Laserfiche WebLink
,l <br /> ., � <br /> �' , <br /> E . 8 TWN . 29 N . RGE . 05 E . W. M . ���� ��� �� <br /> PURTION OF S C , <br /> � <br /> N - - .. .� <br /> VERETT SNOHOMISH COUNTY WASHINGTO . � . <br /> CITY C� F E , � <br /> � . . <br /> TACOMA • SEATTLE • SPOKANE • TRI-CITIES <br /> 2215 North 30th Street, Suite 300 Tacoma,WA 98403 <br /> 253.3832422 rE� 253.383.2572 Fax www.ahbl.com wEB <br /> Proiect Titie: � <br /> GLACIER <br /> GENERAL IRRIGATION NOTES IRRIGATION SCHEDULE POINT OF CONNECTION NOTES PEAK AT , <br /> 1. THESE PLANS SHALL BE CONSIDERED INCOMPLETE WITHOUT THE SYMBOL MANUFACTURER/MODEL/DESCRIPTION 1. POC: 1" STUB, DOWNSTREAM OF IRRIGATION DEDUCT METER, DCVA, ANo PR�. RIVERSIDE � � <br /> ACCOMPANYING SPECIFICATIONS. 1.1. THE SYSTEM DESIGN IS BASED ON OPERATING ONE ZONE AT A TIME USING � <br /> � RAIN BIRD XCZ-100-PRF A NEW 1" IRRIGATION DEDUCT METER ON A 1.5" SUPPLY LINE. CONTRACTOR <br /> 2. NO SUBSTITUTIONS OF EQUIPMENT OR DESIGN CHANGES SHALL BE MEDIUM FLOW DRIP CONTROL KIT, 1" DV VALVE, 1" SHALL FIELD VERIFY SIZE AND LOCATION. C�ient: <br /> PERMITTED UNLESS APPROVED BY THE LANDSCAPE ARCHITECT (LA). PRESSURE REGULATING FILTER, 40PS1 PRESSURE PANATTON I <br /> REGULATOR. 3GPM - 15GPM. 1.2. IRRIGATION CONTRACTOR SHALL TIE INTO PROVIDED IRRIGATION STUB. <br /> 3. IRRIGATION LINES AND VALVES MAY BE SHOWN IN HARD SURFACE AREAS OR DEVELOPMENT . <br /> OUTSIDE LANDSCAPE FOR GRAPHIC CLARITY. LOCATE ALL IRRIGATION LINES AREA TO RECEIVE DRIPLINE 1.3. HIDE VAULTS AND VALVE BOXES IN PLANTING AREA. <br /> IN LANDSCAPE AREAS OR IN SLEEVES UNDER PAVEMENT. RAIN BIRD XFS-06-24 COMPANY, LLC <br /> - XFS SUB-SURFACE PRESSURE COMPENSATING DRIPLINE 2. COORDINATE METER SCOPE OF WORK WITH ALL APPLICABLE TRADES. <br /> 4. INSTALL ALL EQUIPMENT PER STATE AND LOCAL CODES. CONTRACTOR W/COPPER SHIELD TECHNOLOGY. 0.6 GPH EMITTERS AT 900 SW 16TH STREET <br /> SHALL BE RESPONSIBLE FOR OBTAINING A�L PERMITS, TESTS, AND 24" O.C. LATERALS SPACED AT 24"APART, WITH 3. NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY IF THE POINT OF SUITE 300 <br /> INSPECTIONS REQUIRED FOR THE IRRIGATION SYSTEM. EMITTERS OFFSET FOR TRIANGULAR PATTERN. UV CONNECTION ASSUMPTIONS MADE HERE DO NOT MATCH FIELD CONDITIONS. RENTON, WA 98057 . <br /> RESISTANT. SPECiFY XF INSERT FITTINGS. CONTACT: DONNIE BELK ' . <br /> 5. CALL FOR LOCATES PRIOR TO DIGGING AT 1-800-424-5555 OR 811. SEE <br /> SURVEY AND CIVIL DRAWINGS TO VERIFY UTILITY LOCATIONS. IF UTILITIES Job No_ <br /> ARE DAMAGED IN THE COURSE OF WORK, CONTRACTOR SHALL INFORM THE SYMBOL MANUFACTURER/MODEL/DESCRIPTION CONTRO�LER NOTES <br /> GENERAL CONTRACTOR AND LA, AND MAKE ANY REPAIRS REQUIRED, AT NO 2170746.10 <br /> COST TO THE OWNER. Q RAIN BIRD 3-RC 1. CONTROLLER: INSTALL NEW WALL MOUNTED CONTROLLER ON ACCESSIBLE <br /> 3l4" BRASS QUICK-COUPLING VALVE, WITH EXTERIOR WALL IN SERVICE YARD. CONFIRM LOCATIONS WITH ARCHITECT Issue Set 8 Date: <br /> 6. ALL SLEEVING SHALL BE MARKED, SEALED AND STAKED. ALL SLEEVES SHALL CORROSION-RESISTANT STAINLESS STEEL SPRING, AND LA PRIOR TO INSTALLATION. ` <br /> BE TWICE THE SIZE OF OF THE LINE OR COMBINED LINES. MINIMUM SLEEVE THERMOPLASTIC RUBBER COVER, AND 1-PIECE BODY. <br /> SIZE SHALL BE 4-INCHES !F LOCATED UNDER ROADWAY OR DRIVE AISLE. � 2. PROVIDE 120V FROM ELECTRICAL SERVICE TO THIS LOCATION PER LOCAL <br /> MATCO-NORCA 759 REQUIREMENTS AND APPLICABLE CODES. PE RM IT SET <br /> 7. INSTALL CONCRETE THRUST BLOCKS ON MAINLINE 2-1/2"AND LARGER, FOR BRASS SHUT OFF BALL VALVE, 1/2"TO 4". TWO PIECE <br /> ALL CHANGES IN PIPE DIRECTION OVER 15-DEGREES. BODY, BLOW-OUT PROOF STEM, CHROME PLATED SOLID 3. INSTALL RAIN/FREEZE SENSOR PER MANUFACTURER'S RECOMMENDATIONS , , <br /> BRASS BALL, THREADED, WITH PTFE SEATS. SAME SIZE AND TEST FOR CONTROLLER CONNECTIVITY. RAIN SENSOR SHALL NOT BE � • <br /> 8. SPLICE CONTROL WIRES WITHIN VALVE BOXES ONLY, USING 3M-DBY, OR AS MAINLINE PIPE. INSTALLED UNDER TREES OR OVERHANGS OR WHERE IT WILL BE AFFECTED 4/26/2019 � <br /> • APPROVED SPLICE KITS, AND PROVIDE A 24" EXPANSION LOOP FOR ALL BY THE IRRIGATION SYSTEM OR OTHER SOURCES OF WATER OTHER THAN <br /> CONTROL WIRES WITHIN EACH VALVE BOX. MV RAIN BIRD EFB-CP 1" RAIN. <br /> 1", 1-1/4", 1-1/2", 2" BRASS MASTER VALVE, THAT IS <br /> 9. INSTALLER TO ADJUST ALL ZONE CONTROL VALVES TO THE CORRECT CONTAMINATION PROOF W/SELF-FLUSHING FILTER <br /> OPERATING PRESSURE. SEE VALVE SCHEDULE FOR OPERATING PSI. SCREEN. GLOBE CONFIGURATION, RECLAIMED WATER �� ��� AN���,l,C <br /> COMPATIBLE, AND PURPLE HANDLE COVER DESIGNATES . <br /> 10. VERIFY AT LEAST A '15PS1 DIFFERENCE BETWEEN PRS DEVICES_ IF PRESSURE NON-POTABLE WATER USE. � �� �,%%�'��`°2 0 <br /> DIFFERENCES IS LESS THAN 15PS1, NOTIFY L.A. IMMEDIATELY. � !�' z <br /> Q 3/4" BRASS DRAIN VALVE C RITI CAL ANALYS I S �� '�J • <br /> 11. CONTRACTOR SHALL HAND TRENCH IRRIGATION DITCHES WHEN WITHIN 20 !j � �o c� <br /> FEET, OR DELINEATED ROOT PROTECTION ZONE, OF EXISTING TREES TO BF FEBCO 850 W/650A 1" '' o �v <br /> REMAIN. AVOID CUTTING ANY ROOTS OVER 3" -4" IN DIAMETER WITHIN THE --� DOUBLE CHECK BACKFLOW PREVENTION, 1/Z"TO 2" y� Li�' °`�� � " ' <br /> Generated: 2019-05-01 10:43 Os FXP �3�1 �� , <br /> ROOT PROTECTION ZONE <br /> C RAIN BIRD ESP8LXMEF-LXMM WITH (01) ESPLXMSM4 �'q P E A RG - • <br /> 12. INSTALLER SHALL BE RESPONSIBLE FOR KEEPING EXACT ACCURATE NOTES � 12 STATION CAPABLE COMMERCIAL CONTROLLER. P.O.C. NUMBER: 01 04.26.2019 <br /> AND "AS-BUILTS" FOR THE CREATION OF THE "RECORD DRAWINGS" OF THE MOUNTED ON A POWDER-COATED METAL CABINET. Water Source Information: <br /> INSTAL.LED SYSTEM. FLOW SENSING AND WATER MANAGEMENT CAPABILITIES. <br /> FLOW AVAILABLE <br /> 13. CONTRACTOR SHALL WARRANT THE IRRIGATION SYSTEM PER OS RAIN BIRD RSD-CEX Water Meter Size: 1" <br /> SPECIFICATIONS. RAIN SENSING DEVICE, CONDUIT MOUNT. WITH Flow Available: 38.00 gpm <br /> THREADED ADAPTER, EXTENSION WIRE. <br /> PRESSURE AVAILABLE No¶cE <br /> 0� WATER METER 1" Static Pressure at POC: 99.00 psi ""m""°""a�"�s°°""E"r s�"LL"°"�"�'"E <br /> a�a�ssa,a sEu uo s�xun�.aua�na�a� <br /> Elevation Change: 5.00 ft 'ws°°a�"T°°a"°T°°�c"��x°''"'� <br /> OMIERSf�RNi17S W IL 7iN5 DOqA1FNT IS FOR USE <br /> Service Line Size: 1 1/2" t711Y FOR 7FE PRO�ECf�E111FED N ifE 117LE�Op( <br /> IRRIGATION LATERAL LINE: PVC SCHEDU�E 40 "'�'S N0T T0�"�D��''""'�°R . <br /> Lenqth of Service Line: 20.00 ft �oa�+m n+�r aRaEcr aa rnR tirn onfx PaaEcr. , <br /> IRRIGATION MAINLINE: PVC SCHEDULE 40 Pressure Available: 96.00 psi � <br /> - -- -- -- - -- - <br /> _ PIPE SLEEVE: PVC SCHEDULE 40 DESIGN ANALYSIS <br /> TYPICAL PIPE SLEEVE FOR IRRIGATION PIPE. PIPE Maximum Station Flow: 14.57 gpm <br /> S�EEVE SIZE SHALL ALLOW FOR IRRIGATION PIPING AND Flow Available at POC: 38.00 gpm <br /> THEIR RELATED COUPLINGS TO EASILY SLIDE THROUGH Residual Flow Available: 23.43 gpm <br /> SLEEVING MATERIAL. EXTEND SLEEVES 18 INCHES Critical Station: 7 � <br /> \/AI \/F SC;HFf�l1LE BEYOND EDGES OF PAVING OR CONSTRUCTION. Design Pressure: 40.00 psi <br /> NUMBER MODEL SIZE TYPE GPM PSI PSI @_ POC vaive cauout Friction Loss: 6.67 psi <br /> Valve Number Fittin s Loss: 0.67 si <br /> 1 RAfN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 14.35 58.32 80.34 9 P <br /> 2 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 15.05 62.69 88.40 # #�-Valve Flow Elevation Loss: 0.00 psi � <br /> 3 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 12.17 53.50 78.10 #" vaive s�ze Loss through Valve: 13.43 psi <br /> 4 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 11.65 55.58 80.47 Pressure Req. at Critical Station: 60.77 psi : , <br /> 5 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 14.57 57.40 90.31 Loss for Fittings: 1.90 psi � <br /> 6 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 13.97 57.63 88.35 Loss for Main Line: 19.05 psi � CHANGES FOR TENANT 4/26/2019 <br /> 7 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 13.52 60.77 90.76 Loss for POC to Valve Elevation: 0.00 psi <br /> 8 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 9.$7 51.17 71.34 Loss for Backflow: 6.94 psi <br /> 9 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 6.29 46.47 57.12 Loss for Master Valve: 1.05 psi <br /> 10 RAIN BIRD XCZ-100-PRF 1" AREA FOR DRIPLINE 1.82 43.06 48.91 Loss for Water Meter: 1.05 psi � RETAINING WALL DESIGN - 1/14/2019 <br /> Critical Station Pressure at POC: 90.76 psi <br /> Pressure Available: 96.00 psi Rev�s�ons: <br /> Residual Pressure Available: 5.24 psi <br /> Sheet Title: <br /> IRRIGATION � <br /> SCHEDULE � � <br /> Desiqned bv: Drawn bv= Checked bv: <br /> AG AG KKC <br /> :,s <br /> � Sheet No. ` <br /> � A5 <br /> � � � <br /> � �� � <br /> Know what's b@IOW. � � <br /> C111 before you dig. �2 of �o Sneets <br /> DATE: May 1, 2019 FILENAME: Q:\2017\2170746\40_LAN\CAD\2170746-SH-IRRIGATION.dwg , <br />