CITY OF EVERETT SPECIAL PROVISIONS <br /> 7-05.3(5) Furnish and Install Solid Cover for Catch Basins <br /> Provide new solid covers on existing catch basins where shown on the Plans. <br /> Provide solid covers conforming to 9-05.15 of the Standard Specifications, 9- <br /> 05.15(1) of these Special Provisions, and to COE Standard Drawing No. 410 for <br /> Type 1 and 1L Catch Basins and COE Standard Drawing 610 for Type 2 Catch <br /> Basins. <br /> 7-05.4 Measurement <br /> Delete all paragraphs of 7-05.4 and substitute the following: <br /> Bid items of Work completed pursuant to the Contract Documents will be measured as <br /> described in Division B — Bid Item Descriptions of these Special Provisions and Section <br /> 1-09 MEASUREMENT AND PAYMENT of the Standard Specifications. <br /> 7-05.5 Payment <br /> Delete all paragraphs of 7-05.5 and substitute the following: <br /> Payment for bid items of Work completed pursuant to the Contract Documents will be <br /> as described in Division B — Bid Item Descriptions of these Special Provisions and <br /> Section 1-09 MEASUREMENT AND PAYMENT of the Standard Specifications. <br /> 7-06 STORM WATER QUALITY TREATMENT STRUCTURES <br /> (******) <br /> 7-06.1 Description <br /> This Work consists of furnishing and installing Bypass Structure(s), Vortex Pretreatment <br /> device(s) and Stormwater Biofiltration System of the size and model specified and in <br /> accordance with the configuration and location shown on the Plans and these Special <br /> Provisions. <br /> 7-06.1(1) Water Quality Treatment Units <br /> Bypass Structure Type-C <br /> The Bypass Structures Type-C shall be fabricated in accordance with the Drawings, <br /> applicable Standard Drawings and the requirements of the Design and Construction <br /> Standards and Specifications. The device includes a standard Type 2 catchbasin <br /> containing fabricated flow control risers. <br /> Vortex Pretreatment Device <br /> The Vortex Pretreatment device shall be: CDS® device manufactured by Contech <br /> Engineered Solutions LLC, of type and configuration indicated in the Drawings, or <br /> approved equal. <br /> Stormwater Biofiltration System <br /> The manufacturer of the stormwater quality treatment structure shall be one that is <br /> regularly engaged in the engineering design and production of systems deployed <br /> for the treatment of storm water runoff for at least five (5) years and which have a <br /> history of successful production, acceptable to the Engineer. <br /> The manufacturer shall guarantee the stormwater quality treatment unit <br /> components against all manufacturer originated defects in materials or <br /> workmanship for a minimum period of twelve (12) months from the date the <br /> components are delivered to the owner for installation. The manufacturer shall <br /> upon its determination repair, correct or replace any manufacturer originated <br /> defects advised in writing to the manufacturer within the referenced warranty <br /> period. <br /> Jackson Park Area Stormwater Separation September 2020 <br /> WO No. -UP3703 Division 7—STORM, SEWER,WATER <br /> SP-157 <br />