Laserfiche WebLink
Exterior poor Schedule <br /> NOMINAL SIZE DOOR FRAME DETAILS � ' <br /> __- - , T .. -- - ------- - -- ___ ___ ---- - <br /> ID ROOM TYPE WIDTH HEIGHT THICKNESS MATERIAL ;FINISH MATERIAL FINISH HEAD JAMB THRESHOLD U-VALUE HARDWARE COMMENTS <br /> 100 (N)SITTING AREA EXIST. 3'0" 7'0" 1 3/4" ALUMINUM +ANOD. BRONZE ALUMINUM ANOD.BRONZE - - - EXIST. EXIST. PROVIDE PANIC HARDWARE <br /> - __ _--. __ -- - -------- - --- --- _ -- --..-- __- . __ _ _ ---- _ _ <br /> 105 (N) MEETING EXIST. 3'0" 7'0" 1 3l4" ALUMINUM ANOD. BRONZE ALUMINUM ANOD.BRONZE - - - EXIST. EXIST. PROVIDE PANIC HARDWARE <br /> - ----- <br /> 106 (E)STOR.&ELECTRICAL EXIST. 3'0" 7'0" 1 3/4" ALUMINUM ANOD. BRONZE ALUMINUM ANOD.BRONZE - - - EXIST. EXIST. TO REMAIN LOCKED, REMOVE <br /> HARDWARE FROM EXTERIOR <br /> --------- -- - _. _- - _ _ _ - <br /> 108 -1 (E)MULTI-PURPOSE ROOM EXIST. 3'0" 7'0" 1 3/4" ALUMINUM ANOD. BRONZE ALUMINUM ANOD.BRONZE - - - EXIST. EXIST. PROVIDE PANIC HARDWARE <br /> _- -- --- <br /> 108 -2 (E)MULTI-PURPOSE ROOM EXIST. 3'0" 7'0" 1 3/4" ALUMINUM ANOD.BRONZE ALUMINUM ANOD.BRONZE - - - EXIST. EXIST. PROVIDE PANIC HARDWARE � <br /> --- - --- -- -- _ _- - -_- -- -- ---- ---._--- -- - - -- -- <br /> __.. <br /> 114 (E)CLASSROOM EXIST. 3'0" 7'0" 1 3/4" ALUMINUM ANOD.BRONZE ALUMINUM ANOD.BRONZE - - - EXIST. EXIST. <br /> NEW DOOR TO HAVE MAX. <br /> 115 (E)CLASSROOM NEW 3'0" 7'0" 1 314" ALUMINUM ANOD. BRONZE ALUMINUM ANOD. BRONZE - - - 0.60 NEW U-VALUE OF 0.60&SAFETY � <br /> - --- .__------------- ._--------- - GLAZING Z <br /> �__-- --- ------ -- _ ------ -_ ---__-- -- - ---- -- <br /> - __- - - - - ------ - __ - -_ _ _ _ <br /> 116_ (N)CLASSROOM EXIST. ' 3'0" 7'0" 1 3/4 _',_ALUMINUM ANOD. BRONZE IALUMINUM ANOD.BRONZE �_ - - - EXIST. EXIST <br /> - ------ ' _____ ---- - -_ __ ._ -- - --�- ----_ _-- __ ___ <br /> Interior poor Schedule � <br /> NOMINAL SIZE DOOR FRAME DETAILS � <br /> ---- - --- - -- --- -__--- - _ _ _ _ __ _ --- ! <br /> ID ROOM TYPE WIDTH HEIGHT THICKNESS MATERIAL FINISH MATERIAL �FINISH HEAD JAMB THRESHOLD HARDWARE I RATING COMMENTS <br /> 104 a (N)OFFICE C 3'0" 6'8" 1 3/4" WOOD CLEAR H.M. PAINT 7-A2.4 7-A2.4 1 A2.4 -- ; <br /> ----- -- ---. _----- __ __ --- ____- -- - -----__ _ _ <br /> _- --�. - _ <br /> 105 a (N) MEETING ROOM C 3'0" 6'8" 1 3/4" WOOD CLEAR H.M. PAINT 7-A2.4 7-A2.4 1 A2.4 __ PROVIDE PANIC HARDwARE,DOOR <br /> SHALL NOT BE LOCKABLE <br /> - - --------- ------ ---- - . ___ _- -__-- -- --___--- ------ -----___- -- _--------- <br /> 106 a {R)STOR. &ELECTR. E 5'0" 7'11" 1 314" WOOD CLEAR H.M PAINT 7-A2.4 7-A2.4 1 A2.4 -- �SLIDING BARN DOOR � . <br /> PROVIDE PANIC HARDWARE IN THE <br /> 108 a (E)MULTI-PURPOSE RM B 7'0" 7'0" 1 3/4" WOOD CLEAR H.M. PAINT 7-A2.4 7-A2.4 1 A2.4 -- DIRECTION OF EGRESS TRAVEL, <br /> DOOR SHALL NOT BE LOCKABLE <br /> __. -_ ------- -- -- --- <br /> -- --- __- <br /> 108 b (E)MULTI-PURPOSE RM EXIST. 3'0" 6'8" 1 3/4" EXISTING PAINT � <br /> (E)H.M PAINT -- -- 1 A2.4 (E) . <br /> - - - - - - -- - - - <br /> 108 c (E)MULTI-PURPOSE RM EXIST. 3'0" 6'8" 1 3/4" EXISTING PAINT (E)H.M PAINT 7-A2.4 7-A2.4 1 A2.4 (E) <br /> 110 a (N)STORAGE A 3'0" 6'8" 1 3/4" WOOD PAINT H.M. PAINT 7-A2.4 7-A2.4 1 A2.4 - <br /> ------_.-_------------- ---------- - -- - ---- <br /> - - -- - - ----- <br /> 111 a (E)TOILET EXIST. 3'0" 6'8" 1 3/4" EXISITING PAINT (E)H.M PAINT -- -- 1 A2.4 (E) <br /> ------. _-- ------ - ---- -- <br /> 112 a (E)TOILET EXIST. 3'0" 6'8" 1 3/4" EXISITING PAINT (E)H.M PAINT -- -- 1 A2.4 (E) <br /> DOOR SHALL BE LOCKABLE FROM <br /> 113 a (N)TOILET A 3'0" 6'8" 1 3/4" WOOD PAINT H.M PAINT -- i -- 1 A2.4 -- THE WSIDE&CAPABLE OF BEWG <br /> _ ' UNLOCKED FROM THE INGRESS SIDE <br /> -- -- -- - --- ----- ___--- --- _-------- - ___---- --- <br /> �_ -- ---- __ i __ _--- ----------. - . __ <br /> ---- � <br /> --- <br /> 114 a (E)CLASSROOM D 3'0" 6'8" 1 3/4" WOOD PAINT (E)H.M PAINT 7-A2.4 7-A2.4 1 A2.4 (E) <br /> - ---- -- ---- ----- <br /> 115 a (E)CLASSROOM D 3'0" 6'8" 1 3/4" WOOD PAINT <br /> (E)H.M PAINT 7-A2.4 7-A2.4 1 A2.4 (E) <br /> - --- ---- ------ -- - <br /> -- - ----- ----- --- <br /> _ ____ _____--___. _____-- <br /> 115 b (E)CLASSROOM EXIST. 3'0" 6'8" 1 3/4" EXISITING PAINT (E)H.M PAINT 7-A2.4 7-A2.4 1 A2.4 (E) <br /> ------ ------------ - - - --- <br /> . <br /> 116 a (N)CLASSROOM D 3'0" 6'8" 1 3l4" WOOD PAINT H.M PAINT 7-A2.4 7-A2.4 1 A2.4 -- <br /> --� <br /> �■ <br /> �� <br /> EQ. EQ. GENERAL DOOR NOTES <br /> �-- ----� ----� environmental <br /> i � , '�� <br /> ________ 1. FIELD VERIFY ALL SIZES PRIOR TO ODERING. WORKS <br /> , , � �'� ;' � <br /> � � � � � � Community Design Center <br /> ' � ' 2. ALL LATCHES, LOCKSETS&DOOR HANDLES TO COMPLY WITH ICC/ANSI <br /> ,� ,� , ,' <br /> , , `� , , <br /> �' ' �� �' �' A117.1-2015 SEC 404.2.6 LEVER HANDLES. <br /> � �' � � , S.G. <br /> , � � � � <br /> � -- 402 15th Avenue East <br /> --- � <br /> � � � Seattle, Washington 98112 <br /> � � � � � <br /> V �� ,� �� A phone: 206.329.8300 ' <br /> `� `� `� `� fax: 206.329.5494 � <br /> ��� s.�.��, ,�'s.�. s.�.�� ��, ABBREVIATIONS <br /> , -- ---._�,- � <br /> , , , � � <br /> ` ' � H.M. HOLLOW METAL <br /> A B C D E <br /> CLR TRANSPARENT FINISH <br /> SOLID CORE BIRCH PAIR OF SOLID CORE SOLID CORE BIRCH SOLfD CORE BIRCH SOLID-CORE PAINTED Casino Road <br /> WOOD FLUSH DOOR BIRCH WOOD FULL WOOD FULL LITE WOOD FULL LITE SLIDING DOOR WITH <br /> LITE DOORS DOORS DOORS BARN-DOOR HARDWARE C om m u n ity H u b <br /> Tenant Improvement <br /> 14 E Casino Road <br /> 8 8 �s�-o°�E� �s�-o°(E}--- ---- __ ----- - - -- -�$'-o°�E7 Evere , A 98208 • <br /> 18'-0"(E) ---- . <br /> A2.4 A2.4 _ _ _ _ _ __ --_ -- -__ -- _-__ __ ---- - <br /> - --- -� <br /> , <br /> 5'4" _3'-0"(E) EQ EQ EXISTING EXISTING ALUMINUM EXISTING EXISTING ALUMINUM <br /> - - - STOREFRONT STOREFRONT STOREFRONT STOREFRONT <br /> WOOD TRIM TO � NEW TRANSOM <br /> MATCH EXISTING , __ __ GLAZING ABOVE NEW �� REMOVE EXISTING DOOR GLAZING TO REMAIN FRAMES TO REMAIN GLAZING TO REMAIN FRAMES TO REMAIN <br /> INTERIOR TRIM�II / / a DOOR.SEE ENERGY I <br /> O � _ NOTES ON T1.2 � ���� � . ' <br /> W-01 //v , � <br /> � ;- � EXISTING '%�� i! // �� ' ��� RELOCATED OR NEW EXISTWG ALUMINUM �� � � - '� � ��������� <br /> $ _ _ � FRAME MEMBER AT I � ����� �' <br /> STOREFRONT � NEW DOOR HEAD STOREFRONT � �\ <br /> A2.4 ' GLAZING ���'� � ��� FRAMES ' � - <br /> EQ EQ � �� // �%� � j // ii' :/ /� //� ��� %/� // // �� <br /> � _ _ I FU STW�ALUMINUM � � <br /> REMOVE EXISTING �� '/ I � ��-�"G������������ <br /> I i- EXISTING ALUMINUM / � EXISTWG � `� GLAZED DOOR TO <br /> � �� `� STOREFRONT �� � STOREFRONT � �,, y � <br /> FRAMES <br /> � PANELS&FRAME STO GLAZOING i // REMAIN � » ,��t� <br /> j; ;; �I <br /> -- ----�- MEMBERS "' "; <br /> ' -------------�_--- , . <br /> � EXISTING OPAQUE � � � �� � <br /> �'� STOREFRONT i NEW 3'WIDE GLAZED DOOR � // ( /i / � // // �� <br /> PANELS � PER SCHEDULE,TO MATCH ' <br /> �" „� ,; � � ��,�E)100 <br /> � 115 EXISTING DOORS,WITH <br /> „ <br /> � ,,, , <br /> ,,, <br /> , -- <br /> � -- -- - - .„ <br /> - SAFETY GLAZING PER IBC . .- -- - . <br /> PROVIDE NEW SAFETY GLAZING SECTIONS 2406.4.1&2406.4.2 RELOCATED OR NEW FRAME APPLY NEW OPAQUE FILM TO INSIDE <br /> WITH MAXIMUM U-VALUE OF 0.38& AND MAX.U-VALUE OF 0.60 DOOR SCHEDULE <br /> � MEMBERS TO MATCH ADJACENT FACE OF(E)STOREFRONT GLAZING APPLY NEW OPAQUE FILM TO APPLY NEW OPAQUE FILM TO --- - ----- --- ----- ---- <br /> MAX SHGC OF 0.40 PER WSEC STOREFRONT CONFIGURATION PANELS AT SHADED PANELS INSIDE FACE OF(E)STOREFRONT INSIDE FACE OF(E)STOREFRONT <br /> 2 TABLE C402.4 AT LOCATION 2 GLAZING PANELS AT SHADED GLAZING PANELS AT SHADED STOREFRONT ELEVATIONS <br /> ADJACENT TO NEW DOOR <br /> PANELS PANELS <br /> 5 Re-Lite Elevation 4 Storefront at Classroom 115 (W) 3 Storefront at Computer Lab 103 (N) 2 Storefront at Computer Lab 103 (E) 1 Storefront at Sittin Area 100 S <br /> A2.2 Scale: 1/4" = 1'-0" A2.2 Scale: 1/4" = 1'-0" A2.2 Scale: 1/4" = 1'-0" A2.2 Scale: 1/4" = 1'-0" A2.2 Scale: 1/4" = 1'-0" <br /> Date <br /> 1 March 2019 <br /> Permit Set <br /> Revisions <br /> 1 2019-05-15 Permit Corrections <br /> 2 2019-06-10 Permit Corrections <br /> Drawn by: � <br /> mbk <br /> Checked by (P.M.): <br /> Checked by {Q.C.): <br /> Project No. <br /> 18024 <br /> a � se�� r-� � �� A2 2 <br /> 4.r S '..� �..x g� �'��.r�+�:�. <br /> €�����F���� !��� �'F�' . <br /> ■■ <br /> ■■ <br /> Y:12018xxproj118024A Caaino Rd Community Hub\07 Drawings118024 Casino Rtl VW2019.vwx <br />