Laserfiche WebLink
, <br /> S + L Arci�itects, LLC <br /> 273'I 183�d Ava SE Snotiomisli 98290 � <br /> 360.563.'1032 c206.990.8348 <br /> CLASS C TESTED (ASTM E 108/ UL <br /> 790) 3/4" FIRE-REATARDENT <br /> TREATED PLYWOOD - SEE ROOF • <br /> � (/ PLAN <br /> ��I i� / /� <br /> �� ��� R-19 EQUIVALENT AT ATTIC CAVITY <br /> �', �J (R-19 + 2 LAYERS R-15 RIGID = <br /> ROOF CONSTRUCTION: ' � R-49) --��-. , <br /> EXISTING 2 x 4 RAF�ERS AT 24" o.c. `',�`U� ^ �� <br /> WITH LVL PER STRUCTURAL AND ��U �U� t� � <br /> � _� <br /> `�..���;� � <br /> PROPRIETARY BLOWN-IN INSULATION. ,�.,_, � <br /> ASPHALT ROOFING OVER WEATHER FIREBLOCK <br /> BARRIER OVER 3/4" PLYWOOD <br /> SHEATHING OVER 2 x 4 SLEEPERS t�;�',�� PARTY WALL CONSTRUCTION PER WALL TYPES. <br /> �_., . : <br /> (FLAT) OVER (2) LAYERS R-15 RfGID 5/8" GWS / ; ,.�,.. ,��,�. , :-' , :. �: - 1 � SHEET A-10.0 <br /> INSUlATION OVER EXISTWG PLYWOOD � ' ��- � / <br /> SHEATHING AT EXTERIOR SIDE ��'7�1�1_�,J (�',�I/! UPPER FLOOR LEVEL -�� , • <br /> ---~ AII material appearing hereio constiddrtes the unpublished and <br /> odginal work of the Architect and may not be duplicated, <br /> FLOOR CONSTRUCTION: NEW ' '� PROVIDE FIRE BLOCKING PER IRC R302.11 � used,adisdosedwiurouttr�ewrittenco�eMotme/vcn�ect <br /> EXISTING 2 x 10 FLOOR JOISTS AT _ �"- BEDROOM � '�. NOT MORE TNAN 10'-0" o.c. HORIZONTA� <br /> 16" o.c. FINISH FLOORING OVER ; `�,`'�'-- C-201 � AND VERTICAL <br /> l . Architact Stamp: <br /> 1/2" PLYWOOD SUBFLOOR ABOVE ��' <br /> JOISTS; 5�8" GWB ATfACHED TO r ��� '� � _ <br /> UNDERSIDE OF JOISTS � - - - - - - ��v` PLYWOOD <br /> � 9254 REGISTERED <br /> � \-��; ,i ;.,, FIRE BLOCKING ARCHITECT <br /> � .���� � � _ - <br /> + - 12�-8�� � ��� � - _. <br /> � � <br /> TOP OF EXISTING SUB-FLOOR I + !,_- FIRE SEALANT <br /> GWB CONTINUOUS C� PERPINDICULAR HINTARO G <br /> UPPER FLOOR LEVEL � � WALLS, TYP. \—� STATE OF WASHINGTON <br /> � � � �,---� PLYWOOD FLOOR SHEATHING <br /> -.. <br /> �-- - - - - -� <br /> 14 NEW BEAM <br /> Projact Titla: <br /> A 10.0 <br /> EXISTING FLOOR ,101ST <br /> BLOCKING <br /> � NEW - NEW <br /> "' FAMILY � KITCNEN o0 <br /> � C-102 � � C-101 � : (2) LAYERS 5/8" TYPE 'X' GWB <br /> FLOOR CONSTRUCTION: � ;� ' ` " ' COLBY AVENUE <br /> EXISTING 2 x �o F�ooR �o�sTs AT _ _ RESIDENCE <br /> 16" o.c. WITH NEW 2 x 10 JOISTS - . -_ —(3) 2 x 10 FIRE BLOCKING <br /> �_- _-= REMODEL <br /> _�-- �--- <br /> PER STRUCTURAL (SOUTH SIDE ONLY). �r j,, _ <br /> i � : <br /> FINISH FLOORING OVER 1/2" PLYWOOD ;Y, � ---= FIRE BLOCKING <br /> SUBFLOOR ABOVE JOISTS; 5/8" GWB � 5/8" GWB AT � � <br /> Ai�ACHED TO UNDERSIDE OF JOISTS � � o UNDERSIDE OF STAIR <br /> + - 3'-5 1 4" � <br /> TOP OF EXISTING SUB-FLOOR � � �'-' ��' <br /> � �' , � � <br /> GROUND LEVEL <br /> ---, <br /> PROVIDE FIRE BLOCKING PER iRC R302.11 � <br /> NOT MORE THAN 10'-0" o.c. HORIZONTAL <br /> ���. EXISTING BEAM ..'. <br /> � _ _ _ _ _ GROUND FLOOR LEVE� - aN� vERTica� <br /> � -� -�- 3714 Colby Avenue <br /> +o'-o" r 1 �'� �-i��i—�� � �=--, �=-�J P��rw000 Everett WA 98201 • <br /> APPROXIMATE GROUND LE L �= NEW � "-� "� � �-= ' ' <br /> ��������� , � NEW 1� ��' �� 1-E�1���1� . � �� <br /> � i!�I-I i I=�i I BEDROOM � BATHROOM I=I I I=I(I=I FIRE BLOCKING <br /> �-��(-������ �.� C-0 0 4 � C-0 0 2 ���� �_� � �_� ( (= . <br /> � � � <br /> � �11=1 I 1=1��.- <� � � EI I 1=111=1 I 1= ~ - � <br /> i LINE OF WINDOW WELL `��I=I!I I� '' I � <br /> � B�rOND ��•� � .� �I I—I I I—I i I— -_� <br /> ��__ � � '�' _ _, �I I I=I I I=1 I i , = FIRE SEAu�NT <br /> , � I I I I I ��, =� E � �- �.. � �'� ; I�i T I I I=1 I I=I I I=I I I=� � � GWB CONTINUOUS � PERPINDICUI.AR <br /> , -, <br /> I— I i��—l�--=��I=1 i�- :� '� = wa��s, rrP. _ <br /> ' �I�I I i—I I I=I I I�I I I=I I �� ) •j -I I I�I I I�I I Ii I I I,�}I I I= PLYWOOD FLOOR SHEATHING <br /> I I�'I-�-�1=1-�-��l-�� : �� ��� I I-1�i-1!I�, I I`� , �� <br /> =1 I 1=1 I i-1 I 1-1{i==i� �;. �5 ' '--' � '�� <br /> -�j- - - - � '_ � A10.0 �. ���(_���-� I 1��_ <br /> �--I (I-I�I-I� �-I�I- , EXISTING CONCRETE FLOOR �'' j,�-i I I=i i�� <br /> �• �)��=�!� EXISTING FLOOR JOIST <br /> —' � 1-i i 1=1 I I-=�� :. s�`B �� I I-1 I 1- <br /> Issua �ata: January 20'18 <br /> =1 'i=1 I I—I (i- �' . <br /> � � -1 l iil � <br /> + - -6'-5" �� I �_ �_ ' `� . . - - BLOCKING ' <br /> • • •. .. �,.;. • . ::. • . .•,. "* • � . . • ;. . ..� . .. . . .r . '. . •. '�� i- <br /> — �� _ .,•�,� � ,._ , i .i I E.--- !•' -1 1'--- : I"_�-� : i � .___:I • '""! - i 1- � I r__.i i � i i- �� 1_.-_. I —I "i i.• 'i�� . �_ �— — <br /> TOP OF EXISTING CONCRETE SLAB - - ��-�� - -- - � i �- � �__ I �=._ �-� --. �-- : __�_. - - --- - - ,--' , ---1 � ,---� , ---, � '=-, . , __. , �-, _.. : r -: + . �__, I .• � ,-u, ; l •�� =� - i PERMIT SET <br /> .�._:I I .' '---� -`- — — I �__.:i I � I� ; '..—.; � �..__ 1 �_`� ' f� I��I i !_:� �. �-�i 1 �—I � I�_... i �-4 � I---i ! i—) I I..�_i I s--I � . ...: � :- - , ; ,_,�i t .�_i :.i---�r--I��--��� .� ' —1�1—I I—i '_�'- <br /> I� ��- . .-�I i^�� -� i-��-E�-�� �=��(- {- ��--, � � � , � � �_� � � , � ,� I v � I ���= 2 IAYERS 5 8 TYPE 'X' GWB <br /> BASEMENT LEVEL - _ �__ �� _!� �_�_ - - =I I I= I I=I I I=I I I=I I I=I I I=I I I=I I I-I i I=I I I=i (I=I I I=I I I=I 1 I~I I (=I I I=I I I=I I I=1 I !=I�IJI (1=1!(=1 I i=I i (=1 ��_�� i=i��=i� �=� 1 `•: ���. O / <br /> �I , iI ; �� . . ;,� � � I i_I I I—I I I—I I I—I f I I _ �_I I I I I 1=1 I 1=1 I 1=1 I 1�=1 I 1=1 I 1=1 I I-1 I l=1 I I�I! I�I I 1=I i 1=1 I 1=1 I 1=1 { I :: --1_I I i=1 <br /> �- �i=;,.� .• I1=I��—���=���I������;,�11—� "—' i1=111=11�,�,���,;,{��=111—� ��-�� � �I1=111�II�-11 — I� _ <br /> Projact Numbar: xxxx <br /> ' I I i' i- ; illill��'llllll,— <br /> � �- � ��—�� � —���—� � �-=1 I I-1 I I—I I 1=1 I 1=i I 1=I I � i i_�i�i I I f- <br /> '_�I I-1!1=1 I I-1 I! '� =I' -- I-1 i <br /> ;=1 I I-11 I. ��;� I I I-1 I 1-1� -1 I I-1 I 1—i I I—_����__—i I I-1 I I- -_ � _' (3) z x 10 FIRE BLOCKING <br /> �I i I-1 I 1-I ! = I-1 I � �I i���I I 1-1 I I-1 I I— —I I i-1 I I-1 -_ <br /> -1 i I-1 i i-1 !I-1 I I- -I I I-1 I I�I I I�i I I-=1 I I—I I I- � <br /> -� ( I-I I I ���- -I I I=I I I=I I I-I I(-I {�� --� J�� FIRE BLOCKING Ravlslons: <br /> 'i�- � �� � �� � ���� 1�- <br /> No <br /> �i.: 1 7.25.18 OWNER CHANGE <br /> q Wal1 Section A-A � <br /> Scale: 3/8"=1'-0" PROVIDE FIRE BLOCKING PER 1RC R302.11 @ <br /> NOT MORE THAN 10'-0" o.c. HORIZONTAL <br /> BASEMENT LEVE� AND VERTICAL <br /> �-_ <br /> GWB CONTINUOUS 4 PERPINDICULAR <br /> WALLS, TYP. EXISTING CONCRETE FLOOR SLAB (SAWCUT AS <br /> - REQUIRED TO INSTALL FOOTING AND <br /> TOWNHOUSE NOTES: INSU�ATION) <br /> 1. TOWNHOUSE SEPARATION WALLS SHALL BE 2-HOUR FIRE RATED PER lRC R302.2 <br /> SFiaet Contants: , <br /> WITH CITY OF EVERETf AMENDMENTS. <br /> 4 R-10 RIGID INSULATION, <br /> � 2. TOWNHOUSE PARAPETS SHALL MEET THE REQUIREMENTS PER IRC R302.2.2, NOTE 2, a d o BOTH S�DES oF FOOTING <br /> EXCEPTION. ° a <br /> __._� <br /> a , <br /> i ; � � Ii �= <br /> i � � �� i -, � � � � --- � � ��� _i i__� <br /> 3. NO THRU PENETRATIONS IN PARTY WALL r � - � � �� � ! !� � '� <br /> � � 1i= 11 �—� � � � s � � � i— i � — S �CTION � � <br /> �—� � ( � d � � �— <br /> I � � (;_� � <br /> ,���� If� � � � a � � � �_- � <br /> ���—I � �� � a� � �=; ' <br /> I 1=1 I I � � ° � a � �� I I 1-�- � � <br /> ,l I I;I — � �_�,,_;, ;_ ,—�„�;� � ____. <br /> --' '�---�'I i=1 I —I f �—i I � l � I—izl �I I. ; � ` � <br /> F � � ,=-- S�aat: <br /> _ �—_ I i I�I I i_�: , , <br /> . _ — , _ _ ,�_ <br /> g Partial Wall Section B-B (2-Hr Party Wali) <br /> . . � � i� <br /> S�a�e: ,_,,2-=, _� <br /> A <br /> � 2018,S+L Architects,LLC <br /> . , �� <br />