i.B.0 �ECTION 1011 REQUIRES THAT EXIT AND EXIT ACCESS �0"' MAXo 20"-25" MAX.
<br /> DOORS SHALL BE MARKED BY APPROVED EXI�" SIGN READILY
<br /> 9�,
<br /> � `VISIBLE FROM ANY DIREC710N OF EGRESS TRAVELo
<br /> v
<br /> MIN THE EXIT SIGNAGE IS REQUIRED TO HAVE A �iIGH CONTRAST
<br /> i
<br /> BACKGROUND WITH RAISED AND BRAILLE CHARACTERS. � WHITE � ; ;
<br /> � I.S.A ON A BLUE BACKGROUND SHALL BF iNCLUDED FOR � � '
<br /> � ! �
<br /> / ACCESSIBLE DOORS. ' �
<br /> � ' Z Q Q X z
<br /> , . , �-.
<br /> � ' � � � �Q O
<br /> H
<br /> SIGN #93A EXIT SIGNAGE SHALL BE MOUNTED ON THE WALL ON THE LATCH } . ; ��\ � - - � � � � � o � �
<br /> \� •�- VV `n � � � z w
<br /> SIDE OF THE DOOR WITH 18��X18" GROUND CLEARANCE O.C. IF � �'
<br /> � �' , ..,.
<br /> , ...�.. r, ,
<br /> �'"., t ... . .. ..�� ..: O �
<br /> � ADEQUATE ROOM IS NOT PROVIDED ON THE LATCH SIDE OF ` s �, A " � � `�
<br /> � ,;; '%� /;` >
<br /> o E� I T THE DOOR, THE SIGNAGE IS REQUIRED TO BE PROVIDED ON o '�` � '� �
<br /> - � cD �,•.■ THE NEAREST ADJACENT WALL. ao
<br /> n
<br /> EXIT DOOR SIGNAGE SHALL BE MOUNTED 60" A.F.F'. TO THE x (a) (b)
<br /> BOTTOM OF TEXT OR CHARACTERS. THE I.S.A. SIGNAGE SHALL X
<br /> BE MOUNTED IMMEDIATELY ABOVE THE SIGN. AT � 11NOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH
<br /> �VON-ACCESSIBLE ENTRANCES, DO NOT INCLUDE THE � FIGURE 308.2.1 FIGURE 308.2.2
<br /> N
<br /> lNTERNATIONAL SIGN OF ACCESSIBILITY. FORWARD REACH �
<br /> Q � � o � �
<br /> 0
<br /> IT IS RECOMMENDED THAT THE CENTER OF THE SIGN BE SET 1 o UNOBSTRUCTED. WHERE A FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 48" MAXIMUM AND THE LOW FORWARD
<br /> � TACTILE EXIT SIGNAGE NO CLOSER THAN 9" FROM THE FRAME OF A DOOR SO A REDUCED VERTICAL CLEARANCE REACH SHALL BE 15" MINIMUM ABOVE THE FLOOR. z � � � � �
<br /> � G2. � N.T.S. VISUALLY IMPAIRED USER WOULD BE OUTSIDE OF THE DOOR FIGURE 307.4 2. OBSTRUCTED HIGH REACH. WHERE A HIGH FORWARD REACH IS OVER AN OBSTRUCTION, THE CLEAR FLOOR SPACE SHALL EXTEND BENEATH THE SEAL
<br /> SWING WHILE STANDING IN FRONT OF THE SIGN. ELEMENT FOR A DISTANCE NOT LESS THAN THE REQUIRED REACH DEPTH OVER THE OBSTRUCTION.
<br /> 2.1. THE HIGH FORWARD REACH SHALL BE 48" MAXIMUM ABOVE THE FLOOR WHERE THE REACH DEPTH IS 20" MAXIMUM.
<br /> 4" MAX. ���� �
<br /> 2.2. WHERE THE REACH DEPTH EXCEEDS 20", THE FORWARD HIGH REACH SHALL BE 44" MAXIMUM ABOVE THE FLOOR, AND THE REACH DEPTH 7862
<br /> REGIST'ERED
<br /> H@aC'IC1gISp@@CIl- SHALL BE 25" MAXIMUM. A GFfii'EGT �
<br /> Impaired £3 ; „: ; 5 FORWARD REACH CLEARANCE �HA.DEFIL! PI
<br /> ATE 0�WASHIt�GTO
<br /> /�SSISta11C@ �' ' 12" MAX.
<br /> Available At This G2. 1 N.T.S.
<br /> - Window
<br /> »e Thank You
<br /> 10" MAX. >10"-24" MAX.
<br /> SIGN #778
<br /> m a Q
<br /> �
<br /> o Z w a N
<br /> OO Z Z � Qv-UW
<br /> nl � � O � W�Q�� �
<br /> X � � ���o==� a0
<br /> j i ; Q �W°_ F-v o r�
<br /> � � � ! LL v~w�¢a3z w
<br /> i� x CANE � � ! � �a3� �;a �
<br /> ONE SIGN SHOULD BE MOUNTED ON THE CASH AND PRESENT u � �—DETECTION ' W o��Z o�?=z �
<br /> Z�(nUF-2
<br /> W I N D O W W H E R E T H E R E W I L L A L S O B E P I C T U R E M E N U S A N D A x � � AREA � Z Q Q xQ � W����J�Q �
<br /> ��ow w
<br /> NOTEPAD AND PENCIL FOR THE CUSTOMER TO USE. THE EXACT N � � x � x � �v vo w>>z� v
<br /> � p � � � � � � � a._o�cno�o �
<br /> o MOUNTING LOCATION AND MOUNTING HEIGHT OF THIS SIGN IS % d- � �r
<br /> o NOT SPECIFIED BY THE ADA BUT SHOULD BE EASILY VISIBLE � M � v o��o � �
<br /> n; ;; �, � o
<br /> o FROM A CAR AT THE DRIVE-THRU WINDOW LIMITS OF PROTRUDING OBJECTS POST MOUNTED PROTRUDING OBJECTS vi � � ° � �
<br /> � FIGURE 307.2 FIGURE 307.3 (a) (b) ::� ..,,:: :......�: .-�- ......: .. � O � ��' 3 ~_
<br /> ° 2 SPEECH HEARING IMPARIED SIGN C� DT
<br /> � 3a;3 � �
<br /> g -
<br /> � � � L O W W
<br /> �� �a� �b� J �, � a Z
<br /> o `� � " ��
<br /> a G2. 1 N.T.S. � _ �
<br /> 10 MAX.
<br /> � m a � W
<br /> c � �
<br /> N � �3a � x
<br /> `- UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH N ° = F W
<br /> � 1. OVERHANG OBSTRUCTIONS. ANY OBSTRUCTION THAT OVERHANGS A ROUTE BY WHICH A PERSON MAY PASS IS � w N � o Z
<br /> GRAPHICS SHOWN ARE FOR REFERENCE ONLY. FIGURE 308.3.1 FIGURE 308.3.2 p o �
<br /> o R E Q U I R E D T O B E A T L E A S T 8 0 I N C H E S A B O V E T H E W A L K I N G S U R F A C E A S M E A S U R E D T O T H E B O T T O M O F T H E
<br /> . N �GC TO PROVIDE ADA SIGNAGE PACK/�GE AND INSTALL SIGNS OBSTRUCTION SIDE REACH
<br /> AT LOCATIONS AND POSITIONS INDICATED IN PACKAGE OR AS
<br /> �' REQUIRED BY LOCAL CODES. SIGNAGE PACKAGE SUPPLIED BY: 1. UNOBSTRUCTED. WHERE A CLEAR FLOOR SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE EDGE OF THE CLEAR FLOOR SPACE IS
<br /> r- ,, VARIES � 2. PROTRUDING OBJECTS.
<br /> � FORREST PERMA-SIGN 10"' MAXIMUM FROM THE ELEMENT, THE HIGH SIDE REACH SHALL BE 48" MAXIMUM AND THE LOW SIDE REACH SHALL BE 15" MINIMUM ABOVE
<br /> ° - R00 M NAM E s2s2 1ST ST.y eox 5ss
<br /> � N F}y- �•-y NEW ROCHELLE, NY 10802 2.a. OBJECTS WITH THEIR LEADING EDGES BETWEEN 27"� AND 80" A�OVE THE FINISHED FLOOR OR GROUND SHALL THE FLOOR.
<br /> °' SIGN g" www.forrestpermasigns.com „ 2. OBSTRUCTED HIGH REACH. WHERE A CLEAR FLOOR SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT, THE HEIGHT OF THE OBSTRUCTION
<br /> � 6 MIN. ��, 1-800-214-8765 PROTRUDE 4 MAXIMUM HORIZONTALLY INTO THE CIRCULATION.
<br /> SHALL BE 34" MAXIMUM ABOVE THE FLOOR AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24" MAXIMUM.
<br /> � • • � �. SIGNAGE NOTES: 2.b. FREE STANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAY OVERHANG 12" �IAXIMUM WHEN LOCATED 27"
<br /> � ^ DOOR ,� 1. EACH EXIT DOOR SHALL HAVE A TACTILE SIGN, INCLUDING ,y 2.1. THE HIGH SIDE REACH SHALL BE 48" MAXIMUM ABOVE THE FLOOR FOR A REACH DEPTH OF 10" MAXIMUM.
<br /> o � _ � MINIMUM AND 80 MAXIMUM ABOVE THE FINISHED FLOOR OR GROUND.
<br /> � � o � RAISED LETTERS AND BRAILLE, STATING 'EXIT' AND SHALL 2.2. WHERE THE REACH DEPTH EXCEEDS 10"9 THE HIGH SIDE REACH SHALL BE 46" MAXIMUM ABOVE THE FLOOR FOR A REACH DEPTH OF 24"
<br /> I COMPLY WITH CHAPTER 7. ALL SIGNAGE SHALL CONFORM
<br /> � a� WITH ACCESSIBILITY GUIDELINES AND LOCAL GUIDELINES MAXIMUM.
<br /> ' WOMEN ` INCLUDING BUT NOT LIMITED TO PROPORTION, COLOR
<br /> �o ,>.�� -� � J � W
<br /> a J Q � � CONTRAST AND RELIEF AND GRADE 2 BRAILLE REQUIREMENTS. 5 OBSTRUCTIONS 6 SIDE REACH CLEARANCE o
<br /> +, � Q MOUNTING ~ �
<br /> / z m Q � ELEVATION 2• WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS G2 ,� ¢ �
<br /> cv � � � � AND SPACES, RAISED LETTERS SHALL BE PROVIDED AND N.T.S. G2• � N.T.S. �
<br /> j. w o a SHALL BE ACCOMPANIED BY BRAILLE IN CONFORMANCE WITH N
<br /> m � o CHAPTER 7. SIGNS SHALL BE INSTALLED ON THE WALL z �
<br /> o � 0° `° ~ ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE j
<br /> c� SECTION 4.6.4 OF THE ADAAS STANDARDS REQUIRES EACH ACCESSIBLE ORDER STATION �
<br /> � IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT � �
<br /> DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE PARKING SPACE TO BE IDENTIFIED WITH VERTICAL SIGNAGE. o ,
<br /> � NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. a �
<br /> W MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISHED � SIGN 141 THE SIGN DESIGNATING THE PARKING SPACE AS ACCESSIBLE MUST DEPICT �
<br /> � FLOOR TO THE CENTERLINE OF THE SIGN. MOUNTING #
<br /> - �� 3 RESTROOM SIGNAGE LOCATION SHALL BE�� DEfERMINED SO THAT A PERSON MAY � PARKING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY(ISA). THE SIGN MUST ALSO w j
<br /> o APPROACH WITHIN 3 OF SIGNAGE WITHOUT ENCOUNTERING � SIGN USE TEXT TO IDENTIFY THE SPACE AS RESERVED. Customers With Speech � w
<br /> G2. 1 N.T.S. PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A �px Or Hearing Difficulties Q
<br /> z DOOR, ACCESSIBIE SIGN #343 IT IS RECOMMENDED THAT THE U.S. DEPARTMENT OF TRANSPORTATION w
<br /> cn • Please Pull Up To The z >
<br /> Z� S100fINEFOR STANDARD R 7-8 SIGN BE MOUNTED IN FRONT OF AND CENTERED ON THE Next Open Window For Q � Q
<br /> Assistance in Orderin � >-
<br /> � ACCEPTABLE MOUNTING LOCATIONS �,o�T,oN sic►v �42 ThankYou J
<br /> °' xQ PARKING SPACE. g Q � �p
<br /> � RESERVED Z o STATE AND LOCAL CODES MAY HAVE VARING REQUIREMENTS SOME STA7E SIGN #7797 Q z o
<br /> j ADJACENT WALL c, � � U
<br /> We WIII B@ � N OR LOCAL CODES REQUIRE AN ADDITIONAL SIGN THAT INDICATES A FINE w � O
<br /> ^ Pleased To Help PARKING � o , AMOUNT PARKING IN THE RESERVED SPACE WITHOUT PARKING REGISTRATION �`a=�� w U �
<br /> � Any Customer � W ; � � %
<br /> � Needing Assistance. � � � O !;�' '/ / FINE AMOUNT MAY VARYa �'7 � d"
<br /> � •
<br /> � o PLEASEASKAT m � ` i� � EACH VAN ACCESSIBLE PARKING AISLE IS ALSO REQUIRED TO BE IDENTIFIED � a � o
<br /> � C O U NT E R o � � /'/��' �/ � v WITH SIGN WITH THE TEXT, "VAN ACCESSIBLE" MOUNTED BELOW T H E I S A. °' N � �
<br /> � / _ � o o �
<br /> 3 SIGN #1002 V A H z � // / � cn IT IS REQUIRED THAT A SIGN BE USED TO DESIGNATE EACH VAN � m
<br /> = ACCESSIBLE � �
<br /> 0 0 � �. ,� J Y ACCESSIBLE PARKING SPACE. � o o �
<br /> z w / / � Ln
<br /> o � p i��/' /`� J � THE VERTICAL SIGNAGE IS REQUIRED TO REMAIN VISIBLE WITH A VEHICLE Z w �
<br /> � ��/ ' � f �` �
<br /> � _ $1OO FIHE FOR ,,, : PARKED IN THE SPACE. � O Q } � O
<br /> c ONE STAFF ASSISTANCE SIGN SHOULD BE PROVIDED AT �� � •: �
<br /> �v�� S E L F S E R V E VIOLATION ��� ' I T I S R E C O M M E N D E D T H A T T H E B O T T O M E D G E O F T H E L O W E S T A D A A S W Z w m Q �
<br /> '� EACH-SELF SERVE AREA. THIS SIGN MUST BE MOUNTED IF AN i, � �:
<br /> o BEVERAGE BAR „ 'J � ' REQUIRED SIGN BE MOUNTED AT 60" ABOVE FINISH GRADE. THE PARKING N ~ v�'i m � o
<br /> /� ITEM ON THE SELF-SERVE BAR IS HIGHER THAN 48 FROM THE w - z � � ��,
<br /> ' o FLOOR OR MORE THAN 20" BACK FROM THE EDGE OF THE 60" MIN. SIGNAGE MAY ALSO BE MOUNTED ON A WALL OR BUILDING. � ¢ � �'�' z ��
<br /> ONE INFORMATIONAL SIGN SHOULD BE MOUNTED AT EACH CUSTOMER
<br /> o° TRAY RAIL. THE SIGN MUST BE LOCATED TO BE EASILY SEEN IT IS RECOMMENDED THAT THE HORIZONTAL DIMENSION FROM THE SIGN ORDER STATION TO PROVIDE DIRECTION FOR HEARING AND SPEECH � � � �
<br /> U �"3
<br /> � BY ALL CUSTOMERS. MOUNTING LOCATION IS NOT SPECIFIED BY PLACEMENT TO THE FRONT OF THE SPACE BE 60" OR LESS. IF THE SIGN IMPAIRED CUSTOMERS. THE MOUNTING LOCATIONS OF THIS SIGN IS NOT SHEET NUMBER ��
<br /> /� ELEVATION TYPICAL SITE PLAN
<br /> � THE A.D.A. IS LOCATED WHERE f7 COULD BE DAMAGED BY VEHICLES, A BOLLARD OR �PECIFIED BY THE ADA.
<br /> a� �
<br /> OTHER PROTECTION IS RECOMMENDED. ��
<br /> � 4 STAFF ,�SSISTANCE SIGNAGE � ACCESSIBLE PARKING SIGNAGE 8 SPEECH HEARING IMPAIRED SIGN C� C.O.D. r G�
<br /> ...��.. , ,..�...
<br /> G2. � NoT.s. �' � �" �'�`�'" Architecture �`=
<br /> �������� ��� ������ �
<br /> ° G2. 1 N.T.S. G2. 1
<br /> .� N.T.S.
<br /> � ;
<br /> � �s
<br /> �
<br />
|