Laserfiche WebLink
�F, I • • <br /> . . . . . r . ' ' . <br /> � ' <br /> . 1 <br /> FASTENING SCHEDULE MATERIAL LIST <br /> WALLS' FLOOR: <br /> ROOF: <br /> PLATE—TO—STUD MIN. OF 3 — 0.121"x3" NAILS 2 x 8 FLOOR JOIST—TO—RIM MIN. OF 4— 0.131" x 3" NAILS ROOFING. .. . . .. . . .. . .ARCH. SHINGLES OVER SELF—ADHERED <br /> VW TACKBOARD—TO—STUD C�? INTERIOR SENCO P15 STAPLES & GLUE CLASS "A" BOTTOM BOARD—TO—JOIST 16 ga. x 3/8" WIDE CROWN � 12" MAX. EDGES ONLY UNDERLAYMENT APPLIED SHINGLE FASHION <br /> SHEETROCK—TO—STUD Cs� INTERIOR 13ga.x1 5/8" SHEETROCK SCREWS AT 16" oc EDGE FLOOR DECKING—TO-2x JOIST 0.113" x 2 3/8" RING SHANK � 6" EDGE, 12" IN FIELD. USE —HIGH WIND APPLICATION— <br /> AND CONSTRUCTION ADHESIVE IN FIELD. CONSTRUCTION ADHESIVE ON JOISTS <br /> BOTTOM PLATE—TO—FLOOR 0.131"x3" NAILS � 8" oc. SHEATHING. . . . . . . .. . .7/16" APA RATED (24/16) MINIMUM <br /> FRAMING . .. . . .. . . .. . .2 x 10 HF #2 RAFTERS � 24"oc <br /> SHEATHING—TO—STUD AT SIDEWALL 16 GA. x �3�4" STAPLES � 6"oc EDGE, 12"oc FIELD ROOF: w/ 2" FURRING ON BOTTOM <br /> ALL EDGES SUPPORTED BY FRAMING OR BLOCKING FURRING—TO—RAFTERS MIN. 4— M20 2 x 3 (MIN.) PLATES EACH SIDE <br /> RIDGEBEAM . . . . .. . . . .DOUBLE 1 1/2" x 24" CONTINUOUS LVL 2.OE <br /> SHEATHING—TO—STUD AT ENDWALL SEE ENDWALL FASTENING NOTES ON ELEVATIONS ROOF RIM—TO—TOP PLATE 0.131" x 3" NAILS � 8" oc. <br /> LEDGERS. . . . . . . .. . . . .2 x 4 D.F. TAPER CUT <br /> LAP SIDING FASTENED PER MANUFACTURER SPEC. LEDGER—TO—RIDGEBEAM 0.131" x 3" NAILS � 3" oc & 3 � BUTT JOINTS <br /> RIMS. . . . . . .. . . . . . . . . .2 x 6 CONTINUOUS LVL 2.OE <br /> THREE STUD CORNER CONNECTION 0.131"x3" NAILS � 12"oc. RAFTER—TO—RIDGEBEAM 4— 0.131" x 3" NAILS WITH 2 x 10 DF VENT BLOCKS <br /> RIDGEBEAM—TO—RIDGEBEAM 4 ROWS @ 0.131" x 3°' NAILS � 12"oc INSULATION. . . . . . . . . .R38 CELLULOSE BLOW—IN OVER CLASS "A" <br /> MATERIAL (AIR BARRIER COMPONENT) <br /> AIR BARRIER NOTES: SHEATHING—TO—ROOF MEMBERS 16ga x 13/a�� STAPLES � 6" EDGE, 12" IN FIELD <br /> NOTE: SHEATHING TO BE INSTALLED PERPENDICULAR TO THE RAFTERS. OFFSET CEILING. . .. . . .. . . . . . .SUSPENDED T—BAR (PER IBC 808) <br /> "ARMSTRONG SEISMIC RX CEILING" <br /> THESE KEY AREAS SHALL BE SEALED BY CAULKING, GASKETS, TAPE OR WEATHER—STRIPPING: SHEATHING 4 ft. BLOCK EDGES OF ANY PIECES LESS THAN 24" <br /> —JOINTS AROUND FENESTRATION (WINDOWS AND DOOR FRAMES): USE APPROPRIATELY SIZED BACKER ROD WITH MINIMUM ARCHITECTURAL . . . . .12" OVERHANG � <br /> 2' LAP AT ENDS. <br /> —JUNCTIONS BETWEEN WALLS AT: SOFFIT. . ... . . . . . .. . . . .y4" FIBER CEMENT PANEL, PERFORATED FOR <br /> —BUILDING CORNERS: USE CAULKING MODLINE CONNECTION: NOTE: A�� MODLINES (DEFINED AS THE SPACE BETWEEN ADJOINING MODULES) VENTING AS REQUIRED <br /> —STRUCTURAL FLOORS: USE SILL SEAL OR CAULKING MUST BE INSULATED AT THE ROOF, FLOOR AND WALLS ON SITE. <br /> —ROOFS (AT RIM): USE SILL SEAL OR CAULKING VENTING. . . . . . . .. . . . .SOFFIT AND RIDGE <br /> —PENETRATIONS OF UTILITY SERVICES THRU THE AIR BARRIER � ROOFS, WALLS, AND FLOORS: USE CAULKING, SPRAY RIDGEBEAMS 1/2" BOLTS w/ 1 1/2" DIA. WASHERS � 6'-0" oc AND 8" FROM EACH <br /> FOAM, OR AIR BARRIER TAPE. END (MINIMUM 2" EDGE DISTANCE) <br /> —BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS: USE BACKER ROD, CAULK, SPRAY FOAM OR AIR BARRIER TAPE. RIM JOISTS 1/2" BOLTS w/ 1 1/2" DIA. WASHERS � 4'-0" oc AND 8" FROM EACH <br /> —JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDANTS: USE CAULK OR APPROVED TAPE. END (MINIMUM 2" EDGE DISTANCE) • <br /> —RECESSED LIGHTING FIXTURES: USE CAULK OR SPRAY FOAM SIDING. . . . .. . . .. . . . . .FIBER CEMENT �AP SIDING WITH <br /> 8" EXPOSURE OVER BUILDING WRAP. <br /> BUILDING WRAP TO EXTEND TO BOTTOM OF <br /> FLOOR RIM (MIN.) <br /> SHEATHING. . . .. . . .. . .Y2" CDX PLYWOOD (MIN.15/32" RATED SHEATHING) <br /> C <br /> g A FASCIA. . . . . . . . . . . . . .1 x 6 <br /> 4 6 TRIM . . .. . . .. . . .. . . .. .1 x 4 AT CORNERS, <br /> � � A-4 A-4 WINDOWS, DOORS AND 1 x 6 � MODLINE <br /> � NOTE:2"x 2" GALV. FLASHING UNDER CORNERS <br /> SHIP LOOSE TO BE INSTALLED ON SITE BY <br /> I OTHERS <br /> � � 12 2 3 2 FRAMING. .. . . .. . . .. . .2 x 6 D.F. #3 or BETTER STUDS � 16"oc <br /> LU26 HANGERS AT ALL RAFTERS _ � ; � ; � A-4 A-4 <br /> ;� OVER DOOR & WINDOW OPENINGS _ � I' _— (�� <br /> WITH 6— 0.131" x 1�,�" NAILS I � / • j�, TOP PLATE. .. . . .. . . .2 x 6 CONTINUOUS LVL 2.OE <br /> I \� � � ' �\ �\ � /�/���./���%�/��/ � . Y � — � <br /> - \ �1 � 'ji I ' RIDGEBEAM BRACING �� � - I I � % I�%�/ / BOTTOM PLATE. . . .. .2 x 6 D.F. <br /> INTO LVL ROOF RIM � � �\ <br /> � Ii I1 \� �' I I iij� /I- �,;.;,;::,, � <br /> SEE DETAIL I � /I I/ , <br /> -:-.:_;.:: I\' � I x ATION <br /> '; \ �\i �\ �' � �� 5 ,,:>. INSUL . .. .. . R-21 FIBERGLASS BATTS PLUS <br /> :.... . , � <br /> *� � _ <br /> :;;-<:.::::...:.::::::::... <br /> A-4 ii � Y2" (R3 MIN.) CONTINUOUS FOAM BOARD AT <br /> _..: <br /> _-- -:.._.:.:::. <br /> � INTERIOR SIDE OF EXTERIOR WALLS ` <br /> 12�'� � INTERIOR FINISH. . .. . .MATERIAL INSTALLED FROM STUDS OUT <br /> SEAL 6 FT. WIDE WINDOWS � FLAME SPREAD \ EXT. WALLS:LAYER 1: FOAM INSULATION BOARD <br /> AT ROOF IS 25 OR LESS � � LAYER 2: 5/$" TYPE 'X' SHEETROCK (AIR BARRIER) <br /> RIM/TOP y } —USE 2— 2x6 D.F. #2 w/ MIN. R10 RIGID FILLER <br /> PLATE —USE �2� FULL HEIGHT STUDS AND Q LAYER 3: Yz" VINYLWRAP TACKBOARD (FINISH) <br /> �1� TRIM STUD AT EA. SIDE OF WINDOW w � ABOVE WALL FINISH: LAYER 1: Yz" FOAM BOARD <br /> o AT GABLE ENDS LAYER 2: 5/$" SHEETROCK <br /> �ICO BACKER i — <br /> � ROD : � i SKIRTING . . . . . . . . . . . . .SHIP LOOSE <br /> I AROUND = p <br /> INTERIOR ONE DRY CUP PERM VAPOR � <br /> `— SIDE OF z o BARRIER ON THE WARM SIDE, `� FLOOR: <br /> `,— WINDOWS !, ', J � i TYPICAL THRU—OUT BUILDING. � <br /> � AND DOORS ! w <br /> COVERING, .. .. . . .. . ON SITE BY OTHERS <br /> ao ; ; o c� m :� ' .. <br /> ' I o � DECKING. .. . . . . . . .. . .23/3z�� APA RATED T&G — GLUED AND NAILED <br /> � � � , (AIR BARRIER COMPONENT) <br /> CAULK WALL � � <br /> CORNERS FROM � FRAMING. . . . . . . .. . . . .2 x 8 HF #2 JOISTS � 16"oc <br /> TOP TO BOTTOM - <br /> AT INTERIOR � <br /> � RIMS. . . . .. . . .. . . .. . . .2 x 8 CONTINUOUS LVL 2.OE <br /> NOTE:12" HIGH MOISTURE BARRIER INSTALLED ON <br /> ` ' � PERIMETER (OVER GYPSUM) AT RIMS AND END <br /> SEAL A-4 JOISTS <br /> AT FLOOR � 3 4 <br /> P ATBOTTOM //� � A-4 A-4 / JOIST HANGERS. .. . . .AT ALL RIMS <br /> \ <br /> _ � INSULATION. . . . . . . . . .R-30...USE TWO LAYERS OF R-15 <br /> op �I ����ill��,���'�I����i �i�� ii��l �i��i I�� ��Ii i � � �II��I�i�i�i��ii��I���iI� �!i�II���I ����i����I � � � UNFACED FIBERGLASS BATT FIBERGLASS <br /> ^ � � � BOTTOM COVER. . . . . .CLASS A <br /> \\ �� �� �� <br /> �" SPACE 2-10-2016 <br /> 13'-10" 13'-10" I�. SRF <br /> �G�o� wns,�j cl�,� <br /> w � <br /> H y � <br /> � <br /> � '� <br /> �l <br /> �'�� � 35006 9 ,�'�C�� <br /> SECTION - A A �� ��ISTER� �� <br /> Ssj�NAL ti�� <br /> 1/2" = 1'-0" <br /> COPYRIGHT 2016, BLAZER INDUSTRIES, INC. � MODULAR C/assroom for. Approved for Const: Job No. 18567 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES, INC.AND SHALL �� 28 X 32 KC DA � EVe rett S�D■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED �� INDUSTRIES,irvc. <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE Drawn By: JwR � <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� P,O.BOX489 ■ Aumsvi��e OR97325-0489 WA. GOLD Pacific Mobile 14 BLMP-11 A3 Everett, �/A Issue Date: 02/01/16 <br />