|
,
<br /> S + L Arci�itects, LLC
<br /> 273'I 183�d Ava SE Snotiomisli 98290 �
<br /> 360.563.'1032 c206.990.8348
<br /> CLASS C TESTED (ASTM E 108/ UL
<br /> 790) 3/4" FIRE-REATARDENT
<br /> TREATED PLYWOOD - SEE ROOF •
<br /> � (/ PLAN
<br /> ��I i� / /�
<br /> �� ��� R-19 EQUIVALENT AT ATTIC CAVITY
<br /> �', �J (R-19 + 2 LAYERS R-15 RIGID =
<br /> ROOF CONSTRUCTION: ' � R-49) --��-. ,
<br /> EXISTING 2 x 4 RAF�ERS AT 24" o.c. `',�`U� ^ ��
<br /> WITH LVL PER STRUCTURAL AND ��U �U� t� �
<br /> � _�
<br /> `�..���;� �
<br /> PROPRIETARY BLOWN-IN INSULATION. ,�.,_, �
<br /> ASPHALT ROOFING OVER WEATHER FIREBLOCK
<br /> BARRIER OVER 3/4" PLYWOOD
<br /> SHEATHING OVER 2 x 4 SLEEPERS t�;�',�� PARTY WALL CONSTRUCTION PER WALL TYPES.
<br /> �_., . :
<br /> (FLAT) OVER (2) LAYERS R-15 RfGID 5/8" GWS / ; ,.�,.. ,��,�. , :-' , :. �: - 1 � SHEET A-10.0
<br /> INSUlATION OVER EXISTWG PLYWOOD � ' ��- � /
<br /> SHEATHING AT EXTERIOR SIDE ��'7�1�1_�,J (�',�I/! UPPER FLOOR LEVEL -�� , •
<br /> ---~ AII material appearing hereio constiddrtes the unpublished and
<br /> odginal work of the Architect and may not be duplicated,
<br /> FLOOR CONSTRUCTION: NEW ' '� PROVIDE FIRE BLOCKING PER IRC R302.11 � used,adisdosedwiurouttr�ewrittenco�eMotme/vcn�ect
<br /> EXISTING 2 x 10 FLOOR JOISTS AT _ �"- BEDROOM � '�. NOT MORE TNAN 10'-0" o.c. HORIZONTA�
<br /> 16" o.c. FINISH FLOORING OVER ; `�,`'�'-- C-201 � AND VERTICAL
<br /> l . Architact Stamp:
<br /> 1/2" PLYWOOD SUBFLOOR ABOVE ��'
<br /> JOISTS; 5�8" GWB ATfACHED TO r ��� '� � _
<br /> UNDERSIDE OF JOISTS � - - - - - - ��v` PLYWOOD
<br /> � 9254 REGISTERED
<br /> � \-��; ,i ;.,, FIRE BLOCKING ARCHITECT
<br /> � .���� � � _ -
<br /> + - 12�-8�� � ��� � - _.
<br /> � �
<br /> TOP OF EXISTING SUB-FLOOR I + !,_- FIRE SEALANT
<br /> GWB CONTINUOUS C� PERPINDICULAR HINTARO G
<br /> UPPER FLOOR LEVEL � � WALLS, TYP. \—� STATE OF WASHINGTON
<br /> � � � �,---� PLYWOOD FLOOR SHEATHING
<br /> -..
<br /> �-- - - - - -�
<br /> 14 NEW BEAM
<br /> Projact Titla:
<br /> A 10.0
<br /> EXISTING FLOOR ,101ST
<br /> BLOCKING
<br /> � NEW - NEW
<br /> "' FAMILY � KITCNEN o0
<br /> � C-102 � � C-101 � : (2) LAYERS 5/8" TYPE 'X' GWB
<br /> FLOOR CONSTRUCTION: � ;� ' ` " ' COLBY AVENUE
<br /> EXISTING 2 x �o F�ooR �o�sTs AT _ _ RESIDENCE
<br /> 16" o.c. WITH NEW 2 x 10 JOISTS - . -_ —(3) 2 x 10 FIRE BLOCKING
<br /> �_- _-= REMODEL
<br /> _�-- �---
<br /> PER STRUCTURAL (SOUTH SIDE ONLY). �r j,, _
<br /> i � :
<br /> FINISH FLOORING OVER 1/2" PLYWOOD ;Y, � ---= FIRE BLOCKING
<br /> SUBFLOOR ABOVE JOISTS; 5/8" GWB � 5/8" GWB AT � �
<br /> Ai�ACHED TO UNDERSIDE OF JOISTS � � o UNDERSIDE OF STAIR
<br /> + - 3'-5 1 4" �
<br /> TOP OF EXISTING SUB-FLOOR � � �'-' ��'
<br /> � �' , � �
<br /> GROUND LEVEL
<br /> ---,
<br /> PROVIDE FIRE BLOCKING PER iRC R302.11 �
<br /> NOT MORE THAN 10'-0" o.c. HORIZONTAL
<br /> ���. EXISTING BEAM ..'.
<br /> � _ _ _ _ _ GROUND FLOOR LEVE� - aN� vERTica�
<br /> � -� -�- 3714 Colby Avenue
<br /> +o'-o" r 1 �'� �-i��i—�� � �=--, �=-�J P��rw000 Everett WA 98201 •
<br /> APPROXIMATE GROUND LE L �= NEW � "-� "� � �-= ' '
<br /> ��������� , � NEW 1� ��' �� 1-E�1���1� . � ��
<br /> � i!�I-I i I=�i I BEDROOM � BATHROOM I=I I I=I(I=I FIRE BLOCKING
<br /> �-��(-������ �.� C-0 0 4 � C-0 0 2 ���� �_� � �_� ( (= .
<br /> � � �
<br /> � �11=1 I 1=1��.- <� � � EI I 1=111=1 I 1= ~ - �
<br /> i LINE OF WINDOW WELL `��I=I!I I� '' I �
<br /> � B�rOND ��•� � .� �I I—I I I—I i I— -_�
<br /> ��__ � � '�' _ _, �I I I=I I I=1 I i , = FIRE SEAu�NT
<br /> , � I I I I I ��, =� E � �- �.. � �'� ; I�i T I I I=1 I I=I I I=I I I=� � � GWB CONTINUOUS � PERPINDICUI.AR
<br /> , -,
<br /> I— I i��—l�--=��I=1 i�- :� '� = wa��s, rrP. _
<br /> ' �I�I I i—I I I=I I I�I I I=I I �� ) •j -I I I�I I I�I I Ii I I I,�}I I I= PLYWOOD FLOOR SHEATHING
<br /> I I�'I-�-�1=1-�-��l-�� : �� ��� I I-1�i-1!I�, I I`� , ��
<br /> =1 I 1=1 I i-1 I 1-1{i==i� �;. �5 ' '--' � '��
<br /> -�j- - - - � '_ � A10.0 �. ���(_���-� I 1��_
<br /> �--I (I-I�I-I� �-I�I- , EXISTING CONCRETE FLOOR �'' j,�-i I I=i i��
<br /> �• �)��=�!� EXISTING FLOOR JOIST
<br /> —' � 1-i i 1=1 I I-=�� :. s�`B �� I I-1 I 1-
<br /> Issua �ata: January 20'18
<br /> =1 'i=1 I I—I (i- �' .
<br /> � � -1 l iil �
<br /> + - -6'-5" �� I �_ �_ ' `� . . - - BLOCKING '
<br /> • • •. .. �,.;. • . ::. • . .•,. "* • � . . • ;. . ..� . .. . . .r . '. . •. '�� i-
<br /> — �� _ .,•�,� � ,._ , i .i I E.--- !•' -1 1'--- : I"_�-� : i � .___:I • '""! - i 1- � I r__.i i � i i- �� 1_.-_. I —I "i i.• 'i�� . �_ �— —
<br /> TOP OF EXISTING CONCRETE SLAB - - ��-�� - -- - � i �- � �__ I �=._ �-� --. �-- : __�_. - - --- - - ,--' , ---1 � ,---� , ---, � '=-, . , __. , �-, _.. : r -: + . �__, I .• � ,-u, ; l •�� =� - i PERMIT SET
<br /> .�._:I I .' '---� -`- — — I �__.:i I � I� ; '..—.; � �..__ 1 �_`� ' f� I��I i !_:� �. �-�i 1 �—I � I�_... i �-4 � I---i ! i—) I I..�_i I s--I � . ...: � :- - , ; ,_,�i t .�_i :.i---�r--I��--��� .� ' —1�1—I I—i '_�'-
<br /> I� ��- . .-�I i^�� -� i-��-E�-�� �=��(- {- ��--, � � � , � � �_� � � , � ,� I v � I ���= 2 IAYERS 5 8 TYPE 'X' GWB
<br /> BASEMENT LEVEL - _ �__ �� _!� �_�_ - - =I I I= I I=I I I=I I I=I I I=I I I=I I I=I I I-I i I=I I I=i (I=I I I=I I I=I 1 I~I I (=I I I=I I I=I I I=1 I !=I�IJI (1=1!(=1 I i=I i (=1 ��_�� i=i��=i� �=� 1 `•: ���. O /
<br /> �I , iI ; �� . . ;,� � � I i_I I I—I I I—I I I—I f I I _ �_I I I I I 1=1 I 1=1 I 1=1 I 1�=1 I 1=1 I 1=1 I I-1 I l=1 I I�I! I�I I 1=I i 1=1 I 1=1 I 1=1 { I :: --1_I I i=1
<br /> �- �i=;,.� .• I1=I��—���=���I������;,�11—� "—' i1=111=11�,�,���,;,{��=111—� ��-�� � �I1=111�II�-11 — I� _
<br /> Projact Numbar: xxxx
<br /> ' I I i' i- ; illill��'llllll,—
<br /> � �- � ��—�� � —���—� � �-=1 I I-1 I I—I I 1=1 I 1=i I 1=I I � i i_�i�i I I f-
<br /> '_�I I-1!1=1 I I-1 I! '� =I' -- I-1 i
<br /> ;=1 I I-11 I. ��;� I I I-1 I 1-1� -1 I I-1 I 1—i I I—_����__—i I I-1 I I- -_ � _' (3) z x 10 FIRE BLOCKING
<br /> �I i I-1 I 1-I ! = I-1 I � �I i���I I 1-1 I I-1 I I— —I I i-1 I I-1 -_
<br /> -1 i I-1 i i-1 !I-1 I I- -I I I-1 I I�I I I�i I I-=1 I I—I I I- �
<br /> -� ( I-I I I ���- -I I I=I I I=I I I-I I(-I {�� --� J�� FIRE BLOCKING Ravlslons:
<br /> 'i�- � �� � �� � ���� 1�-
<br /> No
<br /> �i.: 1 7.25.18 OWNER CHANGE
<br /> q Wal1 Section A-A �
<br /> Scale: 3/8"=1'-0" PROVIDE FIRE BLOCKING PER 1RC R302.11 @
<br /> NOT MORE THAN 10'-0" o.c. HORIZONTAL
<br /> BASEMENT LEVE� AND VERTICAL
<br /> �-_
<br /> GWB CONTINUOUS 4 PERPINDICULAR
<br /> WALLS, TYP. EXISTING CONCRETE FLOOR SLAB (SAWCUT AS
<br /> - REQUIRED TO INSTALL FOOTING AND
<br /> TOWNHOUSE NOTES: INSU�ATION)
<br /> 1. TOWNHOUSE SEPARATION WALLS SHALL BE 2-HOUR FIRE RATED PER lRC R302.2
<br /> SFiaet Contants: ,
<br /> WITH CITY OF EVERETf AMENDMENTS.
<br /> 4 R-10 RIGID INSULATION,
<br /> � 2. TOWNHOUSE PARAPETS SHALL MEET THE REQUIREMENTS PER IRC R302.2.2, NOTE 2, a d o BOTH S�DES oF FOOTING
<br /> EXCEPTION. ° a
<br /> __._�
<br /> a ,
<br /> i ; � � Ii �=
<br /> i � � �� i -, � � � � --- � � ��� _i i__�
<br /> 3. NO THRU PENETRATIONS IN PARTY WALL r � - � � �� � ! !� � '�
<br /> � � 1i= 11 �—� � � � s � � � i— i � — S �CTION � �
<br /> �—� � ( � d � � �—
<br /> I � � (;_� �
<br /> ,���� If� � � � a � � � �_- �
<br /> ���—I � �� � a� � �=; '
<br /> I 1=1 I I � � ° � a � �� I I 1-�- � �
<br /> ,l I I;I — � �_�,,_;, ;_ ,—�„�;� � ____.
<br /> --' '�---�'I i=1 I —I f �—i I � l � I—izl �I I. ; � ` �
<br /> F � � ,=-- S�aat:
<br /> _ �—_ I i I�I I i_�: , ,
<br /> . _ — , _ _ ,�_
<br /> g Partial Wall Section B-B (2-Hr Party Wali)
<br /> . . � � i�
<br /> S�a�e: ,_,,2-=, _�
<br /> A
<br /> � 2018,S+L Architects,LLC
<br /> . , ��
<br />
|