R L Alia Company 12/7/2020
>
Contracts
>
Capital Contract
>
R L Alia Company 12/7/2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2021 1:38:29 PM
Creation date
12/9/2020 12:33:15 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
R L Alia Company
Approval Date
12/7/2020
Council Approval Date
11/10/2020
Department
Public Works
Department Project Manager
Tom Fuchs
Subject / Project Title
Jackson Park Area Stormwater
Public Works WO Number
UP3703
Tracking Number
0002555
Total Compensation
$12,326,000.00
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
R.L. Alia Company 5/4/2021 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
407
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT SPECIAL PROVISIONS <br /> points can be installed along the proposed trench line alignment to remove perched <br /> water zones prior to excavation. <br /> Before dewatering operations begin, the Contractor shall have available on the <br /> Work site sufficient pumping equipment, or other machinery, or both, to assure <br /> maintaining continuous operation of the trench dewatering system. Supply power <br /> service to dewatering pumps including, but not limited to, electrical, hydraulic, gas, <br /> or diesel, Maintain the dewatering system to allow for continuous operation without <br /> interruptions. If necessary, provide 24-hour supervision and follow-up by personnel <br /> skilled in the operation, maintenance, and replacement of dewatering system <br /> components. Damage to Work in place and the excavation, including damage to <br /> the trench bottom, due to "boiling", material removal, or discharge pumping from the <br /> excavated area, that may result from negligence, inadequate or improper <br /> installation, maintenance and operation of the dewatering system, or mechanical or <br /> electrical failure of the dewatering system shall be Contractor's responsibility to <br /> repair at no cost to the City. <br /> Trench dewatering shall be included with the Work required for Storm Drain Pipe, <br /> Manholes, Inlets, Storm Drain, Catch Basins, Utility Restoration or other excavation <br /> activity performed as part of this Contract with no direct compensation made. <br /> 7-08.3(2)A Survey Line and Grade <br /> Delete both paragraphs of 7-08.3(2)A and substitute the following: <br /> Provide surveys required to construct the sewer line including, but not limited <br /> to, alignment stakes, offset stakes, grade hubs, and intermediate staking. Use <br /> main survey control points shown on the Plans, unless Engineer directs <br /> otherwise. If a Bid item for "Surveying" is not listed in the Proposal, then this <br /> item shall be included with the Work with no direct compensation made. <br /> Provide laser control equipment approved by the Engineer for setting pipe <br /> grades. <br /> 7-08.3(2)1 Side Sewer Connections <br /> Supplement 7-08.3(2)1 by adding the following: <br /> Make typical side sewer connections in accordance with COE Standard <br /> Drawing No. 602. <br /> 7-08.3(2)J Pipe Separation Pads <br /> Where vertical clearance between a proposed pipe and any other underground <br /> utility is 2 to 6 inches a pipe separation pad is required. The pad shall be 2 feet x <br /> 2 feet x 2 inches minimum and placed between the pipes. The pad shall be <br /> polyethylene (Dow Plastics Ethafoam 220) or approved equal. <br /> Pipe separation pads shall be included with the Work required for Storm Drain pipe, <br /> performed as part of this Contract with no direct compensation made. <br /> 7-08.3(3) Backfilling <br /> Delete the first paragraph of 7-08.3(3) and substitute the following: <br /> Perform trench backfilling only after inspection and approval of the installed pipe <br /> bedding zone backfill. Refer to COE Standard Drawing No. 614, 615 and the Plans <br /> for typical trench section backfill and compaction requirements. <br /> If the Engineer determines native material is not suitable for use as trench backfill, <br /> use "Gravel Borrow" conforming to 9-03.14(1) of the Standard Specifications. <br /> If there is an excess of suitable backfill material obtained from trench excavation at <br /> one location on the project, use it at other locations on the project or dispose of at <br /> Jackson Park Area Stormwater Separation September 2020 <br /> WO No. -UP3703 Division 7—STORM, SEWER, WATER <br /> SP—163 <br />
The URL can be used to link to this page
Your browser does not support the video tag.