My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
801 E CASINO RD 2019 Plans 2022-12-07
>
Address Records
>
E CASINO RD
>
801
>
Plans
>
801 E CASINO RD 2019 Plans 2022-12-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2022 2:51:14 PM
Creation date
10/30/2020 9:25:06 AM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
801
Permit
B1910-003
Year
2019
Notes
4 NEW PORTABLES ALONGSIDE EXTG PORTABLES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:� . <br /> . ' � <br /> .:� . <br /> FASTENING SCHEDULE MATERIAL LIST + � <br /> WALLS: FLOOR: ROOF; <br /> PLATE-TO-STUD MIN. OF 3- 0.121" x 3" NAILS 2 x 8 FLOOR JOIST-TO-RIM MIN. OF 4- 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) ROOFING. . . . . . . . . . . . .ARCH. SHINGLES OVER SELF-ADHERED <br /> UNDERLAYMENT APPLIED SHINGLE FASHION <br /> VW TACKBOARD-TO-STUD � iNTERIOR 16 ga x 2" WIDECROWN STAPLES (SENCO P21) � 6" oc TOP & BOTTOM CLASS "A" BOTTOM BOARD-TO-JOIST 16 ga. x 3/8" WIDE CROWN Q 12"oc MAX. -HIGH WIND APPLICATION- <br /> AND GLUED IN FIELD -DRIP EDGE SHALL BE PROVIDED AT EAVES AND <br /> FLOOR DECKING-TO-2x JOIST 0.113" x 2 3/8" RING SHANK � 6"oc EDGE, 12"oc FIELD � <br /> SHEETROCK-TO-STUD @ INTERIOR 0.091 x 2Ya�� NAILS AT 16" oc EDGE AND CONSTRUCTION ADHESIVE IN FIELD. (SENCO GE-24). USE CONSTRUCTION ADHESIVE (AFG01) ON JOISTS RAKE EDGES OF SHINGLE ROOFS (IBC 1507.2.9.3). <br /> SHEATHING. . . . . . . . . . .7/16" APA RATED (24/16) MINIMUM <br /> BOTTOM P�ATE-TO-FLOOR 0.131" x 3" NAILS C�? 8"oc (SENCO KC27 OR EQUAL) <br /> ROOF: FRAMING . . . . . . . . . . . . .2 x 10 DF #2 RAFTERS Cs� 24"oc <br /> SHEATHING-TO-STUD Q SIDEWALL 16 ga. x 1 3/4" STAPLES � 6"oc EDGE, 12"oc FIELD (SENCO N19) RIM-TO-RAFTERS MIN. OF 3- 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) w/ 2" FURRING ON BOTTOM FOR R38 <br /> ALL EDGES SUPPORTED BY FRAMING OR BLOCKING <br /> FURRING-TO-RAFTERS MIN. 4- M20 2 x 3 (MIN.) PLATES EACH SIDE RIDGEBEAM. . . . . . . . . .DOUBLE 1 1/2" x 24" CONTINUOUS LVL 2.0E - ' <br /> SHEATHING-TO-STUD � ENDWALL SEE ENDWALL FASTENING NOTES ON ELEVATIONS. <br /> ROOF RIM-TO-TOP P�ATE 0.131" x 3" NAILS C� 8"oc (SENCO KC27 OR EQUAL) LEDGERS. . . . . . . . . . . . .2 x 4 D.F. TAPER CUT <br /> LAP SIDING TO STUD PER MANUFACTURES SPECIFICATIONS <br /> LEDGER-TO-RIDGEBEAM 0.131" x 3" NAILS C� 3"oc & 3 Q BUTT JOINTS (SENCO KC27 OR EQUAL) RIMS. . . . . . . . . . . . . . .. .2 x 6 CONTINUOUS LVL 2.OE <br /> THREE STUD CORNER CONNECTION 0.131" x 3" NAILS @ 12" (SENCO KC27 OR EQUAL) WITH 2 x 10 DF VENT BLOCKS <br /> RAFTER-TO-RIDGEBEAM 4- 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) <br /> RIDGEBEAM-TO-RIDGEBEAM 4 ROWS � 0.131" x 3" NAILS Q 12"oc INSULATION. . . . . . . . . .R38 CELLULOSE BLOW-IN OVER CLASS "A" <br /> MATERIAL (AIR BARRIER COMPONENT) <br /> AIR BARRIER NOTES: <br /> SHEATHING-TO-ROOF MEMBERS 16 ga x 13/4" STAPLES Cn� 6"oc EDGE, 12"oc FIELD (SENCO N19) CEILING. . . . . . . . . . . . . .SUSPENDED T-BAR (PER IBC 808.1) � <br /> THESE KEY AREAS SHALL BE SEALED BY CAULKING, GASKETS, TAPE OR WEATHER-STRIPPING: NOTE: SHEATHING TO BE INSTALLEO PERPENDICULAR TO THE RAFTERS. <br /> -JOINTS AROUND FENESTRATION (WINDOWS AND DOOR FRAMES): USE APPROPRIATELY SIZED BACKER ROD WITH MINIMUM OFFSET SHEATHING 4 ft. AND BLOCK EDGES OF ANY PIECES LESS THAN 24" ARCHITECTURAL . . . . .12" OVERHANG <br /> 2' LAP AT ENDS. <br /> -JUNCTIONS BETWEEN WALLS AT: MODLINE CONNECTION: NOTE: AL� MODLINES (DEFWED AS THE SPACE BETWEEN ADJOINING MODULES) <br /> SOFFIT. . . . . . . . . . . . . . . .FIBER CEMENT PANEL, PERFORATED FOR <br /> -BUILDING CORNERS: USE CAULKING MUST BE INSULATED AT THE ROOF, FLOOR AND WALLS ON SITE. VENTING AS REQUIRED , <br /> -STRUCTURAL FLOORS: USE SILL SEAL OR CAULKWG ' <br /> -ROOFS (AT RIM): USE SILL SEA� OR CAULKING RIDGEBEAMS 1/2" BOLTS w/ 1Y2" DIA. WASHERS � 6'-0"oc AND 8" FROM EACH END VENTWG. . . . . . . . . . . . .SOFFIT AND RIDGE <br /> -PENETRATIONS OF UTILITY SERVICES THRU THE AIR BARRIER � ROOFS, WALLS, AND FLOORS: USE CAULKING, SPRAY <br /> FOAM, OR AIR BARRIER TAPE. (MINIMUM 2" EDGE DISTANCE) <br /> -BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS: USE BACKER ROD, CAULK, SPRAY FOAM OR AIR BARRIER TAPE. RIM JOISTS 1/2" BOLTS w/ 1Y2" DIA. WASHERS � 4'-0"oc AND 8" FROM EACH END `A/A' ' C <br /> -JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDANTS: USE CAULK OR APPROVED TAPE. (MINIMUM 2" EDGE DISTANCE) '�� , <br /> -RECESSED LIGHTING FIXTURES: USE CAULK OR SPRAY FOAM <br /> SIDING. . . . . . . . . . . . . . .FIBER CEMENT LAP SIDING WITH 8" EXPOSURE <br /> OVER BUILDING WRAP. BUILDING WRAP TO <br /> EXTEND TO BOTTOM OF FLOOR RIM (MIN.) , <br /> MOISTURE . . . . . . . . . . .WRAP LOWER 12" OF BUILDING & CORNERS WITH <br /> C B A PROTECTION MOIST-STOP. WRAP BUILDING w/BUILDING WRAP <br /> 4 6 SHEATHING. . . . . . . . . . .Y2" CDX PLYWOOD (MIN.15/32" RATED SHEATHING) <br /> �-{- � A-4 A-4 FASCIA. . . . . . . . . . . . . .1 x 6 <br /> � I <br /> ��_T-- TRIM. . . . . . . . . . . . . . . . .1 x 4 AT CORNERS, WINDOWS, DOORS AND ' � � <br /> i I 1 x 6 � MODLINE <br /> I ; 12 � 2 NOTE:2"x 2" GALV. FLASHING UNDER CORNERS <br /> LU26 HANGERS AT ALL RAFTERS �2 A-4 A-4 SHIP LOOSE TO BE INSTALLED ON SITE BY <br /> OTHERS <br /> �o OVER DOOR & WINDOW OPENINGS - � � � - <br /> �- WITH 6- 0.131" x 1�/�" NAILS � ` <br /> � INTO LVL ROOF RIM -�.�� �" � — \ FRAMING. . . . . . . . . . . . .2 x 6 D.F. #3 or BETTER STUDS C� 16"oc <br /> RIDGEBEAM BRACING / <br /> � �,.; � �` / SEE DETAIL ;' % , ,� � TOP PLATE. . . . . . . . . .2 x 6 CONTINUOUS LVL 2.OE , <br /> . . \`� 5 ""W---....' •. \ <br /> . <br /> A-4 FLAME SPREAD �� ` ' BOTTOM PLATE. . . . . .2 x 6 D.F. <br /> � IS 25 OR LESS � <br /> \ 124" � INSULATION . . . . . . R-21 FIBERGLASS BATTS <br /> i � <br /> sEA� 6 FT. WIDE WINDOWS � <br /> AT ROOF , INTERIOR FINISH. . . . . .MATERIAL INSTALLED FROM STUDS OUT <br /> R�M/TOP -USE 2- 2x6 D.F. #2 w/ MIN. R10 RIGID FILLER — � EXT. WALLS:LAYER 1: 5/$" TYPE 'X' SHEETROCK (AIR BARRIER) , <br /> PLATE -USE �2� FULL HEIGHT STUDS AND Q LAYER 2: Y2" VINYLWRAP TACKBOARD (FINISH) <br /> (1} TRIM STUD AT EA. SIDE OF WINDOW m � <br /> w ABOVE WALL FINISH: LAYER 1: 5/8" SHEETROCK <br /> � <br /> o AT GABLE ENDS <br /> �ICO BACKER - <br /> � ROD � � <br /> I AROUND � � SKIRTING. . . . . . . . . . .. .SHIP LOOSE <br /> = O <br /> � INTERIOR � � � ONE DRY CUP PERM VAPOR GUTTERS . . . . . . . . . . . .PROViDED AND INSTALLED ON SITE BY OTHERS <br /> SIDE OF <br /> ' WINDOWS � BARRIER ON THE WARM SIDE, <br /> z o � TYPICA� THRU-OUT BUILDING. <br /> � AND DOORS v m FLOOR: <br /> � o <br /> I o � i COVERING. . . . . . . . . . . .ON SITE BY OTHERS <br /> CAULK WALL � I - <br /> �_ � � <br /> CORNERS FROM x= � DECKING. . . . . . . . . . . . .23/3z'� APA RATED T&G - GLUED AND NAILED �� . <br /> TOP TO BOTTOM � (AIR BARRIER COMPONENT) � � <br /> AT INTERIOR i <br /> � FRAMING. . . . . . . . . . . . .2 x 8 DF #2 JOISTS C� 16"oc <br /> SEAL I A-4 RIMS. . . . . . . . . . . . . . . . .2 x 8 CONTINUOUS LVL 2.OE <br /> AT FLOOR � 4 7 NOTE:12" HIGH MOISTURE BARRIER INSTAL�ED ON � <br /> RIM/BOTTOM /� � A-4 A-4 � � PERIMETER (OVER GYPSUM) AT RIMS AND END � <br /> PLATE / � ` JOISTS <br /> , <br /> � i 1 � i � ' <br /> I JOIST HANGERS. . . . . .AT ALL RIMS <br /> \ � INSULATION. . . . . . . . . .R-30 UNFACED FIBERGLASS BATT FIBERGLASS <br /> � \� / � �� �� (USE TWO LAYERS OF R-15) <br /> � � <br /> MIDSPAN MIDSPAN <br /> SUPPORT �" SPACE SUPPORT BOTTOM COVER . . . . . .CLASS A <br /> REQUIRED REQUIRED � ' <br /> 6'-11" 6'—�1" 6'—��" 6'-1�" 09/27/2017 <br /> 13'-10" 13'-10" OG o wA���'l�, <br /> � �w �'c��' ° <br /> C r :L <br /> �ITY �� �'VEF�E��� �t , <br /> N — A A �������aS��� ��� � �.� �. � � <br /> S E CT I O � :� _ ..__ . ����� . �o��s���s°°�R����ww <br /> SI�NAL �� <br /> 1/2" = 1'-0" <br /> 9-7-17 DELETE RIGID FOAM ON INTERIOR OF EXTERIOR WALLS LDG COPYRIGHT 2017, BLAZER INDUSTRIES, INC. � MODULAR Approved for Const: Job No: 19031 � � LL <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY Classroom for. <br /> OF BLAZER INDUSTRIES, INC.AND SHALL �� 2$ X 32 KC DA - Eve rett S D File Copy: <br /> NOT BE REPRODUCED, USED,OR DISCLOSED �� INDUSTRIES, wC. � � <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE Drawn By: LDG <br /> �� www.biazerind.com WA. GOLD PaCIfiC MObil2 17 BLMP-04 A9 W/4 <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� P.O.BOX 489 ■ Aumsvi��e,OR 97325-0489 issue Date: 9-7-17 , <br /> � <br /> . , <br /> � <br /> � • . <br />
The URL can be used to link to this page
Your browser does not support the video tag.