<br /> (N)%4 CEMENTITIOUS ,
<br /> NOTE: WHERE (E) PARTITIONS ARE REMOVED,
<br /> MAINTAIN 1-HR FIRE f2ATING. PATCH W�/" INTERIOR EXTERIOR �RIM Architecture .
<br /> TYPE"X"GYP. BOARD, FIRE TAPE & SEAL, INTERIOR EXTERIOR at VQIISUI�II7�
<br /> � - FINISH TO MATCH ADJACENT SURFACES — WALL CONSTRUCTfON MAY
<br /> 1��� 1 �� � (N) FIBER-CEMENT LAP SIDING, BE SHOWN APPROXIMATE. � '
<br /> � -�4 I I �. 6" EXPOSURE OVER(N) BUILDING .
<br /> �: SEALANT, BOTN SIDES OF WALL, LEAVE (N} BLDG PAPER OVER SHEET W�p INSULATE ALL CAVITIES. �
<br /> 1/8"TO 1/4"GAP FOR SEALANT I MEMBRANE FLASHING AND SELF WALL CONSTRUCTION MAY I
<br /> ADHERING FLASHING AND WQW FIN BE SHOWN APPROXIMATE. � . �. 2130 FOURTH ST
<br /> -- � _ � � 1 ���OVERLAP SAN RAFAEL, CA 94901
<br /> ,
<br /> ` � a . MIN 1 �'OVERLAP I� . I (N) SELF ADHERING FLASHING 9" �� ' - ' � - ' � \�
<br /> � PHONE 4� 5 �57-6035
<br /> � � L{P, 0/(N)WDW NAIL FW � \�� � � �
<br /> 2x BLKG C�84"AFF, TYP. ( � (E)T1-11 OR SHEATHING LEAVE%2'GAP AT BOTH SIDES ' �
<br /> \ � (E) OR(N) 2X4 TRIMMER ° � .
<br /> � STUDS; REFER TO PLANS ' � (N) GSM FLASHING W/ HEMMED (N) 1-1/2" BY 1-1/2" NOMINAL -� � P•O. BOX 150539
<br /> '� (N) LAP SIDING FOR REPLACEMENT � a fDGE &CLOSED ENDS (SHOWN FISER-CEMENT TRIM, LEAVE%32' GAP & g � SAN RAFAEL, CA 94915 ,
<br /> NEW 5/8"GYP BRD TAPED AND SANDED INSTALL SHEET MEMBRANE FLASHING LOCATIONS AND SCOPE I DASHED), SLOPE TO DRAIN. SEAL FULLY
<br /> READY FOR PAINT. a, ' � UP 9"WBLDG PAPER OVER � ( : STRAIGHT F ASH ONTO WRB � � ' .
<br /> \ � STARTER STRIP �) ` _.----- LEAVE�"GAP, DO NOT SEAL INSTALL (N) SELF-ADHERING f �
<br /> � N W WORK TO ALIGN WITH EXISTING c ` � a FLASHWG 6" LAP EACH WAY a I
<br /> WHERE INFILLLING OPENINGS IN
<br /> I� .-�-- LEAVE 4'GAP, DO NOT SEAL (E) OR (N)4X8 HEADER, � ' (N)4' FIBER-CEMENT TRIM �
<br /> (E) WALL CONSTRUCTION TO REMAIN (E) HEADER =- � = REFER TO PLANS FOR �� CHARLES PICK, ARCHITECT
<br /> c ( . GALV. MTL FLASHING W/ DRIP REPLACEMENT LOCATIONS N FIBER-CEMENT LAP SIDING, °'�
<br /> UNDER SHEET MEMBRANE FLASHING AND SCOPE � � ,
<br /> r 2x WOOD STUDS C� 16"O.C. I & BLDG. PAPER 2"MIN LEAVE�"GAP, DO NOT SEAL 6" EXPOSURE 0/(N) BLDG WRAP `, I
<br /> TRIM = _- � � �
<br /> (N)a' FIBER-CEMENT TRIM, � I ' '
<br /> AFFIX WITH FINISH NAILS 9252
<br /> WINDOW WRAP PER TYREK (E)T1-11 OR (N)PLYWOOD SHEATHIN REGISTERED
<br /> SEAL FULLY DETAIL SHEETS , � ARC ITECT
<br /> INTERIOR
<br /> P.T. SfLL PLATE
<br /> EXTERIOR c��
<br /> i (N) CONSTRUCTIQN TYPE WDW ' .
<br /> CHARLES PICK
<br /> SEALANT, BOTH SIDES OF WALL, LEAVE DOOR& FRAME W/NAIL FIN STATE OF WASHINGTON .
<br /> �}���_�4�� ;. 1/$"TO 1/4"GAP FOR SEALANT
<br /> r -�_' \" EXPIRATION DATE:6/18/20Z1
<br /> � (E) PLYWOOD FLOORING
<br /> NEW INT. 2X4 PARTITION NON-RATED EXTERIQR DOQR �IEAD C� SIDfNG WDW HEAD AT FI �ER C�NIENT SIDIN� FIBER CEMENT DETAIL AT INSIDE CORNER � .
<br /> A 7
<br /> .. _ � . , _ , � ,. _ . , � _ . �
<br /> SCALE: 1 1 /2 - 1 -0' SCALE: 3' - 1 -0" SCALE: 3 - � -0' (SLfDING GLASS DOOR SIMILAR) SCALE: 3' - 1 -0'
<br /> LEGEND
<br /> WALL CONSTRUCTION MAY BE (E) WALL TO REMAIN � �
<br /> SHOWN APPROXIMATE.INSULATE .
<br /> ALL CAVITIES. - - - (E) WALL TO BE REMOVED
<br /> INTERIOR EXTERIOR — — —
<br /> NOTE: MAINTAIN 1-HR FIRE RATING AT
<br /> , FLR/CLG ASSEMBLY. PATCH W�/"TYPE"X" 6 �ii�� (N) INTERIOR PARTITION
<br /> � FIRE RATED GYP. BOARD, FIRE TAPE & SEAL, (N)CONSTRUCTION TYPE
<br /> FINISH TO MATCH ADJACENT SURFACES
<br /> ���'�4�� WBELS OWN AP ROXIMATE \ ' , ,� � o a. . .a � . a
<br /> WDW W/FlN (N)%CEMENTITIOUS � , j I � 1 HOUR RATED WALL
<br /> SEALANT, BOTH SIDE$ OF WALL, LEAVE , TRIM, TYP \��a�__�-�-`�-s=��__— _____— ,
<br /> } 118"TO 1/4"GAP FOR SEALANT INTERIOR EXTERIOR ���i�
<br /> � 3„ ADDITIONAL 24"OF WRB 0lSAF \' ��
<br /> m LEAVEg" -32 GAP AND SEAL � ��
<br /> �
<br /> W 5/8"T Y P E 'X' F I R E R A T E D G Y P B R D �
<br /> � � (N) SELF ADHERING FLASHING LEAVE 3/2'GAP £t SEAL FULLY ��I '
<br /> Q (N)RESILIENT FLOORING ENTRY DOOR. SEE 1/A5.2 FOR (E) 2X4 D�UBLE _ o ' (S.A.F.) 0/ FRAMING, 9"MW a��I .
<br /> W AT ENTRY W/ALUM THRESHOLD REQUfREMENTS AT SILL PLATES �I'�1.° I�
<br /> � 2x BLKG C 84"AFF, TYP. � 5 � � �� —
<br /> � SADDLE 0/TO SECURE ACCESSIBLE LOCATIONS � � `:: (N)4' FIBER-CEMENT TRIM, INSTALL (N) SELF-ADHER(NG �
<br /> f— � ' NOTE: FLOORING _.� �- a_ AFFIX WITH FINISN NA(LS FLASHING 6" LAP EACH WAY '��
<br /> v� �., 1"MIN. OVERHANG SET � �_'• :: ,
<br /> • W NEW WORK TO ALIGN WITH EXISTING �' IN SIKAFLEX 1Q (E) WALL � r INSTALL (N) S.A.F. UNDER WDW FIN °� � ��
<br /> �' WHERE INFILLLING OPENINGS IN � /� CONSTRUCTION o� �I I
<br /> 0 {E)WALL CONSTRUCTION TO REMAIN z �° TO REMAIN � �' LEAVE$" -32'GAP AND SEAL (N) FIBER-CEMENT LAP SIDING,
<br /> � � � 6"EXPOSURE OJ(N) BLDG WRAP � � DRAWING REVISION LOG
<br /> � � � ���I. INSTALL SHEET MEMBRANE � •
<br /> 0 2"x 4"WOOD STUDS A7 16" OC a ' � - ; � ��� • 4� I FOR ISSUE 7/s�%19
<br /> INSULATION IN ALL STUD CAVIT(ES ° ° ° � � � � � � � FLASHING DN 12", TUCK BLDG � � .�
<br /> W � � � , ° � � , � ' PAPER UNDER (E)T1-11 OR (N)PLYWOOD I
<br /> ° � � � ° ' � ° - �`' � i i � SHEATHING
<br /> Z '' `` ° ,I� BLDG PAPER TUCK UNDER i �
<br /> tn � .
<br /> � d U
<br /> Q ° (E) OR(N) CONC a'a � > (N)LEVEL � , SHEET MEMBRANE FLASHING � INTERIOR
<br /> a , , ' EXTERIOR
<br /> � � a d , CONC LDG � .,a � . & OVER SELF ADHERING ,_ �
<br /> �
<br /> 4 4 Q , 4 . . d (1 : - ' ,
<br /> � a � a a Q � � FLASHiNG '
<br /> a
<br /> LL _ 3 � ^ � v � r`` I; , � .
<br /> � P.T. SILL PLATE 6N EXPOSURE OVER N) B`UILDING ;� �
<br /> . �i (N)EXPANSION JNT � WRAP , � \�
<br /> SEALANT, BOTH SIDES OF WALL, LEAVE (N) OR (E) PLYWOOD SHEATHING (
<br /> ����_�4�� 1/8"TO 1/4"GAP FOR SEALAN7 , (
<br /> (E) PLYWOOD FLOORING
<br /> E PARTY WALL RESTORATION � -HR R,ATED EXTERIOR DOOR THRESHO�D WDW S� LL AT FI �ER CENIENT SI �ING FI �ER �EMENT DETAIL A1� OUT5IDE CURNER � .
<br /> ) 2 . .
<br /> B SCALE: 1 1/2" = 1'-0" � 5CALE: 3" = 1`-0" � SCALE: 3" = 1'-0" SCALE: 3" = 1'-0"
<br /> PROJECT NAME:
<br /> (E)INTERIOR EXTERIOR q tp
<br /> r � (N) BLDG WRAP AVHI C�E
<br /> j (N) BLDG WRAP 0/ (N) SHEET MEMBRANE APAR�`MEN�S � .
<br /> FLASHING & SELF ADHERING FLASHING
<br /> SEE EXTERIOR SIDING DETAILS ��' '
<br /> � THIS SHEET FOR INSTALLATION � (N)SAF AT HEAD
<br /> �� ' FIRE RES?'�RA1"ION
<br /> ' ; �( �'GAP, DO NOT CAULK
<br /> i � i�� � UNITS 8-09 �t �-10 � � �
<br /> I I (N) GALV. Z-FLASHING W/CLOSED ENDS
<br /> �AR�W/ � i � (N) "STURDIMOUNT"OR FIELD
<br /> � � '� APPLIED CEMENT F(BER BLOCK
<br /> SIDE FLANGE HEMMED EDGE �
<br /> � ° (N)PT STARTER STRIP � T �
<br /> ` �:l � � PROJECT LOCATION:
<br /> �� LAP BLDG PAPER 0! (N) GSM �
<br /> PAN PORTION �� � ' FLASHING W/HEMMED EDGE, SET '�
<br /> FIXTURE, PLUMBING OR
<br /> -°F SIDE DAM � I' I - ONOT NUO SHBEADSEALANT, 3 j�'� Q�W pUT� g X I O N W I T H $ZL�, CAJ t ROAD �
<br /> i� , i W NO
<br /> FRONT FLANGE � I� 2" CLR I ( � EVERETT, WA 95204 .
<br /> II / � J '
<br /> � a_ a
<br /> ° � � ���' '�i ��
<br /> SIDE FLANGE II ° a � NOTE: � _ _.-- .
<br /> ( ° ti (N�) CON� . a REFER TO ;� �
<br /> (�, (N)CONC DETAIL 1/8"GAP WITH (N) SEALANT
<br /> � � � � SIDES AND BOTTOM
<br /> 1/2"MIN i
<br /> , (E)CONC FTG II ' � a � -a a !� SHEET TITLE:
<br /> NOTE: �� r. j
<br /> OPTIONAL 2 PIECE SILL PAN WITH 2 M�N �� II v
<br /> 3"MINIMUM OVERLAP, SEAL FULLY GSM MTL�! SELF ;I I °, DETA1 LS
<br /> ADHERING B17HUTHENE . .
<br /> INTERIOR EXTERIOR WALL CONSTRUCTION MAY
<br /> 1" LOWER THAN � BE SHOWN APPROXIMATE.
<br /> BOTTOM OF SLAB � - INSULATE ALL CAVITIES.
<br /> �i i�'°� �� ���''������' .
<br /> ���1i�'���� ��".�� �'������` o .
<br /> N S� D GSM SILL PAN N FLASHIN� /��NC AT FIBER C�MENT FIXTURE U TI AT FI �ER CEME T'
<br /> 3 MO N NG N
<br /> 9 SCALE: 3" = 1'-0" � SCALE: 3" = 1 -0 �� _ � ��
<br /> SCALE: 3 - 1 -0
<br /> Copyright 2019 by Charles Pick, Architect and Basis Architecture �t Consultin� Inc. . .
<br />
|