W <br /> � s <br /> R-21 WALL INSUL w/ 2x6 STUD WALL <br /> Q <br /> VAPOR BARRIER <br /> 1/2" G.W.B. <br /> 2x4 PT SILL PLATE w/ 1/2" x T&G PLYWOOD OR EQUAL � <br /> 10"AB PER PLAN. 7" MIN EMBED — SEE SPECS � <br /> w/ 3"x3"x0.229" SQ WASHERS MIN al <br /> 2 EA PC & w/IN 12" EA END & 1ST FLOOR JOISTS SIMPSONABU66 , �oor�ng°pen�ng.ne�; <br /> 7x BOLT DIA MIN FROM END 6X6 PT POST , o, POST BASE existingopening,new '� � <br /> � •o • i� i� �J Window Q � I <br /> �� � L__l� <br /> � /// // �Z� � BARS � 'S) New Toilet � Q <br /> �� P EACH WAY <br /> �b) New 5ink <br /> � R-30 UNDERFLOOR INSUL. \ •_� • \j�` � _ <br /> D: <br /> � 6 MIL BLACK VAPOR BARR. // - Q f� q <br /> VENT 1/150 PER Z / // '. \ \ \\ \\` 7'' "�,"r'"� z z W W ' <br /> , , , <br /> I R C 408.1 � \\ - � / /, �\ �\ �\ / / e� New 5hower � H Z � � � <br /> REBAR ABOVE - � �/� 16�� Existing � c/� Q W W = <br /> � r \ \ 3 c� c.� w <br /> VENTS ;�' � \� #4 REBAR 18" o.c. HORIZ <br /> / / �i 1 TOP & 1 BOT OF WALL '`!' shower � q Q � � Q <br /> (� W � _ = f- <br /> �� � � '10� Existing 5ink <br /> �— STO�Y FOOTING' $ #4 REBAR 48" o.c. VERT E SONO—TUBE DETAIL - <br /> 15" (2) #4 REBAR CONTINUOUS <br /> �11 Existing Toilet � <br /> SCALE: 1"=2 FT SCALE: 3/4" = 1' - 0° �--- <br /> smoke detector %fi7 1i�t7t.l� l��/1-Q �//I�liG.{' '.,�%�i r /?-::�`7"��t/ ��vK-=i�` � <br /> � ��'' S0-150 GFM Fan <br /> `�_ �.{''"..� \,;i <br /> � � /� _ :� , <br /> 1/ � Garbon moncxide datector <br /> ti <br /> 4� _� r r Tempered giass R308 IRG � <br /> z <br /> 1' S'-1" 6'-3 1/2" ' " 6'-6" — 8'-3 1/2" 12'-5" " � <br /> � <br /> H <br /> � <br /> W <br /> 2 F , - � General Drawinq Notes� New Construction Specif'ications � <br /> �' DESIGN CRITERIA� <br /> -- - . - _ _ _ -- <br /> I ; � WIND L�AD� Per IBC� Ultir�ate Wind Speed=110 mph, exposure B <br /> ; ; ' � ' �'-9"— SEISMIC� Per IBC,, I=1,0, SEISMIC DESIGN CATEG�RY D, SITE CLASS D <br /> LL=zS PSF <br /> � a_vza� s i' ` � F�LOOR/DE�CK�L AD� DL��10 PSF, LL=40 PSF <br /> � �� : � Landin � <br /> � 16' �'- / " �- r S❑ILS� AssuMed 2000 PSF Altowable Soil Bearing <br /> � � � � C�NCRETE� 2500 PSI @ 28 days, Grade 40 reinforcer�ent- covered 3" min, � <br /> � ��i`�� J X ! <br /> �i ? � � � ' The following basics fror, the International Residential Code CIRC) 2015 shalt be � <br /> N N; � adhered to in this plan-set� Cnot all iter�s May apply) <br /> � I T � �' 1, Material� a) HF#2 r�in frar�ing lur�ber b) Use HF#2 r�in PT plates c) O <br /> ' _ ;� � L � 3/8' r�in APA rated plywood d) 2000 psi min concrete strength e) 24F-V4 = <br /> f-- X � � � � � r,in glu-lar� tir�bers per 106,3,3 <br /> � Q c� N U ' � 2, Section R302,6, House to garage separation shall be of <br /> � � � _ � � 4x4lpost with BC4 POST CAP � r�aterials approved for 1-hour fire resistive construction <i,e„ 1/2" type O � <br /> � � E � � � E "X' G,W,BJ, Doors in these areas shall be 1-3/8" miniMur� thickness, solid <br /> CU core, with self-ctoser hardware, <br /> � � <br /> � � 5�-4 1��C° S1 '� ,� � � S1 1 I , 3, Section P2708, All shower areas to be f inished with a sMooth, � � <br /> � �, � � c6 � C1J non-absorbent r�aterial to a height of 70 above drain. tl � N o <br /> � C� - � � � 4, Section R307, A toilet cor� artr�ent shall not be less than 30 wide, _— (U <br /> � y o 4x4 post with BC4 POST CAP � � � �, P _ <br /> _� <br /> \ HM and have a front clearance of 24", � � � <br /> � ?' ,� �''� '-1�° � O o ,� � 5, Section R606, Masonry shalt not be supported by any wood <br /> � I� `� �- � r�eMber. � <br /> � o � , " � 0 � ClJ ' 6. Section R408. Crawl space under floor joists shatt be at teast 18'' & a � <br /> '� � � ; � � X � r�iniMUM of 12" to bottor� of girders, Underfloor area to be provided � 3 <br /> CO , _ ' <br /> � � � Z99Z 8�_8�� . �" - with a Minir�ur� 18'`x24" size access, located within 20' of Main plumbing <br /> �' Q N ctean-out, �n I <br /> � � CU 4x4 post with BC4 POST CAP '��M� "` a N 7, Section R317, Alt wood in contact with concrete or masonry shalt be W � � <br /> ClJ � � � , pressure treated, �.{ <br /> C'� �, 6x12 GLB lJ � � <br /> � 8. Section R317, Wood girders entering concrete or r�asonry shall be <br /> Cl.l � �� � �� � �� � ,, <br /> '°� � provided with 1/2" air space on sides, top & end, S � � <br /> 4 1/ —1 —2 �� 9, Section R408,1, MiniMur, foundation ventilation� 1 square foot for every <br /> � �- � � �� 150 square feet of under-floor area, Covered with 1/4" or less wire U Q W <br /> o �6 -1� 1�2 = � Mes h C r e s t ri c t s o p e n i n g a r e a 2 5%) _— <br /> CL1 S -g o � 10, Section R302, Firestops shall be provided to cut-off concealed draft � <br /> ���-" � � � � � � openings between stories and roof space, <br /> •�` . } � � N � 2 11, Section R807, A 22"wx30"h attic access opening shalt be provided in an <br /> ��`�`' � �D Lallding _ � X � � � �"j area that has 30" r�inir�uM of headroor�, <br /> '�y ,�� � ' Z o �` 2x10 � 16" O.0 12, Section R806,2, Cross-attic ventilation required at 1/150 of the attic <br /> �� � W � - area or enclosed rafter space, Continuous vent each enclosed rafter <br /> ' I�3��5° 11�-1�� space, If raf ters are enclosed & roof s are of sotid sheathing, a <br /> continuous ridge vent is required, cover vents with 1/4" r�ax. opening <br /> + Mesh. <br /> �—_ � 2 � 2 13, Section R311J.4, Maxir�uM stairway rise is 7-3/4", MiniMum run is 10", r,inir�uM <br /> ° hea d r o o m i s 6'-8". E n c l o s e d u s a b l e s p a c e u n d e r s t a i r w a ys shall be of <br /> � o , <br /> o ~ ozcz `-' Haozoz 1/2" Gypsur� Wall Board CGWB), <br /> CZ.J 2 <br /> � 14, Safety glazing shall be used in 1) doors other than <br /> � � wardrobe, 2) bathtub & shower enclosures, 3) glazing tess than 60" from -- \ <br /> � floor & ad jacent to a door within 12" & 4) glazing in excess of 9 sq, �t aJ � <br /> �, �, & less than 18" froM ftoor, R308,4 Hazardous locations, � � <br /> z 2 � � <br /> � \ , , ;f ,%. ; f � J � .� � 15. ChiMneys shall extend over 36" above roof where it � <br /> _ ,(�.b�-� -- ��-' � .- ��- ��`�-•�� _�, .�=--=- passes through, & 24" above any structure within 10', � <br /> � HQOlOE HOOZO£ � � � � <br /> � � 16, Cor,bustible Materials shall not coMe within i" of fireplace, U <br /> -"'°`�'"'"'01 sMoke char�ber or chiMney walls, 1001,6 Terr�ination, <br /> `� .; 17, ❑ne 110 vott, battery back-up, interconnected sMoke � \ <br /> , �� � �_ �� � � �� � � �� � �- �' '�etector in each bedrooM and hallway leading to a bedroor�. � <br /> 1 —''�'1 1/2 3 3 2 3 1/ � 5 Z 2 18 2 1/2 �� <br /> , �/ , Eaves have 1' thick fascia boards, with 5" prefinished continuous <br /> � etal gutters, Matching 2"X3" downspouts with concrete splashblocks, <br /> 1�'-8 1/�" �7'-11° C��� 0 Slope finish grade away fror� Poundation wall, 1/4"/ft Min, for 5' fror� <br /> 1'-� 1/�' �i%� " oundation, <br /> � �� � l, MiniMur� ceiling height in structure is 7'-6", with <br /> 4 '-5" � � <br /> 2� �xceptions for halls, kitchen & bathroor�s to be 7'-0" Min, height, <br /> j: �� 22, Trusses shall be designed by a licensed Washington <br /> . .,-K.�����"' " �� State Structural Engineer, Snow load will be deterr�ined by the Building <br /> �'� `" "'" � `� � ��� � ❑fficial, Truss r�anufacturer will supply engineered shop drawings for <br /> B a s e r�e n t L Q �U� � � building departMent approval, and all trusses supptied will be Marked <br /> � accordingly, <br /> ''� 23, Provide r�echanical ventilation capable of providing 5 <br /> �,;�*_ ,n; -- � air changes per hour in bathrooMs, water closet cor�partr�ents, laundry <br /> C❑D E R E F�E E N C E S EGRESS/ IRC -R310 and sir�itar rooMs, <br /> BEDROOM SILLS 44'MAX H 24, Exterior joints shall be sealed, caulked, gasketted or <br /> INTERNATIONAL RESIDENTIAL C❑DE 2015 T❑ FINISHED ❑PENING weatherstripped to lir�it air leakage at the foltowing openings <br /> INTERNATI�NAL MECHANICAL C�DE 2015 MIN 20•wX2a' HI OPENING TABLE R406.2 SUMMARY E N E R G Y C❑D E C❑M P L I A N C E <br /> INTERNATI�NAL FIRE C�DE 2015 5.� sQ FT MIN - R310.1 OPTION DESCRIPTION CREDITS a� Windows & door frar�es b) openings between walls & <br /> 2015 RESIDENTIAL PRESCRIPTIVE COMPLIANCE CHART foundations c)between walls & roof d) openings at penetration of utitity <br /> UNIF❑RMED PLUMBING C❑DE 2015 N❑TE� ALL HEADERS 1 a EFFICIENT BUILDING ENVELOPE 1 a 0.5 ZONES 5 and MARINE 4 CHAP 51-1 1 R WAC services d) all other openings in the building envetope, <br /> WASHINGT❑N STATE ENERGY CODE 2015 4x8 HF#2 U,N,�, �b EFFICIENT BUILDING ENVELOPE 1 b 1.0 FROM TABLE R402.1.1 ZS, Atl exhaust ducts to be 26 GA miniMur� CUMC Sec 601,7) <br /> 1 c EFFICIENT BUILDING ENVELOPE 1 c 2.0 FENESTRATION U value 0.30 26, All fasteners in contact with PT r,atl hot-dip galv or stainless � <br /> N❑ricE oF �taBz�ITv wr�cten a��,en5�on5 on the5e araw�ngs 1 e EFFICIENT BUI�DING ENVELOPE 1 d 0.5 SKYLITE U value 0.50 <br /> ALL HOLD❑WNS, FRAMING ANCHORS & Sha�� ha�e Preferen�e o�er S�n�=d d��,ens�ors. "o�,eowner� <br /> SHEARWALLS MUST BE INSPECTED c°"t"°`t°" 5"°" `"e``` s� �e"�`Y °�` d��e"5�°ns nnd `ond�t�ons 2a AIR LEAKAGE CTRL/EFFICIENT VENT 2a �•5 CEIUNG R value 49 <br /> Perta�n'�ng to the Pro�e�t pr�or to Pra�eed�ng to t"e 2b AIR LEAKAGE CTRL/EFFIC�ENT VENT 2b 1.0 WALL R value 21 O <br /> BEF❑RE C�VERING, �onstrU�t�on PhaSe. eea�, s�ZeS are est�matea bUt not <br /> En9�neer;ng �ert�f;ea anY d�S�rePan�y snau be reso��ed W�th 2c AIR LEAKAGE CTRL/EFFICIENT VENT 2c 1•5 FLOOR R value 30 \ <br /> Pze pr;or to pra�eed�ng w�th tne Work, or cantra�tor 5hau 3a HIGH EFFIECIENCY HVAC 3a 1.0 SLAB R value 10-2ft <br /> acwpt full responsibility for rectifying saroe In event that �1 <br /> UNDERFL�❑R INSPECTI❑N REQUIRED ��ob��'�tY �5 ��,Posed on p2b, aur ��ab'���tY to yoU or any t"�rd 3b HIGH EFFIECIENCY HVAC 3b 1.0 DWELLINGS <1500 SQFT REQUIRE 1.5 CREDITS � <br /> PRI❑R T❑ INSTALLATI❑N ❑� ANY P°"ty 5"°" "°t e"`eed t"e P"��e P°�d f°r pzB 5 Pr°d`"`t' 3c HIGH EFFIECIENCY HVAC 3c 1.5 DWELLINGS 1500 TO 5000 SQFT REQUIRE 3.5 CREDITS <br /> FL�❑R SHEATHING ❑R DECKING, SUBJECT TO FIELD INSPECTIONS, 3d HIGH EFFIECIENCY HVAC 3d �•� DWELLINGS >5000 SQ FT REQUIRE 4.5 CREDITS <br /> CORRECTIONS & PROVISIONS OF 4 HIGH EFFICIENCY HVAC DIST. SYS. 1•� OPTION CODES WILL BE USED FOR THIS BLDG. � <br /> PR❑VISI�N SHALL BE MADE T❑ PLAN CHECK 5a HIGH EFFICIENCY WATER HEATING a•5 HEATING DUCTS NOT ALLOWED TO DISPLACE INSULATION <br /> PREVENT WATER FR❑M C❑LLECTING 5b HIGH EFFICIENCY WATER HEATING 1.0 y�/ITHIN THE EXTERIOR WALLS FLOORS & CEILINGS. <br /> 5c HIGH EFFICIENCY WATER HEATING �•5 <br /> IN CRAWLSPACE & FR❑M LEAKING LANDINGS / IRC R311,4, DUCTS SHALL BE LEAK TESTED PER RS-33 USING MAX <br /> INT❑ BASEMENT FL��RS, � Door Widthx36'D MIN 5d HIGH EFFICIENCY WATER HEATING 0.5 DUCT LEAKAGE RATE SPEC'D IN SECTION 503.10.3. <br /> � 7-3/4' MAX DR❑P 6 RENEWABLE ELECTRIC ENERGY 0.5 A WH❑LE H❑USE AIR LEAKAGE TEST IS REQUIRED � <br /> WALL BRACING PER CURRENT IRC A WH❑LE H�USE VENTILATI�N SYSTEM IS REQUIRED, n ' <br /> Wall bracing in D1 seismic zone to meet the following; ALL EXTERI❑R LIGHTING FIXTURES AND 75% MIN w <br /> brace wall panels in the corners and every 25' O.C. Offsets 4' max. OF INTERIOR LIGHTING TO BE H�GH EFFICACY � <br /> R602.10.11 Structures in seismic Categories D1 & D2 shall be provided A PR�GRAMMABLE THERM�STAT IS REQUIRED <br /> with exterior & interior braced wall lines. Spacing between braced wall P❑ST ENERGY C�DE C❑MPLIANCE CERT, W/IN 3 FT � <br /> lines in each story shall not exceed 25' O.C. in both longitudinal and OF ELECTRICAL PANEL <br /> transverse directions. <br /> WH❑LE H❑USE FAN VENTILATI❑N RAT TRUSS ENGINEERING � <br /> PER IRC 2015 TABLE M1507,3,3 C1) & DESIGN ARE T❑ BE BY <br /> T <br /> FLO�R AREA BEDRODMS THE TRUSS MANUFACTURER <br /> SQ FT 0-1 2-3 4-5 6-7 >7 <br /> < isoo ao as eo �s 90 HIGH-EFFICIENCY LIGHTING <br /> isoi-3000 as bo �s 90 ios T❑ BE USED IN 75% ❑F <br /> 3001-4500 60 �s 90 ios i2o FIXTURES PER E-404,1 <br /> 4501-6000 75 90 105 120 135 <br /> RATES ABOVE ARE MIN OUTD�OR AIRFLOW IN CFM <br /> INTERMITTENT >25% IN 4 HR M1507,3,3(2 - <br /> RUN TIME% 25% 33% 50% 66% 75% 100% <br /> ��t�� �� ��������� <br /> FACT❑R 4 3 2 1,5 1,3 1 �������rE g ��� ,.��'�_�pi�f��� <br />