<br /> 1�- PROVIDE NEW 120V, NEMA 5-20R 4—PLEX RECEPTACLE. 1 . CONDUIT: 3/4" EMT UNLESS NOTED OTHERWISE. �
<br /> MOUNT RECEPTACLE WHERE ACCESSIBLE FROM HATCH CONDUIT BELOW 6' AFF TO BE GALVANIZED RIGID STEEL. �'
<br /> ABOVE.
<br /> 2. CONDUCTORS SHOWN: �12 AWG, STRANDED COPPER, �
<br /> � PROVIDE NEW BUSPLUG OF AMPERAGE AND NUMBER OF INSULATION TYPE THHN/THWN, UNLESS OTHERWISE �
<br /> POLES INDICATED. BUSPLUG TO BE MOUNTED WITH NOTED.
<br /> �� �� r- MINIMUM 42° CLEARANCE TO GROUNDED PARTS. \ �� :t�v4
<br /> 9
<br /> � , � ' C� ' � , � 1 1 1 1 3• COLOR CODE CONDUCTORS: IDENTIF`( CONDUCTORS `�
<br /> WHICH DO NOT HAVE APPROPRIATELY COLORED
<br /> \�� \ 3� PROVIDE 480 - 120V, SINGLE PNASE, 3KVA INSULATION WITH COLOR TAPE WHEREVER
<br /> TRANSFORMER, ACME �T-2-53013-4S OR EQUIVALENT. CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED �
<br /> PROVIDE CONDUIT AND CONDUCTORS TO PANEL GROUND CONDUCTORS PER NEC 250-119.
<br /> XE3V24-4BUK10.5/1 a AS INDICATED. PROVIDE ADJACENT COLOR CODE AS FOLLOWS: �
<br /> I I � � ENCLOSED BREAKER AND FEED FROM SECONDARY OF �'
<br /> TRANSFORMER VIA 3/4"C, 2�10, 1 �10G, FOR USE BY 208Y 120V 480Y 277V
<br /> MID-MCS RECEPTACLE. A � (LEFT BUS IN PNL) BLACK BROWN
<br /> B � CENTER BUS IN PNL) RED ORANGE . �
<br /> � C � �RIGHT BUS IN PNL) BLUE YELLOW ,..;
<br /> 4�j ADJUST BUS LENGTH AND RECONNECT TO SOURCE AS � NEUTRAL WHITE GRAY �� �': '
<br /> NECESSARY TO WSTALL 480V CONTACTORS AS SHOWN ON � EQUIPMENT GROUND GREEN GREEN °
<br /> ^ ^ � �����-��r�� ,� ISOLATED GROUND GRN/YEL* GRN/YEL*
<br /> --- -- -- -- -- --- -- -- -- - -- - -- -- , --- -- -- -- -- �
<br /> ��}� IINF �
<br /> I , , , ; � . _ -----= __ ___ .__� ,- � _ *GREEN WITH YELLOW TRACER .
<br /> -- --� --- -----_-
<br /> � SEE SHT. TNE69 �
<br /> i ; ! , � �
<br /> , ; 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX
<br /> �, i , '; , � � A N D S W I T C H W I T H C I R C U I T I D E N T I F I C A T I O N.
<br /> .,
<br /> , ,
<br /> I � � , '� , �
<br /> ,� ,______J , r____ � , � 5. POST NEW OR REVISED PANEL SCHEDULES UPON
<br /> ; � �
<br /> , , . ,
<br /> ,;�.�.. ,_,, �-----_--- ______--�-, �, .�,� .
<br /> ------=' i ,- - , `---- �-,y '; � COMPLETION 0F JOB. �
<br /> �— !- --- --1 a - � � � _ Wp � � 6. UPON COMPLETION OF JOB RETURN REDLINES TO �
<br /> � .
<br /> r,y
<br /> . ,
<br /> � .
<br /> ---- ----- _-__ _-- r
<br /> � � � � 7� THE MOBILE CONTAINMENT SYSTEM (MCS) TOOL PROVIDED ,
<br /> ! � SEE SHEET E521 FOR BURIED � TO BOEING BY GIFFIN, INC. AND REFERENCED ON THESE
<br /> I CONDUIT IN THIS AREA. I _ __ - , DRAWINGS HAS BEEN DESIGNED, CONSTRUCTED AND 3RD
<br /> XE3V24-46UK10.5/1a � _ _ __ _ __ __ __ __ _ _
<br /> � - - - - - -- -- - PARTY EVALUATED FOR INSTALLATION IN A NON-CLASSIFIED
<br /> 3/4"C, 2#12 & 1�12GND �
<br /> � 225A 208Y 120V, 3�, 4W , I 1 LOCATION. THIS TOOL SHALL HAVE A BARRIER INSTALLED
<br /> .;
<br /> � � AND MAINTAINED DURING OPERATIONS THROUGHOUT THIS
<br /> - ' TOOL'S LIFECYCLE TO MITIGATE THE POTENTIAL FOR SPRAY
<br /> , I I �.
<br /> , VAPOR ASSOCIATED WITH THIS TOOL TO MIGRATE INTO
<br /> , �
<br /> � - ; 2V24-2BTNL10A , .�
<br /> .
<br /> ' �; 2V24-2BUK i10.5-D/2 XE3V24-4BUK10.5/1 a ___ ___ __ _ __ 2V24-2AL10.5 -15 - ' -- -- - NON-CLASSIFIED AREAS WHERE NON-RATED ELECTRICAL �
<br /> , : .
<br /> � 3 C,(4)250k mil 3/4"C, 2�12, 1�12G ; - - 1/2"C,2�1 Q '" ; ; - I EQUIPMENT MAY BE LOCATED. THE BARRIER CONSTRUCTION ,. ' '�
<br /> � � � �. � r '�� '
<br /> : ''., � SHALL HAVE THE FOLLOWING CHARACTERISTICS: ' �
<br /> �
<br /> �, .,
<br /> ', MP CO__NTROL , '
<br /> � END TAP
<br /> � ' ' BOX 225A 3 SUM PU '
<br /> I � BARRIER SHALL EXTEND OUTWARD LIKELY
<br /> � ' _ __ _--- --___ _--- - --- ___ __2 __ __ _ __-- - __ --- -- --- - . ---_ ._ __ i '' PAN L. ; , , ' . � � • ,
<br /> ---- ------------- ------------_� ----__ ;_-- - ---
<br /> -- -----___ ____ _._- ----__------ � __. ----- ____ _ ____ __ _ . _ b I PERPENDICULAR, FROM THE SURFACE OF THE �
<br /> ;
<br /> ---- �� - ------ --_- --- ---_ __ ____ ____ _.__.___ EQUIPMENT TO A MINIMUM OF THREE FEET. �
<br /> 20 � � N �, �, _ __ 1/3HP, 120V, a , ' _ -__ : .
<br /> 3 20-1P � � � � SUM UM - � I
<br /> 9
<br /> 0 0 o a 4 --- � • BARRIER SHALL BE MADE OF STEEL WITH AIR TIGHT
<br /> �, �, �, , _ _-- --___ -- _- -- -_ __ ___- -__ __ _ ----- __ __ __ _. _ _ __ _ _ , SEAMS.
<br /> _.. _- --- - --- -- --- ___ _.
<br /> --- _ ---- ---- - --- - __ _ -_ _- - ____ ___- ___ _ _ -- __- ---- __ _-- ---- _ - -- --- ----- ___ __- -_ - - _ _
<br /> I ---- _ _ ____._ ---- ____ _._ ____ _ _.. _._-- ___ ___ _- I --- __. _- ---- __ __ - � � i • SPACES BETWEEN THE BARRIER AND THE EQUIPMENT,
<br /> I ' ' I AS WELL AS THE BARRIER AND THE FLOOR, SHALL BE ,
<br /> � � SEALED AIR TIGHT TO PREVENT SPRAY VAPOR �
<br /> /� I TRANSMISSION. � �r�•,h •
<br /> ; TNE74 E528
<br /> , , , -
<br /> �
<br /> . ' _'_ � , �
<br /> I � � � �
<br /> �
<br /> I � I __---- I �
<br /> __, ' ; ( , - �`
<br /> , , , , ,
<br /> , ;
<br /> � ,
<br /> b _ _ _ _ _ _ --- - �
<br /> � , � , ,
<br /> ,
<br /> 1 ' �
<br /> - _ - ___ __ .
<br /> I ; C , ; I .
<br /> I
<br /> , ,
<br /> c
<br /> � �yp ._ -- -_ __ ____ _ __-- _ _, , _ ---- _ _ _ __ -_ -___ __ __ _ _ _ __ __ _ __ ,.
<br /> ;( ) _ -- ___ - .
<br /> � , � :`
<br /> ---- ----- -_ __ --__ --_--- - __- ---- . , , ? .
<br /> ,
<br /> _ _ _ _ _ - -_-- -_ _--- -- -_ ___ ._ -- - --_ --- _. _._ _ -- __ _ ___ __ ___ __ _ --__ . ..
<br /> l � .
<br /> � Wp 9b ___ __ _I - ------- ---- __ - - - -- _. _ __ _ __ - _ __ __ ___ __. ____ --- ____ ___. ,
<br /> I
<br /> � I
<br /> I , , � 1, ',, �� . � .
<br /> � ! ' � ' ,' ', �
<br /> � ; SEE SHT. TNE24 ,
<br /> FOR CONTINUATION (TYP.) , � 3 5 7 9 �t �
<br /> , ' 0.9 11'
<br /> � , ' � B DG 40 24 K
<br /> I ,
<br /> , ' K :t
<br /> I .
<br /> I
<br /> I �
<br /> { i '; �, � �, , TNE6� TNE61 TNE62 TNE63 TNE64 � <', �
<br /> � , � a � c , �
<br /> - - ---
<br /> _- --. � , � ; , TNE65 TNE66 TNE67 TNE68 TNE69 �n �.
<br /> � , � � ,�
<br /> ,
<br /> � L.3 �
<br /> - -- -- ; b
<br /> ,, .
<br /> �_ __ __ —, �
<br /> 3 !-_
<br /> � TNE70 TNE71 TNE72 TNE73 NE74 �r >
<br /> , _. I .
<br /> I � � L.7 C.�
<br /> I o •�
<br /> I TNE75 TNE76 TNE77 TNE78 TNE79 —�
<br /> ; ,
<br /> m .
<br /> M
<br /> � ,�, I , ' I I TN E80 TN E81 TN E82 TN E83 TN E84 N
<br /> z , ,
<br /> J i I �' .
<br /> • r .
<br /> � `�j' ' ' � BLDG 40-26 �
<br /> Q
<br /> �
<br /> � � KEY PLAN .
<br /> -- --- --- -- -- -- -- -- -- -- -- -- -- � SCALE: NONE Q .
<br /> . �� �� . �� �� �� . . �� . _ . . � . . . . •t
<br /> .._.... ..._.._._..._
<br /> _.__..� � . . .
<br /> ..... . ..... .� . . . ^
<br /> , � __ � __ , � , . -l__ p ° , 8' 4' 0 4' 8 16
<br /> i --- — — —=� i� — — -- — — — ' i _ — — -- — — —=i` � — — _ _ — — �e �
<br /> — — — _. , — . o
<br /> � � i ��� � � ..
<br /> , MATCH LINE ° , � SCALE: 1/8" = 1 '-0" �
<br /> '___ '---=- _____� ! `
<br /> ________
<br /> SEE SHT. TNE79 . �t �
<br /> � r ,
<br /> T U �1 E� �E�E L 2 0 8Y 12 0� P 0 W E R P �A N ,�,.brph.com Copyright o 2019 �
<br /> PARTIAL N Architects Engineers, �n�. �'
<br /> SCALE: � 8"=1 �—Q�� � Ce�'fica e of Au9horization •
<br /> / 19020 33rd Ave W,Suite 530
<br /> Lynnwood,Washington,98036 Architecture No.603235512
<br /> 425-921-3500 Engineering Na.3137
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE • :�
<br /> �°REST C�� HSC ESGN BND/R HBCKED 04 26 19 PARTIAL TUNNEL LEVEL 208Y/120V POWER PLAN � s322 � 04/26/19 .. �r�.• ,
<br /> 0 RR1 — WBJ Perm MCS — P3 — I�sue For Construction WBS16322 BLB DFC 02/25/19 .y�' ��°� wAsH��c�,`��,�, SPECIFICATION IS APPROVED BLB 04 26 19 sHE� �
<br /> 1 RR3 — WBJ Perm MCS — P3 — Revision Perm MCS (WBS16322) BLB DFC 04/26/19 �0���� � � �� �, `f APPROVED BY DEPT. DATE pFC 04 26 1g T�r�E FACTORY TRANSFORMATION — 777x Wing Body Join _
<br /> , �HE�KEo T N E 74 82 5
<br /> "� 5z�sa ww� APPROVED B U I L D I N G 4 0�0�� JOB N0. COMP N0. . '
<br /> �°� '��cisTER�� �� WO 15/2899-825
<br /> `�ssroNAL ��' APPROVED ELECTRICAL MASTER COL L.3—L.7/9-11 EVERETT, Wq °wc rvo. 40-025—TNE74-825
<br /> :;