52'-0" 52'-0"
<br /> 25'-0" 13'-5 1/2" 13'-6 1/2" � '��,
<br /> 2'-0" 23'-0" 13'-5 1/2" 13'-6 1/2"
<br /> '���`+�/ �
<br /> O
<br /> U
<br /> s }�� � .
<br /> �/.�t `� �
<br /> � �
<br /> 5W6
<br /> 2668 5W6 6050R5 - _ 4040R5 _- --.-- ----- 5W6 _ -_ � � � � -�p
<br /> �'" O � Y
<br /> � � � � O
<br /> 2868 5�6 2030R5 5W6 � 5W6 2030R5 5W6
<br /> � � >� O
<br /> � •� > .Q
<br /> � � - . � •vi�� � �
<br /> D
<br /> ' � � � � � ��
<br /> 0
<br /> � � RY F N D s � 9'-10 1/2" 3'-S" � � p Q J
<br /> E L D ; (s)2x ro(E) (E) M5T B�4. � 2668, � ��� � � �
<br /> � ) (E) W.I.G.
<br /> 11'-2" x 7'-8" u � °� (E) B,�TH � � � �
<br /> � � 3
<br /> �
<br /> (E) B�TH 6'-8" 3'-21/2"�3'-8" � 5W6 a� 3 > W
<br /> 3 1/2"xl" P.S.L GO o q�-(��� �C (�-��� SWb 4050R5 � ____ 4046R5 � '� � Q d'
<br /> _.__
<br /> cv '— � � -� � � pp M
<br /> TO NEW FTG. BELOW ° _�-- � � °� *-' �
<br /> -
<br /> ----- �
<br /> — --
<br /> 2868 0 5D I i ' 2668 2668 _ � � �
<br /> � � �
<br /> 3 �r � i 4068 3 `Y' N �
<br /> "' X ' � 5D N CO
<br /> p� � 4 U� �' �= A I� _ _ N ir'�N O 4 TYP � � � O
<br /> _ �v_ P` 3 0 3
<br /> �
<br /> — - v
<br /> 3 NEW STAIRS �i- 3 5D W
<br /> ,yb`0� WALL >� 4068 O � Z
<br /> v (5)2x TO(E) � � So6. OPEN RAI 4 �P iti O
<br /> �� e � a
<br /> ir�
<br /> I� � I� " �' ��, ?'-1 1/2" FND. �I � `n �
<br /> ' I I I' �' � (5)2x TO(E ND. � _ O° o �I
<br /> , , � ; � � 5D 4 NEW LOFT �o i ;� .
<br /> ;
<br /> � -
<br /> �
<br /> ' �� �� ,-' �' � �� � (3)2x TO(E)FND. `" �
<br /> �
<br /> o � \���� 2668 �
<br /> � o (E) KITGHEN �
<br /> �, (E) M5T SED o �'
<br /> (7'-9"GLG.) 5 1/4'k9 1/4" P.S.L VERIFY(E) _— O D ' t '
<br /> NEW(2)l"x9 1/4"P.S.L.w/(2) 4x8 FiDR ��•J
<br /> `� 1 3/4"x9 1/2"L.V.L. BOLTED w/ U
<br /> � ce��A5��P OPEN BELOY�I
<br /> ry (E)J5T5(YERIFY) 5/8"DIA.THRU BOLT5 @ 32"o.c. ) �NTRY ! _ � 2668 2668 �
<br /> q�_ �� X ,��_ 0 9'-1" X 14'-7" ry O '
<br /> (E)J5T5(VERIFY) (3)2x TO(E)FND. � `� � v SD I
<br /> W �
<br /> ' 0 5068 ry Q �
<br /> .� �I E B E D
<br /> � � _ _ � O _ Q
<br /> a
<br /> -- (E) LIYING �
<br /> b'-5 1/2" 3'-9 1/2" 3'-9" (�
<br /> 51/4"x51/4"P.S.L. �E� D���N�7 ', 6068 '(9'-0"GLG.)��'-2" 6030FX ���( BED , � "� �
<br /> � � w � �
<br /> TO(E)POST BELOIN (7'-9"GLG.)�a�-O�� � �~� '��.�� ��:.;�� '
<br /> , � � 0
<br /> , � O _ � � � ��
<br /> z � (n T '�"'�
<br /> — - � ^,
<br /> 8050T5 - I�i {1)G516 @ WINDOW 8068 _ �
<br /> 5W6 0 � m Z �L W
<br /> 5W6 SWb � 5W6 �
<br /> � I OPENING PER Z1l51 � d' � � � W � J W � �
<br /> � � ux_ � � -
<br /> 0 0 - (E) DEGK W �
<br /> � m o a � � � � � � '� a � �
<br /> � � QoW
<br /> (E) DEGK PA�TIO � � �
<br /> — ------ ________ --- - , S' 10" X 11'- 0" _ � � � � �
<br /> , , �� � „ �
<br /> � nx:.,�.�,n�a.�� �..�kv�,���,. �, �'�/
<br /> , � -- — L
<br /> 8050T5 I ,o - 5W6 6050R5 L�.�
<br /> 5W6 ��
<br /> � ry
<br /> SWb 5W6 N ~
<br /> (1)G516 @ WINDO ______ ______
<br /> -- --
<br /> �' ---- �
<br /> OPENING PERZ1/51 � 805 5H 804 TS �
<br /> 5W4 5W4 5W6 5W6
<br /> ,�_o�. ,�_o�. UPPER FLOOR PL N
<br /> ,�-o„ ,._o.,
<br /> 16'-0" 13'-0" 9'-0" 14'-0" 2'-0"
<br /> 5cale: 1/4" = 1'0"
<br /> 52'-0" 16'-0" 13'-0" 9'-0" 14'-0"
<br /> MAIN FLOOR PLAN �2�-��� �
<br /> z
<br /> 5cal e: 1/4" = 1'0° � : Q
<br /> . '�A��r� G �ii�.(.: .'.J..r'.?i��;l';'ai',
<br /> � ,
<br /> �� Provisi�ns sh�ll ba made for the control a� .� � -� --�� r r ,,.`,�,.p LL
<br /> � � � � water araund buildin ,� �� - �
<br /> 1 gs by: gatt..rs, drain lir:es, i! I.,t� a, d ��:tc; 7
<br /> L
<br /> L— basins or oth�r necessary d�ainage structures and shail b� insi� ��c� O
<br /> I � " � �here st�rm v�✓.t�r �'i4p���1 cannot b� Gbt�ir,�d ti�,itt��ut th��ir u_,: orNOTES: SWX = SHEAR WALL SPECIFICATION SEE SHEET S1
<br /> EXISTING GR�Y�IL SPAGE � ��here er�si�n ca���;ut b� p;event:d by finish grading and pla�?ti �. •20151RCAND2015 WSEC �
<br /> - •ALL BMS.&HDRS.TO BE 4X8 D.F.#2 U.O.N PLUMBING NOTES: � �
<br /> �ry well� 4ha11 nGt b:� install�d in arE:as ��n�h�re the soil is not weff .TYP. NEW PLATE HEIGHT SHALL BE 8'-6" MAIN FLOORAND 7'-6"UPPER FLOOR •FIREBLOCK BETWEEN STUDS. J �
<br /> I I I ( R �Cai11L!i ,� �Ct;�)r �OYpUS. (U.N.O.) •LIMIT SHOWER FLOW AND LAVATORY FAUCETS TO 2.5 G.P.M. �
<br /> 51 •SOLID BLOCKING OVER ALL SUPPORTS. •LIMIT WATER CLOSETS TO 1.6 G.P.F. � Q
<br /> ,,� � •FIRE BLOCKING AT ALL PLUMBING PENETRATIONS. •INSTALL THERMOSTATIC WATER TEMPERATURE LIMITING DEVICE PER W
<br /> ,��,0� ,�,'�� ,�.'�� 2a '�i�aG �'� �"t:�1i b4 prcvid:d tv itis�"B: •TOP WINDOWS TO BE AT T-0"A.F.F. (U.N.O.) MANUFACTURERS RECOMMENDATIONS. � z
<br /> I � I , O•ALL EXTERIOR WALLS TO BE 2 X 6@ 16"O.C.,(U.O.N). •WALLS SHALL BE WATERPROOF TO MIN.70"ABOVE DRAIN INLET. Q
<br /> � � (aj Diversion of water away from buildi f`c=:, •SD-SMOKE DETECTOR •ALL GLAZING INCLUDING WINDOWS WITH�N 70"OF DRAIN INLET TO BE SAFETY a �
<br /> . • •CO=CARBON MONOXIDE ALARM GLASS. ,
<br /> � NEW 30"x30"x12"�oNc. PAD �b) Prevention of standing water and soii 9a�Us"�tiv�: t�et�imLrttal •SMOKE DETECTORS TO BE HOT WIRED W/BATTERY BACKUP SMOKE DETECTORS O
<br /> � � �w/(b)#4 BAR BTM. EA.WAY I t0 St�u:'t'_t;:s and lot use. TO BE AUDIBLE IN ALL BEDROOMS SPECIAL NOTES:
<br /> � •ALL CLOSET/STORAGE SPACE UNDER STAIRS SHOULD BE COVERED W/5/8"TYPE'X' •ANY CHANGES REQUIRE ALL STRUCTURAL LOADS AfVD BEAMS TO BE EXAMINED �
<br /> (c) Th:�t natural drainage channels or basins are nnt blocked c�r G.W.B. IF STRINGER SPACING IS MORE THEN 16'�O.C.THAN TWO LAYERS OF 5/8" AND ALTERED AS REQUIRED PER CHANGE. �
<br /> � il(�d. TYPE'X'ARE REQ'D ON LID. •ALL ANGLED WALLS TO BE 45 DEGREE ANGLE, U.O.N.
<br /> A ,� �"" t t f •HANDRAILS TO BE 34"-38°ABOVE TREAD NOSING AND GUARDRAILS TO BE 36"
<br /> 3 .. , ,he d�sr�s3� c a er rom a lo�
<br /> . . . ..:. .. • . : f . .
<br /> > _ .0 � , ABOVE FINISHED FLOOR U O N.
<br /> _�. � . � , . � � �, Prct�ction � - < <��� p��P'rtY •�tvs
<br /> � � ` ' ' ` (e f ud).,�, ;; „ , TALL FIREPLACE(S)PER MANUFACTURER SPECIFICATIONS.
<br /> •DOOR BETWEEN HOUSE&GARAGE TO BE SOLID WOOD DOOR. (MIN. 1 3/8'THK), OR �ARBON MONOXIDE: O
<br /> 20-MINUTE DIRE RATED DOOR. "���' '�`�'' '� ��"' ' �
<br /> For new construction, an approved carbon monoxide alarm shall be installed outside of each
<br /> • Y2"GYPSUM BOARD ON ALL WALLS AND POSTS. USE 5/8"TYPE'X'GYPSUM WALL separate sleeping area in the immediate vicinity of the bedrooms in dwelling units and on each O
<br /> r� ��713 �i��T� y� I��T POSITIONED �u BOARD ON CEILWG WHEN GARAGE IS BENEATH HABITABLE ROOMS. level of the dwelling and in accordance with the manufacturer's recommendations. Alarms shall "�`� °� � ?�;;�
<br /> INDICATEI7 ON Ai'�'FiOVED SITE PLAiti, • ALL SKYLIGHTS TO BE 2 X 4,2 X 6 OR 4 X 4 WITH LAMINATED SAFETY GLASS,WITH A be listed as complying with UL 2034. �� �% `t �
<br /> I I I I I MIN. .015 INCH POLYVINYL BUTYAL INTER LAYER FOR GLASS PANES 16 SQUARE �
<br /> A NEW SITE PLAN SHALL BE SUL�IVtIT- FEET OR LESS AND IN AN AREA LOCATED SUCH THAT THE HIGHEST POINT OF � � �H �~-,, ,
<br /> TED. NO FURTHER INSP�.CTIii�dS `u'�-�- SCOPE OF WORK:
<br /> GLASS IS NOT MORE THAN 12 FEET ABOVE A WALKING SURFACE OR OTHER
<br /> �_;�, jVjA�E ON THIS PROJECT UNTIL Tt��� ACCESSIBLE AREA. FOR HIGHER OR LARGER SIZES,THE MIN. INTERLAYER •NEW 365 S.F.UPPER FLOORADDITION (NO CHANGE TO FOOTPRINT)
<br /> ( I I F I THICKNESS SHALL BE 0.030 INCH. •REMOVED SOME INTERIOR WALLS TO OPEN UP KITCHEN/GREAT ROOM ���
<br /> kg,VISED SITE PLAN HAS�EEN APPP���ti`v 9liy� ,.
<br /> •ALL INTERIOR BEARING WALL TO BE 2 X 4 STUDS @ 16"O.C., U.O.N. 4i����;� J j���,��
<br /> G Fa� BX THE BCTILDII`dG�PUBL�C W�����- •2 X 8 BLOCK @ 51" FOR THERMOSTAT. ��l�IL�IlaD ��ClTIO�S�r� ��qlJl�eu, _ /, r ° �
<br /> EXISTING SLRB ON GR�DE EXIJTING LOWER LEYEL •VENTALLFANSANDDRYERSTOTHEOUTSIDEASREQ'D.
<br /> t�hiPTS. •USE(2)2 X 6 HF#2 COLUMNS ATALL HEADERS AND USE(2)2 X 6 HF#2 COLUMNS AT "Or TI11S Project To Include: A Benchmark I5 R.equired Or. ��1 t� ��`,.��'� �.:���
<br /> � � � � ALL BEAMS, U.O.N. � �� ,y . � '
<br /> •TEMPEREDSAFETYGLASSTOBEUSEDINALLWINDOWSASFOLLOWS: GLAZED �� �� �,yY?��� ��")j�='r?`r >>� F'a+i�r��nn �T.���E? � � -� .
<br /> � ; ,�vners responsibility to establish � � � _.,J Plumbin S rinkler y �
<br /> Up .fl ,. FRENCH DOORS,WINDOWS AT TUBS OR SHOWERS,WINDOWS WITHIN 5'OF STAIR 9 � p r' „� ,��; " �,
<br /> � propert;� �in�5, LANDINGS&LESS THAN 60°ABOVE STAIRS,AND WINDOWS WITHIN 24"OF DOORS �--� ' � '=��
<br /> VERIFY MIN.b"THIGK „� Mechan���� � ,! ���� +��s�C�`° � '"' '�� ``�� �-?�`�
<br /> •STAIRWAY ILLUMINATION SWITCHING MUST BE PROVIDED AT THE TOP AND BOTTOM U �` `�'�'` '�� ; r �` a
<br /> I S T E M W A L L 8� 1 6"W I D E I OF STAIRWAY UGHTING. � �'., �. ��-_-�. ��`��`"�"""�'�'`��
<br /> x 8"THIGK FOOTING R •LIGHTING EQUIPMENT(MANDATORY). A MINIMUM OF 75 PERCENT OF " �'�`�'�'i' �
<br /> VERIFY OR ADD 36"x36"x10" (TYPIGP�L) 51 PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH- �, �--
<br /> P05T ASV& � txk=NEs -•�r � � �
<br /> FDOTING w/(5)#4 BAR BTM. y .,� Y��u,�. EFFICIENCY LAMPS. 2015 WSEC R404.1 ���..�..�
<br /> I I B��ow I � � a. :�; & CG:. ..., Roof trusses to be designed
<br /> EA.1NAY—� �` 1. HOT WATER HEATER PER 87 NAECA, IF WATER HEATER IS NONRIGID WATER
<br /> ��V OPMENT D��� CONNECTION AND IS OVER 4'IN HEIGHT, IT SHOULD BE ANCHORED OR STRAPPED and drawing prepared by
<br /> a State licens�d structural FILE NUMBER:
<br /> I I I I I I __ __. .
<br /> AS REQ'D FOR SEISMIC. �fl9lnee�
<br /> � � �Z� �`'' " p',� 3. DOOREBE WEEN HOUSE&GARAGE TOO BE SOL DLWOOD DOOR(MIN. 1 3/8"THK),
<br /> SOLID OR HONEYCOMB CORE STEEL(MIN. 1 3/8°THK), OR 20-MINUTE DIRE RATED
<br /> �,�sT� �� ������� 18-073
<br /> � ,.n, , �e-� �'�� ��."-_ -,_
<br /> � � ( � � � ����� � � ������ � � DOOR. _. �:�,",,,� , .
<br /> ADD 5/8"DIA. EXP. BOLT5 @ 4. 18"X 24"CRAWL SPACE ACCESS TO BE EXTERIOR DOOR OR PROVIDED WITH R-30
<br /> INSUL. &SHOULD BE WEATHER-STRIPPED.
<br /> 16"O.G., EMBED 4" INTO I „ , . , 5.22°X 30"ATTIC ACCESS TO BE EXTERIOR DOOR OR PROVIDED WITH R-49 INSUL. & Permit#: 61910-0 DATE:
<br /> (E)GONG. (2}G516x24 '`` �F� ;''-�� � • - � i� SHOULD BE WEATHER-STRIPPED. �
<br /> I I I I I I I I I 5W4 (E)GAR.HDR TO �__ ` � �*�'r�`� �M �^ '� �'��'r Site Address: ll00 ENGLAND AVE 11 /25/2019
<br /> SHEf�RWALL ! 5W4 I `�°�'t �......_.����,Q�r�,_„____..,..,_ Owner: MEHRSADEH ABOOLHASSAN&SHEIDAEI
<br /> (2)G516�4" (2)G51 bx24" � �
<br /> (E)GAR.HDR TO (E)6AR. HDR TO 51 $ �'��� ' `��'' ��`fi d �y MARYAM
<br /> � ���` """'�v �i�%�, r 11N�N$�,� Tenant: [TenName]
<br /> h'' � scc���.g�.� t',a ,r�y n�t ;IHEREQUIPMENTORA
<br /> I 5W4 SHEARWALL I I SHEARWALL I _5 4 5X�5T. I �'`�*' �t��? ° ;: �:.�`8. �,4Y NOT BE LOCATED I►�PP�R�EIvniE. App. Date: l0/30/2019 SCALE:
<br /> 1�V0 SIDE SETBACKS. PRO ANETqN�4 Proposed Use: SFR
<br /> ---- 1/4„ _ � ,�„
<br /> �— �'�.S 8036T5 �'�.S ti�'� ��QUIRE ADDITIONAL PERM��fC �$$�J� Description: ADQN OF 365 SF UPPER FLOOR/REIVIOVE ,
<br /> L - , �THE EVERETT FIRE ' ' INTERIOR WALLS TO OPEN UP
<br /> S r� —9080 —9080 �.S �'TS \ 5W4 �I, I 5W6 I '�R T� !�I�T"I '
<br /> R J H R ,����t:�, �
<br /> 5Y`!b� 5W6 51 51 51 5� � Reviewed By: �`r Date: Z �" SHEET #:
<br /> E X 1 5 T I N G 51 ADD 5/8" DIA. EXP. BOLTS Q E X I S T I N G '�Office Set Job Site Set Fire/Planni��Set
<br /> 16"O.G., EMBED 4"INTO F OUNDATION PLAN
<br /> (E)GONG. �
<br /> 5cal e: 1/4�� _ ��0�� O Brookes Design, Inc.ALL RIGHTS RESERVE, DUPLICATION AND DISTRIBUTION OF THIS PLAN WITHOUT WRITTEN PERMISSION IS PROHIBITED
<br />
|