639 � � — - — — — , �03
<br /> ;�
<br /> -- �
<br /> F __„ PT-14
<br /> BREAK ROOM � 604 �` v6-3 �
<br /> _ �� 402 _,�; � SC-t �
<br /> II 605 _; - - -- - - — -_- PT-�s
<br /> i�� _
<br /> PT-14 � � �
<br /> a V&3 � � - � (- i- -j- -� - -
<br /> � 5�.� � u I
<br /> PT-14 � � I ___i � Z '
<br /> . .
<br /> '� _`;
<br /> - - - - �
<br /> - - -- - - -
<br /> __: �-
<br /> _ �
<br /> � 605 604 - - -� -- �- __ �, _! l_ _ _, �
<br /> U
<br /> 639 639 ' - - - - - - - Z o
<br /> +- i � i p
<br /> L - 6Q4 �,
<br /> � AMXL �
<br /> ; � w
<br /> �I 401 i i �
<br /> - - - - - - - - �
<br /> � PT-1 639
<br /> +�- � V&1 � ;ri�� zz�. PT-2
<br /> �
<br /> � � � CPT-1 � � �.4�$ CO/� � VB-1 � � �.
<br /> � �r� , ,
<br /> U Pr-3 �CONFERENCE. � �PT-�- � w
<br /> _ � �i :� 1�6 F'� PT-1 Q
<br /> � ..
<br /> � � >.-
<br /> U __ � � _ ._ — �
<br /> � ,,: , o 0
<br /> „ �,
<br /> . � __f �i —_ —
<br /> t Jq '
<br /> Q ......'6 . ��� ...... � .
<br /> �' �r �..
<br /> � 639 ❑ � � /� ❑ �
<br /> �
<br /> � 634 634 � _/
<br /> O
<br /> O i MANAGER � i - � _
<br /> O�
<br /> r \ OFFICE Designed DM
<br /> 5 - -- - - - - - - - - -� -
<br /> N J MANAGER \__ - --- - 105- - — , � - � � C Drawn: JF
<br /> _ \ - - -
<br /> } i PT-� OFFICE -� \ i Reviewed: JJ
<br /> � OFFICE �� v��
<br /> � i 639 604 / 407 ` cPr-� ° 107 � WOMEN �� �--� MEN � Scale: As indicated
<br /> � PT-t
<br /> � EMERGENCY � � : � 111 � � 112 Project No. 1900494
<br /> ELECTRICAL 1
<br /> � '� �T-� ,� � 604 � �, �� � �' 604 Date: 04/19/2019 �
<br /> Q / 204� � v&1 !� JANITOR( \_� NEW MOTHER'S/ -=
<br /> � , �� � CPT-1 �� � STORAGE COORIDOR FIRST AID
<br /> . � � - pr-� ---: Pr_� I 605 ,� __ vEST. 605 "
<br /> �
<br /> � _ -� 108 104 109 �
<br /> / 640 �-- � sc-� � ��o _ _
<br /> - ,_
<br /> , �,�
<br /> � � � o � I I' �63� � II rtle: -_ . _ - -
<br /> N (� PT-1
<br /> � L� � - - - — � — FINISHES PLANS AND
<br /> / 639 � � � ---� � � �
<br /> � 604 639� � �604 604 604 D ETAI LS
<br /> � � I PT-8 PT-1 PT-14 ! PT-8 PT-B PT-8
<br /> � 639 604 � ^ � � � �
<br /> � � � VB-3 � � VB-3 � � V&i i? �, CT� � CT-4 CT 4
<br /> Q ' � EXP-1 � � SC-t � a� CPT-1 a � CT-3 � � CT-3 � � CT-3 �
<br /> ----
<br /> PT-S PT-1 i PT-14 PT-8 PT-8 PT-8
<br /> _.. _._...
<br /> � ELECTRICAL ROOM
<br /> �
<br /> ee No.
<br /> � 4 FINISH PLAN 2 REMOTE CJFFICE FINISH PLAN � � SUPPORT AREA FINISH PLAN
<br /> " � � 1/8" = 1'-0" _ � 1/8" = 1'-0" �� /� 1/8" = 1'-0" 1
<br /> O = �Vd�:�� I � � 1 O . O�
<br /> o� _ _.F _
<br /> �
<br /> �
<br /> OO 2017 BL COMPANIES,INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON,FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITfEN PERMISSION OF BL COMPANIES.
<br />
|