My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 SE EVERETT MALL WAY 2019 AEROTEK Plans 2022-12-02
>
Address Records
>
SE EVERETT MALL WAY
>
1010
>
AEROTEK
>
Plans
>
1010 SE EVERETT MALL WAY 2019 AEROTEK Plans 2022-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2022 10:19:49 AM
Creation date
10/29/2020 8:04:23 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1010
Tenant Name
AEROTEK
Permit
B1903-041
Year
2019
Notes
DEMO EXTG WALLS FRAME AND ADD NEW OFFICE SPACES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. I � . . . . .. . . <br /> � I�E�oT��{ ���� ���"'���UL� �� <br /> � ,�'r `�`' <br /> N, � DETAILS ��L✓� � t,����' <br /> � <br /> , � �" � O <br /> � W �- � � � 1402 3rd Ave Suite 730 <br /> N � � � w z � z W Seattle, WA 98101 ' • <br /> , a Z z � � <br /> r z � � � � u- � <br /> Q <br /> O O O O O O � � Q � ARCHITECT/CONSULTANT STAMP <br /> � � � � � CL' � <br /> � REMARKS <br /> M �p �p � 0 � � ti 2 = -¢i <br /> X • <br /> N 01A 3'-0" 7'- 0° (E) (E) (E) - 7 (E) (E) REPAIR EXISTING FULL LITE ENTRY DOOR. a,�a�s REcisr�R�� <br /> N 01 B 3'-0" 7'-0" (E) (E) (E) - 1 (E) (E) ,� aRCHirEc r <br /> u� 01 C 3'- 0" 7'-0" (E) (E) (E) - 3 (E) (E) � <br /> � - <br /> z <br /> 02A 3'- 0" 7'-0° F WD/ ST 1 7/A0.12 2/A0.12 FURNISH AND INSTALL NEW DOOR, STAIN GRAD , sr,orr a�a� coNNo� <br /> w LS FLUSH DOOR WITH FULL LIITE &HARDWARE . <br /> STAiE OF WA=HIN,TON <br /> � 03A 3'-0" 7' - 0" A WD ST - 1 7/A0.12 2/A0.12 REINSTALL SALVAGED SOLID FLUSH DOOR FROM <br /> � U EXISTING SPACE <br /> 0 04A 3'- 0" 7'-0° (E) (E) (E) - 8 (E) (E) • . <br /> EXISTIN�EXTERIOR L{GHTING <br /> z0.2 FOOT CANDLE PER SF MINIMUM 05A 3'-0" 7'- 0° (E) (E) (E) - 1 (E) (E) ' <br /> � . NOTES: 06A 3'- 0" 7'-0" �E) �E) �E) - � �E) �E) ��ccY <br /> 0 • FURNISH AND INSTALL R11 SOUND BATT 07A 3'-0" 7'-0" A WD ST - 1 7/A0.12 2/A0.12 REINSTALL SALVAGED SOLID FLUSH DOOR FROM ��e� <br /> INSULATION IN NEW WALLS AND ON TOP OF EXISTING SPACE CHECKEDBY , <br /> OFFICE OFFICE ACT C�ILING A7'NEW WALL LOCATIONS ONLY. osA 3�- o° ��-o° (E� �E� (E� - � (E� �E) CMR <br /> 09A 3'- 0" 7' - 0" A WD ST - 1 7/A0.12 2/A0.12 REINSTALL SALVAGED SOLID FLUSH DOOR FROM CHcCKED BY <br /> „ 16 ALL GLAZING IN DOORS TO BE LAMlNATED EXISTING SPACE SC <br /> • ., <br /> 514 SF <br /> . __ SAFETY GLASS PER DOOR SCHEDULE ON 09B 3�-o�� 7�- o�� (E� �E� (E) - 6 (E) (E) <br /> - THIS SHEE7. �oa 3'-0" 7'-0" (E) (E) (E) - 1 (E) (E) <br /> \ /�� 11A 3'- 0" 7'-0° (E) (E) (E) - 3 (E) (E) � <br /> V ¢ � ', 12A 3'-0" 7'-0" �E) �E) �E) - 5 �E) �E) . . <br /> � COLLABORATION � �3A 3'-0" 7'- 0" (E) (E) (E) - 5 (E) (E) <br /> zs 14A 3'-0" 7'-0° �E) �E) �E) - 6 �E) �E) ' • <br /> � 15A 3'- 0" 7'-0" F WD/ ST - 5 7/A0.12 2/A0.12 REINSTALL SALVAGED FU�L LITE DOOR FROM EXISTING <br /> LS SPACE <br /> N N � � 16A 3'- 0" 7'- 0" F WD/ ST - 5 7/A0.12 2/A0.12 REINSTALL SALVAGED FULL LITE DOOR FROM EXISTING <br /> LS SPACE . <br /> STORAGE • <br /> zZ 17A 3'-0" 7'-0" F WS/ ST - 5 7/A0.12 2/A0.12 SPACE ALL SALVAGED FULL UTE DOOR FROM EXISTING <br /> MAW LOBBY <br /> 11A 20A 3'- 0" 7'-0" A WD ST - 4 7/A0.12 2/A0.12 REINSTALL SALVAGED SOLID FLUSH DOOR FROM ; <br /> �- � - - - - � Ex o �- - - - - - - -� EXISTINGSPACE : <br /> , � ��+�,,1 � �, � � O � � � REF 15A 22A 3'-0" 7'-0" A WD ST - 6 7/A0.12 2/A0.12 EXISTING S ACEAGED SOLID FLUSH DOOR FROM <br /> � � � I ! I - <br /> � � womeN'S RESTROOM � � nneN'S RESTROOM I N/ELLNESS OFFICE 23A 3'- 0" 7'-0" A WD ST 8 7/A0.12 2/A0.12 REINSTALL SALVAGED SOLID FLUSH DOOR FROM <br /> I EX I � EX EXISTING SPACE <br /> � 20 15 <br /> � � � uP � ; � <br /> � , <br /> i � I � � i 1 2oa - GENERAL DO�R �i�T�S: <br /> � � � � � - . <br /> � -� - - - - - - - - - - - - � OPEN OFFICE <br /> � CASED OPENING PA"rRY '� 1. SUITE ENTRYIEGRESS DOOR LOCKS AND LATCHES TO COMPY WITH IBC AND LOCAL CODES.ANTI-PICK LATCH MECNANISMS ARE <br /> CORRIDOR 21 PROHIBITED. � <br /> 3 Ex 4 2. ALL LOCKSETS SHALL BE COMPATIBLE WITH BUILDING MASTER KEY SYSTEM.ALL LOCKSETS SHALL BE KEYED INDIVIDUALLY.GC TO U <br /> A2.11 A2.11 Q �❑ VEND COORDINATE KEYING WITH PROPERT MANAGEMENT AND TENANT. LOCKETSET FINISH: SATIN NICKEL OR EQUAL. � . <br /> o MW pW REF ^ ` <br /> ' � � 3. IF ACCESS CONTROL DEVICESD ARE IN SCOPE OF WORK,CONTRACTOR TO COORDINATE AS NECESSARY TO PROVIDE PERMITS �r <br /> � REQUIRED BY LOCAL JURISDICTION(LE. RELEASE RELAY SWITCH WHEN MAGLOCKS ARE USED. � >- '� <br /> � 7ELEIDATA � • <br /> L TESTING EX 4. GC TO FURNISH AND INSTALL HARDWARE SETS(U.O,N.) � � � <br /> � 02 <br /> � RecePrioN 5. GC TO COORDWATE WITH PROPERT MANAGEMENT TO SALVAGE ANY EXISTWG DOORS FOR POTENTIAL RE-USE WITHIN THEIR W � <br /> 0 0� � BUILDING. U � ' . <br /> �= o � ❑ � 6. ALL WOOD DOORS TO BE 3'-0"x7'-0"(U.O.N.)SOLID CORE 1-314"THICK MOHAWK PREMIUM 2000 PRE-FINISH, STAINED DARK BROWN � � � � <br /> � � i�� OR APPROVED EQUAL TO MATCH PL-3, MINIMUM(2)COATS STAIN AND(2)COATS SEMI-GLOSS POLYURETHANE. � � � � <br /> .O �� OZ� EQUIPMENT � . <br /> Q 7. SUITE ENTRY GlASS DOORS TO MATCH HEIGHT OF BUILDING STANDARD LOBBYICOMMON CORRIDOR DOORS. � L�1/J � <br /> L 14 � LL. � <br /> o ` i i 03 8. ALL LATCH&LOCK SETS TO BE AN ADA COMPLIANT LEVER. � W> � ' <br /> O p o INTE� I � n . <br /> �p I � 9. CENTERLINE OF PUSHER STRIKE TO BE AT 40 A.F.F.AT ALL DOORS W/PANIC HARDWARE. �J <br /> 03 � <br /> � � � � . <br /> � 10. FILM ON GLASS INSERT LITE IS 3M FASARA GLASS FINISHES, COLOR MILY WHITE(MILANO) o � � <br /> c� � � � � <br /> � � <br /> � 11. BUILDING INTERIOR EXIT ENCLOSURE DOORS SHALL HAVE A MAX.TRANSMITTED TEMPERATURE RISE OF NO MORE THAN 450 � � O � <br /> �o < DEGREES F°. o � � � <br /> � 1 B a �-- � • <br /> � 12. 20,45, 60,90, 180 INDICATES MINUTES OF FIRE RATING. . <br /> � PROJECT NO. <br /> �� m o DOOR P�A�I�L TY��S 1908 ' <br /> � OFFICE <br /> � 6,� 10" 4,� 6,� <br /> � �p i -� ��� � ISSUE DATE <br /> N � <br /> -----,t- --_- - <br /> . � � i ii � ' ^ � . <br /> `° RATED � ; 05/14/2019 <br /> - ° c NFERENCE FLUSH � � NARROW LITE � ; ; � � NARROW LITE ;�� � � <br /> ,_., ; _ � � ; _ � �'� � c=i CURRENT REVISION <br /> O �� i � ��E " � v�i sw�,�_ i v� <br /> 04 q ; w B � w C ' � PERMIT � <br /> u> � a ����E - � a �a a�- ' <br /> � � ����� � � � ' �� � ' C� � ' REVISIONS � <br /> � --- -�- --- •-- --T, <br /> u� � A5. 1 3 10A N � ���` �fi -1`-'� � <br /> U � r- PERSCHED PERSCHED PERSCHED <br /> N � <br /> +-� <br /> � , <br /> U ' <br /> � STORAGE <br /> Q . <br /> � INTERVIEW WTERVIEW EX OFFZCE OFFlCE $" IB„I I� I� i <br /> U - - <br /> � fi�--- <br /> 0 07 09 o HALF LITE ;--�� SLIDWG LITE FULL LITE ;--; '�'i��' <br /> � � m ❑ �-- ' � o ; i � o <br /> Q Q � ' _ ; ' � T <br /> Q d- � � _��- � � ��,�E % �' =�G�E � , � � <br /> 0 0 0 _ _ o � � E � � <br /> Q ---- =--- � a �-' � � a ;., <br /> � � ELECTRICALROOM �` �ua�E �D � �O10L_ EE o��E F� � -� ���, <br /> .� EX <br /> � ----'- � ; <br /> � EXISTING EXTERfOR LIGHTWG �-� <br /> � 09B 0.2 FOOT CANDLE PER SF MINIMUM <br /> PER SCHED <br /> SYMBOL I NO.I DESCRIPTION I DATE <br /> � � � � U �VOR AB�R�d Il�1�I�IdJ KEY PLAN <br /> � <br /> � <br /> � o 0 0 o LOBBY DOOR CONSTRUCTION DOOR�INISH GLAZING ' . <br /> 0 <br /> Ex AL-ALUMINUM PT-PAIN7ED CG-CLEAR GLASS <br /> v`�i EX-EXISTING DOOR/FRAME CL-CLEAR FINISH ILS-INSULATED LAMINATED SAFETY <br /> � CORRIDOR AREA OF WORK <br /> p INTERVIEW INTERVIEW INTERVIEW EX HM-NOLLOW METAL MF-METAL FINISH LS-LAMINATED SAFETY GLASS <br /> Q � <br /> ,� 05 os os �P SC-SOLID CORE WOOD ST- STAINED WITH CLEAR FINISH TS-TEMPERED SAFETY GLASS � � <br /> o ST-STEEL FF-FACTORY FINISH � � <br /> OURYYAR� <br /> c WM-WELDED WIRE MESH � � <br /> � <br /> , � � �J WD-WOOD � � <br /> }, � WV-WOOD WI VENEER <br /> .� � . <br /> � �/4�D�/��� ��T $����U�.� <br /> � <br /> � <br /> � $ET#� SET#4 SE7#7 SHEET NAME <br /> 'a� 3 HINGES 3 HINGES 1 SET TOP&BOTTOM PIVOTS <br /> � 1 PASSAGE LATCHSET 1 PRIVACY LOCKSET W/ INTEGRAL 1 STOREROOM LOCKSET ON F LO�R P LAN . , <br /> -� 1 FLOOR STOP OCCUPIED INDICATOR ACTIVE LEAF <br /> � 3 SILENCERS 1 FLOOR STOP 1 DUMfv1Y PULL ON INACTIVE LEAF � <br /> a N 3 SILENCERS 1 FLUSH BOLT ON INACTIVE LEAF <br /> o SET#2 ACCESS CONTROL OVERHEAD <br /> 1 COAT HOOK 1 PASS THROUGH HINGE W! <br /> •� �FLOOR PLAN 6 HINGES 1 OVERHEAD CONCEALED <br /> � � 1/8"= 1'-0" 2 HALF DUMMY TRIMS SET#5 CLOSERS �° <br /> • � O� 4� $� 16� 32' 2 HEAVY DUTY ROLLER CATCHES 3 HINGES ��"�'��' �� �'����Y��� <br /> 2 HEAVY DUTY CONCEALED 1 PRIVACY LOCKSET <br /> @ � DOORSTAYS 1 FLOORSTOP SET#8 �����U�I�� ��� ������ <br /> � U <br /> � <br /> 3 SILENCERS 3 HI <br /> � U S�T#3 1 FLOOR STOP <br /> � L 1 COAT HOOK 3 �SILENCE SM <br /> � Q 1 PAOREHA�DW RE WELOCKING SET#6 <br /> � U TRIM AT CORRIDOR SIDE 3 HWGES 1 CLOSERS SHEET NUMBER • <br /> � � 2 KICKPLATE 1 STOREROOM LOCKSET <br /> � ° 1 WALL STOP 1 KICKPLATE <br /> � .0 3 SILENCERS 1 FLOOR STOP <br /> � � 1 CLOSERS 3 SILENCERS <br /> � L <br /> 0 1 CLOSER(PULL SIDE) <br /> � � <br /> •- � <br /> � � <br /> F- ca <br />
The URL can be used to link to this page
Your browser does not support the video tag.