Laserfiche WebLink
��� .. <br /> � <br /> FIXTURE SCHEDULE � �� <br /> � � � � <br /> � .� � � <br /> i � <br /> �"'- �� ELONGAT DSBOWL DESIGN SIPHON JETOFNUSOHING WIOTHED1l2�TOP PUDEMODE OTRI OINT K1109 6ASV�HYBR D ELECTRON C FLUSH � � � N <br /> PLUMBING LEGEND PLUMBING GENERAL NOTES L <br /> VALVE, 1" I.P.S., SCREWDRIVER BAK-CHEGK ANG�E STOP WITH PROTECTION CAP, RUBBER BUMPER ON STOP,ADJUSTABLE TAILPIECE, U �� �> � <br /> VACUUM BREAKER FLUSH CONNECTION AND SPUD COUPLING FOR 1-1l2°TOP SPUD, WALL AND SPUD FLANGES. K-473-C WHITE, Q w w � ' <br /> ELONGATED, OPEN FRONT SEAT WITH CHECK HWGE. FURNISH WITH WATTS HORIZONTAL,ADJUSTABLE CARRIER(OR APPROVED EQUA�). SYMBOL ABBREVIATION DESCRIPTION 1. GENERAL NOTES, SYMBO�S LIST AND DETAILS ARE APPLICABLE TO ALL DRAWINGS MARKED <br /> � U1 URINAL-KOHLER K-4991-ET"BARDON°(OR APPROVED EQUAL)WHITE VITREOUS CHINA, 0.125 GALLON PER FLUSH,HIGH EFFICIENCY URINAL. P � <br /> �.. WALL HUNG, WASHOUT DESIGN, ELONGATED RIM, 3/4"TOP SPUD INLET, 2" I.P.S. OUTLET, WALL HANGERS AND BEEHIVE STRAINER,K-7546 SAN OR W SOIL OR WASTE ABOVE FLOOR OR GRADE 2. DRAWINGS ARE DIAGRAMMATIC: DETERMINE LOCATIONS OF SYSTEMS AND COMPONENTS IN �� , <br /> HYBRID HES ELECTRONIC FLUSH VALVE, EXPOSED DIAPHRAGM TYPE, CHROME PLATED, 314" I.P.S. SCREWQRIVER BAK-CHECK ANGLE STOP FIELD. � <br /> WITH PROTECTIVE CAP,ADJUSTABLE TAILPIECE, VACUUM BREAKER FLUSH CONNECTION SPUD COUPLING FOR 3/4"TOP SPUD � � SAN OR W SOIL OR WASTE BELOW FLOOR OR GRADE � : <br /> CONNECTIONS. FURNISH WITH WATTS ADJUSTABLE CARRIER(OR APPROVED EQUAL). 3. WORK OF THIS SECTION IS SPECIFIED BELOW. 0 . <br /> � L1 AMERICAN STANDARD MODEL 0497.300"OVALYN", 21-1/2"x 15-3/8"x 5-1/2" DEEP, VITREOUS CHINA FRONT OVERF�OW, GLAZED CW COLD WATER PIPING 4. NEITHER ACCURACY NOR COMPLETION OF UTILITY LOCATIONS SHOWN ON DRAWINGS IS U <br /> �' UNDERSIDE, COLOR SHALL BE WHITE, COMPLETE WITH MOUNTING KIT AND TEMPLATE. SUPPLY FITfING:AMERICAN STANDARD - GUARANTEED. DETERMINE EXACT LOCATIONS OF EXISTING UTILITY IN FIELD, WHETHER OR ,���,��„��, � <br /> MODEL 6053.105-V035, 0.35 GPM MULTI-LAMINAR SPRAY, BATTERY OPERATED SENSOR ACTIVATED FAUCET WITH 605XTMV1070 _ _ HW HOT WATER PIPING NOT SHOWN ON DRAWINGS. EXERCISE CAUTION RND IDENTIFY LOCATIONS OF UNMARKED <br /> THERMOSTATIC MIXING VALVE. GRID DRAIN ASSEMBI�Y. PROVIDE 1/2"x 3/8"ANGLE STOPS, WITH FLEXIBLE TUBE RISERS. PROVIDE UTILITY LINES AS NECESSARY TO PERFORM WORK OF THIS SECTION. 355 Research Parkway <br /> OFFSET P TRAP FOR HANDICAPPED ACCESS. INSULATE AL� EXPOSED WATER AND WASTE PIPING BELOW COUNTER WITH TRUEBRO Meriden,CT 06450 <br /> INSULATION KIT, MODEL 102 E-Z. - - - HWR HOT WATER RECIRC PIPING 5. ALL PLUMBING WORK SHALL BE IN COMPLIANCE WITH THE CURRENT WASHINGTON STATE (203} 630-1406 <br /> PLUMBING CODE (203) 630-2615 Fax , <br /> � SK1 SINK-ELKAY MODEL LRAD2219553 (OR APPROVED EQUAL) 18 GA STAINLESS STEEL SINGLE COMPARTMENT TOP MOUNT SINK WITH G G GAS PIPING <br /> `, 6. IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE HIS WORK WITH �F"`���"`"'�" <br /> DRAIN ASSEMBLIES,AND MAINTENANCE KIT. 3-HOLE DECK PENETRATIONS, TAILPIECES, P-TRAPS AND SUPPLIES. ELKAY LK1000CR THAT OF ALL OTHER TRADES, INCLUDING (BUT NOT LIMITED TO), ELECTRICAL, HVAC PROCESS <br /> FAUCET, 1.5 GPM, TRUEBRO LAVGUARD 2E-Z PIPE COVERING. ---------------- V VENT PIPING PIPING, SPRINKLER, PLUMBING, STRUCTURAL,AND GENERAL ARCHITECTURE. <br /> � SK2 SINK-ELKAY MODE� ELUHAD311845 (OR APPROVED EQUAL) 18GA STAINLESS STEEL DOUBLE COMPARTMENT TOP MOUNT SWK C CONDENSATE PIPING �tt`� �18 <br /> �" WITH DRAIN ASSEMBLIES AND MAINTENANCE KIT. 3-HOLE DECK PENETRATIONS, TAILPIECES, P-TRAPS AND SUPPLIES �K1000CR C 7. ANY INTERFERENCE SHALL BE BR�UGHT TO THE ATTENTION OF THE CONSTRUCTION ��S WAS �� ` <br /> FAUCET, 1.5 GPM. MANAGER AND THE OWNER'S REPRESENTATIVE,AfVD SHALL BE RESOLVED PRIOR TO THE ��°F ., �U,�,c <br /> -�FCO FCO FLOOR CLEANOUT INSTALLATIQN OF THE WORK INVOLVED. yt � �o� <br /> SS1 MOP RECEPTOR-FIAT MODEL MSB2424(OR APPROVED EQUAL) MOLDED STONE MOP SERVICE BASIN. 24"X 24"WITH 3"QUICK DRAW gV BALL VALVE 8. NO WORK SHALL BE INSTALLED W VIOLATION OF ANY GOVERNING CODES. ANY WORK � �,. <br /> CONNECTOR, 830-AA FAUCET WITH VACUUM BREAKER, MOP HANGER AND SILICONE SEALANT. � SHOWN ON THE DRAWINGS WHICH IS IN VIOLATION OF SUCH CODES SHALL BE BROUGHT TO �, 57 � <br /> THE ATTENTION OF THE CONSTRUCTION MANAGER AND THE OWNER'S REPRESENTATIVE AND � �cr � k' <br /> � EWC ELECTRIC WATER COOLER- HALSEY TAYLOR(OR APPROVED EQUAL} MODE� HTVZ8BLSS-NF BI-LEVEL BARRIER FREE WATER COOLER I��J�/H HB WH, HB EXTERIOR WALL HYDRANT OR INTERIOR HOSE BIBB SHALL BE RESOLVED PRIOR TO THE INSTALLATION OF THE WORK INVOLVED. s t jyA ��� � <br /> WITH EASY TOUCH PUSHBAR ACTIVATION. ' <br /> SD1 SCRUBBER DRAIN -JAY R. SMITH 8811-20 OR APPROVED EQUAL GRAY DUCO COATED STEEL 2'x2' CATCH BASIN WITH LOOSE � POINT OF NEW GONNECTION 9. ALL PIPING PENETRATING CEILING AND WALLS SHALL BE INSTALLED WITH CHROME ,r • � <br /> SET HEAVY DUTY CAST IRON GRATE AND 4" NO-HUB OUTLET 26" DEEP SUMP WITH INTERNAL BAFFLE. (STAINLESS WHERE NOTED) PLATED ESCUTCHEONS AT THE PENETRATION.ALL PIPING ," <br /> � PENETRATING EXTERIOR WALLS AND ROOFS SHALL BE FLASHED IN AN APPROVED MANNER <br /> POINT OF DISCONNECT AND SHALL BE SEA�ED WEATHER TIGHT. PIPING PENETRATING RATED PARTITIONS SHALL BE <br /> __ PROTECTED AS REQUIRED BY LOCAL CODE AUTHORITY(SEE DETAILS). <br /> FD1 FLOOR DRAIN -WATTS MODEL FD-100-A OR APPROVED EQUAL EPDXY COATED CAST IRON FLOOR DRAIN WITH ANCHOR FLANGE HC HANDICAPPED ACCESSIBLE FIXTURE OR DEVICE � ���WE�,��F�����rwN <br /> REVERSABLE CLAMPING COLLAR WITH PRIMARY&SECONDARY WEEPHOLES,ADJUSTABLE 5"DIA HEEL PROOF NICKE� BRONZE `, 10. MANUFACTURER'S MODE�NUMBERS ARE SPECIFIED SOLELY TO ESTABLISH STANDARDS OF - <br /> STRAINER AND NO-HUB CONNECTION. -- - --- QUALITY FOR PERFORMANCE AND MATERIALS. <br /> INV. INVERT ELEVATION <br /> - 11. PRODUCTION INSTALL4TION SHALL ADHERE TO MANUFACTURERS' RECOMMENDATIONS. <br /> FS1 FLOOR SINK-WATTS MODEL FS-500 OR APPROVED EQUAL 12" SQUARE X 6" DEEP, PVC SANITARY FLOOR SINK WITH SECURED VTR VENT THRU ROOF <br /> 1/2 GRATE, DOME BOTTOM STRAINER AND NO-HUB CONNECTION. 12. PROVIDE ACCESS PANELS FOR EQUIPMENT THAT REQUIRES PERIODIC SERVICE. <br /> HB1 HOSE BIBB LOOSE KEY-WOODFORD#24P-3/4"WITH LOOSE TEE KEY AND VACUUM BREAKER HOSE BIBB, CHROME PCATED. ACB ABOVE CEILING BELOW 13. TOPS OF ALL FLOOR DRAINS SHALL BE SET FLUSH WITH FINISHED FLOOR.ALL PIPING ABOVE <br /> _ _ __ __ __________ _ GRADE SHALL BE PROPERLY SUPPORTED BY THE BUILDING STRUCTURE AND SHA�L NOT , <br /> HB2 HOSE BIBB LOOSE KEY-WOODFORD#45-VB-PC-3/4"WITH LOOSE TEE KEY AND VACUUM BREAKER HOSE BIBB, CHROME PLATED. AAV AIR ADMITTANCE VALVE REST ON CEILING TILES OR CEILING STRUCTURE. <br /> DF1 FREE STANQING POINT OF USE WATER COOLER PROVIDED AND SET IN PIACE BY OWNER. PROVIDE 1J2"CW SUPPLY WITH 3/8" - ---- - ------ -- - 14. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF <br /> QUICK DISCONNECT AND SHUT-OFF VALVE 24'AFF. FD FLOOR DRAIN ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND SHALL FURNISH <br /> EQUIPMENT WIRED FOR THE VOLTAGES SHOWN HEREIN. 0 <br /> WH1 WATER HEATER- HTP MODEL EVC040 40 GALLON ELECTRIC WATER HEATER WITH STAINLESS STEEL TANK, DUAL 4000 WATT � <br /> ELEMENTS AT 208V, 3PH. SIMULTANEOUS OPERATION. WATTS MODEL LF1170 THERMOSTATIC MIXING VALVE SET @ 110DEG. VTR VENT THROUGH ROOF ,_ <br /> 15. PROVIDE SHUTOFF VALVES ON ALL BRANCH PIPING AND ON AL� SUPPLIES TO INDIVIDUAL <br /> WH2 INSTANTRNEOUS WATER HEATER- E�MAX-SAFEADVANTAGE- MODEL AP072480-EFD-N4 FIXTURES AND EQUIPMENT. PROVIDE BALL VALVES ON ALL WATER MAIN BRANCHES IN W <br /> WALL MOUNTED TEPID WATER HEATER.480V. 3PH, 96KW. 87 AMPS, 21°TEMP RISE 23 GPM Zp TP TRAP PRIMER � I- <br /> @ ACCESSIBLE LOCATIONS AND WHERE INDICATED ON DRAWINGS.ALL VALVES SHAL� BE - r- <br /> RP1 RECIRCULATING PUMP-ARMSTRONG MODEL 225 BS LEAD FREE BRONZE, 115V, 1 PH, .69 FULL AMPS. 3 GPM @ 6'HD.ARMSTRONG ACCESSBLE. W � O <br /> MODEL 3.0, 24 HOUR TIMER AND AQUASTAT UNIT, 120V. 16. ALL SLEEVES THROUGH CONCRETE FLOORS AND ALL CORE DRILLING OF CONCRETE FLOORS <br /> RP1 IS LOCATED IN JANITOR ROOM. AND WALLS SHALL BE BY THIS CONTRACTOR. W � � <br /> �ES/EW HAWS MODEL 8309WC BARRIER-FREE COMBINATION SHOWER AND EYE/FACE WASH SHALL INCLUDE A STAINLESS STEEL 11" ROUND \ Q � <br /> �" BOWL,AN AXION MSR EYEIFACE WASH HEAD SHALL FEATURE INVERTED DIRECTIONAL LAMINAR FLOW SUPPLIED BY AN INTEGRAL 3.7 17. CONCRETE PADS AND PLATFORMS FOR WORK OF THIS SECTION WILL BE PROVIDED BY � . <br /> GPM FLOW GONTROL. UNIT SHALL ALSO INCLUDE THE AXION MSR ABS PLASTIC SHOWERHEAD WITH 20 GPM F�OW CONTROL, GENERAL CONTRACTOR. PROVIDE INFORMATION AND HARDWARE AS NECESSARY TO W O � <br /> CHROME-PLATED BRASS STAY-OPEN BALL VALVE EQUIPPED WITH STAINLESS STEEL BALL AND STEM,AND CHROME-PLATED BRASS COORDINATE WORK. <br /> FITf NGS POWDER-COA ED CAST IRON 9'NDI MH TER FLOOR FLLANGECSELDFUADHESIVOE �I'GH VISIBIL TY SAFETY GREEN AND BRIGHT DOMESTIC WATER CALCU LATIONS 18. SCHEDULE WORK OF THIS SECTION TO AVOID INTERFERENCE WITH FIRE-PROOFING WORK � Q F- � <br /> YELLOW STRIPES, UNIVERSAL SIGN,AND 1-1/4�� rvPT suPP�Y. (PREDOMINANTLY FOR A FLUSH VALVE TYPE SYSTEM) - W <br /> cn � <br /> SE1 SEWAGE EJECTOR- (2) HYDROMATIC MODELS HPGFH500M4 DUAL SEAL SUBMERSIBLE GRINDER PUMPS RATED FOR 60 GPM @ 40' 19. COORDINATE ROOF PENETRATIONS WITH WORK OF OTHER SECTIONS AND WITH FLASHING � W <br /> TDH WHEN OPERATED BYA 5HP, 1750RPM 460V, 3PH SUBMERSIBLE MOTORS. 3600 RPM PUMPS WILL NOT BE CONSIDERED EQUAL. PRO�ECT NAME: PRO.JECT SWA') <br /> PROJECT NUMBER: 1900494 REQUIREMENTS. � w � <br /> 60" DIAMETER x 10'-0" DEEP FIBERGLASS BASIN W!ANTI-FLOTATION RING. IN THE EVENT HIGH WATER IS ENCOUNTERED,A � � W <br /> CONCRETE HOLD DOWN PAD TIED INTO ANTI-FLOTAfON RWG. PRO.IECT ADDRESS: EVERETT, WA 20. RUN PIPING CONCEALED, UNLESS SPECIFIED OTHERWISE,AND CLEAR OF CEILING INSERTS. (� <br /> 21. STRUCTURAL WELDING IF REQUIRED REFER TO STRUCTURAL DRAWING. � <br /> DEMAND WEIGHT OF FIXTURES IN FIXTURE UNITS � <br /> 22. PROVIDE C�AMPS, OFFSETS, EXPANSION JOINTS,ANCHORS AND GUIDES AS NECESSARY TO � <br /> FIXTURE UNITS MIN. CONNECTIONS NO. OF TOTAL " PREVENT STRESS ON PIPING. " <br /> FIXTURE TYPE PRIVATE PUBLIC= CW HW FIXT. F.U. <br /> 23. PROVIDE BALANCING VALVES AT SYSTEM LOOP RETURNS AND AT RETURN RISERS. PROVIDE <br /> SHUT-0FF VALVES AT SYSTEM LOOP SUPPLIES AND SUPPLY RISERS. <br /> V1/ATER CLOSET: - 10 ` 1" - 12 120 <br /> 24. PROVIDE VENTS AT HIGH POINTS IN PIPING SYSTEMS AND DRAIN VALVES AT LOW POINTS. <br /> FIXTURE CONNECTfON SCHEDULE � LAVATORY - 2 1/2�� ��2�� s �� <br /> 25. PROVIDE GAUGE FITTINGS AND THERMOMETER WE�LS AT HOT WATER SUPPLY AND RETURN <br /> � � MINIMUM SIZE UTILITY FIXTURE URINAL (WALL) - 5 3l4" - 4 1 Q BRarvcHEs. <br /> I WASTE DRAINAGE � HOT WATER HOT WATER COLD WATER MOP BASIN - 3 1 JZ�� 1/2�� 2 � 26. VERIFY EXACT SIZES, LOCATIONS, INVERTS AND ELEVATIONS PRIOR TO RUNNWG ANY PIPING. Y���������� <br /> FIXTURE# FIXTURE � COMMENTS REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ALL FIXTURES AND <br /> COLLECTION FIXTURE UNITS ' SUPPLY FIXTURE UNITS SUPPLY EQUIPMENT. <br /> W� WATER CLOSET- 4 6DFU --- __ ��2 DRINKING _ . <br /> WALL HUNG ; � FOUNTAI N / 0.50 1/2�� 3 2 27. PLUMBING PIPING SHALL BE AS FOLLOWS: WATER PIPING TYPE L COPPER TUBING WITH <br /> + WATER COOLER WROUGHT COPPER FITTINGS 95/5 SOLDER. WASTE AND VENT PIPWG SHALL BE SCHEDULE 40 <br /> � PVC PLASTIC WiTH SCHEDULE 40 PVC SOLVENT FITTlNGS. <br /> L1 LAVATORY-UNDERMOUNT 1 1/2" ! 1 DFU � 1l2" 1.5 SFU 1/2° „ ,� Z � <br /> KITCHEN SINK - 2 1I2 1/2 4 8 0 <br /> --- 28. PLUMBING SUBCONTRACTOR IS RESPONSIBLE FOR EXTENDING ALL REGULATOR VENTS TO <br /> �� I f, „ ATMOSPHERE. REGU�ATORS ARE PART OF EQUIPMENT GAS TRAIN. � <br /> } L2 LAVATORY-WALL HUNG 1 1/2 ; 1 DFU , 1/2 1.5 SFU 1/2 HOSE BIBBS 2.5 ' 1/2" 6 10 � <br /> ��-. -- -- --j---- 29. PIPING SHALL NOT RUN OVER ELECTRICAL PANELS AND SHALL BE COORDINATED WITH WORK �„ o <br /> •� U1 URINAL-WALL HUNG FLUSH VALVE 2" ; 2 DFU --- --- 3/4° oF oTHER TRaoEs. o <br /> N i � <br /> � i 30. ALL WATER AND VENT PIPING RUN ABOVE FLOOR AT CEILING SHALL BE INSTALLED WITH w <br /> - EWC ELECTRIC WATER COOLER 1 112�� 0.5 DFU I --- --- �/2° SWAY BRACING AT ALL CHANGE IN DIRECTIONS, FOR PIPE SIZES 4-INCH AND LARGER. � <br /> � -- ' � ------T- TOTAL NUMBER OF FIXTURES: 39 - � <br /> N ' I j � 31. ALL PIPE SIZING IN ACCORDANCE WITH THE 2017 FLORIDA PLUMBING CODE <br /> U SS1 MOP SINK � 3" ' 2 DFU � 1/2° 2.25 SFU 1/2" <br /> � � _ TOTAL FIXTURES UNITS: - 169 32. SLEEVE WALL PENETRATIONS. SEAL INTERSTITIAL SPACE. � <br /> w Q <br /> � SK1 SINK-SINGLE COMPARTMEN7 1 112�� 2 DFU �/Z° 1 SFU �I2�� TOTAL DEMAND (GPM): - $3.0 33. ALL PLUMBING FIXTURES WITHOUT INTEGRAL TRAPS ARE TO BE PROVIDED WITH P-TRAPS, � <br /> � <br /> � WCLUDING FLOOR DRAINS, MOP BASINS & INDIRECT WASTE CONNECTIONS. � <br /> o SK2 SINK-TWO COMPARTMENT � ��2" 2 DFU ; 1/2" 1 SFU 1/2° o <br /> 0 <br /> o� <br /> ���,�,�.,,�.�,,�,���.���� <br /> } ES/EW SAFETY SHOWER --- --- � 1-1/4"TEPID --- �esigned RK <br /> � <br /> C ------ - - Drawn: RK <br /> � QUICK GONNECT SUPPLY W/SHUT- <br /> Reviewed: RB/JJ <br /> � DF1 DRINKING FOUNTAIN --- --- --- --- 1i2" <br /> � OFF sca�e: t 2"= i'-o" <br /> � Project No. 1900494 j <br /> � Date: 04/19/2019 <br /> / <br /> N <br /> �L . <br /> W <br /> LL <br /> � <br /> � .�..»„��,�„�d�,,,�,.�m<��..m�..�,,�,u�„d x���,�,,, <br /> � Title: <br /> N <br /> � PLUMBING NOTES, <br /> U <br /> SYMBOLS LEGEND, <br /> � ABBREVIATIONS & <br /> Q <br /> HEDULE <br /> �o �,�,�,�.�.�,�,��..�.��,�,��,�,�x,,.ri.,. _ <br /> 0 <br /> Sheet No. <br /> � <br /> O <br /> O� <br /> � P0 .01 <br /> � <br /> , <br /> �. <br /> OO 2017 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON,FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES. <br />