• • <br /> Done. See: 19.Specify the R-Value of all installed insulation in the floor,walls and ceiling. <br /> 5-A201 <br /> 6-A201 The insulation values shown on the Wall Section and the Building Section drawings do not meet the <br /> minimum requirements for insulation as specified in Table R402.1.1 WSEC 2015 ed. <br /> 7-S101 <br /> Done. See: 20.All stairs shall have a landing at the top and the bottom. Show landing at the bottom of the exterior <br /> 1-A101 stairs on the plans. <br /> 2-A101 Show size,material and placement(with dimensions)of the proposed landing at the front porch. <br /> Done. See: 21.Provide framing plan and foundation plan for the exterior porch. <br /> 1-S101 <br /> 2-S101 <br /> Specify the size,species and grade of all framing members at the front porch.Provide section detail. <br /> The following corrections were not included in the original correction letter. <br /> 1.All section drawings and details that show dimensional lumber where TJI joists are proposed, shall be <br /> revised to show TJI joists as specified. <br /> Done. See:all that apply <br /> Please change 2x10 TJI 210 Joists to 9-1/2"TJI 210 Joists" <br /> Done. See:all that apply <br /> 2.Call out the specific hangers where joists and stringers attach to the floor faming. <br /> Done. See: 7-S101, 10-S101 <br /> 3.Solid blocking is shown at the top of the wall with no ventilation openings. Specify the size and quantity <br /> of openings in each block(see#14 above). <br /> Done. See: 7-S101 <br /> 4.A shearwall schedule is provided but no shearwalls are designated on the plans. All braced wall lines <br /> and braced wall panels shall be clearly identified on the floor plans. <br /> Done. See: 1-A101, 3-A101 <br /> 5.The plans show two Heat Recovery Ventilation Systems(HRVS) used to comply with the requirement <br /> for"Additional Energy Efficiency Requirements"per Table 406.2 WSEC.The requirement for the HRVS is <br /> that the "heat recovery ventilation system" is shown on the plans. Show the location of all proposed <br /> duds for the HRVS. <br /> Done. See: 1-A101 <br /> Wahington State Energy Code Table 406.2 Option 2c; <br /> AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: <br /> Compliance based on Section R402.4.1.2:Reduce the tested air leakage to 1.5 air changes per hour <br /> maximum <br /> and <br /> All whole house ventilation requirements as determined by Section M1507.3 of the International <br /> Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat <br /> recovery efficiency of 0.85. <br /> 112 a <br /> Page 3 of 4 <br />