|
OTOP241737 = _ _ _ _ _ = g
<br /> CN0�241737 CONSTRUCTION N4TES LEGEND PTN. OF SE 1/4 OF SEC. 17, TV1/P 29., R5E W.M. � � � � � � � �
<br /> CUSD241737 N0�
<br /> m o 0 0 0 0 �
<br /> i" WATER SERVICE AND METER PER COE STD. 1. ALL WATER VALVES SHALL BE PROVIDED WITH VALVE BOX AND m m � c�i c�,� v c�,� �
<br /> CUWS241737 OO DWG. 501 w 1" BACKFLOW ASSEMBLY DCVA � PUBLIC UTILITY EASEMENT - - -� WATER METER AND SERUICE UNE
<br /> TBLOCK PER COE S�. DWG. 520 ( , OPERATING NUT EXTENDED PER COE STD. DWG. 505. • „ .
<br /> z
<br /> ASIT241737 4" FIRE SERVlCE SUPPLY LINE (SEE FIRE -� FIRE DEPT. CONN. (FDC) � ��-,
<br /> CSIT241737 �� SYSTEM NOTES '� 2. MEGA LUGS SHALL BE INSTALLED AT ALL BENDS AND FlTTINGS �' �
<br /> OLN0241737 O 2" WATER SERVICE AND METER PER COE STD. � IN ACCORDANCE W1TH COE STANDARDS. ALL PIPES AND Z � �
<br /> cuws241737-ds n OWG. 502 w 2" BACKFLOW ASSEMB�Y DCVA -F- FIRE SERViCE ,.
<br /> 9 � � � POTHOLE EXIST. WATER MAIN TO VERIFY FIT71NG5 SHOWN AS RESTRAlNED JOINTS (RJ) SHALL BE �°-, � m
<br /> PER COE STD. DWG. 520 �� LOCATION OF 8" SEGMENT STORM DRAIN MEGALUG GASKET OR APPR01/ED FQUAL. Q o � � �
<br /> ODOUBLE CHECK DETECTOR VALVE ASSEMBLY r-, � `" � � ¢
<br /> 3 12 SAWCUT, REMOVE AND REPLACE EXIST. PVMT. ��� SD CATCH BASIN 3. DOMESTIC WATER SERwCE SUPPLY SHALL INCLUDE A DDUBLE Z � m
<br /> (DCDA) VAUL� PER COE STD. OWG. 515, SEE CHECK VALVE ASSEMBLY (DCVA) INSIDE BUILDING MECHANICAL m � � W � Y
<br /> FIRE SYSTEM NOTE 3 O � v, � W W
<br /> 13 BLOW OFF ASSEMBLY PER COE STD. DWG. 511 SS SANITARY SEWER MAIN ROOM W/MATERIAl.S AND CLEARANCES PER COE S1D. DWG. � �,, � Q � c=,
<br /> 5 2 0, R E F. P R O J E C T P L U M B I N G P L A N S/D E T A I L S. � � W � � �
<br /> � 2" FIRE SERVICE SUPPLY LINE SEE FIRE 6" FIRE SERVICE SUPPLY LINE (SEE FIRE � � z u, c, m m
<br /> ( STD. PRECAST MANHOLE a Z � W = Z
<br /> O S Y S T E M N O T E S) 14 S Y S T E M N O T E S � I �� `� 4. T H E C O N T R A C T O R S H A L L V E R I F Y A L L S A N I T A R Y S E V I�R, c n � � � o � � "
<br /> � ----'-- � � � DOMES77C WATER, AND FIRE SERVI�E CONNECTIONS SHOWN ON z o r 3 m � � o
<br /> S I D E S E W E R S E R V I C E , Y � a W W w ¢
<br /> OFIRE HYDRANT ASSEMBLY PER COE STD. DWG. » x � V`'.'•-, �� T H I S P L A N W I T H T H E I N F O R M A T I O N P R O V I D E D (N T H E P R O J E C T o � ¢ � � LL
<br /> 507, APPROX. 6" DI LENGTH PER P1�4N 3 W A T E R S E R V I C E A N D M E T E R V A U L T S I M. C O E � SIDE SEWER CLEANDUT �� e d P L U M B 1 N G A N D F I R E S P R I N K L E R P L A N S/D E T A I L S A N D N O T 1 F Y � � � Q � � �.�' o
<br /> 1 5 S T D. D W G. 5 0 4, B A C K F L O W A S S E M B L Y T O B E �� �:�,: .
<br /> LOCATED IN BLDG. MECHANICAL ROOM yy WATER MAIN � .\rpa��o�r ENGINEER OF ANY VARIANCES PRIOR TO CONSTRUCTION. � a 3 � � m m �
<br /> 6 POST INDICATOR VALVE (PIV), SEE FIRE SYSTEM �, ��. ; ; � e�, -�r aoR .
<br /> O NOTE 3 ��� � O rePa�otireCs�e`aa5e ov�a 5. ALL WATER MAIN PIPES SHALL BE DUCTILE IRON, CLASS 52 rn rn rn o 0 o N �
<br /> - - - - - - - WATER SERVI CE ��'- .\ � � � � ��► beer peday .\��a� �or 5r » W � � � `'' � N �
<br /> , ` � (`� ra5 to,,�a aca� �,�.�pt WITH A MIN/MUM COVER OF 36 UNLESS OTHERWISE NOTED d N � � � N � �
<br /> O7 F/RE DEPARTMENT CONN. (FDC) _ , _ _ � �< �, � � •� �' �✓ ���t�or p tr�s ce5 � AN� APPROVED BY THE CI TY. o � � N � � � �'
<br /> P U B L I C U T I L I T Y E S M T. ` �� . � pca�' a a rd �,op ��acy• C�� � � � M M .�
<br /> „ `. ��, �� ° ; e�°`a^�rtO�ma��0r at�0r' a�° 12" te
<br /> 8 i IRRIGATION METERED WATER SERVICE PER � � , � �1 :' ` .�s� ���ti <n` r�` pa
<br /> �� � F�RE HYDRANT (FH) �� : �� `� �r ,P56 ;���r�� �e�rt� �,�oc 6. CDE WATER DEPT. CREWS SHALL MAKE ALL CONNECTIONS TO Z �a 4 � � �
<br /> COE STD. DWG. 501 w/ � BACKFLOW ASSEMBLY .\ �� �� � � "� • � or a 5a� a��aa.,��tre ,��rspe ACTIVE PUBLIC WATER MAINS UNDER SEPARATE UPLITY PERMIT
<br /> (DCVA) PER COE STD. DW 520. CONTRACTOR � �•� `� � tire ae a e�a� � Qet�`` CONNECTION FEE SHALL BE BASED ON A COST ESTIMATE BY
<br /> TO INSTALL � DOMESTIC BACKFLOW ASSEMBLY (DCVA) .\\ � ;. �\ ��\\ � � � ".�, ` tr�e d THE WATER DEPT. AND WORK SHALL BE AT OWNERS EXPENSE. ,�w r
<br /> . � ���;� . 1�
<br /> 2 STA 26+05.59, 40.05 LT `�\�T� ��\ � � � ''_ ; 8y FIRE SYSTEM NOTES ��' A
<br /> A. __ \\�.\ .+?� � `�`� \ � \ t -;•., ` ��re �e �`��� 1. FIRE SERVlCE SUPPLY LINE SIZES SHOWN ARE APPROXIMATE. � �
<br /> �Q�� y 6 BLD . B 8 `�\ �, ��\ �, �� � .: Qc\r�,Na ACTUAL LINE SIZES SHALL BE PER FIRE PROTEC170N ENGINEER.
<br /> G \ \�. �`� `."tS� � � _;-, 2. COE UT1LlTY SERVIC S DEPARTME F �"�
<br /> G � E NT SHALL HAVE ACCESS TO ,��, T�
<br /> �V �� �� � ��� ��� � � � � MECHANICAL ROOMS DURING THE HOURS OF 7:30AM TO S ONAL �Y�
<br /> � � �� � STA 26+18.11, 20.71 �, �� � 4:OOPM, MONDAY THROUGH FRIDAY. �f�,�
<br /> �� � �' '
<br /> ` BLDG. A � �
<br /> �
<br /> 5 STA»26+08.86, 6.00' RT , ° l� � `� '� ` � STA 26+19.11, 18. ' \\`� \\�� �� � 3. FIRE SERVICE SUPPLY FOR THE BUILDINGS A, B, E, F, G, AND �.�
<br /> (1)8 x6 DI TEE, MJxFL \ , � � BLDG. B � �`�` �`���� ` J SHALL lNCLUDE A DOUBLE CHECK DETECTOR ASSEMBLY
<br /> (1) �" FH ASSEMBLY � � / J ,� •� �� � � cuY (DCDA) tNSIDE BUILDING MECHANICAL ROOM PER COE STD. y
<br /> (1) THRUST BLOCK . � 4� �C �� ��\ ��\ � wiR� DWG. 523. FIRE SERVICE SUPPLY FOR BUILDINGS C, D, AND H
<br /> SEE C4.O4 12LF 6 Dl, RJ /�`�`, ` � �\ � - �\ .�� � SHALL INCLUDE A DCDA IN AN EXTERIOR VAULT PER COE S7D.
<br /> � , � � � � � � • � � � DWG. 515. POST INDICATOR VALVE (PIV) AND FIRE
<br /> ; I � �`, ��, STA 35+03.59, 15.88' L �` � �`�` ��.� �/ DEPARTMENT CONNECTION (FDC) FOR BtIILDiNG J SHALL
<br /> �� � � I �� � �, � � �
<br /> - r CONNECT TO FIRE SUPPl.Y SERVICE LINE DOWNSTREAM OF
<br /> , � ; � ��� , �` ': t. S --�---- DCDA. ONE-WAY CHECK VAL VE FOR FDC SERVICE SHAtL BE �
<br /> I � � � , 3 �I I � \ � �� S T A 3 4+9 9.5 9, 1 4.5 �. • � � � I N S T A L L E D 1 N S I D E V A U L T O R M E C H A N I C A L R O O M. A L L F I R E
<br /> � I ' I � � � `� � \ � � � ` ��<� � S P R I N K L E R S U P P L Y L I N E S A N D A P P U R T E N A N C E S S H A L L B E o
<br /> �,�I � i iI � `,� �'0 1NSTALLED PER SECTION 5-17 OF CDE DESIGN AND �
<br /> °' � RD - � \ � \ � G `� � D° \ CONSTRUCTION STANDARDS AND SPECIFICATIDNS. FIRE z
<br /> I M �i V mI i� ��� `k � � � 42 04'55"W .02' SPRINKLER SYSTEM DESIGN AND CONNECTtON DETAILS SHALL �
<br /> � �' v� 3 i � � PLAYAREA #2 �� � `�\ , �; �, BE PROVIDED AND APPROVED UNDER SEPARATE PLUMBING 3
<br /> � � � �I �I 0 10 STA +15.30� 6. \ \ �� � , '\ �,
<br /> PERMI T. �
<br /> � ,
<br /> O �
<br /> N � U i � i \ l� Q �\ �� �\ z
<br /> � � � � �� � �� \ 4� �� �� p ''d \� � �
<br /> I ^ i U Q � - I �� �O� �j `� �' 1x � \ \ ' STA 11+18.33, 113.57' RT �^ v
<br /> � i � i � `� \ G �o ' 1 � � , BLDG. C � V J =
<br /> I �� U T A �I Q ' \\�� \ ��+ \ � /�� �O ,y\\ \ � �
<br /> � V o � � STA 20+28.02, 4.00 RT STA 32+01.57, 18.50' LT ` �� �'o ,�' �•� � � 7 _
<br /> I � + �I (1) 8 DI TEE, FL � BLDG. J � � ' �' � �'' L o
<br /> � v IN � I (1) 8"ADAPTER, FLxMJ � `, A + .7 `.\ ,�' C `� \ :'`.� BL � W �
<br /> I �� c,� I � �I � (2) 8 DI �V, FLxMJ 5 STA»31+95.20, 11.00 RT B/KE STA 28+05.71, 17.98 RT �\ (�) x4 ' N \ , � � \ � : � �
<br /> � 1 i (1) THRUST BLOCK (1)&x6 DI TEE, MJxFL SHELTER#1 � BLDG. 0 ' `, � � Q � \ � STA 76+38.00 14.40' LT
<br /> n ' x .n �� � (1) 8" DI TAPPING TEE, MJxFL �
<br /> � � ;I (1) 5✓4 FH ASSEMBLY , `, !y �o -!r `. �- r 3 � . 1 8" DI GV FLxMJ
<br /> ; U I 3 i o (i) T H R U S T B l.O C K � S T A 2 8+1 9.9 0, 7.8 2 R T `, � � �!i � � ��. � � ' �""�
<br /> EX1ST. 20' CI TY OF EVERETT ; � � 7 L F 6� D I S P O O L (1)8 x6" DI TEE, MJxFI � � � �' f \
<br /> PUBLIC UTILITY ESMT. REC. (1) THRUST BLOCK �/
<br /> + � \ � � � � � � � ',� CONN. EXIST. LL. �' '
<br /> � � I � i STA 30+88.75 39.49' LT (i) 5✓4" FH ASSEMBLY \ � SEE NOTE 6 � �
<br /> N0. 8005020229) % v � � o ' 8 (1) THRUST BLOCK o ` \ . �. � •
<br /> , U �I � 15 � 11LF 6" Dl, RJ �� � o� �,, � , � ' �� � '.�_: STA»35+63.26, 57.58 LT 5 �
<br /> -- ---- � ; ` �� \ '� / � � � fi (1)$ x6 DI TEE, MJxFL � W
<br /> '� � -��-- �J �I � „ � POOL �� � (1) �" FH ASSEMBLY Q �'
<br /> � ` � C � (1) THRUST BLOCK U�
<br /> 4LF 8 DI '� q ` � ` M ' 19LF 6" Dl, RJ �
<br /> 122�0 +OO �OB Z � �I RD Rp --- RD ---- D LJ° �� F F F ii� � ` �
<br /> ' �
<br /> � � ftD � �
<br /> W _ --- ----_----- - - �' 6 BLDG. J �� � �
<br /> v ! 7LF 8" 1 I - �__--_-- --- - ------ -- �` ---- -- --- - - - --_- ----_-�------ - - - • r, '� � \ � �� �. �� � W � Z
<br /> , .
<br /> .:... . -- --- .
<br /> ' . � 1 L14 " � DI I � I F w 3 /N U UD ------------ :: � `� 3 � .\ ._ -
<br /> . ,� , �� � y � � , � g
<br /> , ,, � - �
<br /> 12LF 8 � 4.
<br /> �SEE C4.04 � STA 30+33.48, 1�.0 RT � - _ ° '� �,�F $� `, H ` V � �
<br /> � � � � �,� R�Y�" ni ---I-_ ��j�-�E F »��: �g `�\ 5LF 8 D \\\ � J iW- �
<br /> �' --- -- + - ( " _ _ _ ss - �� � �
<br /> _ , ..,
<br /> . M � .._._ +o � 33 p �_ • ` � '' ' V"� m '� >
<br /> ------ . ..
<br /> i (1) THRUST BLOC - o +o S 95LF 8" DI i � � � .':, � � o
<br /> � W w 128L.F D1_ �. - � I;F 8 DI 3s+ S � � Q "
<br /> S8739'15'� 11 71' � v ,�� ..::. ( W W �: W______� 167LF� pl W - � BLDG. F 6 `` � 99'3�;-�94'--.R T i . ,f \ � N �
<br /> STA 30+04.00, 6 0�' T I ' � � � � W (1) 8'�l4 BEND, MJ i \\ �■� c� ,
<br /> � 1 THRUS BLOCK �
<br /> (1) 8 x45' BEND, �------ � ' I ��- I �+ i �
<br /> 1) THRUST BLOC I v � _ _ _ _ - 'I _ � , I' 31 F 8 D! � � � � � � '.�.': CUENT
<br /> � / I I i � --- - _ _________- A `
<br /> _..�_ _
<br /> r ----------- _ � \ ' ,`
<br /> r;
<br /> I I I U � � T � � -------- \ � ,- '
<br /> ....
<br /> --- \ �- �
<br /> S►A 3O-FO9.00� ��. O� �T I I R� � i �__� D - RD ___ RD Rp RD RD D i RD ---- D -�y- -- ----- ...... ------- ---------- ------ BIKE \ � \ t ,
<br /> (1) 8"x45' BEND, ' v '` ' Ro - ' - - ,
<br /> � � �� RIVERVIEW I, LLC
<br /> 4 L S D I � � R� - RD Ro ____ SHELTER#3
<br /> (1) THRUST BLOC � � v � 6 BLDG. G Ro � o F STA 32+30.3 0' RT - F � ��-- RD R - RD - R� � Rp ___._�� � � � 10900 NE 8TH STREET
<br /> I � �' 4i+oo DR/VE D I �B�KESHELTER#2 � � (1) 8"x6" TEE - 14 '� - � ' \ BELLEVUE, WA 8004
<br /> 5 STA 30+19.20 1100' RT� � - � - 42 00 0 , � ,
<br /> .� � » ' i � �- � --- � � 1 6" DI GV Lx STA 33 . 9, 11.00 RT E STA 34 5 6, 1 i.00' RT STA 35+59.3 �5 93 LT ,�; .
<br /> (1) 8 x6 DI TE , JxFL � U 1 � � �
<br /> r � q ¢ ( 10 � PHONE: (425)453-9551
<br /> � �iJ I � R� - RD ic---- RD -- RD - RD -- DOG � (1) THRUST BL C \ � » � PLMY \ " H � • � \�
<br /> 3 Ro 1 8" MJxFL 1 8"x4" DI JxFL �
<br /> (2) 8 DI GV, RD,�____ Ro �.j 1 8 G , FLxMJ 3 ,
<br /> � (1) 5�4" FH ASS BLY � ' � A 1+ . , . � ) (1) 4 DI GI/ MJx , � '` O
<br /> i (�,, RUN (1) THR S BLOCK AREA STA 34 5 82, 1 i.OQ RT 10 ��� J�-JRUST B \ � . � �
<br /> C C C C C � � #3 (1) 8 x 4 1 T E E, M J x F L �� - ,
<br /> � (1) T H R U S T B L C� I C
<br /> � " � � STA 4+ .71, 11.00 RT � \ • , �
<br /> � S L F 6 �! S P O O L I I � 6 B L D G. E (1) 4 V, M J x F L :�
<br /> �
<br /> I `\ o d _ -� __ (1) US LOCK � �`�.. . : �
<br /> ---^--J TRA
<br /> � Sl'S9'14"W 12.55' - _ - � �
<br /> Y ' ----\ ..:.�.-.-,L._,-�,,:� . ' � �
<br /> � �_ -� _ _ ..` -._....-.� --- , _ � STA 34+54.82, 40. R 2
<br /> � � ------------- ' - - � �
<br /> ---------
<br /> � STA 40+24.58, 19.21 L ---- - - � . L
<br /> � E
<br /> \
<br /> -_____ _ - - . , \ ':
<br /> ---------------- - � - -
<br /> ---- ____ 9 .
<br /> ---------------- -
<br /> CONSU TANTS
<br /> � BLDG. G
<br /> --------------------- �� , oe .
<br /> _ ---------------
<br /> J ------------------- .
<br /> m � I ----------------------------
<br /> N ------- ------- �
<br /> iw - - - - - -S-i'A-�+ 64, 11.00' RT . , , ---------------------------------------------------- � - --- - -- -- -- -��=�-__ LandscapeAchitegtuel•IlLandlUselConsulting
<br /> -----
<br /> � � „ „ _ - - S88 02 03� 774.27' -----------------------------------' � ' � � 11321-B NE 120th 5treet
<br /> � Q {�1 $X4 � �E, MJxFL � � ' - - - - - ._ _ _ n Kirkland,WA 98034�(425)285-2390
<br /> u� � I I I ��� �� �� V, FL I I � ' 101 South Wenatchee Avenue,Suite C3
<br /> Wenatchee,WA 98801�(509�293-7731
<br /> �o � � (1) 4z3" EDUCER, MJxFl. I � I STA 34+29.91, 18.50' RT 7 www.cphconsuitants.com
<br /> � J (1) THRUST BLOCK � ' BLDG. E �
<br /> /o
<br /> r �
<br /> o � STA 34+28.24 18.50' RT � PROJECT N0.
<br /> � � ' 7 , 0024-17-037
<br /> �� BLDG. F �
<br /> Q DRAWING
<br /> o � STA 34+11.13, 41.03' RT 2 N �
<br /> �o �
<br /> C4
<br /> �o 0 0 30 60 Know what's b@IOW.
<br /> . �� CBII before you dig. SHEET 30 oF 4�
<br /> a � PLAN IN FEET Copyright m 2020 CPH Consultants,ILC. All Rights Reserved. .
<br />
|