Laserfiche WebLink
22. A 2-year Warranty Bond in the amount of 10%of the construction costs for all Stormwater <br /> Infrastructure shall be submitted to the City prior to final approval/close out of the permit. <br /> 23. As-builts of storm sewer,sanitary sewer, and water systems are required to be submitted <br /> per current City of Everett Design and Construction Standards and Specifications for <br /> Development manual, prior to final approval/close out of the permit. <br /> 24. In general, please call out all utilities and site features in accordance with the specific type <br /> and standard drawing number listed in the City's current Design and Construction Standards <br /> and Specifications for Development. https://everettwa.gov/1531/Design-Construction- <br /> Standards <br /> 25. Please also clearly label all features as either existing or proposed and clearly show on the <br /> site plan using specific line types, hatch patterns, and a legend. <br /> 26. After completing all required Land Use processes, please submit 4 sets of civil plans with <br /> your public works permit application package along with 2 sets of drainage reports, <br /> SWPPP's and any additional reports. Please let me know if you have any questions while <br /> putting your plans together. <br /> Fire:Steve Goforth,425.257.8100 <br /> 1. Access The International Fire Code requires that all new structures shall provide Fire <br /> Department access roads to within 150 feet exterior walking distance of all portions of <br /> the ground floor.Fire Department access roads (Fire Lanes) shall provide a minimum of <br /> 20 feet in width of unobstructed, paved driving surface,exclusive of shoulders,with a <br /> minimum clear height of 13'6" Inside turn radii must be 32 feet.Outside turn radii must <br /> be 52 feet for ladder apparatus. Slope approach and departure angles must not exceed <br /> 8 degrees. Fire lane grade must not exceed 10 percent. Fire lane construction must <br /> comply with AASHTO H30 load capacity(80,000 GVW). Fire Lanes will be posted and <br /> maintained as required by the Fire Department. Unorthodox access which meets code <br /> requirements but is too unusual for crews,will not be allowed. Call Fire Marshal's Office <br /> for apparatus specifications. <br /> 2. Fire Lane Marking- Fire apparatus access roads shall be marked whenever necessary to <br /> maintain the unobstructed minimum required width of roadways. Fire lanes shall be <br /> marked as follows: <br /> a. Curbs shall be identified by red traffic paint with a 6-inch wide stripe on the top <br /> and front, extending the length of the designated fire lane. <br /> b. Rolled curbs shall be identified by red traffic paint with a 6-inch wide stripe on the <br /> curb,extending the length of the designated fire lane. <br /> c. Lanes without curbs shall be identified by red traffic paint with a 6-inch wide stripe <br /> on the pavement,extending the length of the designated fire lane. <br /> d. The words 'NO PARKING- FIRE LANE'shall be in 3-inch stroke white letters 18 inches <br /> Revl 18-037 / Page 4 of 7) <br />