Laserfiche WebLink
illlil . '. <br /> ��4. <br /> 7'� V! <br /> n` V � <br /> W � � •� <br /> � � W � <br /> MINIMUM 10 U � � � � <br /> GAUGE 4� N 0 � <br /> ------. RESTRAINT � � <br /> � � FACTORY WIRED BRACKET ` 6� U � �� � '' <br /> COLUMN LINE MOTOR TO Q w w � <br /> =�— DISCONNECT o o a o N <br /> N <br /> 5'-0° _ � rI, � � �. <br /> _ Q :«�:: <br /> MAIN DUCT • • <br /> � � • r <br /> SPRWKLER PIPING � 12" O <br /> TAPERED CONNECTION 45 ANGLE � �� �j +/- U <br /> � � <br /> �� (IF MAIN DUCT IS RECTANGULAR) PROVIDE ROOF �� <br /> � � OR CONICAL CONNECTION (fF DUCT 10'-0° � "'— CURB COMPATIBLE <br /> p a uau�wevr.vvaa«nnwv�ssuc.suv.w+v.,�> <br /> IS ROUND) � WITH ROOF TYPE � ° ° ° ° 355 Research Parkway <br /> AND PITCH • <br /> Meriden,CT 06450 <br /> VD � (203) 630-1406 ., <br /> ``� �j � // j �� / ISOMETRIC VIEW FLAT PATTERN (203) 630-2615 Fax : <br /> W � <br /> T� RESTRAINT BRACKETS UTILIZED TO SECURE ROOFTOP AIR CONDITiONERS ��"' ���"�' �"""`"' """�""""`�` <br /> WIRING BY - SHALL BE DESIGNED FOR 105 MPH WIND LOADS. STRUCTURAL WIND LOAD <br /> EI.ECTRICAL BACKDRAFT CAC.CULATIONS AND/OR STATE NOTICE OF ACCEPTANCE SHALL BE � <br /> COORDINATE LOCATIONS OF CONTRACTOR DAMPER AVAILABLE FROM THE MANUFAGTURER. RESTRAINT BRACKET QUAI�TITY TO �,.� <br /> L BRANCH DUCT ROOFTOP AIR CONDITIONERS � BE DETERMINED BY PROJECT SPECIFIC CALCULATIONS.AT A MINIMUM, ��}ST� �.q�, �' <br /> PROVIDE 4 BRACKETS PER CURB. RESTRAINT BRACKETS SHALL BE �����OF WAS+Yf��o <br /> SUCH THAT THE SUPPLYIRETURN ATTACHED TQ ROOF CURB WITH (4)#12 TEK SCREWS PER RESTRAINT <br /> AIR DUCT DROPS ARE GENTEREQ 1-114° 1-1/4" BRACKET AND TO ROOFTOP UNIT BASE RAIL WITH (4)#12 TEK SCREWS PER � <br /> x <br /> —�� SUPPLY AIR BETWEEN SPRINKLER PIPING SEE MECHANICAL RESTRAINT BRACKE,AT 2" O.C. RESTRAINT BRACKETS TO BE AES � �: <br /> �- RETURN/EXHAUS7 MAINS PLANS FOR WDUSTRIES MODELAES �R EQUAL. <br /> � � . <br /> AIR CONTINUATION ���+�s��,��a�o �*v`�' <br /> W,A E�I�lJ�� R�IJ/ ��1 �1 I�L E R �S`9N�,���'' . �� <br /> -- EXHAl1�T FAN DET�I L �T�RI N� ��K T D T�I L � '' �' : <br /> � � AN��I T�� -C��� TRIL � �O��DIIVAT���1 3 q. <br /> � NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE <br /> :,.:. <br /> dw����_s_.U.�����.�,�.���,�..r.�_��.__.t.�,___�u��.��.�. � . <br /> � <br /> ., <br /> ROUTE PIPING TO SPLASH BLOCK <br /> LOCATED A MINIMUM OF 12'-0° FROM <br /> TONS SIZE RTU FRESH AIR INTAKE. TERMINATE <br /> 3 THRU 5 3!4" PIPWG ABOVE SPLRSH BLOCK WITH <br /> PIPE STAND AND 90 DEG ELBOW. � <br /> 6 THRU 10 1" STRAP PIPING TO PIPE STANDS � ' <br /> � �«�ry: <br /> � r ' <br /> > 10 1-112" ' <br /> PACKAGED ROOFTOP. ADRPTOR AND 90 DEG ELL FUL�SIZE � <br /> REFERENCE SCHEDULE OF RTU CONDENSATE CONNECTION. � � <br /> INCREASE PIPE SIZE AS INDICATED 0 '� <br /> ON ADJACENT CHART ACCORDING �� � � � . <br /> UNION TO RTU SIZE p �/ � � <br /> �7 `1 FLEXIBLE DUCT. CONNEGT TO LOW <br /> SEE CONDENSTATE PRESSURE BRANCH DUCT. SEE I�IJ � �' <br /> DETAIL FOR ROUTING TEE WITH SCREENED _�� FLOOR PLANS FOR SIZE AND � Q '' <br /> Q��, — RELIEF OPENING � � CONTINUATION � Q <br /> �� � � � � � <br /> PROVIDE ROOF — ROOF CURB ' Q � • <br /> FLASHING (TYP.} • ' <br /> , CLAMP � o, W � <br /> C!� �/ :,'.•: <br /> GAS PRESSURE �� � '� ADAPTOR AND � � � � � � � W °' • <br /> REGULATOR ' � � � ROOF PLASTIC MIPS <br /> --. <br /> __ �", �^_-. ___ __ CLEANOUT PLUG 3" MIN LAY-ON TEE W � <br /> — - — -- <br /> — ---- - --- — --- - - -- — -- �— O v ., <br /> �. , -- � (� I�� _ �_ � � � � . <br /> ��, �� �� �� ROOF CURB /--� � � <br /> \ — � <br /> UNION (TYPICAL) CARBON DIOXIDE DETECTOft � � <br /> CO2 �� - � _.� � _----- -- d/ �AI�RW � CEILING LINE � �+ <br /> WTERNALLY LINED ROOF <br /> GAS COCK— SUPPLY AIR - -- -- - <br /> --�� DUCT SMOKE FOR SYSTEMS NOTES: PROVIDE SECURITY CLIP AT <br /> DUCTWORK ABOVE 2,000 CFM AND ABOVE. <br /> ��� CEILING. REFERENCE S � DETECTOR 1. FLEX DUCTWORK SHALL BE A MAXIMUM OF 6 L.F. EACH SIDE OF DIFFUSER. <br /> FLOOR PLAN FOR � WEIGHTED ROOF PIPING SUPPORT 2. IN AREAS WITH GYPSUM BOARD CEILINGS, (TYPICAL) , <br /> ROUTING S COORDINATE WITH ELECTRICAL EQUAL TO B-LINE C-PORT WITH DIFFUSERS SHALL BE RATED FOR THAT USE. <br /> GONTRACTOR. CHANNEL TO ATTACH PIPWG 3. IN AREAS OF GYPSUM BOARD CEILING, NO FLEXIBLE <br /> DRIP LEG * ' <br /> RESTRAINT/STRAP DUCTWORK SHALL BE PERMITTED. ' , <br /> �� RTU COIV�EI�S�TE [�ET�IL �^_ �ELI �� DI �FU��R DE�f�IL <br /> 5 RO+�F T�F' UNIT '�ETAIL 6 7 <br /> NOT TO SCALE NOT TO SCALE NOT TO SCALE <br /> � _.,�::.a„��,... .�w, „�, ���.,»,�. _v..,m�, � <br /> ., <br /> z <br /> o .�; <br /> � � ' <br /> � <br /> � TRANSITION FROM FULL SIZE OF UNIT OPENINGS TO FULL <br /> � SIZE OF DROP BOX WTRKE. INSTALL SUCN THAT BOX IS U <br /> � , <br /> •— CENTERED BETWEEN THE BAR JOIST 7 ESFR SPRINKLER N W <br /> ACOUSTICAL BATT INSULATION � _-- - - - — ---- - �- --- � <br /> z <br /> � LINES (8"THICK, 4LB DENSITY � ` � ROOF TRUSS O <br /> Q MINERAL WOOL) � � <br /> W <br /> � RTU � <br /> � � � <br /> � 24" ROOF CURB - <br /> •, <br /> � FLEXIBLE GONNECTION \� <br /> U (TYPICAL) , � � TYPICAL BAR — FIELD WELD 2X2X1/4" <br /> - — <br /> . <br /> ROOF `�� <br /> � - FULL SIZE J TO J015T FROM POENT o ' <br /> RETURN ADING TO <br /> F LO �MOUNTING PLATE <br /> � 12" MAX DUCT � . • <br /> NEAREST PANEL POINT (FO�LOW MANUFACTURER'S "�" <br /> d�- --�— -------ENTIRE LENGTH OF RTU INSTRLLATION GUIDE LWES) O • <br /> O <br /> � SUPPLY AIR DUCT SHALL <br /> � COVER OPENWG WITH 1/2"x1/2° BE LINED 1/4"X6"L LAG BOLTS (MIN.} -� 2'-15' EXTENSI N <br /> � HARDWARE CLQTH, 0.135" � - 34°X34" - �� � � � � � ON 10" CENTERS ON (COORDINATE LENGTH � "�""" �">���'��"�'�`��"�°` ��"�`�„�'�` <br /> N LONGEST CURB SIDES. WITH FIELD CONDITIONS p aSgned SP <br /> � WIRE SUPPLY <br /> � DUCT NEAREST FAN <br /> � BOLT TWO B-LWE B24 S7RUTS MINIMU 30 <br /> Review2d: JK/JJ <br /> CURB -� FAN MOTOR& GEAR �� Scale: 12"= 1'-0" '' <br /> � � � I <br /> U ! � ON BOTTOM CHORD OF BAR <br /> � SUPPORT BOX WITH B-LINE THREADED ROD, v JOIST. SUPPORT SUPPLY DROP 1/4"X6" BOLTS OR 3/8 LAG -PRESSURE Project No. 1900494 <br /> � <br /> SCREWS 12" ON CENTER ON ALL Date: 04 19 2019 , <br /> TURNBUCKLE AND J-HOOK AT EACH CORNER. BOX DUCT FROM THE STRUT � TREATED AIR FOILS <br /> �j INSULATED S.A.PLENUM 4 SIDES 2 SIDES MIN ON GEV'S 2°X4"ADJ. -- � <br /> � PROVIDE 1!8" SAFETY CABLE AT EACH <br /> � BRACKET CONNECTED TO BRR JOIST I �----- - I <br /> -- — -- TO PITCH <br /> � OF ROOF <br /> 36" MIN. SEPARATION DISTANCE 4 <br /> �- \ / COORDINATE EXACT ELEVATION WITH <br /> � � � ARCH, DWGS. _ - � ROOF BETWEEN FAN BLADES AND Title ��� ��,� ����� ����� , <br /> � / � 3"X3"X1l4"RTU 2"X2"X1/4°GEV'S � � EQUIPMENT <br /> � /� STEEL(ALL FOUR SIDES) FIEL�D MINIMUM MECHANICAL <br /> WELDED ON TRANE 4TCY/7CC ' INSTALLED HEIGHT PER <br /> � INTERNA�LY LINED 4-WAY DROP PLENUM WITH DRUM - � MANUFACTURERS WALL KEYPAD CONTROLLER DETAILS � <br /> � LOUVERS UNITED ENER7ECH 'DPD' OR EQUAL MOUNT UNITS USE MANUFACTURE TIE , RECOMMENDATION 0 (SPEED CONTROLLER) <br /> U WITH TOP EDGE OF DRUM LOUVERS JUST BELOW DOWN CLIPS TO ANCHOR UNIT TO � o� INTEGRATE WITH BMS LITE <br /> ADJACENT STEEL STRUCTURAL MEMBERS TO THE CURB. <br /> � PREVENT COLD AIR DISCHI�RGE ONTO STRUCTURE & _ �. OPTIONS <br /> - � � - _ — �FINISHED FLOOft ,��� ��� ���,a.y ,����� a�.,.,.,r, �; <br /> � POTENTIAL CONDENSATION. IF DRUM LOWERS ARE <br /> � REQUIREQ TO SE IN STRUCTURE TO MAINTAIN CLEAR LAG SCREWS OR 318 NUT AND WASHER <br /> �� LOCKABLENENTED ENCLOSURE <br /> � HEIGHT, INSULATE STRUCTURAL STEEL IN AIR �ee o. <br /> (SEE STRUCTURAL LETTER FOR APPROVAL) MOUNT 4'ABOVE FINISHED FLOOR- <br /> � DISCHARGE WITH ELASTOMERIC INSULATION. iNCLUDE REFER TO PLANS FOR LOGATIONS. � <br /> � ESFR SPRINKLER HEAD BENEATH PLENUM iN GLEAR <br /> � HEIGHT. � �� • �� '� . <br /> TYPICI�L �TU TI � �OWN DETAI L �II 1� `��LIJM /L�W V L��I1�Y H�/LV F��� D TAI L <br /> � � RTU DROP �Q� DETAIL 9 � � 1 <br /> `� 8 NOT TO SCALE <br /> °' NOT TO SCALE NOT TO SCALE <br /> ., <br /> � � <br /> � <br /> OO 2017 BL COMPANIES,WC. THESE DRAWINGS SHALL N07 BE UTILIZED BY ANY PERSON,FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION QF Bl.COMPANIES. <br /> _ '' <br />