Laserfiche WebLink
Idaho: : (702)365-9312 fiLochsa <br /> Idaho: (208)342-7168 <br /> Colorado: (720)644-9246 <br /> engineering <br /> Alberta: (587)774-9040 <br /> SIMPSON SIMPSON STRONG-TIE COMPANY INC. <br /> �.„,� � 5956 W.Las Positas Blvd.. Pleasanton,CA 94588. <br /> strove le (8000)9995099 <br /> ® www.stronotie.com <br /> Job Id: ES-152061M Job Name:Broadway&32nd St Apts <br /> Date of Input: May 31,2019 Structural Date of Plans:Feb 25,2019 <br /> Architectural Date of Plans:Feb 22,2019 <br /> Run Configuration: 5.1 <br /> Quantity: 18 <br /> I Capacity Demand Deg D1C <br /> Level Specification Selected DescatioNNotes p <br /> t ) (trips) (kips) On) Ratio <br /> 6 I Plate Height 9.13(ft) RTUD4B Take up Device 9.21 0.14 0.040 2 <br /> BPRTUD346 Plate in Bearing 6.42 0.14 0.001 2 <br /> Inc.Bearing:0.14(kips) ATS-R4 Rod in Tension J 4.27 0.14 0.004 3 <br /> Cum.Tension:0.14(kips) CNW112 Coupler <br /> Shrinkage:0.50(in) i Max.Tension Capacity 4.27 0.14 3 <br /> 7 Plate Height:9.13(ft) RR/Dee I Take up Device 9.21 0.55 0.040 6 <br /> Floor Depth:12.63 On) BPRTUD34B Plate in Bearing 6.42 0.56 0.002 9 <br /> Inc.Bearing:0.55(kips) ATS-R4 Rod in Tension 4.27 0.14 0.004 3 <br /> Corn.Tension:0.14(kips) CNW1/2 Coupler <br /> Shrinkage:0.50(in) Max.Tension Capacity 4.27 0.14 3 <br /> 6 Plate Height 9.13(ft) RTUD4B Take up Device 9.21 1.61 0.040 17 <br /> Floor Depth:12.63(in) BPRTUD3-4B Plate in Bearing 6.42 1.61 0.007 25 <br /> Inc.Bearing:1.61(kips) ATS-R4 Rod in Tension 4.27 1.67 0.048 39 <br /> Cum.Tension:1.67(kips) CNW5/8-1/2 Coupler <br /> Shrinkage:0.50(in) Max.Tenslon Capacity 4.27 1.67 39 <br /> 5 Plate Height 9.13(ft) RTUD5 Take up Device 14.50 2.65 { 0.057 18 <br /> Floor Depth:1263(In) BPRTUDS-6A Plate in Bearing 7.06 2.65 ! 0.010 38 <br /> Inc.Bearing:2.65(kips) ATS-R5 Rod in Tension 6.54 4.32 0.079 66 <br /> Cum.Tension:4.32(kips) CNW314-5/8 Coupler <br /> Shrinkage:0.50 On) Maz.Tenalon Capacity 6.54 4.32 66 <br /> 4 Plate Height 9.06(ft) RTUD6 Take up Device 20.83 3.74 0.059 18 <br /> Floor Depth:1263(in) BPRTUD5.6A Plate in Bearing 7.06 3.74 l 0.015 53 <br /> Inc.Bearing:3.74(kips) ATS-R6 Rod in Tension 9.61 8.01 0.106 83 <br /> Cum.Tension:8.01(kips) CNW3/4-5/8 Coupler <br /> Shrinkage:0.50 On) __` Max.Tension Capacity J 9.61 8.01 83 <br /> Notes: <br /> (1)Run Termination:Top Plates <br /> (2)The maximum tension capacity of the system at any level cannot exceed the summation of the controlling component <br /> capacities of levels above. <br /> Version:3.0.1 b Page 3 of 29 <br /> Lochsa Engineering www.lochsa.com 1-866-606-9784 <br />