Laserfiche WebLink
I _ <br /> � CEILIN� GE1oTER.AL N�TES � <br /> . � , <br /> I . PROVIDE AND IN5TALL NEW 2X4 CEILING GRID WITH ACOUSTICAL PANELS TO BE <br /> ARMSTRONG: DUNE ANGLED TEGULAR, UNLESS NOTED OTHERWISE. W <br /> 2 . VERIFY EXISTING CEILING HEIGHTS & ALL DIMENSIONS PRIOR TO WORK. � <br /> 3 . DEMOLISH AND REMOVE ALL UNUSED WIRING BACK TO SOURCE. <br /> •�•••• 4. REMOVE ALL EXISTING IMPROVEMENTS AND FIXTURES AS NECESSARY TO ACCOMMODATE � <br /> •.•.�.•p�.•�.•.•.•..•.•.• NEW WORK. <br /> 5 . THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION WORK � <br /> • ••• ��� REQUIRED TO IMPLEMENT NEW WORK, AS SHOWN IN THE DRAWINGS . <br /> , . ... � <br /> '.""" .' 6 . PRIOR TO DEMOLITION, GENERAL CONTRACTOR TO VISIT THE SITE AND VERIFY EXTENT <br /> ....�:.�•....:...::::: OF DEMOLITION ACTIVITIES REQUIRED FOR NEW CONSTRUCTION. � <br /> ••• "' 7 . THE CONTRACTOR SHALL ENSURE THAT THIS PROJECT AND ALL CONSTRUCTION <br /> os S .. ...... <br /> F .. <br /> ACTIVITIES RELATED THERETO CONFORM WITH ALL LOCAL, REGIONAL, STATE AND/OR �G <br /> � S ' '�•• "' �• •• ���� • FEDERAL REGULATIONS PERTAINING TO DISTURBING, DISPLACING, AND/OR REMOVAL OE <br /> ::; •,�•••••� ,., ••• �. ASBESTOS OR MATERIAL5 CONTAINING ASBESTOS. <br /> •;•'•:•ds•:•;•;�;•:•;•;•;•:•:•;•,�•;�;•;•;•,•;•.•. <br /> ....... ... 8. PROTECT ANY ITEMS TO REMAIN AGAINST DAMAGE DURING DEMOLITION AND <br /> •� �������������� � CONSTRUCTION. o . <br /> . . .. .. ... N U <br /> ••.•.••'•':: .... '.'.;'�;:::::;; 9 . ALL NEW SWITCHES AND EXISTING SWITCHES FACEPLATES TO BE DECORA / ROCKER cv � <br /> STYLE AND SHALL BE AT 48" A.F.E. UNLESS NOTED OTHERWISE. }.� � � � <br /> . — — v1 0� �n � <br /> — — os lO. MINIMUM ACOUSTICAL TILE REQUIREMENTS: N.R.C. (0.90) & 200 A.C. RATINGS IN � a M � <br /> — — — — — — OPEN OFFICE AREAS. ,.d � � � <br /> 11 . PROVIDE EMERGENCY EGRESS LIGHTING THROUGHOUT IN WHITE. VERIFY EXACT U � ,Ij •� <br /> _ LOCATIONS WITH FIRE MARSHAL PRIOR TO INSTALLATION. THE MEANS OF EGRESS W '� M ,b <br /> _ SHALL BE ILLUMINATED AT ALL TIME5 THE BUILDING IS OCCUPIED WITH AN � � � � <br /> _ �••••••••��•••••• ILLUMINATION LEVEL NOT LESS THAN 1 FOOTCANDLE AT THE WALKING SURFACE. � 3 'b <br /> ................. N � .. �r� <br /> — . •• ...�� 12 . SWITCHING TO REMAIN WHERE NONE SHOWN. u�j � p,, o <br /> - - ����� '� ' 13 . PROVIDE AND INSTALL EMERGENCY EXIT SIGNS, HORNS, AND EMERGENCY LIGHTING <br /> PER CODE. VERIFY LOCATIONS WITH DE5IGNER. Consultant <br /> - 14. DESIGNER NOT RESPONSIBLE EOR VENTILATION REQUIREMENTS OF MEDICAL <br /> EQUIPMENT. VERIFY VENTILATION REQUIREMENTS WITH DOCTOR AND EQUIPMENT <br /> SPECIALIST. <br /> 15 . SUBMIT LIGHTING SCHEDULE TO DESIGNER FOR APPROVAL. <br /> N 1 �.�F'�,���'�� ����,Z�� ��,.�� <br /> 16. FIRE REQUIREMENTS UNDER SEPARATE PERMIT. PROVIDE AND INSTALL ALL NECESSARY <br /> I A1 . 5 SCALE:3/16" = 1 ' -0" FIRE REQUIREMENTS PER 2015 IBC AND AMENDMENTS , AND ALL OTHER APPLICABLE <br /> CODES (INCLUDING FIRE EXTINGUISHER - VERIFY LOCATION WITH DESIGNER) . USE <br /> CEILING MOUNTED WHITE FIRE ALARMS IE POSSIBLE. . <br /> 2- 1/2" 20 GA . METAL STUDS @24" OC <br /> ATTACHED AT STRUCTURE ABOVE USING STUB NAII,S , 17 . VERIFY LEAD TIMES FOR LIGHTING AS SOME PRODUCTS MAY HAVE EXTENDED LEAD <br /> - POWER-DRIVEN FASTENERS . AT FRAMING USE 1 - 1/4" TYPE TIMES . <br /> S OVAL HEAD SCREWS OR $D NAILS . TO ALL SUBSTRATES , 18. ELECTRICIAN TO VERIFY DAYLIGHT ZONES AND INSTALL DAYLIGHT CONTROLS PER <br /> SECURE RUNNERS WITH FASTENERS LOCATED 2" FROM ENDS CODE. <br /> � I �11 .1. � ��� V�� ����i�� AND SPACED 24'� OC MAX . 19 . WHEN APPLICABLE, PROVIDE AND INSTALL OCCUPANCY SENSORS WITH WALL MOUNTED <br /> SYMB . DESCRIPTION � ����G,� � �n��4 �s��s �l�1�✓`�� MANUAL SWITCHES CAPABLE OF AUTOMATICALLY TURNING OFF ALL THE LIGHTS IN AN <br /> AREA, NO MORE THAN 30 MINUTES AFTER THE AREA HAS BEEN VACATED. 5EE RCP FOR � <br /> NEW VANITY FIXTURE ; MINKA LAVERY GOOD LUMENS 2 LIGHT <br /> 9 i-�i i OCCUPANCY SENSOR LOCATIONS. .�.� W <br /> 16" WIDE LED BATH BAR � _ E' <br /> 20. ALL LIGHTING & CONTROLS TO COMPLY WITH THE 2015 WSEC. � �-{ <br /> NEW PENDANT FIXTURE ; ELEGANT LIGHTING IVY SINGLE ' <br /> �� IDE LED SUSPENSION MINI PENDANT A.F.F. 24" - 30" VARIES 22. CLOTHES DRYER (IF APPLICABLE) TO BE VENTED TO EXTERIOR PER CODE. G�I L�l� <br /> � LIGHT 6 w � <br /> SEE PLAN <br /> . <br /> NEW 2 � X 4 ' LED FIXTURE : CREE ZR24 (OR EQ) CEILING TILE PER 23 . CEILING GRID IN OPS AND HYGIENE ROOMS TO BE CENTERED DIRECTLY OVER DENTAL � � <br /> � O <br /> CHAIR. VERIFY LOCATION WITH EQUIPMENT SPECIALIST. � � N <br /> NEW 6'" CAN LED FIXTURE WITH EMERGENCY � <br /> SCHEDULE 24. MECHANICAL ROOM ��103 ; HARD LID CEILING AND ALL WALLS TO HAVE GLUED ON � H � <br /> BALLAST : PHILLIPS-PR6 LYTE PROFILE <br /> SOUND PANELS. SOUND BATT INSULATION TO BE LAYED ON CEILING ABOVE THE GYP. � H <br /> ' - E PROFILE 2s . �DEMO EXISTING CEILING GRID AND LIGHT FIXTURES � �, � <br /> O 6 LED CAN; PHILLIPS PR6 LYT <br /> S�$�� GYP �D . g�-O�� I 26 . PROVIDE SEISMIC CEILING SPLINE BRACING AS IS REQUIRED BY ASTM C 635 , C � � � " <br /> NEW EXHAUST FAN 636 AND SEISMIC DETAILS ON A1 .5 � � W � <br /> � A.F.F. �' � W <br /> 27 . ALL LAY-IN CEILING GRIDS AND LIGHTING SHALL BE INSTALLED AND SECURED PER � � � <br /> EXIT NEW EMERGENCY EXIT SIGNAGE & LIGHT THE PROVISIONS OF ASTM C 635 AND ASTM C 636. � / � W� <br /> NEW LIGHT/EXHAUST FAN COMBO 2 ���' �' I� ���.�I�° C���ERAT.� D1��IJ I��IT LON�° N�TE S � � � W <br /> � <br /> � � A1 .5 SCALE: N.T. S � � N <br /> W O <br /> ALL DAYLIGHTED ZONES AND DAYLIGHT ZONE CONTROLS SHALL COMPLY WITH THE 2015 H � <br /> N <br /> � WASHINGTON STATE ENERGY CODE. <br /> u� DEs u4i9 '� <br /> PRIMARY DAYLIGHT ZONE: EXTERIOR WINDOW HEAD HEIGHT X WINDOW WIDTH + 2' pN <br /> F I RE RAT I NG EITHER SIDE. SECONDARY DAYLIGHT ZONE: AREA EQUAL IN SIZE TO THE PRIMARY <br /> l�� I� IIV� ����1.V� 1 HOUR ZONE <br /> SYMB. DESCRIPTION <br /> SYSTEM THICKNESS AUTOMATIC DAYLIGHT SENSING CONTROLS SHALL BE CAPABLE OF REDUCING THE LIGHT <br /> . NEW GYP CEILING 9 ' -6" A. F . F . OUTPUT OF THE CONTROLLED LUMINAIRES WHILE MAINTAINING A UNIFORM LEVEL OF <br /> � 4 - 7 ���� ILLUMINANCE �Y CONTINUOUS DIMMING TO AT LEAST 20% LIGHT OUTPUT. DESCRIPTIO DATE <br /> — - NEW GYP SOFFIT H � -O�� A. F . F . PAINT ALL SIDES P- ASSEM�LY : DAYLIGHT SENSING CONTROLS SHALL CONTROL ONLY LUMINAIRES WITHIN THE DAYLIGHTED PERMIT SET 09/24/19 <br /> � _ 9i <br /> 5 �8 �,IRE � S���Z,ROCK AREA. 1 PERMIT REV 10/29/19 <br /> NEW 2 ' X 4 ' CEILING GRID @ 9 ' -6'° A. F . F . - 3 - 1/2" 25 GAUGE STEEL STUDS 24" OC <br /> � TILE TO BE ARMSTRONG SECOND LOOK : DUNE - OPTIONAL INSULaA`I'ION AUTOMATIC DAYLIGHT SENSING CONTROLS SHALL INCORPORATE TIME-DELAY CIRCUIT5 TO <br /> PREVENT CYCLING OF LIGHT LEVEL CHANGES OF LESS THAN THREE MINUTES. <br /> - 5 /8" FIRE X SHEETROCK <br /> DAYLIGHT RESPONSIVE CONTROLS SHALL BE CONFIGURED TO COMPLETELY SHUT OFF ALL <br /> CONTROLLED LIGHTS IN THAT ZONE. <br /> v EXCEPTIONS : SPACES WHERE PATIENT CARE IS DIRECTLY PROVIDED (2015 WSEC SECTION <br /> .:. . :. ,, ,._... • •_. . . ,...:. . .., :;.. -...... , .. �: . . . ... ;. .., .. . � ... : : . ..... . ..:-. <br /> C405 .2 .2 EXCEPTION ��2) . <br /> � �� . ,� . �•::._ ��� ��� � 8et FIR�.'� � FILE �k: <br /> i X X� X / <br /> 1 / \' �I J , � <br /> �- / \ � / \ Jl � . � <br /> .. .; . . . ... .. .:;_ .. , :, , :. ,. , ;:, .. . ; ,., , .. �:_ _ ._. . . :. . : .. . . :... . ,.. SHEET ROCK JOB: aols-a9 <br /> INSULATION STUD Dwrr: AB CHK: -- <br /> �����'� ��� �a 3.�� ���� �,�. <br /> 3 1 - HOt�R FIR� RA'�E� CEILIN� D�� IL <br /> �_� :�����'���`a ������� �=3�.����i���� <br /> A1 . 5 SCALE: N.T. S <br /> . <br /> A � � 5 <br /> :, u. <br />