American Property Development ES-0599.06 <br /> June 9, 2016 Page 13 <br /> Revised October 16, 2017 <br /> Excavations and Slopes <br /> The Federal and state Occupation Safety and Health Administration (OSHA/WISHA) classifies <br /> soils in terms of minimum safe slope inclinations. In our opinion, based on the soil conditions <br /> encountered during fieldwork for this site, the weathered native soils and existing fill <br /> encountered to depths of up to four feet to seven feet would be classified by OSHA/WISHA as <br /> Type B. Temporary slopes in Type B soils should be sloped at an inclination of at least 1 H:1 V, <br /> or flatter. In our opinion, the dense to very dense native soils below the weathered native soil <br /> and fill would be classified by OSHANVISHA as Type A and B. Temporary slopes over four feet <br /> in height in Type A and Type B soils should be sloped at an inclination no greater than <br /> 0.75H:1V or 1H:1V, respectively. With respect to the proposed building excavations, temporary <br /> slopes inclined at 0.5H:1V are feasible within the very dense silty sand with gravel glacial till <br /> deposits. The geotechnical engineer should observe the excavations to verify the appropriate <br /> allowable temporary slope inclination. <br /> If the above slope gradients cannot be achieved, temporary shoring may be required. <br /> Permanent slopes should maintain a gradient of 2H:1 V, or flatter, and should be planted with an <br /> appropriate species of vegetation to enhance stability and to minimize erosion. <br /> Seismic Considerations <br /> The 2015 International Building Code specifies several soil profiles that are used as a basis for <br /> seismic design of structures. The 2015 IBC recognizes ASCE for seismic site class definitions. <br /> If the project will be permitted under the 2015 IBC, in accordance with Table 20.3-1 of ASCE, <br /> Minimum Design Loads for Buildings and Other Structures, Site Class C, should be used for <br /> design. In our opinion, the site has a low susceptibility to liquefaction. The absence of a <br /> shallow groundwater table observed at the test sites, and the soil relative density observed <br /> throughout the test sites is the primary basis for this conclusion. <br /> Drainage <br /> The presence of excessive groundwater seepage is not expected in the general site and utility <br /> excavations. However, zones of perched seepage are possible and may produce moderate <br /> flow rates within the site excavations. Temporary measures to control groundwater seepage <br /> and surface water runoff during construction would likely involve interceptor trenches and <br /> sumps, as necessary. Based on groundwater seepage conditions observed at the test sites, <br /> we do not anticipate extensive dewatering of excavations will be necessary. <br /> At this time we do not anticipate a permanent sub-slab drainage system will be necessary for <br /> this project. However, the location and depth of groundwater seepage and zones of chronic <br /> groundwater are difficult to predict. Therefore, if unanticipated groundwater conditions are <br /> encountered, the geotechnical engineer should reassess the need for additional drainage below <br /> the slab during construction. <br /> Earth Solutions NW,LLC <br />