9/3/2020 age:_ <br /> City of Everett <br /> 7:24:26AM �y <br /> INSPECTION ACTIVITY REPORT 7 <br /> 11/21/2019 11/21/2019 MUCH 04-ROUGH SDP PARTIALAPPR Dampers/PUD vault 11/20/2019 4:39 PM AMERICAN HOME <br /> IN BUILDERS INC <br /> Contact Name:AMERICAN HOME <br /> BUILDERS INC <br /> Site Address:3214 BROADWAY <br /> Phone:4253241819 <br /> e-Mail:tbering@acg.com <br /> (11/21/20192:11 PM SDP) <br /> Ventilation for the PUD vault room. <br /> Curtain dampers were installed in the <br /> concrete wall with access for service <br /> through the grill. <br /> The ducting that passes through the garage <br /> is wraped in firewrap,two layers,to create a <br /> horizontal shaft. <br /> 11/21/2019 11/21/2019 MECH 04-ROUGH SDP PARTIALAPPR Corridor ventilation (11/21/2019 2:15 PM SDP) <br /> IN Ok to cover the ducts inside the shaft on all <br /> residential floors. <br /> Note:The dampers are outside of this shaft <br /> and will be looked at by the mechanical <br /> inspector after they are framed in. <br /> 12/23/2019 12/23/2019 MECH 04-ROUGH SDP PARTIAL APPR 7th floor 12/20/2019 12:19 PM AMERICAN HOME <br /> IN BUILDERS INC <br /> Bathroom,kitchen and laundry ducting for <br /> all units of the 7th floor. <br /> Contact Name:Trevor Berring <br /> Site Address:5108 West View Dr. <br /> Phone:4253241819 <br /> e-Mail:tberring@acg.com <br /> 1/8/2020 1/8/2020 GAS 01-ROUGH IN SDP PARTIAL APPR 425-471-5233 <br /> (1/8/2020 1:27 PM SDP) <br /> 1/2"gas line,2#pressure,tested at 15# to <br /> serve the RTU. <br /> Ok from level 2 to the roof. <br /> 1/13/2020 1/13/2020 MECH 04-ROUGH SDP PARTIALAPPR eTRAKiT Inspection 1/1020202:58 PM AMERICAN HOME <br /> IN Request BUILDERS INC <br /> Fans and dryer ducts level 6 units and level <br /> 6 corridor exhaust fans. <br /> Contact Name:Trevor Berring <br /> Site Address:5108 West View Dr. <br /> Phone:4253241819 <br /> e-Mail:tberring@acg.com <br /> (1/132020 2:48 PM SDP) <br /> Apartment units 615-628 only.No other <br /> rooms or apts were ready. <br /> Dampers in the corridor must be framed out <br /> and inspected by the mechanical inspector <br /> before drywall cover.see 11-21-19. <br /> 1/14/2020 1/14/2020 MECH 04-ROUGH SDP PARTIALAPPR 7th and 6th floor 1/132020 3:47 PM AMERICAN HOME <br /> IN BUILDERS INC <br /> level 7 corridor framed in fire smoke <br /> damper before cover. <br /> Contact Name:Trevor Herring <br /> Site Address:3214 Broadway Everett <br /> Phone:4253241819 <br /> e-Mail:tberring@acg.com <br /> (1/142020 2:15 PM SDP) <br /> Level 7 F/S damper framing-ok <br /> Level 6 F/S damper framing-ok <br /> Level 6 ducting of units ok except the unit <br /> by the manlift.INSP12 C/��W SYST€MS <br />