I , ; . <br /> _ . _____ _ _ . _ <br /> LIGHTING FIXTURE SCHEDULE 35/8�� METALSTUDTRACKW/ CEILING LEGEND: <br /> FASTENERSINTO EACH <br /> � LAMP ATTACH TRACK TO ROOF DECK W/ 10 x 1 1/2° SCREWS AT 24" O.C. SIDE OF STUD <br /> TYPE MANUFACTURER PRODUCT NUMBER VOLT NO. COLOR DRIVER WATTS DESCRIPTION STAGGER FASTENERS SO THEY ARE WITHIN 1/2" OF 2'X2'ACOUSTICAL SUSPENDED CEILING. <br /> EDGE OF TRACK AND WITHIN 1/2" OF EACH STUD. 3 5/8" MEfAL STUDS @ 24" O.C. SEE MATERIAL SCHEDULE FOR TYPE, AND <br /> L1 NORA NHIC-5LMRAT/NLCBC-651-27-DW-LE4 120 LED 2700K ELV �3 6" RECESSED DOWNLIGHT. 750 LUMEN OUTPUT. 2/A2.31 FOR CEILING DETAILS. <br /> DIFFUSED/WHITE FINISH. ELV DIMMING (E) ROOF STRUCTURE ABOVE <br /> SCOTT I EDWARDS ARCHITECTURE LLP <br /> 45"SUSPENDE DLINEAR W/ROUNDED LENS. 0-10V DIMMING. <br /> L2 BARTCO BLT205-45-30-DIM-8-RCM48-WH UNV LED 3000K 0-10V 31 48"CABLE MOUNT LENGTH. WHITE (SEMI-GLOSS) FINISH. NON-RATED GYP. BD. SOFFIT R <br /> ' INCLUDE OCCUPANCY SENSORS IN FIXTURE. � � NON-RATED ONE LAYER GYP. BD. 2525 E. Burnside St., Portland, OR 97214 <br /> � SUSPENDED CEILING phone:(503) 226-3617 www.seallp.com <br /> SEE 2/A2.31 FOR CEILING DETAILS. <br /> 4' LINEAR PENDANT. ELECTRONIC T8, INSTANT START '' <br /> L3 COLUMBIA AWN-4-2-32-E-U UNV 1 3000K N/A 25 BALLAST. 8"WIDE LOW PROFILE WRAPAROUND. RECESSED LIGHT FIXTURE-MAINTAIN 1 <br /> 0 HOUR RATING AT FLOOR/ROOF-CEILING <br /> PENETRATION WHERE OCCURS � <br /> 6" CYLINDER PENDANT. 2000 LUMEN OUTPUT. REFLECTOR �asa4 <br /> L4 NORA NYLS-6-C-2-1-30-DW-W-1-AC 120 LED 3000K 0-10V 25 TRIM. DIFFUSED/WHITE TRIM COLOR. 0-10V DIMMING CAPABLE. SUSPENDED FOH LIGHT FIXTURE <br /> � � 8'-6"AFF, UNO RFGES'�REQ <br /> I ARL Cfi, <br /> _ y__ <br /> (2)4' LINEAR TRACK LENGTHS LINKED TOGETHER, WHITE FINISH, 2.5A CURRENT LIMITER, SUSPENDED BOH LIGHT FIXTURE <br /> NT-302-W ELV DIMMING CAPABLE. BOTTOM OF TRACK @ 10'-8"AFF. THE TftACK FIXTURE WILL � � 9'-0"AFF, UNO <br /> L5 j NORA W/(2) NORA NTH-124-W 120 N/A 2700K N/A 300 MOUNT BELOW THAT, AND BOTTOM OF TRACK FIXTURE WILL BE AT APPROXIMATELY �t �ROl1 G�mm <br /> LAMPS PER 4'TRACK 10'-2", WHICH COORDINATES WITH THE TOP OF THE CYLINDER PENDANTS. - + . --._ 2-#10 SCREWS AT EACH PENDANT LIGHT FIXTURE ��A�E QF WASNINGTON <br /> . VERTICAL&HORIZ. STUD � 9'-0"AFF, UNO <br /> 25" LINEAR VANITY. 1375 LUMEN OUTPUT. BRUSHED INTERSECTION <br /> L6 MODERN FORMS y�g_Wg1625-AL UNV LED 3500K N/A 20 ALUMINUM FINISH. DIMMING CAPABLE. MOUNTED 4"ABOVE TRACK LIGHT <br /> MIRROR ON CENTER. <br /> 10'-8"AFF, UNO; CONFIRM HT W/OWNER <br /> ANGLE 2"x2"x33 W/ SCREW PRIOR TO INSTALLATION , <br /> Digitaliy signed by Peter Grimm <br /> CEILING TYPE: -.-_ - -- - — INTO EACH STUD g'_0"AFF � WALL MOUNTED LIGHT FIXTURE Date:2020.02.27 09:54:53-08'00' <br /> HT PER INTERIOR ELEVATIONS <br /> LAY-IN ACOUSTIC PANEL CEILING &CLOUDS OR DIREC7(SCREV�ATTACHED 5/8" B.O. GYP. BD. CEILING <br /> GYPSUM WALL BOARD. <br /> 2„ M,qX 2,� MAX <br /> � CEILING MOUNTED SPEAKER <br /> LOAD CRITERIA: <br /> VERTICAL: 4 PSF. <br /> DUTY CLASSIFICATION: HEAVY-DUTY PER ASTM G W B <br /> � SECURITY CAMERA <br /> C-635-00. <br /> . CROSS RUNNER DEFLECTION: L/360 MAX. SO F F I T D ETA <br /> GRID LIMITATIONS: 3 EXIT SIGNS- <br /> 3"=1'-0" � FLUORESCENT LIGHT FIXTURE <br /> MAXIMUM GRID SPACING: 4'X4'. <br /> SURFACE MOUNT <br /> INTERSTITIAL SPACE HEIGHT: 15' MAXIMUM. <br /> INTERIOR NON-BEARING PARTITIONS: INDEPENDENTLY SUPPORTED AND • <br /> BRACED-SEE DETAILS. /, . � WIRELESS ACCESS POINT <br /> REFERENCE SOURCES PER HIERARCHY: �� <br /> 2015 IBC W/WA AMENDMENTS PROPRIETARY SYSTEM FIE�D FRAMED SYSTEM — - <br /> ARMSTRONG SEISMIC RESTRAINT TECHNICAL GUIDELINES <br /> GENERAL NOTES: <br /> A. SYSTEM COMPONENTS: <br /> PRE-ENGINEERED SUSPENDED ACOUSTIC TILE-ARMSTRONG PRELUDE OR <br /> EQUAL SUSPENDED DRYWALL-ARMSTRONG DRYWALL 1. CEILING FIXTURES ARE SHOWN FOR REFERENCE ONLY, F ZOOM ca re� <br /> GRID SYSTEM OR EQUAL. COORDINATION WITH CEILING FINISH SYSTEM SEE <br /> MECHANICAL, ELECTRICAL&SPRINKLER BIDDER-DESIGNED <br /> . DRAWINGS <br /> MAIN RUNNERS 12" COLD FORMED STEEL'C' CHANNEL, OR PRORIETARY'T' <br /> SECTION MEETING DUTY RATING SPECIFIED ABOVE, @ 48" 2. SPOT ELEVATIONS ARE FROM TOP OF SLAB TO SURFA <br /> FINISH OF CEILING &ARE ROUNDED TO THE NEAREST iNCH (TYP) <br /> O/C. COMPRESSION STRUT @ 3. CEILING FIXTURES TO BE CENTERED OR EQUALLY SPACED & EVERETT <br /> CROSS RUNNERS s"X 2a" X 25 GA. CARBON SHEET STEEL HAT CHANNELS, 12'-0"OC MAX EA WAY ALIGNED IN ROOM/SPACE UNO ' <br /> OR PROPRIETARY'T'SECTION MEETING DUTY RATING <br /> 4. CEILING HEIGHT TO BE AT UNDERSIDE OF ROOF STRU 221 EVERETT MALL WAY <br /> SPECIFIED ABOVE @ 2' O/C. OR FLOOR ABOVE UNO <br /> SUSPENSION WIRE #12 SWG GALVANIZED WIRE. CROSS RUNNERS 5. PROVIDE RATED LIGHT FIXTURES AT ALL FIRE RESISTIVE SUITE M-3 <br /> TIE W1RE #18 SWG GALVANIZED WIRE- DOUBLE STRAND. ASSEMBLY PENETRATIONS. PROVIDE NON-RATED LIGHT <br /> B• �#12 WIRE BRACING @ 45° EVERETT, WA 98 <br /> FIXTURES ALL OTHER LOCATIONS <br /> ANCHORS TENSION LOAD CAPACITY: 200#MIN. EA. 6. SEE BIDDER-DESIGNED MECHANICAL, ELECTRICAL, AND <br /> � &ALIGNED W/EA RUNNER <br /> WOOD: a"X3"SCREW EYES. <br /> STEEL DECK: CMI DC1 OR DC 2a' METAL DECK SCREW (4 DIRECTIONS) TECHNOLOGY DRAWINGS FOR ALL OTHER EQUIPMEN <br /> EYES. 7. PAINT MECHANICAL DIFFUSERS IN GYPSUM BOARD <br /> CONCRETE: EMBEDS OR HILTI X-U FASTENERS AT � MAIN RUNNERS CEILINGS AND WALLS TO MATCH ADJACENT CEILING <br /> . 8. SEE STRUCTURAL SHEETS FOR FRAMING INFORMATION & <br /> HANGER WIRES AND KWIK-HUS EZ AT <br /> SPLAY WIRES. REQUIREMENTS <br /> B. LATERAL BRACING-CEILINGS OVER 144 SF: o $�, Mpx 48"O/C TYP g" MAX CEILING JOIST SIZING CHART � <br /> PROVIDE 4 W�RES OF MINIMUM NO. 12 GAUGE W 4 DIRECTIONS 90 - <br /> APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE FOR GYP. BOARD CEILIN <br /> CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT TO <br /> EXCEED 45° FROM THE PLANE OF THE CEILING. THESE LATERAL 1" MIN. CLR. TO ALL STABI IZER CLOSET 2 CLOSET 1 STUD PROFILE DEFLECTION SPACING MAX SPAN <br /> SUPPORT POINTS SHALL BE PLACED 12'O.C. IN EACH DIRECTION WITH R NNERS PENETRATIONS 110 109 UCR 362S162-33 L/240 16"OC 10'-0" <br /> THE FIRST POINT WITHIN 4' FROM EACH WALL. 4„ (E) CEILING (E) CEILING 105 600S162-33 L/240 16"OC 12'-6" <br /> COMPRESSION STRUT: LOCATE AT AND CENTER ON ALL LATERAL \ 10'-2 1/2"A.F.F. 10'-2 1/2"A.F.F. g'-6"A.F.F. 600S162-43 Ll240 16" OC 16'-0" <br /> SPLAY WIRE LOCATIONS NOTED ABOVE. ATTACHED RIGIDLY FROM B _ _ - <br /> MAIN RUNNER TO STRUCTURE ABOVE. ' <br /> • z'Q1 EMT CONDUIT 5'-10" MAX LENGTH ' !! <br /> a"OEMT CONDUIT 7'-8" MAX LENGTH � , ' , � <br /> 1"OEMT CONDUIT 9'-9" MAX LENGTH PERIMETER L@ CEILING ' W � O , <br /> 1 1 s"X20GA METAL STUD 12'-0" MAX LENGTH STARTER WALL pENETRATION PERIMETER L@ �' �4 o L3 EQ o L3 EG2 <br /> � ) 2" FIXED END . • w <br /> (2) BACK TO BACK 1 s"X20GA METAL STUD 15'-0" MAX LENGTH OPPOSITE WALL , o o L2 L2 <br /> DFLOATING END , L3 ' <br /> C. PERIMETER CLOSURE- LAY-IN ACOUSTIC PANEL CEILINGS OVER 144 SF: �+ • ' ' O _ <br /> EQ EQ L4 EQ EQ o <br /> PERIMETER SUPPORT ANGLE SHALL BE ATTACHED TO WALL FRAMING WITH � <br /> i N �I <br /> MINIMUM#6 SCREW @24" O/C MAX, AND ANGLE SHALL HAVE A MINIMUM 2" ' WORKROOM • L5 L5 <br /> HORIZONTAL LEG. ONE END OF GRID SHALL BE ATTACHED TO THE CLOSURE ' ', ')OH <br /> ANGLE AT EACH OF TWO ADJACENT WALLS W/RIVETS. THE OPPOSITE END (4)#12 DIRECTL ' ' (E) CEILING o L3 '�, <br /> . OF THE GRID IN EACH HORIZONTAL DIRECTION WILL REST FREE UPON THE ON FIXTURES ' ' 10'-2 1/2"A.F.F. � o L3 �w U, ' <br /> SUPPORT ANGLE W/3/4" CLEARANCE BETWEEN GRID END AND WALL. GRID HANGER <br /> w <br /> PROVIDE 1" CLEAR ON ALL SIDES OF PENETRATIONS. <br /> 0 0 .- � PHARMACY r-o° 2�-0° � <br /> ' L3 EQ EQ W �7 � '' . <br /> D. STABILIZER BARS- LAY-IN ACOUSTIC PANEL CEILINGS OVER 144 SF. 56#+ �� 0 0 (E) CEILING . � <br /> 3 � � � L1 c1 L1 10'-2 1/2"A.F.F. L4 L4 <br /> GRID MEMBERS PERPENDICULAR TO THE WALL AT THE UNATTACHED SIDES GRID HANGE 2 3 w , <br /> 2, �,� __ <br /> OF THE GRID SHALL BE TIED TOGETHER(STABILIZED) AT A POINT NOT MORE ' <br /> , _ 1'-9" 3 1'-9" HALL 3 a <br /> THAT 8" FROM AND PARALLEL TO THE WALL, TO PRVENT THEIR SPREADING <br /> � EQ 2.3 EQ ', � 1 2 2.3 w <br /> E. VERTICAL SUPPORT: , E� E4 a HALL O O 09'-0"A.F.F.� <br /> �— <br /> MAIN RUNNERS SHALL BE HUNG USWG SPECIFIED WIRE AT MINIMUM 4'O/C � W � EQ EQ 2 3 � 1 2 � B.O.B LKHEAD 3 C� 1 ' SO O , � <br /> AND; CROSS RUNNERS AND MAIN RUNNERS SHALL BE SUPPORTED WITH , L4 � (E) CEILING �, 2�3 W L4 L4 , <br /> . „ �! ' 0 W 10'-2 1/2"A.F.F. 9-� EQ EQ <br /> ADDITIONAL HANGER WIRES WITHIN 8 OF ANY DISCONTINUOUS END, , <br /> INCLUDING PERIMETER SUPPORT ANGLES. ! �1 ' . r -- - - � W�ELCOME <br /> HANGERS SHALL NOT PRESS AGAINST PIPES OR DUCTS. HANGERS MORE �- - -- � 101 <br /> � H OZL 2'-6" 2�_6�� _ � I W (E) CEILING , <br /> THAN 1:6 OUT OF PLUMB SHALL HAVE COUNTERSLOPING WIRE D. � I, C° i i 10'-2 1/2 A.F.F. <br /> COUNTERSLOPING HANGERS SHALL BE INSTALLED WITH A MINIMUM 45 9'-0"A.F.F. � , N DCaWll1 <br /> DEGREE ANGLE FROM HORIZONTAL PROVIDE A TRAPEZE MADE OF MAIN - � 0 I I � ' g� <br /> RUNNER STOCK WHERE OBSTRUCTIONS TO STRUCTURE REQUIRE DIRECT ', • �2 • �2 • �2 • �2 � �1 � � �4 � <br /> ATTACHEMENT. (2)#12 SAFETY ' Z � � ' <br /> HANGER WIRES SHALL ATTACH TO RUNNERS AND SUPPORT ABOVE WITH A HANGERS a ' <br /> HANGER ', �1'-9��,� w 1'-9" N ( I <br /> MINIMUM OF THREE FULL TURNS WITHIN A 3 INCH LENGTH. � REFLECTED CEILING PLAN <br /> -� � � w <br /> F. FIXTURE SUPPORT: � I I <br /> � . . <br /> LIGHTING FIXTURES AND AIR DIFFUSERS SHALL BE SUPPORTED DIRECTLY BY ', ', 0 L1 � 0 I I <br /> • 12 GAGE WIRES TO THE STRUCTURE ABOVE BY A MINIMUM OF 4 HANGERS ONE 20#- 56# , _ L1 � � <br /> d L L5 <br /> AT EACH CORNER. <br /> -- GRID HANGE W � L J � <br /> L6 N N <br /> EXCEPTION: FIXTURES NOT OVER 56 POUNDS IN WEIGHT BUT MORE THAN 20 ___ <br /> ', _ Job No: <br /> POUNDS IN WEIGHT, MAY BE SUPPORTED AND ATTACHED DIRECTLY TO THE . __ __ <br /> CEILING SYSTEM RUNNERS W/IN 3"OF GRID INTERSECTIONS BY A POSITIVE <br /> Date: 02/24/2020 <br /> ATTACHMENT SUCH AS SCREWS OR BOLTS.AND, SHALL HAVE (2)#12 GAGE <br /> HANGERS DIRECTLY FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. EQ (4)2' PANELS EQ EQ _ EQ <br /> THESE MAY BE SLACK. TEST _ <br /> FIXTURES WHICH WEIGH NOT MORE THAN 20 POUNDS AND WHICH RECEIVE NO <br /> RESTROOM UCR UCR NOOK Drawn By: <br /> TRIBUTARY LOADING FROM DUCT WORK MAY BE POSITIVELY ATTACHED TO 111 105 104 103 Checked By: - <br /> AND SUPPORTED BY THE CEILING RUNNERS ALONE. 9'-0"A.F.F. 9'-6"A.F.F. 9'-6"A.F.F. 9'-0"A.F.F. <br /> F . Sheet No: <br /> � SUSPENDED CEILING GRID SYSTEM - GENERAL REQ. REFLECTED CEILING PLAN <br /> 2 NTS � 1/4"=1'-0" • <br /> NORTH ■ <br />