_ • <br /> EVERETT August 1, 2019 <br /> WASHINGTON <br /> Owner: Bustard <br /> Job Address: 1601 Florida Dr. <br /> Plan Check No: C1906-012 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Bustard, <br /> In response to the application for a building permit,the plans have been <br /> examined and you are advised that revisions are necessary before a permit can <br /> be issued. Please review and respond to the comments below. <br /> Provide roof framing plan for lower roof over garage. <br /> Provide section detail at cantilevered floor joists. <br /> y All spaces shall be labeled for the intended use with a unique label. <br /> Show all foundation ventilation openings on the foundation plan. <br /> YV Provide 6 mil black vapor barrier in crawl space with edges lapped <br /> minimum 12 inches.Show requirement on plans. <br /> ,.er."-- Provide minimum 18" x 24" crawl space access. Show location on <br /> foundation plan. If access opening is in the floor, show the location on the main <br /> floor plan. <br /> Stub-out #4 rebar at maximum 18" O.C. at all concrete landings at <br /> exterior entrance/exits. Show location of landings and reinforcing steel on <br /> foundation plan. <br /> p Specify on plans, landings are required to be not more than 7-3/4" below <br /> the finished floor. <br /> g The area of floor used for parking of automobiles or other vehicles shall <br /> be sloped to facilitate the movement of liquids to a drain or toward the main <br /> vehicle entry doorway.Show requirement on the plans. <br /> de Provide minimum 5/8-inch Type "X" GWB on the ceiling in the garage, <br /> and minimum 1/2" GWB on all walls supporting a living space above the garage. <br /> Sh w on the plans. <br /> la). Provide the proposed height(elevation)of the structure on the Elevation <br /> Drawings, include the base elevation as determined from the height calculation. <br /> 12. Provide building section drawing(s) specific to this structure. Show each <br /> PUBLIC WORKS different type of construction in a section and/or detail drawing. <br /> 100 Provide the dimensions of each floor level from the top of the foundation <br /> 9 <br /> 3200 Cedar Street to the finished floor, the finished floor to the top plate, the top plate to the <br /> Everett,WA 98201 <br /> finished floor, the finished floor to the top plate, and the top plate to the top of <br /> G425.257.8800 the ridge. <br /> 425.257.8882 fax -;"‘ Dimension all partitions on the floor plans and all walls on the foundation <br /> an. Provide over-all dimension on each side of the proposed dwelling on each <br /> everettpw@everettwa.gov floo y plan. <br /> everettwa.gov/pw <br /> Specify the size of all doors on the floor plans. <br /> Specify framing for stairs and landing on the framing plan. <br /> (776 <br />