My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1604 HEWITT AVE 2016 SKOTDAL REAL ESTATE Plans 2023-04-21 (2)
>
Address Records
>
HEWITT AVE
>
1604
>
SKOTDAL REAL ESTATE
>
Plans
>
1604 HEWITT AVE 2016 SKOTDAL REAL ESTATE Plans 2023-04-21 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2023 3:16:04 PM
Creation date
10/29/2020 2:23:16 PM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1604
Tenant Name
SKOTDAL REAL ESTATE
Permit
B1612-034
Year
2016
Notes
TI RESTROOMS OFFICES SHOWER
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. __.. .._� _I�I-- - <br /> .'� <br /> DEVICES SHOWN � - � <br /> — 25 GA. RUNNER STACKED IN PLAN � <br /> WHERE OPENING ARE TO ALIGN VERT. i AT LOCATION AS DIMENSIONED ON <br /> EXCEEDS 4'—fi" BOTtOM OF FlNISHED CEILING AS SHOWN BELOW 1 PIAN; OR NEXT TO DOOR / <br /> OPENING AS DIMENSIONED BELOW � • <br /> BOTfOM OF 6M FlRE ALARM STR08E <br /> SCHEDULED CEIUNG ;r; �� ��' � <br /> FRAME WHERE OCCURS � <br /> REIN ORCEMENT, TYP. — UP TO 4'-6" A�AX: � ROOM SIGNAGE, ETC. <br /> RUNNER TRt�K . <br /> UP TO 8'-0 MAX: I THERMOSTAT R E /� � E S T A �' E <br /> DOUBLE 25 6A. <br /> I <br /> — — — — & RUNNERETRACK I � CLIENT: :` �� � <br /> ACOUSTIC INSULATION � � � LIGHT & PROJECTION SCREEN , <br /> i i I OCCUPANC WSE S RUN� SKOTDAL REAL ESTATE <br /> I I 3'—o"to 4'—s`MAX: ao i �m 1604 HEWITT AVENUE <br /> - � � ANCHOR BRACKET: i ' <br /> � � QQUBLE STUDS 6'7(16ga UNPUNCHED � CARD READER WHERE 2ND FLOOR <br /> � • � � � 4'-1"to 8'-0"MNc: STUD TRACK, ATTACH Q I ,L� OCCURS EVERETT, WASHINGTON 98201 <br /> DOUBLE 25 GA. TO 3 STUDS MIN o = � <br /> I I MTL. STUDS � `� N � HARDWARE LATCH <br /> METAL STUDS � � "' M ° ° � <br /> I I ( FlNISNED FLOOR <br /> I � <br /> I I <br /> . � DOOR FRAME TELEPHONE OUTLET <br /> . ...... . . . . . . . : ... . <br /> I ( TOP OF SLAB ELECTRICAL OUTLEf � <br /> >.. 5/8° 6YP. BOARD � � <br /> �� � --- BOTTOM RUNNER ` , . <br /> NOTE: 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLEfS AT <br /> METAL STUDS 12 x 25 GA. COORQINATE ANCHOR 3 STUDS NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY . <br /> AS SCHEDULED ANCH4R ANGLE BRACKET LOCATIONS W_/ MIN. DIMENSIONED ON PLAN, ELEYAl10N, OR LOCATION AS PER DIAGRAM ABOVE. <br /> CASEWORK & EQUIPMENT 2. CENTER FlRE ALARM STROBES DIRECTLY ABOVE FlRE EXTINGUISHER � <br /> � 25 GA. STUDS WHERE SCHEDULED, AND FINISHED FLOOR CABINETS WHERE B4TH OCCUR. <br /> MANUF. �iOUNTiNG INSTRUCTIONS l���ll=�:ii���i� � <br /> TYP. PARTITION INTERSECTION FRAMING TYP. FRAMING C� DOOR OPENING STANDARD BLOCKING DETAIL STANDARD MOUNT HEIGHTS ARCHITECTS <br /> NTS NTS D NTS <br /> NTS � �/ <br /> A WEAVER ARCHITECTS, INC. <br /> 1411 FOURTH AVENUE, SUITE 810 " <br /> SEATTLE, WASHINGTON 98101 <br /> P. 206.262.9622 , <br /> ` � � � BRACE & SECURE TO STRUCTURE BRACE & SECURE TO STRUCTt1RE F• 2 0 6.2 6 2.9 5 0 7 <br /> P� Q�l�� {f�A,9.2 PER DEfAIL K/A.9.2 All reproduction & intellectuai property rights reserved c 2016 � <br /> BO�TOM OF 1 <br /> STRUCTURE � 4 <br /> � 12" LEG AT <br /> STRUCTURE — ATfACH i � � <br /> WHERE PART. TYPE IS W/2 POWDER DRIVEN PROVIDE ENCAPSULATED ACOUSTICAL � � <br /> INSULATED FASTENERS PER BRACE BATT EXTENDING 24' BEYOND EACH <br /> PROVIDE ENCAPSULATED 2 �/2"x20 GA MEfAL SIDE OF PARTI'fION <br /> ACOUSTICAL BATT EXTENDING 24" WHERE PARTITION TYPE IS INSULATED, <br /> PER PLAN EACH SIDE OF PARTITION. � STUD BRACING � PROVIDE ENCAPSULATED ACOUSTICAL BATT <br /> 48" OC TO STRUCTURE <br /> � EXTENDING 24" BEYOND EACH SIDE OF <br /> PARTfi10N <br /> . <br /> Professionol seai <br /> �o �o iQ� � REGISTERED <br /> � ARCHITECT <br /> SUSPENDED CEILING AS <br /> SCHEDULED ' ` �� � . <br /> � ER <br /> S ATE F WASHINGTON � � <br /> � ' <br /> ` �, �, �. MATCH B/S HEAD CONDITION �Y 7��Q��� <br /> � SUSPENDED CEILING AS SCHEDULED �� GRID SPACER � SUSPENDED CEIIJNG AS SCHEDULED � SUSPENDED CEIUN6 AS SCHEDUIFD <br /> + - No. Issue Description Date . <br /> � MATCH B/S HEAD CONDITION A�TACHED�O gOP��TNRGACK NEW WALL ANGLE EA. SIDE UPDATED DD SET 01.25.16 <br /> , <br /> + <br /> Wj2 SELF—TAPPING SM. PRICING SET 03.03.16 <br /> SCREWS � 48"oc, AND <br /> 3/4" PIPE SLEEVES FINAL PRICING SET 05.09.16 <br /> PERMIT SET 12.19.16 <br /> EXISTING EXTERIOR AND/OR CORE WALL PARTITION lYPE FRAMING -- � <br /> 20: 2-1/2" X 2Q GA STUDS � 24' O.C. � � <br /> MAX HEIGHT OF 12�-3" <br /> 20A: 2-1/2� X 20 GA STUDS � 24" O.C. 3-5/8° X 20 GA METAL <br /> MAX HEIGHT OF 12'-3° STUDS � 24" OC. . <br /> 20 GA. METAL STRAPPING 206: 3-5/8° X 20 GA STUDS � 24" O.C. <br /> SECURED FROt� EXISTING MAX HEIGHT OF 16'-0° STAGGERED 3-5/8" X 20 GA. � <br /> PARTfTION TO EACH FURRING ACOUSTiC INSULATION UNLESS OTHERWISE METAL STUDS � 24� O.C. <br /> STUD ACROSS NOTED ON PLANS <br /> � 2 1�2" X 20 GA METAL PARTITION 1YPE SHE4THING Drawn by: ALJ Reviewed by: <br /> STUDS � 24" OC. MAX. P 20: (1) LAYER 5/8 TYPE 'X' GYPSUM � . <br /> „ STUD HEIGHT OF 12'-4'. --� BOARD ON EACH SIDE OF STUDS � Pro�ect No: # 15-185-00 , <br /> �/2 - ACOUSIIC INSULATION UNLESS OTHERWISE • <br /> MIN. 20A: (1) LAYER 5/8 TYPE 'X' GYPSUM 1 IAYER 5/8" �YPE "X" NOTED ON PLANS <br /> 1 LAYER 5/8° iYPE "X° GYP. BD. 84ARD ON IXPOSED SIDE OF STUDS pF M�q� g�pg E 1 IAYER 5/8" TYPE 'X" GYP. BD. EA. <br /> — SIDE OF METAL STUDS PARTITION TYPE S / <br /> 20B: (1) LAYER 5 j8 TYPE �X' GYPSUM . <br /> BOARD ON EACH SIDE OF STUDS FRAMING DETAILS <br /> ACOUSTIC INSULATION UNLESS OTHERWISE ACOUSTIC INSULATION UNLESS OTHERWISE ' <br /> NOTED ON PLANS NOTED ON PLANS <br /> FASTENER 0 24" OC FASTENER � 24" OC <br /> FASTENER 0 24" OC <br /> FASTENER � 24tl �C Original drawing is 24" x 36". Scale entities accordingly if reduced <br /> + MET. RUNNER 1RACK MET. RUNNER TRACK MET. RUNNER TRACK 6" MET. RUNNER TRACK ; <br /> � A /'� ' � � <br /> � ACOUSTIC SEAIANT ACOUSTIC SEALANT ACOUSIIC SEALANT �-- ACOUSTIC SEALANT j� . � . L <br /> + � � � L 1 <br /> PRONIDE I�.R. GWB AT r CONCREfE SLAB / CONCREFE SLAB <br /> CONCRETE SlA6 CONCRETE SLAB �� � ��q, � <br /> �E. �. AT IILL � � Permit Agency , <br /> lYPES, U�i r` <br /> , <br /> PARTITION PARTITION � O p �PEITION � O �PEITION �O <br /> nPE: � o -�PE: 2 0 , 2 0�, & D , <br /> PARTITION FURR OUT - NON RATED PARTITION TO TEGULAR APC PARTITION THRU TEGULAR APC ACOUSTIC PARTlTION THRU CEILING � � . <br /> L M : . <br /> J <br /> K . <br /> �� <br /> . :. : <br />
The URL can be used to link to this page
Your browser does not support the video tag.