Laserfiche WebLink
,'il.' . . � .... .. . . . . . . . . :. - ' • . <br /> � U N IT KEYED NOTES Architecture <br /> &Consulting <br /> WOOD CONSTRUCTI ON (CARPENTRY) � REPLACE SELECT NON-LOAD BEARING FRAMING AT UN(T B-10 BEDROOM 2 ONLY W/ 2X4 FRAMING C� 16"O.C. PROVIDE - <br /> PRESSURE-TREATED SiLL PLATE 1F NECESSARY. SEE WALL TYPE'A'ON SHEET A6.3. <br /> NOTE: THIS IS A LIKE-FOR-LIKE REPLACEMENT. <br /> 1. EACH PIECE OF LUMBER SHALL BEAR THE STAMP OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB) OR WESTERN WOOD ____. ^ - - - - --. - - DECK LEGEND: / � ' <br /> PRODUCTS ASSOCIATION (WWPA) SHOWING GRADE MARK OR APPROVED EQUAL. BEAMS AND POSTS TO BE FREE OF HEART (E) HEADER = = <br /> I� o00o O2 SEAL EXISTING STUD FRAMING FOR ODOR CONTROL(PRODUCT SHALL BE ESQS COMPLIANT). 2130 FOU RTH ST <br /> CENTER (FOHC). OTHER MATERIALS SHALL BE AS SHOWN BELOW: II 47 17 21 23 I STORAGE 2 <br /> I I �3 SEAL EXISTING FLOOR/CEILING JOIST FOR ODOR CONTROL(PRODUCT SHALL BE ESDS COMPLIANT). SAN RAFAEL, CA 94901 <br /> � PHONE (415) 457 6035 . <br /> SAWN LUMBER MEMBER SPECfES AND MINIMUM GRADE Fb(PSI) F,,(PSf} E (PSI) ii 13 16 (E) HEADER O REMOVE AND REPLACE BATT INSULATION WITH 4"R-11. . <br /> 6X POSTS DOUGLAS FIR - #1 1200 170 1.6x106 �� � `� 51 � REMOVE AND REPLAC BATT INSULATION WITH 4"R•19. AT FLOOR/CEILING . P•�. BOX 150539 <br /> 6X BEAMS DOUGLAS FIR - #1 1350 170 9.6x106 I II BEDROOM 1 f � -: O � } SAN RAFAEL, CA 94915 <br /> 4X POST$ & BEAMS DOUGLAS FIR -#T 1000 180 1.7x106 I I� 38 14 �2 O7 �8 10 I � O CO OVS E WALL TYPE DETAILS'A'AND'B'ON SH ET A6.D3 FOR CONSTRUCTIONPE,TEXTURE,APPLY PVA PRIMER, ONE <br /> II LEGEND: <br /> 2X JOISTS, RAFTERS DOUGLAS FIR • #2 900 180 1.6x10b I� 40 I � � _ ,.� _ _ %$'REGULAR <br /> PL MATERIAL DOUGLAS FIR- #2 900 180 1.6x106 � � 39 _ _ _ %$'"TYPE X"MOISTURE RESISTANT <br /> 2X STUDS DOUGLAS FIR-#2 900 180 1.6x1Q5 ��H O � <br /> 34 � � � <br /> I � � PAINT WALL CORNER TO CORNER, TWO COATS. MATCH PROPERTY STANDARD. , <br /> i LIVING I O <br /> - - - - - ROOM � : CHARLES PICK ARCHITECT <br /> � � �� 14 ( O PAINT CEILING CORNER TO CORNER, TWO COATS.MATCH PROPERTY STANDARD. � ` <br /> 2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ASSURE THAT TNE MAXIMUM MOISTURE CONTENT OF WOOD AT THE �� 3 OO O� 21 ! � , <br /> � REMOVE AND REPLACE RESILIENT PLANK FLOORING, PROPERLY PREPARE SUBSTRATE FOR NEW FLOORING. MATCH <br /> TIME OF INSTALLATION SHALL BE NOT MORE THAN 14%. ( � 38 II 46 ' � ;; O PROPERTY STANDARD. PROVIDE METAL TRANSITION STRIP AT FLOORING CNANGES. � <br /> 3. NAILS TO BE OF COMMON WIRE AND OF FULL-ROUND HEADS WHERE NAILING IS SPECIFIED ON THE DRAWINGS. MACHINE-DRIVEN II ' <br /> 10 REMOVE AND REPLACE CARPET AND PAD AT LIVING ROOM, HALLWAY, AND BEDROOMS.MATCH PROPERTY STANDARD. 9252 <br /> - NAILS MEETING SIZE REQUIREMENTS ARE ACCEPTABLE. NAILS MUST NOT BE OVER-DRNEN. PRE-DRILL NAIL HOLES WHERE WOOD I W 14 II I I � I I O REGISTERED <br /> TENDS TO SPLIT. NAILS AS SPECIFIED ON PLANS AND INCLUDING iN PTDF MATERIAL CONTAINING AMMONIA IN EXTERIOR o O II � I 11 REMOVE AND REPLACE 4"COVE BASEBOARD.MATCH PROPERTY STANDARD. ARC ITECT <br /> APPLICATIONS SHALL BE TYPE 304 OR 316 STAINLESS STEEL. NAILS USED IN EXTERI�R APPLICATIONS OR IN INTERIOR PTDF SHALL = BEDROOM 2 � � c�� <br /> BE HOT- DIPPED GALVANIZED PER ASTM A153. I W __ __ � � 1z REMQVE AND REPLACE EXTERIOR ENTRY DOOR, INSULATED 6-PANEL. REMOVE AND REPLACE DOOR LOCKSET AND � <br /> -- �2 �7 �8 1 0 � � 4b � `. O D E A D B O L T. P R O V I D E D O O R S T O P A T I N T E R I O R(W A L L O R F L O O R M O U N T E D). M A T C H P R O P E R T Y S T A N D A R D. CHARLES I I' C K <br /> ( 17 21 23 34 I I CPT CPT � SEE DOOR SCHEDULE ON SHEET A5.0. STATE OF WASHINGTON <br /> WIRE NAIL MI�fIMUM SHANK DIAMETER MINIMUM NA[L LENGTH TYPICAL NAIL APPUCATION 2 • � <br /> 16d COMMON 0.162" 3 2' FRAMING I 14 ' �SL CPT �� �� � 13 SCHEDU E ON HEEfCA5AYEXISTING HEADERTO RE/vlp�N DUAL PANE GLASS. MATCH PROPERTY STANDARD. SEE DOOR <br /> 9 � O �� O � EXPIRATION DATE:6/18/20Z1 <br /> 16d SWKER 0.148" 3 4' FRAMING 3 4fs � I)� RSL RSL I . . . 14 REMOV�AND REPLACE INTERIOR DOOR, HARDWARE.MATCH PROPERTY STANDARD. SEE DOOR SCHEDULE ON SHEET <br /> � ___ O I O� � A 5.0. E X I S T I N G H E A D E R T O R E M A I N. . <br /> 10d COMMON 0.148" 3" FRAMING ' <br /> 10d COMMON 0.148" 2 2' SHEATHING � _ _ _ _ _ - o000o I . 15 W NDOW CHEDU ECON SHEET A5�'0 EXIST�IN�G H A ER TO REMAIN�EX EPT�WHERE NOTEDOON PLANSANDARD. SEE � <br /> � <br /> 38 � 10 19 34 35 �PT � DINING O I ..: ' <br /> ' 8d COMMON 0.131" 2 Z' SHEATHING �O� O 7 , . ' <br /> � O�� ,� �_- `_J 1 6 R E M O V E A N D R E P L A C E W I N D O W V E R T I C A L B LI NDS, 3.5"P VC. M ATCH PROPERTY STANDARD. <br /> 3 __ I 11 I �� REMOVE AND REPLACE WINDOW MIM BLINDS, 1"PVC. MATCM PROPERTY STANDARD. L EGEND : <br /> 4. METAL FRAMING CLIPS, HANGERS, ETC. ARE BY SIMPSON STRONGTIE. NAILING SHALL BE IN ACCORDANCE WITH THE � q6 O � ., : <br /> MANUFACTURER'S INSTRUCTIONS WITH A NAIL PROVIDED FOR EACH PUNCHED HOLE UNO. CONNECTORS AS SPEGFIED ON PLANS I 14 � RS�- 3 � ; 1g REMOVE AND REPLACE HOUSE ADDRESS.MATCH PROPERTY STANDARD. (E)WALL TO REMA�N <br /> AND THOSE IN CONTACT WiTH PTDF MATERIAL CONTAINING AMMONIA IN EXTERfOR APPLICATIONS SHALL BE TYPE 304 OR 316 O � 9 � 4� --� � � , . REMovE AND�EP�Ace uGHr FixTURE, ENERGY STAR CERTIFIED. MATCH PROPERTY STANDARD. . <br /> STAINLESS STEEL. ALL OTNER CONNECTORS USED IN EXTERIOR APPLICATIONS OR INTERIOR PTDF SHALL BE HDG (MINIMUM 2.0 � _ _ _ <br /> OZ/SQ FT) OR ZMAX (MINIMUM 1.85 QZ/SQ FT PER ASTM A653j. IN APPLICATIONS WHERE NON-AMMONIA TREATED WOOD IS DRY � 14 4b � ' r f 31 ` � 12 i ; . 19 _ _ _ (E)WALL TO BE REMOVED <br /> WHEN INSTALLED ANQ WILL REMAIN DRY IN-SERVICE A COATING THICKNESS OF 0.9 OZlSQ FT MAY BE USED. I I � 32 ( � � �C� , ,_, 20 REMOVE AND REPLACE CEILING FAN AND LIGHT, ENERGY STAR CERTIFIED. MATCH PROPERTY STANDARD. <br /> ( BEDROOM 3 � BATH , I � Q O� , C 1 > ' O <br /> 5. WOOD SCREWS SHALL CONFORM TO ANSI/ASME B18.6.1. PROVIDE PILOT HOLE 70%OF DIAMETER OF SCREW SHANK WHERE � �2 O7 �8 �0 � 42 45 I 26 29 I __��__ Z� REMOYE AND REPLACE THERMOSTAT. ��/T�Ti,i�T/T/� (N) INTERIOR PARTITION <br /> FASTENING HARDWOOD TIMBER SPEC(ES OR WNERE WOOD TENDS TO SPLIT. MINIMUM PENETRATION IS (10) DIAMETERS, UN0. I 17 21 23 I i 41 ' ; �o KITCH9N I � �18 14 2z REMOVE AND REPLACE BASEBOARD HEATER. 8'LENGTH. ' <br /> � O ���� 1 HOUR RATED WALL <br /> 6. BOLTS SHALL BE UNFINISHED MACHINE BOLTS PER ASTM A307. NUTS SHALL BE PER ASTM A563 AND OF STANDARD SIZE UNLESS � � , � � � 2g REMOVE AND REPLACE BASEBOARD HEATER. 4'LENGTH. <br /> , NOTED OTHERWISE. LENGTH OF BOLTS SHALL BE SUCH THAT THE BOLT PROJECTION IS NOT LESS THAN'ENOR MORE THAy I" ! 43 , I � 28 OO �'J 3 I <br /> PAST END OF NUT. BOLT HOLES IN WOOD SHALL B��'LARGER THAN BOLT SIZES (UNO). PROVIDE STANDARD CUT WASHERS � _ (E) HEADER _ � � _ ! � ' � O8 24 REMOVE AND REPLACE BASEBOARD HEATER. 3'LENGTH. <br /> UNDER HEAD AND NUT WHERE BOLT HEADS WOULD BEAR ON WOOD. USE MALLEABLE 1RON WASHERS WHERE EXPOSED TO VIEW _ _ __ <br /> OR NOTED. NUTS SHALL BE TIGHTENED WHEN PLACED AND RETIGHTENED BEFORE CLOSING IN OF WALLS OR OTHER 25 REMOVE AND REPLACE KITCHEN SINK, SINGLE BASIN. REMOVE AND REPLACE KITCHEN FAUCET WITH WATERSENSE <br /> CONSTRUCT►ON. DO NOT CRUSH WOOD WHEN TIGHTENING. BOLTS AS SPECIFIED ON PLANS AND THOSE IN CONTACT WITH PTDF O » CERTIFIED FIXTURE.MATCH PROPERTY STANDARD. � <br /> MATERIAL CONTAINING AMMONIA IN EXTERIOR APPL(CATIONS SHALL BE TYPE 3Q4 OR 316 STAINLESS STEEL. ALL OTHER BOLTS <br /> USED IN EXTERIOR APPLICATIONS SHALL BE HOT-DIPPED GALVANIZED PER ASTM A153. 26 REMOVE AND REPLACE GARBAGE DISPOSER. MATCH PROPERTY STANDARD. <br /> 7, WOOD AGAINST CMU OR CONCRETE SNALL BE PRESSURE TREATED DOUGLAS FIR (PTDF) PER AWPA STANDARD U1. "USE 27 RESERVED <br /> CATEGORY" UC2 AT INTERfOR. "USE CATEGORY" UC3B AT EXTERIOR (NO GROUND CONTACT). CUT FACES SHALL BE BRUSH U 1 `I I T ��O / - 3 B E D/ 1 �AT H (U P P E R U N I T) o <br /> TREATED WITN EQUIVALENT PRESERVATIVE PRIOR TO INSTALLATION. 28 REMOVE AND REPLACE DISHWASHER. <br /> SCALE: 1/4"= 1'-0" 29 REMOVE AND REPLACE REFRIGERATOR, ENERGY STAR CERTIFIED.MATCH PROPERTY STANDARD. <br /> 8. WOOD ADHESNE SHALL 6E WATER-PROOF, CARTR(DGE DISPENSED, MEETING APA PRODUGT SPECIF{CATION AFG-01 OR ASTM <br /> D3498. LOCTITE "PL PREMfUM" OR EQUAL. FOR USE AT SUBFLOOR SHEATHING AND WHERE SPECIFICALLY NOTED FOR USE ON 30 REMOVE ANO REPLACE 30"ELECTRIC RANGE, FREE-STANDING. REMOVE AND REPLACE RANGE HOOD.MATCH PROPERTY DRAWING REVISION LOG � <br /> DRAWINGS. <br /> STANDARD. <br /> 9. ANCHOR RODS SHALL BE ASTM F1554 GR36 OR A307 UNO. 31 REMOVE AND REPLACE UPPER AND LOWER BASE CABINETS (COMP051TE WOOD SHALL BE ESDS COMPLIANT, NO ADDED FOR(SSUE 7/18/19 <br /> /� UREA FORMALDEHYDE). MATCH PROPERTY STANDARD. <br /> �/ <br /> , _ _ : _ _ _ _ _ DECK 32 REMOVE AND REPLACE PLASTIC LAMINATE COUNTERTOP (PRODUCT SHALL BE ESDS COMPLIANT).MATCH PROPERTY <br /> (E}HEADER STANDARD. <br /> ��� - - 33 <br /> (� 47 17 29 23 STORAGE O2 REMOVE AND REPLACE CABINETRY, FULL HEIGHT(COMPOSITE WOOD SNALI BE ESDS COMPLIANT, NO ADDED UREA ' • <br /> III FORMALDEHYDE}. <br /> �f - - - - 34 . <br /> k (E}HEADER 13 16 REMOVE AND REPLACE SMOKE DETECTOR. <br /> � �� � � , � 35 <br /> � REMOVE AND REPLACE CARBON MONOXIDE DETECTOR. <br /> � Ii � BEDROOM 1 I I I < 36 REMOVE AND REPLACE ELECTRIC WASHING MACHINE AND DRYER COMBINATION UNIT. + <br /> TOP F� BREAK , 4'-0"MIN LAP SPLICE , BOT fj' BREAK (I <br /> AT EXT WALLS: NAILS TO MATCH LAP SPLICE, ES <br /> (3)16d W/IN 12"TYP AT DBL STUDS OR POST (AT STUD) W/(14)16d,TYP UNO (ATSTUD) � I` 38 14 O2 O7 8 10 ( I _' ; 37 <br /> OF SPLICE(16d @ 12"oc MIN) �' ; ;: 3$ REMOVE AND REPLACE SHELVING AND CLOSET ROD, 24"WIDTH. <br /> (3}16d AT 2x6&2x8 STUDS�--, � �-A35 ONE SIDE T&B AT EXT OPENINGS<_4'-0", 34 I I O <br /> � � � � � � A35 ES T&B AT OPENINGS>4'-0" I II 3g � REMOVE AND REPLACE SHELVING AND CLOSET ROD.MATCH PROPERTY STANDARD. <br /> (2)2x CONT TOP f�,UNO � � I ( �o ; 39 . <br /> � (4)16d,TYP , REMOVE AND REPLACE ELECTRIC WATER HEATER, THERMAL EXPANSION TANK(SEPARATE PERMIT). <br /> 2x STUDS @ 16"oc, UNO L J � � � - � .��r ��H• 40 � 40 <br /> SEE PLAN FOR SIZE � � �,�-- A35 T&B,TYP AT EXT OPENING � _ _ _ _ _ _ I I LIVING I O REMOVE AND REPLACE ELECTRICA�PANEL, 100 AMP (SEPARATE PERMIT). <br /> � 2x BLKG AT SHTG JT, UNO I I I _ _ _ _ _ ROOM ; 41 � <br /> � HDR PER � � HDR PER � (1)2x TRIMMER,TYP � �� 46 I OO OO O 2� � REMOVE AND REPLACE HET TOILET&TQILET SEAT. MATCN PROPERTY STANDARD. <br /> (2)2N FULL HT STUDS `� SCHED UNO � � SCHED UNO (2)2x TRIMMER AT OPENING>8'-0"UNO ON PLANS �I PROJECT NAME: <br /> AT OPNG>4'-0" i ON PLAN I � ON PLAN � NOTCHING OF STUDS NOT PERMITTED. �� 3 � I �2 REMOVE AND REPLACE BATHROOM ACCESSORlES-TOILET PAPER HOLDER, TOWEL BAR&CURTAIN RQD. MATCH <br /> AT EXT: I I ( I (I <br /> PROPERTYSTANDARD. <br /> \ � TYP DOOR I I TYP � (E) 1-HR RATE � • <br /> (2)2x FULL HT STUDS I � WINDOW � I ,� � II ( � PARTY WALL , 43 REMOVE AND REPLACE FIBERGLASS COMBINATION TUB ft SHOWER UNIT, CONTROL VALVE,AND WATERSENSE AVAI RE <br /> AT OPNG<6'-0" ' <br /> 4x FULL HT POST AT I (2)16d I I �gL R NO SPLICES ALLOWED jW II <br /> ' SHOWERHEAD. MATCH PROPERTY STANDARD. <br /> OPNG<8'-0" I AT EA R� 4 Q = BEDROOM 2 I O APARTMENTS <br /> � I � REMOVE AND REPLACE MEOICINE CABINET,VANITY, PLASTIC LAMINATE COUNTERTOP&BACKSPLASH, SINK& <br /> , 6x FULL HT POST AT PTDF SILL f� � � - �_._----- A35 T&B TYP AT EXT OPENING>_4'-0" f ,,; / � <br /> I I I � � O WATERSENSE FAUCET. MATCH PROPERTY STANDARDS. <br /> OPNG< 10'-0" � � O <br /> AT OPNG> 10'-0"USE � � � HEA�ER SCHEDULE , 4 45 <br /> AT NEW STUD � I I c p (�D /� <br /> POST PER PLAN TREAT END W/ I I I I I W/D CPT CPT � . REMOVE AND REPLACE VENTILATION FAN(SEPARATE PERMIT). f (RE RESTIJ fWTI ON <br /> PRE SER V AT N E I I � MAX NOMINAL HEADER - <br /> 46 <br /> AT CURB J _ IL SPAN BRG NON-BRG � � � 36 �� 10 } PAINT DOOR SLAB AND TRIM-2 COATS. U N I�S B'O7 � B'� O <br /> � (E)CURB WHERE , <br /> OCCURS 6'-0" 4x8 OR 8x8 4x$ O �� <br /> 34 9 1� g � 47 pAiNT WINDOW TR1M, SILL&JAMB. <br /> � �� 37 RSL RSL � : �_�� <br /> I I I 8'-0" 4x8 OR 8x8 4x8 � ' �_ O �'_ � 35 <br /> END OF SILL OR � � I AT 3x SILL 10'-0" 4x10 OR 8x10 4x8 � /� <br /> NOTCH OR HOLE WIDER i i i (4)10d TN AT 2x6 � _ _ _ _ _ � I ' G E N E f�HL N OTES <br /> T H A N 1/3 R W I D T H (6)1 0 d T N A 7 2 x 8 12'-0" 4x12 OR 8x12 4x8 � <br /> � 5/a"�GALVANIZED I I 38 � O7 O 8 10 34 35 DINING • <br /> 1.HEADERS TO MATCH WIDTH OF WALL STUDS. <br /> * �/�DHESIVE ANCHORi*�� *= 12"MAXIMUM 2.FOR LARGER OPENINGS,SEE PLANS. I 9 O8 , A. REMOVE AND REPLACE LIGHTING SWITCHES, GFI OUTLETS AND COVERS. TYPICAL THROUGHOUT ROOM, NOT PROJECT LOCATION: . <br /> @ 4'-0"oc, TYP UNO 4 1/2"MINIMUM 3.AT2x8WALLS,USE6xHEADER+2x+SHIMOR6%a"GLB+SHIM. $ 14 '�-. �__ _ O O I SHOWN. (SEPARATE PERMIT ITEM) <br /> O 14 -- -- I � : <br /> 3 B. REMOVE AND REPLACE DUCTWORK, HOT OR COLD AIR, 4"ROUND. PROVIDE VENT TERMINATION CAP AT EXTERIOR. <br /> � � I 33 11 I ;. <br /> 46 - O (SEPARATE PERMIT tTEM) 824 W CAS I NO ROAD <br /> � <br /> ' � �__-- � C. REWIRE (AVERAGE RESIDENCE)COPPER WIRING WITH CONDUIT. TYPICAL THROUGHOUT UNIT, NOT s►-�oWN. EVERET�'f WA 95204 <br /> AT THIS LOCATION REPLACE(E 47 I f � r 12 � (SEPARATE PERMIT ITEM} � <br /> 4 X 8 W I N D O W H E A D E R A N D 2 X 4 I 9 4 5 ' � I ' � <br /> TYPICAL STUDWALL �ND OPENINC FRAMING TRIMMERSTUDSC� 16��0.�. W �� � ! � � � � 3, 29 � � I ! , . <br /> O o BEDROOM 3 , gqTM , 25 , � � D. REMOVE AND REPLACE RESILIENT CHANNEL, 16"O.C. AS NEEDED AT 1NR RATED FLOOR/CEILING �t PARTY WALL <br /> � (LIKE-FOR-LIKE REPLAC MENT); a I 21 I 42 46 47 3Z ( ' O L.00ATfONS ONLY. <br /> SCALE: N.T.S. MAX SPAN 4'-0" = O �O�O� � I 26 - - r;- <br /> � l 23 � 41 � ; +0 27 KITCHEN � ; ' E. REMOVE AND REPLACE P-TftAP ASSEMBLY, PLUMBING FIXTURE SUPPLY LINE. (SEPARATE PERMIT AT ALL FIXTURES) <br /> � � � � � � �� , �$ �� SHEET TITLE: � <br /> I ► ; � oo � <br /> 3b I <br /> NOTE: ALL WORK SHOWN APPROXIMATE. CONFIRM SCOPE AND REPLACEMENT <br /> � - 47 17 21 23 - � � -43- � � I 28 ' QUANTiTIES WITH INSURANCE CLAIM. EN LHRG ED U N( 1 <br /> (R)HEADER 17 p�,qN� <br /> AT THIS LOCATION, REPLACE(E)� <br /> 4X8 WINDOW HEADER AND 2X4 O <br /> TRIMMER STUDS C 16"O.C. STRUCTURAL NOTE: RESTORE DAMAGED ELEMENTS TO EXISTING CONDfT10NS. <br /> (IIKE-FOR-LIKE REPLACEMENT); <br /> MAX SPAN 4'-0" • NO PERIMETER OR BEARING WAI.I SILL PLATE REPLACEMENT <br /> • NOSHEARWALLMODIFICATIONSORREPAIRS ���� ��- ����� ��� <br /> , N NEW _ ' • <br /> • NO BEARWG STUD REPLACEMENT(EXCEPT TRIMMERS AS SHOWN ON PLAN) �����������, �.��� ��,,':��� !. S <br /> UNIT' 8- 10 - 3 �ED/ 1 BATH (L�WER UNIT} <br /> SCALE: 1/4"=1'•0" � <br /> Copyri�ht 2019 by Charles Pick, Architect and Basis Architecture &t Consulting Inc. <br />