Laserfiche WebLink
Permit# <br /> C1912-OQ2 <br /> Site Address: 26 8LSTSTSW <br /> Owner: NGUYEN RICHARD DUC PHUOC <br /> TenantPropose: SFR(TenNamej <br /> GENERAL NOTES PROJECT INFORMATION ENERGY CODE NOTES LEGEND App.°atde-Use: w13nols <br /> OWNER NAME: NGUYEN RICHARD DUC PHUOC <br /> REQUIREMENTS OF THE 2015 WASHINGTON STATE ENERGY CODE SHALL BE Description: MAIN FLOORADDmoN I100SF <br /> ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND ORDINANCES FOLLOWED. SYMBOL DESCRIPTION Reviewed By: <br /> INCLUDING THE 2015 INTERNATIONAL RESIDENTIAL CODE AS WELL AS THE 2015 SITE ADDRESS: 26 81ST ST SW , EVERETT, WA 98203 °ate: �rf <br /> WASHINGTON STATE ENERGY CODE AS WELL AS THE CURRENT CITY OF PRESCRIPTIVE ENERGY CODE COMPLIANCE , Office Set .lob Site set <br /> EVERETT CODE. TAX ACCOUNT#: 00393500002106 <br /> CLIMATE ZONE 4C MARINE '��� `�`��`1, 2 X 6 STUDS AT 16" ON CENTER Fire/Planning Set <br /> STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH DESIGN ZONING: R-1 <br /> GLAZING U-VALUE, VERTICAL: /// 2 X 4 STUDS AT 16" ON CENTER ,-�,�„C 1�,�,,�,,,_,,, <br /> DRAWINGS FOR BIDDING AND CONSTRUCTION. DRAWINGS INDICATE GENERAL MAX.ALLOWED: 0.30 PROPOSED: 0.30 <br /> BUILDING HEIGHT: (NO CHANGE FROM EXISTING) GLAZING U-VALUE, OVERHEAD: EXISTING WALL TO REMAIN <br /> AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT 1235s REGISTERED <br /> MAX. ALLOWED: 0.50 PROPOSED: 0.50 <br /> B SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS ----- EXISTING WALL TO BE REMOVED A TECT <br /> SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO MAX BUILDING HEIGHT: 28'-0" <br /> DOOR U-VALUE: ------ <br /> - <br /> MAX.ALLOWED: 0.30 PROPOSED: 0.30 <br /> REVIEW AND APPROVAL BY THE ARCHITECT. LEGAL DISCRIPTION: BEVERLY HOMESITES DIV 1 BLK 000 D-06 LOT 6 OF CITY OF EV SP CEILING INSULATION: Ft - , :v -' BEARING WALL JACOB A STROBE <br /> ATE OF WASHINGTON <br /> 35-90 REC AF NO9301260644 & SURV REC AF NO 9301265001 BEING A PTN OF LOT 21 REQUIRED: R-49 PROPOSED: R-49 <br /> REFER TO DIMENSIONS AND NOTES FOR SIZES AND LOCATIONS; DO NOT SCALE ❑ POST OR POINT LOAD ABOVE <br /> DRAWINGS. DIMENSIONS ARE TO FACE OF STUD OR MASONRY WALL AND EXST PLAT VAULTED CEILING INSULATION: <br /> CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL REQUIRED: R-38 PROPOSED: R-38 - BEAM OR HEADER <br /> VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE BUILDING AREA (HEATED SPACE): ABOVE GRADE WALL INSULATION: <br /> PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF REQUIRED: R-21 PROPOSED: R-21 POST <br /> INTERIOR WALL BELOW GRADE: 0 MAIN LEVEL: 972 SF <br /> THE ARCHITECT. REQUIRED: R-21 PROPOSED: R-21 <br /> UPPER LEVEL: 694 SF Z DIRECTION OF JOIST OR TRUSS SPAN <br /> CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND MAIN LEVEL ADDITION: 1,100 SF EXTERIOR WALL BELOW GRADE: // (CANTILEVER DASHED) <br /> REQUIRED: R-10 PROPOSED: R-10 <br /> TECHNIQUES, <br /> SEQUENCES OR PROCEDURES REQUIRED TO TOTAL: 2,766 SF <br /> THE METHODS, FLOOR ABOVE UNHEATED SPACE: <br /> PERFORM THE WORK. REQUIRED: R-30 PROPOSED: R-30 < D EXTENT OF JOISTS OR TRUSSES <br /> SLAB ON GRADE: <br /> CONTRACTOR-INITIATED CHANGES SHALL BE SUBMITTED IN WRITNG TO THE SHEET INDEX REQUIRED: R-10 PROPOSED: R-10 �?�'7Ti, CHANGE IN LEVEL <br /> PROJECT DESIGNER FOR APPROVAL PRIOR TO FABRICATION OR <br /> CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT Al GENERAL NOTES, PROJECT DATA, SHEET INDEX, & LEGEND I DETAIL NUMBER/ SHEET ON WHICH DETAIL IS <br /> SATISFY THIS REQUIREMENT. TABLE R406.2 ENERGY CREDITS Al SHOWN <br /> A2 SITE PLAN <br /> A3 EXISTING FLOOR PLANS OPTION DESCRIPTION CREDITS 0 SECTION NUMBER/ SHEET ON WHICH SECTION IS <br /> EXISTING BUILDING (AS APPLICABLE) A4 PROPOSED FLOOR PLANS Al SHOWN <br /> 5c EFFICIENT WATER HEATING 1.5 <br /> & WINDOW/ DOOR SCHEDULE TOTAL 1.5 <br /> . CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS A5 ELEVATIONS <br /> 1 OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE A6 ELEVATIONS & SECTIONS 0 ELEVATION NUMBER/ SHEET ON WHICH <br /> ARCHITECT OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. S1.1 GENERAL NOTES ENERGY INFORMATION TABLE WSEC R406.2 Al ELEVATION IS SHOWN <br /> S2.1 FOUNDATION PLAN ADDITION TO EXISTING BUILDING GREATER THAN 500 SQUARE FEET OF <br /> SHORING AND BRACING SHALL BE INSTALLED TO SUPPORT EXISTING S2.2 ROOF FRAMING PLAN HEATED FLOOR AREA BUT LESS THAN 1500 SQUARE FEET. LEL SHEAR WALL PANEL TYPE PER SHEAR WALL <br /> CONSTUCTION AS REQUIRED BEFORE ANY STRUCTURAL MEMBERS ARE S3.1 STRUCTURAL DETAILS 1.5 CREDITS REQUIRED ® SCHEDULE/ SHEAR WALL NUMBER <br /> REMOVED OR BEFORE ANY NEW LOADS ARE ADDED UNTIL PERMANENT S3.2 STRUCTURAL DETAILS <br /> SUPPORT AND STIFFENING ARE INSTALLED. OPTIONS: 5c EFFICIENT WATER HEATING 6 WINDOW NUMBER - SEE WINDOW SCHEDULE <br /> GAS WATER HEATER WITH MINIMUM EF OF 0.91 <br /> DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE TOTAL CREDITS REQUIRED: 1.5 © DOOR NUMBER - SEE DOOR SCHEDULE <br /> EXISTING STRUCTURE OR VEGETATION. TOTAL ACHIEVED: 1.5 <br /> A SHOWER HEAD <br /> WHERE NEW CONCRETE OR REINFORCED MASONRY ABUT EXISTING CONCRETE IN EXISTING BUILDINGS, PER WSEC SECTION R503.1.1, EXCEPTION 2, ALL <br /> OR MASONRY, PROVIDE THREADED BARS INTO THREADED EXPANSION INSERTS EXISTING FRAMING CAVITIES WHICH ARE EXPOSED DURING CONSTRUCTION FHB HOSE BIB <br /> TO MATCH AND LAP HORIZONTAL REINFORCING UNLESS NOTED OTHERWISE ON SHALL BE FILLED TO THE FULL DEPTH WITH BATT INSULATION OR <br /> DRAWINGS. INSULATION HAVING AN EQUIVALENT NOMINAL R-VALUE. 2x4 FRAMED WALLS` 1L 4" TIGHT LINE <br /> SHALL BE INSULATED TO A MINIMUM OR R-15 AND 2x6 FRAMED WALLS SHALL <br /> CONTRACTOR SHALL CHECK FOR ROT OR INSECT INFESTATION AT ALL WALLS, BE INSULATED TO A MINIMUM OR R-21. ROOF/ CEILING ASSEMBLIES SHALL FD 4" PERFORATED DRAIN <br /> AREAS SHOWING WATER STAINS, AND ALL WOOD MEMBERS. ALL ROT SHALL BE MAINTAIN THE REQUIRED SPACE FOR VENTILATION. <br /> REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS WSEC R401.3 INSULATON CERTIFICATE PD 4" PERFORATED FOUNDATION DRAIN <br /> DIRECTED BY THE ARCHITECT. THE DESIGN PROFESSIONAL OR BUILDER SHALL COMPLETE AND POST A FILTER FABRIC FENCE <br /> "INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION" WITHIN 3' OF <br /> FF <br /> LIFE SAFETY THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. <br /> �Ds DOWNSPOUT W <br /> WSEC R403.1.1 PROVIDE A PROGRAMMABLE THERMOSTAT FOR THE PRIMARY C.)GUARDRAILS OR HANDRAILS SHALL BE PROVIDED ON ALL OPEN SIDES OF SPACE CONDITIONING SYSTEM WITHIN EACH DWELLING UNIT. _ -- -� EXISTING CONTOUR Z <br /> STAIRS OR ELEVATED PLATFORMS. GUARDRAILS SHALL NOT BE LESS THAN 36" W <br /> HIGH. HANDRAILS SHALL BE BETWEEN 34" AND 38" ABOVE STAIR NOSING. -- -� PROPOSED CONTOUR N OPENINGS SHALL RESTRICT A 4" DIAMETER SPHERE FROM PASSING THROUGH. WSEC R404.1 A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED 0 <br /> HANDGRIPS SHALL NOT BE LESS THAN 1 1/4" NOR MORE THAN 2" IN LAMPS IN LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS. - 000, <br /> + 123.4 EXISTING SPOT ELEVATION � Q <br /> CROSS-SECTIONAL DIMENSION. RETURN HANDRAILS AT ENDS. W (I)FANS SHALL VENT DIRECTLY TO EXTERIOR OF THE BUILDING. FANS TO i-- <br /> OPERATE CONTINUOUS. +MC PROPOSED SPOT ELEVATION Cl) <br /> DOOR AND WINDOW NOTES �� <br /> VAPOR RETARDERS SHALL BE INSTALLED AS SPECIFIED IN WSEC R502.1. 2 REVISION 0 w <br /> WINDOW SUPPLIER SHALL REFER TO EXTERIOR ELEVATIONS AND SCHEDULES > co w <br /> FOR CONFIGURATION AND OPERATION OF ALL WINDOW AND DOOR UNITS. EXTERIOR JOINTS SHALL BE SEALED, CAULKED, GASKETED, OR "sD SMOKE DETECTOR <br /> . MAINTAIN ALIGNMENTS AND FORMATS TO MEET DESIGN INTENT;ADJUST WEATHERSTRIPPED. <br /> ROUGH OPENINGS AS NECESSARY. SUBMIT SHOP DRAWINGS FOR APPROVAL. amp CARBON MONOXIDE DETECTOR <br /> ALL WINDOWS AND DOORS TO BE INSTALLED PER MANUFACTURER'S OUTDOOR AIR INLET/S TO BE PROVIDED BY USING EXHAUST FANS PER IRC <br /> REQUIREMENTS. M1507.3.4.4. PER WSEC M1507.3.4.4, OUTDOOR AIR SHALL BE DISTRIBUTED TO EXHAUST FAN <br /> EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE <br /> WINDOWS LABELED "EGRESS" ON DRAWINGS SHALL FULFILL FOLLOWING OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY O THERMOSTAT REVISIONS BY <br />• REQUIREMENT: 5.7 SF MIN. NET CLEAR OPEN AREA; 20" MIN. CLEAR OPEN DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY <br /> WIDTH; 24" MIN. CLEAR OPEN HEIGHT; 44" MAX. SILL HEIGHT. INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, <br /> It is owners responsibility to establish gag stab eft INTALLATION OF'/2 GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE ABBREVIATIONS <br /> EXTERIOR DOORS SHALL HAVE MIN. ' THROW ON DEAD BOLT OR DEAD LATCH property lines. <br /> AND VISITOR OBSERVATION PORT. WINDOWS WITHIN 10' OF GRADE OR UNDERCUT TO A MINIMUM OF 1/2 INCH (12.7MM) ABOVE THE SURFACE OF THE <br /> ACCESSIBLE DECK MUST BE CAPABLE OF BEING LOCKED. ALL LOCKS, FINISH FLOOR COVERING. <br /> INCLUDING DOOR LOCKS, MUST BE ABLE TO BE OPENED WITHOUT THE USE OF IF BUILDING IS NOT POSITIONED AS APPROVED B.O.W. BOTTOM OF WALL <br /> PLANNING &COMMUNITY PER WSEC TABLE R402.1.1 - WINDOW & DOOR HEADERS SHALL BE INSULATED C.B. CATCH BASIN <br /> A KEY OR SPECIAL KNOWLEDGE OR EFFORT. INDICATED ON APPROVED SITE PLAN, , <br /> A NEW SITE PLAN SHALL BE SUBMIT- DEVELO MENT DEPT. <br /> WITH A MINIMUM OF R-10 INSULATION. CL CENTERLINE <br /> TED. NO FURTHER INSPECTIONS WILL BY <br /> WINDOWS WITHIN 24" OF A DOOR AND WITHIN 60" OF FLOOR, WINDOWS WITHIN U C.O. CLEAN OUT <br /> BE MADE ON THIS PROJECT UNTIL THE <br /> 18" OF FLOOR, GLAZED DOORS, AND ALL SHOWER OR TUB ENCLOSURES SHALL REVISED SITE PLAN HAS BEEN APPROV- DATE / + CARBON MONOXIDE ALARMS CONC. CONCRETE <br /> HAVE SAFETY GLAZING. ED BY THE BUILDINGIPUBLIC WORKS CMU CONCRETE MASONRY UNITS <br /> DEPTS. REQUIRED LOCATIONS PER IRC R315.3: APPROVED CARBON MONOXIDE DN DOWN <br /> MISCELLANEOUS ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA EL. ELEVATION <br /> GRADING AND DRAINAGE A Benchmark Is Required On Site IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EACH LEVEL OF THE EQ. EQUAL <br /> INSTALL DRAFT STOPS IN FLOOR-CEILING ASSEMBLIES SO THAT CONCEALED 1. Provisions shell be made for the control and drainage of surface To Verify Approve? Building Height DWELLING IN ACCORDANCE WITH THE MANUFACTURER'S E EXISTING <br /> SPACE DOES NOT EXCEED 1000 SF. FIRE BLOCK PER IRC R903. water around buildings by: gutters, drain lines, inlets and catch RECOMMENDATIONS. WHERE A BEDROOM OR ITS ATTACHED BATHROOM EW EACH WAY <br /> basins or other necessary drainage structures and shall be installed ma <br /> ITumtriEgz PUMPS AND CONTAINS A FUEL-BURNING APPLIANCE, A CARBON MONOXIDE ALARM MUST EXT'G EXISTING <br /> SOLID FUEL-BURNING APPLIANCES, INCLUDING FIREPLACES, SHALL HAVE TIGHT where storm water disposal cannot be obtained without their use or APPURTENANCES CONCRETE-ENCASED ELECTRODE BE INSTALLED IN THE BEDROOM. F.F.E. FINISHED FLOOR ELEVATION <br /> FITTING METAL OR GLASS DOORS AND OUTSIDE SOURCE OF COMBUSTION AIR , where erosion cannot be prevented by finish grading and planting. AND NOT BE LOCATED IN THE FRONT (UFER GROUND) REQUIRED0/C ON CENTER <br /> AND SIDE SETBACKS.PROPANE TANKS EXISTING DWELLINGS PER IRC R315.2.2 SHALL BE EQUIPPED WITH CARBON <br /> WITH AN OPERABLE DAMPER, DIRECTLY CONNECTED TO THE FIRE BOX, AND Dry wells shall not be installed in areas where the soil is not well REQUIRE ADDITIONAL PERb41TS ISSUED PER NEC 250.50 MONOXIDE ALARMS IN ACCORDANCE WITH THE INFORMATION ABOVE (SOME P/B PLANTING BED <br /> TIGHT-FITTING, READILY OPERABLE FLUE DAMPER OR APPROVED AUTOMATIC drained and,jor porous. PRIOR TO INSTALLATION.EPARTMENT (INSPECTED AT FOOTINGS) EXCEPTIONS MAY APPLY). AN INSPECTION WILL OCCUR WHEN ALTERATIONS, SIM SIMILAR <br /> CONTROL. METAL FIREPLACES AND CHIMNEYS MUST BE UL- OR ICC-APPROVED REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR T.O.W. TOP OF WALL Date 11/7/2019 <br /> 2. Grading shall be provided to insure: MORE SLEEPING ROOMS ARE ADDED OR CREATED. BATTERY POWERED TYP. TYPICAL <br /> AND MUST BE INSTALLED PER MANUFACTURER'S REQUIREMENTS. (a) Diversion of water away from buildings. ALARMS ARE PERMITTED IN EXISTING DWELLINGS. U.N.O. UNLESS NOTED OTHERWISE Scale <br />' Ib) Prevention of standing water and soil saturation detrimental Additional Permits Are Required <br /> COMBINATION ALARMS PER IRC R315.4 COMBINATION SMOKE AND CARBON V.I.F. VERIFY IN FIELD <br /> Project For This P ect To Include: Drawn <br /> to structures and lot use. MONOXIDE ALARMS MAY BE USED IN PLACE OF CARBON MONOXIDE ALARMS. W/ WITH <br /> (c) That natural drainage channels or basins are not blocked POWER SOURCE PER IRC R315.5 CARBON MONOXIDE ALARMS SHALL <br /> El Plumbing 0Sprinkler CITY OF EVERETT Job <br /> Roof trusses to be designed <br /> filled. and drawing prepared by RECEIVE PRIMARY POWER FROM THE BUILDING WIRING AND, WHEN POWER REVIEWED FOR PERMIT <br /> Id) Provisions for the disposal of water from a lot. a State licensed structural Mechanical ❑ Fire Alarm IS INTERRUPTED, SHALL RECEIVE POWER FROM A BATTERY. Sheet <br /> te) Protection of adjoining property, engineer. Ig Electrical <br /> PERMIT SET 11 /7/2019 Al <br />